An investigation of factors influencing the measurement of creatine phosphokinase activity in serum using coupled enzymatic methods.

1. The factors influencing the measurement of creatine phosphokinase (CPK) activity in serum by coupled enzymatic methods were investigated to establish optimum conditions for this type of assay. Such a study was indicated following observations by the authors of poor performance of commerically produced reagent kits together with the failure of most of the established an well accepted methods to operate under true optimum zero order kinetics in the reaction phase state. 2. The factors invested were the effects of pH, substrate concentrations (creatine phosphate, glucose and NADP+), added auxiliary (hexokinase) and indicator (glucose-6-phosphate dehydrogenase) enzymes, dithiothreitol (DTT) as an activator and conditions of storage of substrate stability. DTT was found to be a suitable activator but not a reactivator of the reaction. The optimum concentrations of creatine phosphate, glucose and NADP+ were found to be 20.0, 20.0 and 2.0 mmol/litre, respectively. Optimum activieies of the enzymes, glucose-6-phosphate dehydrosenase and hexokinase were 1000 and 2000 units/litre, respectively. 3. The between-day precision of the method for measuring serum at pH 6.8 and 30 degrees C at three activity levels under the optimum conditions developed was excellent yielding coefficients of variation ranging from 2.0 to 2.7%.

Creatine Kinase↗

The use of in vitro diagnostic kits in hospital laboratories in Canada.

1. A survey conducted among hospital laboratories has yielded data from 640 institutions concerning the use of diagnostic kits and reagents in Canada. 2. Kits designed to test for chemical constituents were most frequently used in hospitals of 51 to 600 bed capacity whereas the ones for enzymes were most extensively used in 201 to 700 bed-size institutions. Kits based on the CPB principles were generally used in hospitals of more than 200 beds whereas those based on RIA were only in frequent use where the bed capacity was 351 or more. 3. The following tests were most often performed by kits: aminotransferases, amylase, urea, LDH, phosphatases, glucose, CPK, bilirubin, calcium, uric acid, T-4, T-3, digoxin and vitamin B12. 4. The survey reflects a continuing and increasing usage of in vitro diagnostic kits and associated blood analyzer systems. It also indicates a significant adoption of assay kits which utilize RIA and CPB principles.

Blood Chemical Analysis↗

An evaluation of commercial kits for creatine phosphokinase assay.

1. The evaluation of seven colorimetric and twelve kinetic or ultra-violet (UV) creatine phosphokinase (CPK) kit methods for their reliability as a diagnostic tool in clinical laboratories has revealed that over 35% of such commercial products readily available in Canada do not yield reliable results. 2. Six out of seven colorimetric kits failed to meet the criteria of minimum reliability as did one of the twelve UV kinetic kits.

Creatine Kinase↗

A survey of hemoglobin values in Canada.

A compilation of hemoglobin values has been made from submissions from laboratories in Canada using the cyanmethemoglobin standard prepared and distributed by the Canadian Communicable Disease Centre (formerly the Laboratory of Hygiene). From 84 participating laboratories 21,580 values were analyzed statistically by age and sex. "Medical referrals", exclusive of blood dyscrasias, were included but were documented separately from "well persons". In most age groupings no significant difference in these two categories was found.Values for boys and girls were similar up to 12 years of age. For adult women from 18 to 84 years the mean value was 13.0 g. per 100 ml. (95% confidence limits 10.8-15.2 g.); for pregnant women 19 to 44 years the mean value was 12.2 g. per 100 ml. (9.7-14.6 g.). For men aged 17 to 24 years the mean value was 15.0 g. per 100 ml. (12.8-17.3 g.); 25-49 years 14.6 g. per 100 ml. (12.4-16.9 g.); 50-69 years 14.3 g. per 100 ml. (11.8-16.8 g.). It is noteworthy that for the most part the mean values were slightly lower than those frequently quoted as "normal" and that the mean values, particularly for the male, were lower with increasing age.

Adolescent↗

Hemoglobinometry.

Explore the source record for details and available documents.

Carbon Monoxide Poisoning↗