A new, simple, inexpensive means of testing functional vitamin A status: the night vision threshold test (NVTT). A preliminary field-test report.

Vitamin A deficiency is the leading cause of preventable childhood blindness in developing countries. Each year, an estimated 13.5 million children world-wide are unable to adapt to the dark and half a million children progress to complete blindness annually from lack of vitamin A. Most of the currently available methods for assessing vitamin A status are expensive, require sophisticated instrumentation and are not efficacious in field conditions. A simple, inexpensive method was developed to identify children with defective dark-adaptability, thereby providing a reflection of marginal vitamin A stores. The purpose of this preliminary study was to test the field-efficacy of the Night Vision Threshold Tester (NVTT). Thirty-nine middle-school children with a mean age of 13.5 +/- 1.37 years were initially tested for their ability to adapt to the dark using the

Child↗

Using corneal height maps and polynomial decomposition to determine corneal aberrations.

PURPOSE: To review the use of corneal videokeratoscopic height date, elaborate on the advantages and disadvantages of such data, describe techniques for overcoming the limitations of height data, and demonstrate its use in quantifying the optical properties and aberrations of the cornea. METHODS: The steep sag of the cornea hides fine variations in corneal height that arise naturally or due to disease or surgery. The dynamic range, or ratio of the overall sag to the feature height, is the primary limitation of videokeratoscopic height data. Techniques for removing single or multiple reference surfaces are described in detail, and applications of the methodology to wavefront and raytracing analysis of corneal aberrations arising from radial keratotomy (RK), photorefractive keratectomy (PRK), and keratoconus are described. RESULTS: Removing a single reference surface from the raw corneal height data begins to reveal subtle variations in corneal height. However, expansion of surface height data into a complete set of basis functions provides a sophisticated method for extracting high-order corneal variations. Choosing an orthogonal basis set provides a robust least-squares fit and forms unique expansions of the surface. The resulting coefficients are uncorrelated and form a simple measure of the optical quality. CONCLUSION: Videokeratoscopic height data are useful for analyzing and quantifying corneal deformity arising from disease or refractive surgery and they provide a sophisticated alternative or complement to dioptric power maps.

Cornea↗

Optical modeling of radial keratotomy incision patterns.

PURPOSE: To determine the optical effects of higher-order corneal shape variations resulting from radial keratotomy. METHODS: Videokeratoscopic height data were obtained postoperatively from several patients who had undergone radial keratotomy. For each of clear central zone sizes 3.00 mm, 4.00 mm, and 4.75 mm, two patients were chosen randomly from the larger study group. Data obtained 2 weeks postoperatively from these six patients were decomposed into the Zernike polynomials, and the low-order expansion terms were removed to disclose corneal height variations (the radial keratotomy artifact). The artifact was applied to a schematic eye model, and exact ray-tracing was used to evaluate visual performance, which was defined as a function of pupil diameter, optical zone (central clear zone) size, and radial keratotomy artifact centration. RESULTS: The radial keratotomy artifact degrades visual performance at midspatial frequencies more than it does at high spatial frequencies. This effect is most pronounced for smaller optical zones and for a pupil diameter of 4 mm. Visual performance remains nearly constant for small decentration (0.5 mm or less) of the radial keratotomy optical zone from the corneal apex. CONCLUSIONS: Residual refractive error, corneal asphericity, and the radial keratotomy artifact all affect visual performance after radial keratotomy. Isolated effects of the radial keratotomy artifact degrade visual performance, with the level of degradation dependent on pupil size, optical zone size, and centration of the procedure. More research is necessary to combine the radial keratotomy artifact with changes in corneal asphericity and to further quantify the optical effects of radial keratotomy.

Contrast Sensitivity↗

Keratoconus detection based on videokeratoscopic height data.

PURPOSE: To develop a videokeratoscopic-based keratoconus detection scheme that avoids the ambiguity of dioptric power definitions and videokeratoscope design. METHODS: Corneal height data obtained with a commercial videokeratoscope are decomposed into the set of orthogonal Zernike polynomials. Expansion coefficients of a "normal" group and a keratoconus group are compared to find significant differences. Elevated Zernike terms are used to detect the disease in these populations. The performance of this detection scheme is compared to other videokeratoscopic keratoconus Indices. RESULTS: Two low-order Zernike polynomial terms are identified as being elevated in keratoconus patients and combined to form a new detection index. This index performed at least as well as keratoconus detection schemes based on the inferior-superior (I-S) value, the steepest radial axes (SRAX), and the Surface Asymmetry Index (SAI) for the samples studied. CONCLUSION: The proposed Zernike scheme offers a potentially viable algorithm for detecting keratoconus that avoids the ambiguities of dioptric power definitions and is independent of videokeratoscope design.

