Search PubMed⌕ Search

Biomedical subjects

J E Heiserman

Publications and source records attributed to J E Heiserman.

At least 19 recordsLinked to original sources

Incidence of postangiographic abnormalities revealed by diffusion-weighted MR imaging.

BACKGROUND AND PURPOSE: Occasionally we have observed anecdotal cases of asymptomatic hyperintensities on diffusion-weighted MR (DW-MR) examinations of the brain of patients who previously underwent routine cerebral angiography. These observations, as well as MR imaging and transcranial Doppler data in the literature suggesting a high rate of procedure-associated emboli, raise concern regarding the underdiagnosis of asymptomatic focal infarction associated with cerebral angiography. In order to determine whether asymptomatic diffusion abnormalities are frequently associated with procedures, we prospectively obtained DW-MR images before and after routine cerebral angiography. METHODS: Twenty consecutive patients, who met protocol criteria and received a routine three- or four-vessel diagnostic cerebral angiogram at our institution, were evaluated. Using a Bayesian estimate to establish an upper bound for the incidence of an event with zero occurrences in a study sample, the study group size was selected to exclude a 10% incidence of abnormalities revealed by DW-MR imaging of patients who underwent previous cerebral angiography. Two neuroradiologists evaluated imaging studies. RESULTS: Neither clinical signs nor abnormalities on DW-MR images were found, which suggested no infarction after angiography in our patient sample. Based on this data, an upper bound of 9% (95% confidence) is predicted for the appearance of abnormalities revealed by DW-MR imaging after cerebral angiography. CONCLUSION: Cerebral angiography is associated with an incidence of asymptomatic cerebral infarction of no more than 9%. It well may be substantially lower than this estimate; a more accurate evaluation of the true incidence would require a significantly larger study population. This test provides a convenient noninvasive means of assessing procedure-related cerebral infarction, such as that which occurs after carotid endarterectomy or vascular angioplasty and stenting.

Adult↗

Cerebral MR venography: normal anatomy and potential diagnostic pitfalls.

BACKGROUND AND PURPOSE: MR venography is often used to examine the intracranial venous system, particularly in the evaluation of dural sinus thrombosis. The purpose of this study was to evaluate the use of MR venography in the depiction of the normal intracranial venous anatomy and its variants, to assess its potential pitfalls in the diagnosis of dural venous sinus thrombosis, and to compare the findings with those of conventional catheter angiography. METHODS: Cerebral MR venograms obtained in 100 persons with normal MR imaging studies were reviewed to determine the presence or absence of the dural sinuses and major intracranial veins. RESULTS: Systematic review of the 100 cases revealed transverse sinus flow gaps in 31% of the cases, with 90% of these occurring in the nondominant transverse sinus and 10% in the codominant transverse sinuses. No flow gaps occurred in the dominant transverse sinuses. The superior sagittal and straight sinuses were seen in every venogram; the occipital sinus was seen in only 10%. The vein of Galen and internal cerebral veins were also seen in every case; the basal veins of Rosenthal were present in 91%. CONCLUSIONS: Transverse sinus flow gaps can be observed in as many as 31% of patients with normal MR imaging findings; these gaps should not be mistaken for dural sinus thrombosis.

Adolescent↗

Effect of voxel position on single-voxel MR spectroscopy findings.

BACKGROUND AND PURPOSE: Single-voxel MR spectroscopy is a widely used tool for evaluating brain tumors. Although extensive data are available on the MR spectral appearance of tumors, less is known about the effect of voxel position on the accuracy of single-voxel MR spectroscopy findings. The purpose of this study was to test the hypothesis that the accuracy of single-voxel MR spectroscopy in the categorization of lesions as either tumor or not tumor is dependent on voxel position. METHODS: Fifty single-voxel MR spectra acquired with a fully automated stimulated-echo spectroscopy sequence were reviewed retrospectively in 43 patients with new or previously treated intra-axial brain tumors. Spectra were analyzed for the presence of choline, creatine, N-acetylaspartate (NAA), and lipid/lactate. Choline/creatine and NAA/creatine peak area ratios were assessed qualitatively. Lesions were grouped into one of three categories on the basis of spectral pattern: tumor, not tumor, or indeterminate. Results of MR spectroscopy were compared with the final histopathologic diagnosis. RESULTS: Histologic confirmation was obtained in 19 patients; MR spectra were interpretable in 17 of those. MR spectra correctly categorized nine of 17 lesions (six tumor, three nontumor). All eight misdiagnosed lesions were tumors. When the MR spectroscopy voxel included the enhancing edge of the lesion, the spectra correctly categorized seven of eight lesions (four of five tumors and all three cases of radiation necrosis). When the MR spectroscopy voxel was positioned centrally within the lesion, the spectra correctly reflected histologic outcome in two of nine lesions (all tumors). CONCLUSION: The reliability of single-voxel MR spectroscopy findings is dependent on voxel position. Spectra obtained from voxels at the enhancing edge of a tumor more accurately reflect lesion histopathology than do spectra obtained from the lesion center, even if the centrally placed voxels contain solidly enhancing tissue.

