Search PubMed⌕ Search

Biomedical subjects

J E Bruce

Publications and source records attributed to J E Bruce.

At least 19 recordsLinked to original sources

Accurate mass multiplexed tandem mass spectrometry for high-throughput polypeptide identification from mixtures.

We report a new tandem mass spectrometric approach for the improved identification of polypeptides from mixtures (e.g., using genomic databases). The approach involves the dissociation of several species simultaneously in a single experiment and provides both increased speed and sensitivity. The data analysis makes use of the known fragmentation pathways for polypeptides and highly accurate mass measurements for both the set of parent polypeptides and their fragments. The accurate mass information makes it possible to attribute most fragments to a specific parent species. We provide an initial demonstration of this multiplexed tandem MS approach using an FTICR mass spectrometer with a mixture of seven polypeptides dissociated using infrared irradiation from a CO2 laser. The peptides were added to, and then successfully identified from, the largest genomic database yet available (C. elegans), which is equivalent in complexity to that for a specific differentiated mammalian cell type. Additionally, since only a few enzymatic fragments are necessary to unambiguously identify a protein from an appropriate database, it is anticipated that the multiplexed MS/MS method will allow the more rapid identification of complex protein mixtures with on-line separation of their enzymatically produced polypeptides.

Amino Acid Sequence↗

Protein identification with a single accurate mass of a cysteine-containing peptide and constrained database searching.

A method for rapid and unambiguous identification of proteins by sequence database searching using the accurate mass of a single peptide and specific sequence constraints is described. Peptide masses were measured using electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry to an accuracy of 1 ppm. The presence of a cysteine residue within a peptide sequence was used as a database searching constraint to reduce the number of potential database hits. Cysteine-containing peptides were detected within a mixture of peptides by incorporating chlorine into a general alkylating reagent specific for cysteine residues. Secondary search constraints included the specificity of the protease used for protein digestion and the molecular mass of the protein estimated by gel electrophoresis. The natural isotopic distribution of chlorine encoded the cysteine-containing peptide with a distinctive isotopic pattern that allowed automatic screening of mass spectra. The method is demonstrated for a peptide standard and unknown proteins from a yeast lysate using all 6118 possible yeast open reading frames as a database. As judged by calculation of codon bias, low-abundance proteins were identified from the yeast lysate using this new method but not by traditional methods such as tandem mass spectrometry via data-dependent acquisition or mass mapping.

Amino Acid Sequence↗

A novel high-performance fourier transform ion cyclotron resonance cell for improved biopolymer characterization.

A new trapped ion cell design for use with Fourier transform ion cyclotron resonance mass spectrometry is described. The design employs 15 cylindrical ring electrodes to generate trapping potential wells and 32 separately assignable rod electrodes for excitation and detection. The rod electrodes are positioned internal to the ring electrodes and provide excitation fields that are thereby linearized along the magnetic field over the entire trapped ion volume. The new design also affords flexibility in the shaping of the trapping field using the 15 ring electrodes. Many different trapping well shapes can be generated by applying different voltages to the individual ring electrodes, ranging from quadratic to linearly ramped along the magnetic field axis, to a shape that is nearly flat over the entire trap volume, but rises very steeply near the ends of the trap. This feature should be useful for trapping larger ion populations and extension of the useful range of ion manipulation and dissociation experiments since the number of stages of ion manipulation or dissociation is limited in practice by the initial trapped ion population size. Predicted trapping well shapes for two different ring electrode configurations are presented, and these and several other possible configurations are discussed, as are the predicted excitation fields based on the use of rod electrodes internal to the trapping ring electrodes. Initial results are presented from an implementation of the design using a 3.5 T superconducting magnet. It was found that ions can be successfully trapped and detected with this cell design and that selected ion accumulation can be performed with the utilization of four rods for quadrupolar excitation. The initial results presented here illustrate the feasibility of this cell design and demonstrate differences in observed performance based upon different trapping well shapes.

Biopolymers↗

Impact of body weight on urinary electrolytes in urinary stone formers.

