Measuring leg muscle and fat mass in humans: comparison of CT and dual-energy X-ray absorptiometry.

Dual-energy X-ray absorptiometry (DEXA) is reported to be inferior to computed tomography (CT) to measure changes in appendicular soft tissue composition. We compared CT- and DEXA-measured thigh muscle and fat mass to evaluate the random and systematic discrepancies between these two methods. Thigh skeletal muscle area (single-slice CT) was suboptimally (r(2) = 0.74, P < 0.0001) related to DEXA-measured thigh fat-free mass (FFM). In contrast, thigh muscle and adipose tissue volumes (multislice CT) were highly related to DEXA-measured thigh FFM and fat (both r(2) = 0.96, P < 0.0001). DEXA-measured leg fat was significantly less than multislice-CT-measured leg adipose tissue volume, whereas multislice-CT-measured leg muscle mass was less (P < 0.0001) than DEXA-measured leg FFM. The systematic discrepancies between the two approaches were consistent with the 10-15% nonfat components of adipose tissue. In conclusion, CT and DEXA measures of appendicular soft tissue are highly related. Systematic differences between DEXA and CT likely relate to the underlying principles of the techniques.

Absorptiometry, Photon

An algorithm for noninvasive identification of angiographic three-vessel and/or left main coronary artery disease in symptomatic patients on the basis of cardiac risk and electron-beam computed tomographic calcium scores.

OBJECTIVES: We sought to model an algorithm for noninvasive identification of angiographically obstructive three-vessel and/or left main disease based on conventional cardiac risk assessment and site and extent of coronary calcium determined by electron-beam computed tomography (EBCT). BACKGROUND: Such an algorithm would greatly facilitate clinical triage in symptomatic patients with no previous diagnosis of coronary artery disease (CAD). METHODS: We examined 291 patients with suspected, but not previously diagnosed, CAD who underwent coronary angiography for clinical indications. Cardiac risk factors were determined as defined by the National Cholesterol Education Program. An EBCT scan was performed in all patients, and a coronary calcium score (Agatston method) was computed. Total per-patient calcium scores and separate scores for the major coronary arteries were generated. These scores were also analyzed for localization of coronary calcium in the more distal versus proximal tomographic sections. These parameters and the risk factors were considered for the model described in the following section. RESULTS: Sixty-eight patients (23%) had angiographic three-vessel and/or left main CAD. Multiple logistic regression analysis determined male sex, presence of diabetes and left anterior descending (LAD) and circumflex (LCx) coronary calcium scores, independent from more distal calcium localization, as independent predictors for identification of three-vessel and/or left main CAD. Based on this four variable model, a simple noninvasive index (NI) was constructed as the following: loge(LAD score) + log(e)(LCx score) + 2[if diabetic] + 3[if male]. Receiver operating characteristic curve analysis for this NI yielded an area under the curve of 0.88+/-0.03 (p < 0.0001) for separating patients with, versus without, angiographic three-vessel and/or left main CAD. Various NI cutpoints demonstrated sensitivities from 87-97% and specificities from 46-74%. The NI values >14 increased the probability of angiographic three-vessel and/or left main CAD from 23% (pretest) to 65-100% (posttest), and NI values <10 increased the probability of no three-vessel and/or left main CAD from 77% (pretest) to 95-100% (posttest). CONCLUSIONS: On the basis of a simple algorithm ("noninvasive index"), EBCT calcium scanning in conjunction with risk factor analysis can rule in or rule out angiographically severe disease, i.e., three-vessel and/or left main CAD, in symptomatic patients.

Algorithms

Comparison of two different software systems for electron-beam CT-derived quantification of coronary calcification.