Aspartic Acid↗

MR angiography. Toward faster and more accurate methods.

MR angiography is a class of methods developed to noninvasively evaluate vascular structures. After first reviewing the different approaches and comparing strengths and weaknesses, new methods to improve the quality or speed of acquisition of these important sequences are examined.

Artifacts↗

The radiographic and imaging characteristics of porous tantalum implants within the human cervical spine.

STUDY DESIGN: Seven cadaveric cervical spines were implanted with a porous tantalum spacer and a titanium alloy spacer, and their radiographic and imaging characteristics were evaluated. OBJECTIVE: To determine the radiographic characteristics of porous tantalum and titanium implants used as spacers in the cervical spine. SUMMARY OF BACKGROUND DATA: Anterior decompressive surgery of the disc space or the vertebral body creates a defect that frequently is repaired with autologous bone grafts to promote spinal fusion. Donor site morbidity, insufficient donor material, and additional surgical time have spurred the development of biomaterials to replace or supplement existing spinal reconstruction techniques. Although the promotion of a solid bony fusion is critical, the implanted biomaterial should be compatible with modern imaging techniques, should allow visualization of the spinal canal and neural foramina, and should permit radiographic assessment of bony ingrowth. METHODS: Cadaveric spines containing the implants were imaged with plain radiography, computerized tomography, and magnetic resonance imaging. The image distortion produced by the implants was determined qualitatively and quantitatively. RESULTS: The tantalum and titanium spacers were opaque on plain radiographic films. On computed tomographic scans, more streak artifact was associated with the tantalum implants than with the titanium. On magnetic resonance imaging, the porous tantalum implant demonstrated less artifact than did the titanium spacer on T1- and T2-weighted spin echo and on T2*-weighted gradient-echo magnetic resonance images. Overall, the tantalum implant produced less artifact on magnetic resonance imaging than did the titanium spacer and therefore allowed for better visualization of the surrounding bony and neural structures. CONCLUSION: The material properties of titanium and porous tantalum cervical interbody implants contribute to their differential appearance in different imaging methods. The titanium implant appears to image best with computed tomography, whereas the porous tantalum implant produces less artifact than does the titanium implant on several magnetic resonance imaging sequences.

Artifacts↗

Differentiating recurrent tumor from radiation necrosis: time for re-evaluation of positron emission tomography?

UNLABELLED: Our purpose was to evaluate the ability of FDG PET to differentiate recurrent tumor from posttherapy radiation necrosis. METHODS: MR images, PET scans, and medical records of 84 consecutive patients with a history of a treated intracranial neoplasm were evaluated retrospectively. In all patients, recurrent tumor or radiation necrosis was suggested by clinical or MR findings. Metabolic activity of the PET abnormality was compared qualitatively with normal contralateral gray and white matter. RESULTS: PET findings were confirmed histologically in 31 patients. With contralateral white matter as the standard of comparison, the PET scan sensitivity and specificity were found to be 86% and 22%, respectively. With contralateral gray matter as the reference standard, the sensitivity and specificity became 73% and 56%, respectively. Overall, nearly one third of the patients would have been treated inappropriately in either scheme had the PET scan been the sole determinant of therapy. CONCLUSION: Our data suggest that the ability of FDG PET to differentiate recurrent tumor from radiation necrosis is limited. Both false-positive and false-negative PET scan results contributed to unacceptably low sensitivity and specificity values.

Diagnosis, Differential↗

Absence of pontine lesions in narcolepsy.

A recent study reporting pontine lesions on magnetic resonance imaging in three patients with idiopathic narcolepsy postulated that the lesions represented tissue change secondary to long duration of disease. We studied twelve narcoleptic patients with MRI to validate these findings. The diagnosis of narcolepsy was established with both clinical and electrophysiological criteria in all twelve patients. Pontine lesions were present in two patients, both of whom were hypertensive. The lesions were associated with similar lesions in the hemispheres and were indistinguishable from ischemic change. No lesions were evident in the other ten patients, eight of whom were normotensive, and six of whom had narcolepsy for more than 37 years. We were unable to confirm the presence of pontine lesions specific to narcolepsy.

Adult↗

Juvenile active ossifying fibroma. Report of four cases.