OBJECTIVES: Obesity increases the risk of developing chronic medical conditions such as diabetes mellitus, hypertension, and coronary artery disease. We performed a retrospective review of a large data base on urinary stones to determine if differences are found in urine and serum chemistries among obese and nonobese stone-forming patients. The effect of body weight on stone recurrence among urinary stone formers was also determined. METHODS: A national data base containing serum biochemical profiles, 24-hour urine specimens, and standardized questionnaires was retrospectively evaluated from 5942 consecutive patients with urinary stone disease. Stone-forming patients were classified by body weight: nonobese men, less than 100 kg and nonobese women, less than 85 kg; intermediate men, 100 to 120 kg and intermediate women, 85 to 100 kg; and obese men, more than 120 kg and obese women, more than 100 kg. RESULTS: Obese stone formers comprised 6.8% (n = 404) of the patient population. The mean weight in the nonobese and obese groups was 81 kg versus 134 kg, respectively, for men and 64 kg versus 112 kg, respectively, for women. Obese patients represented 3.8% of the male and 12.6% of the female population. Obese patients had increased urinary excretion of sodium, calcium, magnesium, citrate, sulfate, phosphate, oxalate, uric acid, and cystine; obesity was associated with increased urinary volumes and urine osmolality compared with the nonobese patients. Obese men had increased concentration of urinary sodium, oxalate, uric acid, sulfate, and phosphate when corrected for urinary volume. Obese women had increased concentrations of sodium, uric acid, sulfate, phosphate, and cystine. The mean number of stone episodes in nonobese versus obese men was similar (3.55 and 3.56), whereas mean stone episodes were 2.93 and 3.38 (P = 0.045) for nonobese versus obese women. CONCLUSIONS: Among known stone formers, obesity is associated with unique changes in both serum and urinary chemistries. These changes are associated with an increased incidence of urinary stone episodes in obese women but not in obese men.

Adolescent↗

Obtaining more accurate Fourier transform ion cyclotron resonance mass measurements without internal standards using multiply charged ions.

Space-charge effects produce frequency shifts in Fourier transform ion cyclotron resonance (FTICR) mass spectrometry and correction for these shifts is necessary for obtaining accurate mass measurements. We report a novel method for obtaining accurate mass calibration to correct for space-charge induced mass shifts without the requirement for internal calibrants. The new approach is particularly well suited for electrospray ionization-FTICR mass spectra that contain multiple charge states of the same molecular species. This method, deconvolution of Coulombic affected linearity (DeCAL), is described and presented with several examples demonstrating the increased mass measurement accuracy obtained. DeCAL provides the basis for more routinely obtaining higher mass accuracy measurements in conjunction with chromatographic separations for complex mixture analysis, and obviates the need for internal calibration in many applications.

Algorithms↗

Linkage of type II and type III cystinuria to 19q13.1: codominant inheritance of two cystinuric alleles at 19q13.1 produces an extreme stone-forming phenotype.

Cystinuria, a renal tubule disease affecting urinary cystine excretion with or without kidney stone formation, previously was mapped to chromosome region 2p.21. Mutations in the gene SLC3A1 or NBAT, the reported candidate gene for cystinuria at 2p.21, have been demonstrated in individuals with the autosomal recessive Type I cystinuria phenotype. Recently, the Type III cystinuria phenotype was mapped to chromosome region 19q13.1. Here we report a kindred of 39 persons in two families of cystinurics, Types II and III, that support linkage to 19q13.1 and exclude 2p.21. Based on a dominant model of inheritance, two-point analysis of the entire pedigree produced a maximum lod score (Z(max)) of 3.82 at marker D19S425. Multipoint analysis yielded a lod score of 4.96 at this marker, and a resultant lod score of 5.90 using a codominant model of inheritance. Furthermore, a candidate gene interval of 8.9 cM, flanked by markers D19S225 and D19S223, was obtained using multipoint and haplotype analyses. Thus, this kindred demonstrates the linkage of Type II cystinuria to 19q13.1 and confirms the linkage of Type III cystinuria at 19q13.1 while excluding the marker D19S225 that was previously included in the critical interval.

Adolescent↗

High-mass-measurement accuracy and 100% sequence coverage of enzymatically digested bovine serum albumin from an ESI-FTICR mass spectrum.

The application of Fourier transform ion cyclotron resonance (FTICR) mass spectrometry to the analysis of polypeptide mixtures resulting from proteolytic digestion is described. A new 11.5-T FTICR mass spectrometer has been applied for the analysis of tryptic digestion mixtures of the protein bovine serum albumin (BSA). The improved cyclotron frequency stability and reduced frequency shifts observed over a wide range of trapped ion population sizes provide the ability to signal average spectra without degrading mass measurement accuracy, requiring internal calibration or advanced data processing schemes to compensate for variations in ion cyclotron signals brought about by different population sizes. A total of 100 spectra were signal-averaged leading to the observation of a total of 123 isotope distributions with a signal-to-noise ratio greater than 3:1. From those distributions, 86 can be ascribed to tryptic fragments of BSA on the basis of mass measurement errors of 10 ppm or less. Of these, 71 were within 2 ppm error limits corresponding to complete amino acid sequence coverage and an average error of 0.77 ppm. These results indicate that high-accuracy measurements are feasible for a large number of species detected simultaneously without the necessity for internal calibration and indicate the potential of such measurements, when combined with chromatographic separations, for facilitating more rapid identification of large numbers of proteins.