OBJECTIVE: The growing interest in coronary calcium quantification by electron-beam CT (EBCT) has led to the development of various software systems for the analysis of EBCT raw data, but it is unknown whether these software systems yield comparable results. METHODS: Two sets of EBCT scans were obtained in 73 asymptomatic patients less than 15 minutes apart. Both scans of each patient were analyzed using two different software systems, the Mayo Clinic software and the AccuImage Scoring System. The authors compared the calcium quantities yielded by the two different software systems, analyzed the interscan variability, and calculated the interobserver variability. Finally, they investigated the influence of the CT density factor inherent in the widely used Agatston score for the quantification of coronary calcium on reproducibility. RESULTS: The mean score determined by the Mayo Clinic software was 14% greater than that determined by the AccuImage system. The mean difference between the two systems was 14% +/- 25%, and the median difference was 3%. The relative mean and the median difference between the two scans of one patient were 15.3% and 6% determined by the AccuImage system and 17% and 6.5% determined by the Mayo Clinic software. The interobserver reliability calculated by the Mayo Clinic software was better than that of the AccuImage system. There was a trend for better reproducibility using calcium area rather than the Agatson score. CONCLUSIONS: Two different scoring systems do not necessarily yield the same result. Calcium quantities were systematically determined to be greater by one system than the other, and there were significant differences with regard to interobserver reliability. Hence, software should be tested with regard to reproducibility data, and the interpretation of calcium quantities should acknowledge which type of software was used.

Adult

Pituitary desensitization to gonadotropin-releasing hormone increases abdominal adiposity in hyperandrogenic anovulatory women.

OBJECTIVE: To determine whether hyperandrogenism in anovulatory women affects body fat distribution. DESIGN: Prospective nonrandomized study. SETTING: An academic research environment. PATIENT(S): Ten hyperandrogenic anovulatory patients and 10 healthy women matched by body mass index. INTERVENTION(S): Regional body fat analysis was performed before and after 3 months of GnRH analogue (GnRH-a) therapy. MAIN OUTCOME MEASURE(S): Body fat distribution was measured by waist-to-hip circumference ratio, single-slice computed tomography imaging (L2-3 interspace), and total body dual-energy x-ray absorptiometry. RESULT(S): Weight, body mass index, waist-to-hip circumference ratio, total body and leg fat mass, and subcutaneous adipose area were unaffected by the presence of hyperandrogenism or the use of GnRH-a therapy. Basal abdominal fat mass, abdomen-to-leg fat mass ratio, visceral adipose area, and total visceral adipose volume were comparable in both study groups. The abdominal fat mass increased in both groups during GnRH-a therapy, whereas the abdomen-to-leg fat mass ratio rose significantly only in the hyperandrogenic patients. During GnRH-a therapy, the hyperandrogenic patients demonstrated a significant increase in visceral adipose area compared with the healthy women so that total visceral adipose volume increased significantly in the former but not the latter. CONCLUSION(S): Three months of GnRH-a administration preferentially increased abdominal fat, as measured by single-slice computed tomography imaging and total body dual-energy x-ray absorptiometry, in hyperandrogenic anovulatory women.

Abdomen

Measurement of myocardial infarct size by electron beam computed tomography: a comparison with 99mTc sestamibi.

RATIONALE AND OBJECTIVES: The authors sought to determine, using a variety of regional left ventricular ejection fraction (EF) and wall thickening (WTh) criteria, the applicability to measure left ventricular (LV) infarct size using electron-beam CT (EBCT) in patients as compared with technetium 99m (99mTc) sestamibi scanning as reference standard. METHODS: Twelve patients (age 57 +/- 11 years) underwent 99mTc sestamibi scanning and EBCT at hospital discharge after an acute index anterior myocardial infarction. Left ventricular infarct size was defined using standard 99mTc sestamibi scanning. Regional EF and WTh were analyzed on each EBCT scan with use of a floating epicardial centroid method. In five contiguous LV tomograms, the amount of infarcted myocardium was estimated using the following EF and WTh criteria: EF < or = 35%, 30%, 25%, 20%, and WTh < or = 2 mm, 1 mm, and 0 mm. RESULTS: Infarct size measured with 99mTc sestamibi was 33.3% (+/- 18.3%) (mean +/- SD, range 6%-54%) of the LV. Using an EF < or = 35% or absolute WTh < or = 2 mm as criteria for infarcted myocardium, EBCT yielded 28% (+/- 17%) and 27% (+/- 16%), respectively (P = NS, paired Student's t test, versus 99mTc sestamibi). Although, with use of the other criteria, EBCT tended to underestimate infarct size compared with 99mTc sestamibi, a close correlation across the entire range of infarct size determinations (range, 0.72-0.82) regardless of the underlying criteria suggested an internal consistency of the data. CONCLUSIONS: Quantitative analysis of regional myocardial function by EBCT allows an estimate of anterior infarct size when compared with 99mTc sestamibi. This suggests that in addition to previously established applications after acute myocardial infarction such as examination of cardiac volumes and mass, EBCT also may provide for infarct size determination.