Juvenile active ossifying fibroma is a rare lesion seldom seen by neurosurgeons. It originates in the paranasal sinuses during childhood, grows slowly, and encroaches on adjacent orbital and cranial compartments. In the past 3 years, four patients with this lesion were seen (three men and one woman; mean age 28 years). The clinical presentations were different with each patient: sinusitis, meningitis, periorbital pain, and a unique case of a juvenile active ossifying fibroma presenting with high-grade internal carotid artery stenosis and ischemic symptoms. Three patients were treated by transfacial approaches: two with a transfrontal-nasal approach and one with a transfrontal-nasoorbital approach. Two open resections resulted in gross-total excision and no recurrence as of the 2-year follow-up review. In the third patient, the tumor-encased carotid artery was preserved at the expense of a complete resection; that patient underwent superficial temporal artery-middle cerebral artery bypass and remains without ischemic symptoms or tumor recurrence at 2 years. The fourth patient underwent three subtotal endoscopic resections and is also without symptomatic recurrence at 2 years. Three points must be made concerning these lesions. First, the clinical and radiographic characteristics of juvenile active ossifying fibroma may not be easily recognized by neurosurgeons, which could lead to misdiagnosis and mismanagement of these lesions. Second, this tumor can encase the carotid artery and cause severe stenosis or occlusion. Third, complete resection of the tumor is required to effect a cure, and transfacial approaches, which give wide exposure of the sinuses, appear to yield better, more radical resections than endoscopic procedures.

Adult↗

An alternative to GRASE: toward spin-echo-like contrast with independent reconstruction of gradient-echo images.

Multiple gradient echoes are generated for each RF echo of a Carr-Purcell-Meiboom-Gill (CPMG) train. Independently, phase-encoded fast spin-echo images are obtained from the different gradient echoes. Presently, three images are formed from three gradient-echoes from each of four RF echoes. The two peripheral gradient echo images are encoded for a late effective TE, then summed after reconstruction: this image has decreased fat intensity and increased susceptibility contrast compared with fast spin echo. The central gradient echoes yielded another image of intermediate contrast useful for neuroimaging. Raw data from the variously timed gradient echoes are not combined as they are in GRASE.

Brain↗

Comparison of centralized versus "site-based" measurement of angiographic stenosis for eligibility in the asymptomatic carotid atherosclerosis study.

RATIONALE AND OBJECTIVES: The authors determine the reliability of centralized versus noncentralized (site-based) measurement of angiographic stenosis of patients enrolled into the multicenter, prospective, Asymptomatic Carotid Atherosclerosis Study by angiographic studies. METHODS: Percent agreements and correlations of 244 masked and prospectively interpreted angiograms were calculated for comparison of centralized and noncentralized readers measuring the percent carotid stenosis from the same angiographic studies. Univariate summary statistics for differences in percent stenoses were calculated for these readings. RESULTS: Agreement between readings were 88.5% and 91.8% with kappa statistics of 0.77 and 0.73 for > or = 60% and > or = 80% stenosis, respectively, for comparison of 33 centers to the designated central reader. Comparison between the designated central reader and a second central reader derived percent agreements of 85.0% and 86.5% with kappa statistics of 0.69 and 0.41 for > or = 60% and > or = 80% stenoses, respectively, for arteries selected from the original group. Hence, agreement was slightly better between the enrolling centers and the designated central reader than between the two central readers. CONCLUSIONS: Both centralized and noncentralized (site-based) methods of angiographic measurement of stenosis are equally reliable for large, prospective, masked, multicenter trials when quality control measures are instituted to ensure uniform application of eligibility criteria.

Angiography↗

Titanium aneurysm clips: Part III--Clinical application in 16 patients with subarachnoid hemorrhage.

This report describes the first clinical use of newly developed titanium clips in the treatment of 16 patients with subarachnoid hemorrhage. There were no immediate or delayed complications related to the titanium clips. Thirteen patients had good outcomes, and one patient had moderate disabilities (mean follow-up, 5.4 mo). Two patients with Hunt and Hess Grade IV hemorrhages died postoperatively. The average cross-sectional areas of clip artifact on postoperative magnetic resonance imaging studies was 0.96, 1.36, and 1.05 cm2 on T1-, T2-, and intermediate-weighted images, respectively. In comparison, a matched control group with cobalt alloy clips had average cross-sectional areas of 3.13, 3.70, and 2.81 cm2 on T1-, T2-, and intermediate-weighted images, respectively. The average artifact volumes on gradient echo magnetic resonance images for titanium and cobalt alloy clips were 1.8 and 10.1 cm3, respectively. In addition, the gap on magnetic resonance imaging angiograms from clip artifacts was 0.9 cm with titanium and 2.6 cm with cobalt alloy clips. In conclusion, titanium aneurysm clips seem to be safe and effective and seem to reduce clip artifacts on magnetic resonance imaging threefold, compared with commercially available cobalt alloy clips. Because of this important advantage over conventional clips, titanium clips should be considered for routine use in aneurysm surgery.