Amino Acid Sequence↗

Probing proteomes using capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Unlike the genome, the proteome is exquisitely sensitive to cellular conditions and will consist of proteins having abundances dependent upon stage in the cell cycle, cell differentiation, response to environmental conditions (nutrients, temperature, stress etc.), or disease state(s). Therefore, the study of proteomes under well-defined conditions can provide a better understanding of complex biological processes and inference of protein function. Thus, much faster, more sensitive, and precise capabilities for the characterization of cellular constituents are desired. We describe progress in the development and initial application of the powerful combination of capillary isoelectric focusing (CIEF) and Fourier transform ion cyclotron resonance (FTICR) mass spectrometry for measurements of the proteome of the model system Escherichia coli. Isotope depletion of the growth media has been used to improve mass measurement accuracy, and the comparison of CIEF-FTICR results for the analysis of cell lysates harvested from E. coli cultured in normal and isotopically depleted media are presented. The initial studies have revealed 400-1000 putative proteins in the mass range 2-100 kDa from total injections of approximately 300 ng of E. coli proteins in a single CIEF-FTICR analysis.

Bacterial Proteins↗

In-trap cleanup of proteins from electrospray ionization using soft sustained off-resonance irradiation with fourier transform ion cyclotron resonance mass spectrometry.

Electrospray ionization Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is capable of producing high mass resolving power and improved mass accuracy for large proteins and noncovalent complexes when coupled with collisionally induced dissociation (CID) of noncovalent adducts and consequent minimization of ion charge density in the ICR trap during measurements. This work demonstrates the application of in-trap cleanup to several biologically relevant systems, including carbonic anhydrase, 4-oxalocrotonate tautomerase (4OT) analogue, and SecB, a chaperone from Escherichia coli. In-trap cleanup yields improved mass measurements for these systems and is expected to further enable measurements for even more complex systems where adduction levels have precluded study of intact complexes.

Bacterial Proteins↗

The observation of chaperone-ligand noncovalent complexes with electrospray ionization mass spectrometry.

Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) was applied for the study of noncovalent chaperone SecB-ligand complexes produced in solution and examined in the gas phase with the aid of electrospray ionization (ESI). Since chaperone proteins are believed to recognize and bind only with ligands with nonnative tertiary structure, this work required careful unfolding of the ligand and subsequent reaction with the intact chaperone (the noncovalent tetrameric protein, SecB). A high denaturant concentration was employed to produce nonnative structures of the OppA, and microdialysis of the resulting solutions containing the chaperone-ligand complexes was carried out to rapidly remove the denaturant prior to analysis. Multistage mass spectrometry was essential to the successful study of these complexes since the initial mass spectra indicated extensive adduction that precluded mass measurements, even after microdialysis. However, low energy collisional activation of the ions in the FTICR trap proved useful for adduct removal, and careful control of excitation level preserved the intact complexes of interest, revealing a 1:1 SecB:OppA stoichiometry. To our knowledge, these results present the first direct observation of chaperone-ligand noncovalent complexes and the highest molecular weight heterogeneous noncovalent complex observed to date by mass spectrometry. Furthermore, these results highlight the capabilities of FTICR for the study of such complex systems, and the development of a greater understanding of chaperone interactions in protein export.

Bacterial Proteins↗

The interaction between the chaperone SecB and its ligands: evidence for multiple subsites for binding.

The chaperone protein SecB is dedicated to the facilitation of export of proteins from the cytoplasm to the periplasm and outer membrane of Escherichia coli. It functions to bind and deliver precursors of exported proteins to the membrane-associated translocation apparatus before the precursors fold into their native stable structures. The binding to SecB is characterized by a high selectivity for ligands having nonnative structure but a low specificity for consensus in sequence among the ligands. A model previously presented (Randall LL, Hardy SJS, 1995, Trends Biochem Sci 20:65-69) to rationalize the ability of SecB to distinguish between the native and nonnative states of a polypeptide proposes that the SecB tetramer contains two types of subsites for ligand binding: one kind that would interact with extended flexible stretches of polypeptides and the other with hydrophobic regions. Here we have used titration calorimetry, analytical ultracentrifugation, and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry to obtain evidence that such distinguishable subsites exist.