Adult

Automatic segmentation, tissue characterization, and rapid diagnosis enhancements to the computed tomographic colonography analysis workstation.

An image processing system developed to support examination of computed tomographic colonoscopy (CTC) was developed in 1995. The clinical viability of CTC is enhanced by the solution of several technical problems. These problems include the limited detectability of sessile polyps and difficulties in discrimination between polypoid masses and retained stool. CTC is also made more feasible by simplifying the required colon preparation and reducing the time required to analyze scan results. Each of these challenges have been addressed by enhancements to the CTC analysis workstation software. Endoluminal volume rendering has been enhanced by the addition of automatic segmentation to facilitate analysis of colon segments, which contain tagged liquid stool. By automating this function, the system is able to process scans that are acquired following a wide variety of colon preparation protocols. Similar approaches have been used to identify retained stool. Automatic tissue characterization has also been incorporated into the volume rendering routines to help identify and diagnose polypoid masses. These enhancements have improved the quality of CTC interpretation, while reducing the time required to perform the analysis. This time reduction was necessary to reduce the cost of CTC enough to make it viable for asymptotic population screening. To date, over 150 patient examinations have been performed using this new technique. A recent blinded, prospective study reporting the results from two independent observers has been presented. The technique is feasible, reliable, and has been implemented clinically with results reported within 1 hour of the examination.

Colon

Computed tomographic colonography (Virtual colonoscopy): a new method for detecting colorectal neoplasms.

Computed tomographic (CT) colonography is an exciting new technique that uses volumetric CT data combined with advanced imaging software to create two-dimensional and three-dimensional images of the colon. The technique uses both three-dimensional images that simulate the endoluminal perspective of the colonoscope, as well as axial and reformatted two-dimensional images. The two-dimensional and three-dimensional images are complementary, and in combination offer the most robust performance for the detection of colorectal polyps. Currently, CT colonographic examinations are performed in the fully cleansed and air-inflated colon using a slice thickness of 5 mm, a reconstruction interval of 3 mm, a pitch of 1.3, and 70 mA. In a blinded, prospective study of 70 patients (half with a known lesion, and half from a surveillance population with a low disease prevalence) the sensitivity for the detection of polyps of 1 cm or more is 75%, and the specificity is 90%. The most commonly encountered problems include retained colonic fluid and stool, suboptimally distended colonic segments, and long interpretation times. Many of these problems can be solved using both supine and prone imaging. It is expected that the performance of this examination will improve, and that a new era of colorectal screening will begin.

Colonoscopy

Detection of colorectal polyps with CT colography: initial assessment of sensitivity and specificity.

PURPOSE: To estimate the sensitivity and specificity of computed tomographic (CT) colography in detection of colorectal polyps and to compare these findings with those at axial CT. MATERIALS AND METHODS: In 70 consecutive patients, CT colography and colonoscopy were performed. Helical axial CT images and CT colographic images (multiplanar two- and three-dimensional endoluminal images) were evaluated separately by two radiologists blinded to results from colonoscopy and other imaging studies. Findings were compared with those at colonoscopy, which was the standard. RESULTS: The sensitivity and specificity for the two observers with CT colography averaged 75% and 90% in patients with adenomas 10 mm in diameter or larger, 66% and 63% in patients with adenomas 5 mm in diameter or greater, and 45% and 80% for patients with adenomas less than 5 mm in diameter, respectively. Sensitivity and specificity with axial CT were lower than those with CT colography (58% and 74%, respectively) in patients with adenomas 10 mm in diameter or larger. CONCLUSION: Compared with axial CT, CT colography appears to have superior sensitivity and specificity in detection of clinically important colorectal adenomas. Early performance of CT colography seems promising for detection of colorectal polyps 5 mm and larger.

Adenoma

Fixed vs. flexible neuropsychological test batteries under the Daubert standard for the admissibility of scientific evidence.

