Search PubMed⌕ Search

Biomedical subjects

J E Bos

Publications and source records attributed to J E Bos.

At least 19 recordsLinked to original sources

Motion sickness and tilts of the inertial force environment: active suspension systems vs. active passengers.

BACKGROUND: Maneuvering in vehicles exposes occupants to low frequency forces (< 1 Hz) which can provoke motion sickness. HYPOTHESIS: Aligning with the tilting inertial resultant (gravity + imposed horizontal acceleration: gravito-inertial force (GIF)) may reduce motion sickness when tilting is either 'active' (self-initiated; Experiment 1) or 'passive' (suspension machinery; Experiment 2). METHODS: Exp 1: Twelve seated subjects were exposed to continuous horizontal translational oscillation through the body x-axis (3.1 m x S(-2) peak acceleration, 0.20 Hz) while making head tilts which were either aligned or misaligned (180 degrees out of phase) with respect to GIF. The two sessions were one week apart at the same time of day, counterbalanced for order. Head tilts were controlled by tracking a moving LED display and head trajectory was verified by accelerometry. Motion continued until moderate nausea was achieved (motion endpoint) or until a 30 min cut-off. Exp 2: A different group of 12 subjects were exposed to continuous horizontal translational sinusoidal oscillation through the body x-axis (2.0 m x S(-2) peak acceleration, 0.176 Hz) while seated in a cab which was tilted by suspension machinery around the y-axis of the ears so that GIF was aligned or misaligned (180 degrees out of phase) with the body z-axis. RESULTS: Exp 1: Mean +/- SD time to motion endpoint was significantly longer for aligned (19.2 +/- 12.0 min) than for misaligned (17.8 +/- 13.0 min; p < 0.05, two-tail). Exp 2: Mean +/- SD time to motion endpoint was significantly shorter for aligned (21.8 +/- 10.9 min) than for misaligned (28.3 +/- 5.8 min; p < 0.01, two-tail). CONCLUSIONS: Whether or not compensatory tilting protects against (Exp 1) or contributes to (Exp 2) motion sickness may be influenced by whether the tilting is under the active control of the person (e.g., car driver) or under external control (e.g., passenger in a high-speed tilting train).

Adult↗

Eye movements to yaw, pitch, and roll about vertical and horizontal axes: adaptation and motion sickness.

BACKGROUND: In the search for parameters to predict motion sickness that can be measured in the laboratory, we performed a longitudinal investigation in aviators. Since the vestibular system is involved in the generation of motion sickness as well as eye movements, vestibulo-ocular reflex (VOR) parameters seemed relevant. We investigated three topics: 1) the effect of axis orientation and its orientation to gravity on the VOR; 2) changes in VOR parameters depending on flight experience; and 3) differences in VOR parameters in aircrew with high and low susceptibility to motion sickness. HYPOTHESIS: Nystagmus decay after angular velocity steps would be faster for non-susceptible and trained aviators. METHODS: We recorded eye movements evoked by angular on-axis velocity steps (+/- 90 degrees x S(-2), to and from 90 degrees x S(-1)) in yaw, pitch, and roll, about both the Earth vertical and Earth horizontal axes in 14 subjects with a low susceptibility to motion sickness. These data were compared with those of 10 subjects with a high susceptibility. RESULTS: Horizontal axis rotations are nauseogenic. We found that during (per) and post-condition, left- and rightward rotation responses were equal, and the orientation with respect to gravity did not alter the basic nystagmus decay, apart from a sinusoidal modulation. Moreover, pitch and roll rotations show equal nystagmus decays, significantly faster than for yaw; yaw and pitch peak velocities were equal and were larger than for roll. With regard to changes in VOR parameters depending on flight experience, we found that repeated vestibular stimulation reduced nystagmus decay as well as the otolith modulation. With respect to the changes in VOR parameters and motion sickness susceptibility, we found that subjects highly susceptible to motion sickness showed a slower decay of nystagmus with a larger peak velocity than less susceptible subjects. CONCLUSIONS: Group averages indicate a difference in eye movement parameters, only in yaw, depending on flight experience; and between subjects with low and high susceptibility to motion sickness. The involvement of the velocity storage mechanism as realized by an internal model is given as a plausible explanation.

Adaptation, Physiological↗

Motion sickness.

The number of recently published papers on motion sickness may convey the impression that motion sickness is far from being understood. The current review focusses on a concept which tends to unify the different manifestations and theories of motion sickness. The paper highlights the relations between ergonomic principles to minimise motion sickness and the concept predictions. The clinical management of sufferers from motion sickness in terms of selection, pharmacological measures and desensitisation courses is treated as well.

Humans↗

Contribution of the otoliths to the human torsional vestibulo-ocular reflex.

The dynamic contribution of the otolith organs to the human ocular torsion response was examined during passive sinusoidal body roll about an earth-horizontal axis (varying otolith inputs) and about an earth-vertical axis (invariant otolith inputs). Torsional eye movements were registered in 5 subjects by means of video-oculography. At a fixed amplitude of 25 degrees, the stimulus frequency was varied from 0.05 to 0.4 Hz. Additionally, at a fixed frequency of 0.2 Hz, the response was also measured at the amplitudes to 12.5 degrees and 50 degrees. The results showed that the gain and phase of the torsional slow component velocity (SCV) did not depend on stimulus amplitude, indicating a linear response. Contribution of the otoliths affected the ocular torsion response in three different ways. First, the gain of the SCV was slightly, but consistently, higher during rotation about an earth-horizontal axis than during rotation about an earth-vertical axis. With invariant otolith inputs the average gain increased from 0.10 at 0.05 Hz to 0.26 at 0.25 Hz. With varying otolith inputs, the average gain increased from 0.14 to 0.37. Second and more substantially, contribution of the otoliths improved the response dynamics by reducing the phase lead at frequencies up to 0.02 Hz. Third, the nystagmus showed considerably less anticompensatory saccades in upright conditions than in supine conditions, even though the SCV gain was lower in the latter. As a consequence, the average excursion of torsional eye position was highest during earth-horizontal rotation. This effect was observed in the entire frequency range. Thus, the otoliths controlled the human torsional VOR not only at low stimulus frequencies by keeping the slow component in phase with head motion, but also in a wider frequency range by modulating the saccadic behavior as to increase the amplitude of ocular torsion. We conclude that the primary concern of the otolith-oculomotor system during head tilt is to stabilize eye position in space, rather than to prevent retinal blur.