Aprotinin↗

Electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry at 11.5 tesla: instrument design and initial results.

Initial results obtained using a new electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer operated at a magnetic field 11.5 tesla are presented. The new instrument utilized an electrostatic ion guide between the ESI source and FTICR trap that provided up to 5% overall transmission efficiency for light ions and up to 30% efficiency for heavier biomolecules. The higher magnetic field in combination with an enlarged FTICR ion trap made it possible to substantially improve resolving power and operate in a more robust fashion for large biopolymers compared to lower field instruments. Mass resolution up to 10(6) has been achieved for intermediate size biopolymers such as bovine ubiquitin (8.6 kDa) and bovine cytochrome c (12.4 kDa) without the use of frequency drift correction methods. A mass resolution of 370,000 has been demonstrated for isotopically resolved molecular ions of bovine serum albumin (66.5 kDa). Comparative measurements were made with the same spectrometer using a lower field 3.5-tesla magnet allowing the performance gains to be more readily quantified. Further improvements in pumping capacity of the vacuum system and efficiency of ion transmission from the source are expected to lead to further substantial sensitivity gains.

Algorithms↗

A dual-trap design and its applications in electrospray ionization FTICR mass spectrometry.

A new arrangement consisting of two separate Fourier transform ion cyclotron resonance (FTICR) ion traps was used to develop methods for the manipulation of the ions produced by an electrospray ionization source (ESI). A first, "accumulation" trap, is generally maintained at a higher pressure than the second, high-performance "analyzer" trap. The manipulations developed and demonstrated include the following: (1) mass-selective ion transfers between the traps; (2) mass-selective step-wise accumulation of low-abundance ions of different mass-to-charge ratios transferred from the first trap to the analyzer trap; (3) simultaneous detection of ions in the analyzer trap and ion accumulation in the source trap; (4) simultaneous ion detection in the accumulation trap and ion storage in the analyzer trap; (5) sequential multiple transfers of the ions into the analyzer trap from the same ion population stored in the accumulation trap; (6) collision-induced dissociation of ions stored in the accumulation trap followed by mass-selective transfer of the product ions into the analyzer trap; (7) sequential transfer of the ions of different mass-to-charge ratios into the analyzer trap from the same ion population stored in the accumulation trap followed by the collision-induced dissociation of transferred ions in the analyzer trap. These ion manipulations benefit multistage studies and are projected to be useful in many biochemical applications of ESI-FTICR, including structural determination of biopolymers and study of noncovalent complexes.

Cyclotrons↗

Geriatric urolithiasis.

PURPOSE: We define the differences between geriatric patients with urinary stone disease compared to a younger cohort. MATERIALS AND METHODS: A data base, including serum biochemical profiles, 24-hour urinalyses and standardized questionnaires, was retrospectively evaluated from more than 6,000 consecutive patients with urinary stone disease. RESULTS: Geriatric stone formers comprised 12% (721) of all stone patients. Two-thirds of these elderly patients had aberrant urinary values and 29% had isolated hypocitraturia compared to 17% in the younger group. Of geriatric stone forming patients 76% had recurrent urinary stones (mean 3.5 stone episodes), which was similar to the younger comparable group (77%, mean 3.3 stone episodes). The severity of urinary stone disease was similar between the 2 groups based on the need for urological intervention. Geriatric stone patients, in general, experienced the first stone episode later in life (after age 50 years) compared with younger patients. Elderly patients had an increased incidence of uric acid stones, but had a similar incidence of struvite calculi. Geriatric stone patients underwent parathyroid surgery more frequently (2.7 versus 0.7%). Geriatric stone forming patients rarely had renal failure. CONCLUSIONS: The incidence, recurrence and severity of recurrent urinary stone disease were similar between geriatric and younger stone forming patients. Geriatric stone patients had an increased incidence of isolated hypocitraturia, uric acid calculi and previous parathyroidectomy. The geriatric stone population is not merely an extension of younger stone forming patients presenting at an older age. Rather, geriatric patients commonly experience the first symptomatic stone episode later in life.