In Chapple v. Ganger, (1994), the Daubert standard was applied for the very first time to the use of fixed (standardized) versus flexible (nonstandardized) neuropsychological test batteries in the federal court. In this personal injury case the Chapple court gave far greater weight to the results obtained from a fixed battery than to the results obtained from two flexible neuropsychological test batteries. Significantly, under the Daubert standard the District Judge noted the lack of medical and scientific evidence to support the conclusions made by the Plaintiffs' two expert witnesses, a psychologist and a neuropsychologist, even though each had administered a comprehensive and flexible neuropsychological test battery and had based their conclusions on the test results. However, the Judge accepted as scientific evidence the objective test results obtained from the fixed Halstead-Reitan Neuropsychological Test Battery for Older Children administered by the Defendants' expert witness Dr. Ralph Reitan and also accepted his scientific expert medical testimony which was closely derived from these data. Applying the Daubert standard to the neuropsychological test results and opinions of the expert witnesses, the District Judge held that the entire reasoning process and not simply part of the reasoning process upon which the expert witness derives a conclusion must reflect scientific methodology.

Criminal Law

Regional left ventricular wall thickness and systolic function during the first year after index anterior wall myocardial infarction: serial effects of ventricular remodeling.

There is controversy regarding changes in regional left ventricular systolic function and thickness during remodeling after infarction. To address this, electron beam computed tomography was done in 22 patients with an index anterior wall infarction at discharge, 6 weeks, 6 months and 1 year, and global ventricular chamber volumes and mass quantified. A mid-ventricular short-axis scan from each study was divided into 4, 90 degrees sectors (anterior, septal, lateral and posterior walls). Regional wall thickness, ejection fraction, and absolute and percent wall thickening were determined and compared with 10 normal adults. Global infarct size was estimated at 24.2%+/- 3.4% of the ventricle. In these subjects, the ventricular chamber enlarged steadily during the year, while global ventricular mass initially decreased during the first 6 weeks, but then increased by 1 year. Regional ejection fraction changed little during the year, apart from the lateral wall, which was less than normal. Absolute wall thickening was reduced in the anterior (infarct) and septal walls throughout the year, but was normal and unchanged in the posterior and lateral walls. Regional percent wall thickening was not different from normal individuals. The anterior wall was thinned at discharge and tended to thin further during the year. The lateral wall was thinner than normal 6 weeks after infarction, but remained unchanged thereafter. The posterior wall tended to thin for the first 6 months, but the values at any time were not above normal. There was little change in septal wall thickness throughout the year. It is concluded that, after a moderate size, uncomplicated index anterior infarction, regional systolic function remains generally unaffected by remodeling. However, regional walls tend to thin and/or remain at normal thickness. These data confirm differential regional patterns after anterior infarction for systolic function, muscle atrophy and/or minimal hypertrophy which accompany serial changes in global ventricular chamber volumes and mass.

Aged

Detection of colorectal polyps by computed tomographic colography: feasibility of a novel technique.

BACKGROUND & AIMS: Computed tomographic colography (CTC) represents a novel technique for colorectal polyp detection. A prospective study was undertaken to determine the optimal CTC scanning parameters based on an artificial colon model and to assess the feasibility of CTC to detect clinically significant colorectal polyps. METHODS: A colon model was scanned by helical computed tomography at multiple parameters. Reformatted two-dimensional and three-dimensional images were then graded for polyp detection and image quality. Subsequently, 10 patients with known colon polyps underwent CTC immediately before colonoscopy. The number of polyps detected by two radiologists using CTC were compared with colonoscopy results that served as the gold standard. RESULTS: The optimal scanning parameters in the colon model were 5-mm collimation, 5 mm/s table speed, and 1-mm reconstruction interval. Ten patients had 30 polyps (range, 0.2-2.0 cm) by colonscopy, and all polyps > or = 0.5 cm were adenomas. Polyp detection by CTC for both observers was 100% (5 of 5) > or = 1 cm, 71% (5 of 7) between 0.5 and 0.9 cm, and 11%-28% (2-5 of 18) < 0.5 cm. CONCLUSIONS: Based on this small, unblinded pilot study, CTC is feasible for colorectal polyp detection > or = 0.5 cm in diameter.

Aged

Colorectal polyp detection with CT colography: two- versus three-dimensional techniques. Work in progress.

PURPOSE: To compare detection of colorectal polyps with two-dimensional (2D) computed tomographic (CT) colography only, three-dimensional (3D) CT colography only, and a combination of 2D and 3D CT colography. MATERIALS AND METHODS: A total of 11 computer-simulated polyps (1-10 mm) were placed randomly in five identical CT data sets for images of a 72-year-old man's polyp-free, rectosigmoid colon. Fifteen CT colographic data sets were produced: five with 2D CT images only, five with 3D CT images only, and five with 2D and 3D CT images. Two radiologists randomly, blindly, and independently evaluated all 15 data sets to detect the simulated polyps. RESULTS: No polyps 2 mm or smaller were detected. No statistically significant differences in the detection of colorectal polyps were found between the three techniques. However, the combination of 2D and 3D CT colography resulted in polyp detection rates that were greater than or equal to those of 2D or 3D CT colography alone. Flat polyps were more difficult to detect than sessile polyps. Five false-positive findings occurred with 2D CT colography. CONCLUSION: A combined display of 2D and 3D CT images likely provides the greatest rate of detection of colorectal polyps.