Adult↗

Clinical significance of the flow gap in carotid magnetic resonance angiography.

Magnetic resonance (MR) angiography offers a safe, noninvasive alternative to conventional angiography in patients with suspected carotid stenosis; however, it tends to overestimate the severity of stenosis. Loss of the MR signal with a resulting flow gap is a frequent finding in cases of high-grade stenosis. The authors undertook this study to define the range of carotid stenosis associated with a flow gap on two-dimensional time-of-flight (2DTF)-MR angiography. Blinded evaluations were made of 102 common carotid bifurcations in 51 patients who had undergone both conventional angiography and 2DTF-MR angiography. The percent of diameter stenosis was calculated from the conventional angiogram using the method adopted by the Asymptomatic Carotid Atherosclerosis Study (ACAS) trial. An MR flow gap was noted if there was a segment of the vessel that was completely free of signal with a reappearance of the signal distally. According to conventional angiography, the minimum percentage of stenosis associated with a flow gap is 56%. Flow gaps were present in 20 of 22 arteries (sensitivity 91%) with stenosis of 60% or more and in two of the 66 arteries (specificity 97%) with less than 60% stenosis. Flow gaps were present in all arteries with stenosis of 70% or more. Complete occlusion was correctly identified in 10 of 10 cases. These results demonstrate that the presence of a flow gap on 2DTF-MR angiography is a reliable marker of clinically significant carotid stenosis (measuring 60% or more), with sensitivity and specificity comparable to duplex carotid ultrasound. In addition, MR angiography can be used to screen the intracranial circulation for significant vascular pathology in patients being considered for carotid endarterectomy.

Adult↗

The carotid artery: embryology, normal anatomy, and physiology.

The anatomy and physiology of the normal carotid artery serves as a starting point for understanding and evaluating existing and new methods for diagnosing carotid artery disease. This article summarizes the history and state of the art of carotid artery structure and function.

Carotid Arteries↗

A Nyquist modulated echo-to-view mapping scheme for fast spin-echo imaging.

A new scheme for assignment of echoes to views in fast spin-echo imaging was developed. The scheme places early and late echoes in alternating lines of the periphery of k-space; continued alternation of echoes arising closer to the middle of the echo train encodes the central portion of k-space. The scheme has two effects: a) The echo-to-echo signal decay that usually gives rise to multiple faint ghosts, now yields a single Nyquist ghost that is removed by phase over-sampling. b) Mapping earlier echoes (and thus more energy) to the periphery of k-space yields sharper edges.

Humans↗

Serial magnetic resonance imaging in isolated angiitis of the central nervous system.

Isolated angiitis of the central nervous system (IACNS) is a rare form of vasculitis restricted to the CNS. We report serial MRI findings in a biopsy-proven case of IACNS. MRI showed extensive white matter and subcortical disease. Before specific treatment, neuroimaging showed the development of new lesions corresponding with an overall progressive clinical course of the illness; the post-treatment MRI showed improvement.

Brain↗

Surgical management of spinal epidural hematoma: relationship between surgical timing and neurological outcome.

Thirty patients were treated surgically for spinal epidural hematoma (SEH). Twelve of these cases resulted from spinal surgery, seven from epidural catheters, four from vascular lesions, three from anticoagulation medications, two from trauma, and two from spontaneous causes. Pain was the predominant initial symptom, and all patients developed neurological deficits. Eight patients had complete motor and sensory loss (Frankel Grade A); six had complete motor loss but some sensation preserved (Frankel Grade B); and 16 had incomplete loss of motor function (10 patients Frankel Grade C and six patients Frankel Grade D). The average interval from onset of initial symptom to maximum neurological deficit was 13 hours, and the average interval from onset of symptom to surgery was 23 hours. Surgical evacuation of the hematoma was performed in all patients; 26 of these improved; four remained unchanged, and no patients worsened (mean follow up 11 months). Complete recovery (Frankel Grade E) was observed in 43% of the patients and functional recovery (Frankel Grades D or E) was observed in 87%. One postoperative death occurred from a pulmonary embolus (surgical mortality 3%). Preoperative neurological status correlated with outcome; 83% of Frankel Grade D patients recovered completely compared to 25% of Frankel Grade A patients. The rapidity of surgical intervention also correlated with outcome; greater neurological recovery occurred as the interval from symptom onset to surgery decreased. Patients taken to surgery within 12 hours had better neurological outcomes than patients with identical preoperative Frankel grades whose surgery was delayed beyond 12 hours. This large series of SEH demonstrates that rapid diagnosis and emergency surgical treatment maximize neurological recovery. However, patients with complete neurological lesions or long-standing compression can improve substantially with surgery.

Adolescent↗