Age Distribution↗

Mass spectrometric characterization of sequence-specific complexes of DNA and transcription factor PU.1 DNA binding domain.

Electrospray ionization mass spectrometry (ESI-MS) has been used to study the noncovalent interaction of the 13.5-kDa DNA binding domain of PU.1 (PU.1-DBD) with specific double-stranded DNA (dsDNA) target molecules. Mixtures of PU.1-DBD protein and wild-type target DNA sequence yielded ESI-MS spectra showing only protein-dsDNA complex ions of 1:1 stoichiometry and free dsDNA. When PU.1-DBD protein, wild type target DNA, and a mutant target DNA lacking the consensus sequence were mixed, only the 1:1 complex with the wild-type DNA was observed, consistent with gel electrophoresis mobility shift assay results, demonstrating the observation of sequence-specific protein-dsDNA complexes using ESI-MS.

Binding Sites↗

Molecular weight determination of plasmid DNA using electrospray ionization mass spectrometry.

Ionization and molecular weight (MW) determination of megadalton size plasmid DNA has been achieved using electrospray ionization (ESI) with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. DNA molecules were shown to remain intact through electrospray ionization by collection on a specially prepared surface, followed by agarose gel electrophoresis. Individual highly charged ions of plasmid DNA produced by ESI were trapped in an FTICR cell for up to several hours and reacted with acetic acid to induce charge state shifts. Measurements of mass-to-charge ratios for these multiple peaks arising from charge state shifting give MW measurements of individual ions with an average accuracy of 0.2%. The MW distribution was obtained by measurements for a number of individual ions from the same sample [plasmid DNA: pGEM-5S MW(cal) = 1.946 MDa], yielding a MW(obs) of 1.95 +/- 0.07 MDa for ions clustered in the vicinity of the expected MW.

Cyclotrons↗

Screening derivatized peptide libraries for tight binding inhibitors to carbonic anhydrase II by electrospray ionization-mass spectrometry.

This paper describes the use of electrospray ionization-mass spectrometry (ESI-MS) to screen two libraries of soluble compounds to search for tight binding inhibitors for carbonic anhydrase II (EC 4.2.1.1). The two libraries, H2NO2SC6H4C(O)NH-AA1-AA2-C(O)NHCH2CH2CO2H where AA1 and AA2 are L-amino acids (library size: 289 compounds) or D-amino acids (256 compounds), were constructed by attaching tripeptides to the carboxyl group of 4-carboxybenzenesulfonamide. Screening of both libraries yielded, as the tightest binding inhibitor, compound 1 (AA1 = AA2 = L-Leu; binding constant Kb = 1.4 x 10(8) M-1). The ability of ESI-MS to estimate simultaneously the relative binding affinities of a protein to soluble ligands in a library, if general, should be useful in drug development.

Amino Acid Sequence↗

"Colored" noise waveforms and quadrupole excitation for the dynamic range expansion of Fourier transform ion cyclotron resonance mass spectrometry.

Fourier transform ion cyclotron resonance (FTICR) mass spectrometry offers unparalleled analytical performance in most regards but has a dynamic range of typically no better than 10(2)-10(3). This limitation reportedly arises from two opposing constraints, involving the maximum number of ions that can be effectively trapped (10(6)-10(7)) and the minimum number of ions required to produce a detectable signal (10(2)-10(3)). A potential solution to this dynamic range limitation is presented, based on the application of selected-ion accumulation using quadrupole excitation. We show that lower concentration species can be effectively accumulated in the FTICR trapped ion cell, while the more abundant species are continually removed by the application of quadrupolar excitation in the form of band-limited or "colored" noise waveforms. The result is that "room" is made in the cell for lower abundance species, even during extended accumulation periods. This approach was demonstrated with mixtures of the bovine proteins, insulin, ubiquitin, and cytochrome c. For normal accumulation, the dynamic range was approximately 100. The application of selected-ion accumulation in the form of colored noise allowed the extension by 2 orders of magnitude and the detection of species of 1 x 10(-8) M concentration from a solution also containing another component at 9 x 10(-5) M. With this method, a putative new low abundance variant of bovine insulin was observed, and selected-ion accumulation and subsequent collisionally activated dissociation were used for its identification. Dipolar magnetron excitation was also explored to enhance selected-ion accumulation and was found to reduce the amount of buffer gas required for complete removal of the undesired species by a factor of 5. Further possible improvements are discussed, as are the complications due to the required balance between magnetron and cyclotron damping rates.

Amino Acid Sequence↗