Aged

Serial changes in left and right ventricular systolic and diastolic dynamics during the first year after an index left ventricular Q wave myocardial infarction.

OBJECTIVES: This study quantified serially biventricular emptying and filling after infarction and related these to changes in volume, muscle mass, wall stress and contractility. BACKGROUND: There are limited data on serial changes in ventricular dynamics after infarction. METHODS: Forty patients had serial electron beam computed tomographic examinations during the first year after index Q wave infarction (21 anterior, 19 inferior), and global biventricular volumes, peak rates of emptying and filling and left ventricular muscle masses were quantified. Mean mid-left ventricular end-systolic wall stresses, rate-corrected velocities of circumferential shortening and two indexes of left ventricular contractility--the end-systolic wall stress/volume ratio and the end-systolic wall stress/rate-corrected velocity of circumferential shortening relation--were estimated in each instance. RESULTS: Patients with anterior infarction had an increase in biventricular chamber volume of 15% to 35% by 1 year. Global biventricular peak rates of emptying and filling were decreased by 20% to 30% from hospital discharge to 6 weeks but thereafter remained unchanged. Despite a significant increase in mean wall stresses, the end-systolic wall stress/volume ratio remained unchanged during the year. The rate-corrected velocities of circumferential shortening declined serially after anterior infarction but did so in proportion to the increase in mean wall stresses, consistent with no net change in left ventricular contractility. Patients with inferior infarction showed a trend toward similar changes, but the magnitudes did not reach significance. CONCLUSIONS: Left (and right) ventricular global peak rates of emptying and filling during the first year after infarction can be altered in the absence of additional ischemic injury but are more consistent with responses to changes in left ventricular afterload than changes in intrinsic ventricular performance or contractility. Serial changes in left ventricular afterload after infarction are largely due to progressive chamber enlargement and limited development of compensatory hypertrophy during the first year. Intrinsic global left ventricular contractile performance was not altered by postinfarction cardiac remodeling in the patients examined.

Coronary Circulation

Serial changes in regional right ventricular free wall and left ventricular septal wall lengths during the first 4 to 5 years after index anterior wall myocardial infarction.

OBJECTIVES: This study investigated serial changes in regional right ventricular free wall and interventricular septal wall lengths during the first 4 to 5 years after an index anterior wall myocardial infarction. BACKGROUND: We previously demonstrated that remodeling after anterior wall myocardial infarction was a biventricular process; however, regional changes in biventricular topology were not investigated. METHODS: Serial electron beam computed tomographic scanning was performed in 19 patients at five times (hospital discharge and at 6 weeks, 6 months, 1 year and 4 to 5 years) after an index anterior wall myocardial infarction, and global and regional right ventricular free wall and interventricular septal wall lengths were quantified. RESULTS: At a mean (+/- SD) of 1,642 +/- 171 days (4 to 5 years) after infarction, global end-diastolic and end-systolic right ventricular free wall and interventricular septal wall lengths increased in parallel by 13% to 23% as global left and right ventricular volumes increased 22% to 29% from hospital discharge to 4 to 5 years after infarction. When global right ventricular free wall was compared with interventricular septal wall lengths, percent increases at end-diastole and end-systole were not statistically different at any time during the study period. Distinct regional changes in both right ventricular free wall and interventricular septal wall lengths after infarction were most dramatic during the first 6 weeks and primarily confined to the most apical levels. However, further and significant increases in both were observed by 4 to 5 years after infarction. CONCLUSIONS: Changes in both right ventricular free wall and interventricular septal wall lengths were apparent during the 4 to 5 years after the index anterior wall infarction, and the combination of both contributed to global increases in right and left ventricular chamber volumes. Regional changes in both right ventricular free wall and interventricular septal wall lengths were almost exclusively confined to their respective apices and progressed generally in parallel; however, the cause-and-effect relation remains speculative at the present time.

Adult