Cornea↗

Comparison of three videokeratoscopes in measurement of toric test surfaces.

PURPOSE: We compared the accuracy of the Computed Anatomy TMS-1 (1.41), the EyeSys Laboratories Corneal Analysis System (2.1), and the Visioptic EH-270 (3.0) videokeratoscopes in measuring toric surfaces. These non-rotationally symmetric aspheric surfaces served as models of corneal astigmatism. METHODS: Precision diamond-turned toric surfaces modeling 0.00 diopter (D) to 7.00 D of astigmatism were fabricated. A three-dimensional contact profiler was developed to calibrate the aspheric surfaces. Videokeratoscopic data taken at "best focus" were compared to the theoretical shape to quantify device measurement errors. RESULTS: The Computed Anatomy system measurement accuracy shows no statistically significant correlation between measurement error and surface toricity (r2 < 0.13). Measurement error increased linearly with surface astigmatism for the EyeSys Laboratories system (0.12 D rms error per D of astigmatism, r2 > 0.96, p < 0.001 and the Visioptic system (0.03 D error per D of astigmatism, r2 = 0.88, p < 0.001). CONCLUSIONS: This study found systematic performance differences among the three machines. Under ideal alignment conditions, the Computed Anatomy TMS-1 is more accurate at detecting astigmatism. The EyeSys Laboratories Corneal Analysis System apparently underestimates the amount of surface astigmatism because of excessive data smoothing. The Visioptic EH-270 errors are primarily in the central zones and may be due to ring localization errors.

Algorithms↗

Visual acuity modeling using optical raytracing of schematic eyes.

PURPOSE: We developed a methodology to predict changes in visual performance that result from changes in the optical properties of the eye. METHODS: Exact raytracing of schematic eyes was used to calculate the point spread function and the modulation transfer function of the visual system. The Stiles-Crawford effect, photopic response, diffraction, and the retinal contrast sensitivity are included in the model. Visual acuity was predicted by examining the modulation of the resultant retinal image of a bar target and by determining when the modulation falls below a threshold value. Visual acuity was predicted for refractive errors ranging from 0 to 5 diopters and for pupil diameters ranging from 0.5 to 8 mm. RESULTS: Visual acuity predictions were compared to clinically found Snellen visual acuities and were found to be highly correlated (r2 = .909). CONCLUSIONS: This modeling technique shows promise as a means of evaluating clinical and surgical procedures before undertaking clinical trails.

Contrast Sensitivity↗

Representation of videokeratoscopic height data with Zernike polynomials.

Videokeratoscopic data are generally displayed as a color-coded map of corneal refractive power, corneal curvature, or surface height. Although the merits of the refractive power and curvature methods have been extensively debated, the display of corneal surface height demands further investigation. A significant drawback to viewing corneal surface height is that the spherical and cylindrical components of the cornea obscure small variations in the surface. To overcome this drawback, a methodology for decomposing corneal height data into a unique set of Zernike polynomials is presented. Repeatedly removing the low-order Zernike terms reveals the hidden height variations. Examples of the decomposition-and-display technique are shown for cases of astigmatism, keratoconus, and radial keratotomy.

Cornea↗

Quantification of the Brückner test for strabismus.

PURPOSE: To measure quantitatively the change in the coaxial fundus reflex with varying degrees of ocular misalignment. METHODS: The coaxial fundus reflex was imaged with a charge coupled device camera under conditions of simulated ocular misalignment ranging from 0 degrees to 7 degrees of fixation eccentricity. The effects of refractive error and pupil size were controlled. Average gray scale brightness values were calculated for each bright pupil image after some image processing was performed on the raw images. RESULTS: A reliable, sharply delineated, minimum brightness at foveal fixation was observed. CONCLUSIONS: It is estimated that this technique can be automated to detect the presence of 2 degrees to 3 degrees of ocular misalignment based on the difference in brightness of the bright pupil images between the two eyes.

Adult↗

A low-cost computed tomographic scanner.

The authors describe a film-recorded computed tomographic (CT) scanner that uses optical processing methods for reconstruction of a sectional image. Results are comparable to commercial CT methods using the same patient dose. Consequently, clinically satisfactory CT imaging can be performed at a substantially reduced cost.

Animals↗