Adult↗

Modelling motion sickness and subjective vertical mismatch detailed for vertical motions.

In an attempt to predict the amount of motion sickness given any kind of motion stimulus, we describe a model using explicit knowledge of the vestibular system. First, the generally accepted conflict theory is restated in terms of a conflict between a vertical as perceived by the sense organs like the vestibular system and the subjective vertical as determined on the basis of previous experience. Second, this concept is integrated with optimal estimation theory by the use of an internal model. If detailed for vertical motions only, the model does predict typical observed motion sickness characteristics, irrespective the parameter setting. By adjusting the nonvestibular parameters, the model can also quantitatively be adapted to seasickness data from the literature. With this concept, sickness severity hypothetically can also be predicted for other motions, irrespective of their origin and complexity.

Conflict, Psychological↗

Contributions of roll and pitch to sea sickness.

The purpose of this study was to test the traditional assumption that sea sickness is uniquely provoked by heave motion characteristics, with pitch and roll movements being ineffective. In an experiment with a ship motion simulator, subjects were exposed to pitch and roll motions in combination with rather weak heave motions that have no motion sickness-inducing potential. Very high levels of motion sickness were observed (with a motion sickness rating scale) in almost 50% of our subjects. In three control experiments, it was shown that these heave motions, when presented separately, indeed have no motion sickness-inducing potential and that pitch and roll motions presented alone or in combination with each other have only a very small motion sickness-inducing potential. These results indicate that pitch and roll when combined with small heave motions, which in themselves are not sickness provoking, produce more motion sickness than claimed by the classic models. This suggests that in models on motion sickness, pitch and roll should be combined in a nonlinear fashion with heave and that such models will remain rather crude if they do not include a description of the vestibular contribution to motion sickness.

Adaptation, Physiological↗

Motion sickness amelioration induced by prism spectacles.

A side effect of the prescription of prism glasses according to the principle of Utermöhlen to improve mechanical reading skills of certain types of learning disabled children was the alleviation of car sickness. Besides a decrease in reported symptoms after prescription of these glasses, the effect is quantified by a decrease in estimated number of emeses per year per patient. A placebo effect is unlikely because alleviation of car sickness was not the original intention of the prescription, and the symptoms returned as soon as the spectacles were discontinued.

Adolescent↗

Motion sickness: only one provocative conflict?

In reviewing the various forms of motion sickness, the classic sensory rearrangement theory has been redefined by demonstrating that only one type of conflict is necessary and sufficient to explain all different kinds of motion sickness. A mathematical description is provided from the summarizing statement that "All situations which provoke motion sickness are characterised by a condition in which the sensed vertical as determined on the basis of integrated information from the eyes, the vestibular system and the nonvestibular proprioceptors is at variance with the subjective vertical as expected from previous experience."

Computer Simulation↗

Roll motion stimuli: sensory conflict, perceptual weighting and motion sickness.

In an experiment with 17 subjects, interactions of visual roll motion stimuli and vestibular body tilt stimuli were examined in determining the subjective vertical. Interindividual differences in weighting the visual information were observed, but in general, visual and vestibular responses added in setting the vertical. Despite the conflicting sensory information, motion sickness was not reported apart from one subject on one single occasion. This is in conflict with the sensory mismatch theory on motion sickness, but in agreement with the subjective vertical conflict theory.

Conflict, Psychological↗

Cervically induced ocular torsion: physiological and clinical aspects.

Ocular torsion was measured in five subjects during sinusoidal lateral tilt (amplitude 25 degrees, 0.2 Hz). The cervical contribution to ocular torsion was best visible as the difference between the signals obtained in conditions with only head tilt and conditions with whole body tilt. Contribution of the neck did not affect the slow component, but produced an anticompensatory modulation of the beating field offset by means of saccades (analogous to gaze shift). Static tilt conditions (25 degrees tilt) of the trunk only, the head only or the whole body showed similar data, although of smaller amplitude. The results from patients suffering from post-whiplash syndrome were similar to those of healthy subjects, showing large intersubject variability. The reduced tolerance to head tilt of whiplash patients restricts useful implementation of this sort of test in the clinic.

Adult↗

A sustained hyper-g load as a tool to simulate space sickness.

In April 1989 the three European scientist astronauts of the D1 Spacelab Mission were exposed to a 1.5 hours +3G centrifuge run in supine position, resulting in a linear acceleration along the subjects' x-axis. Afterwards, severe motion sickness symptoms were provoked by head movements (Sickness Induced by Centrifugation: SIC). The astronauts mentioned close similarities with what they experienced in space during the D1-Spacelab Mission in 1985, where head movements also provoked motion sickness symptoms (Space Adaptation Syndrome: SAS). Moreover, the astronauts agreed that the rank order of their susceptibility to SAS was the same as for SIC. It was therefore postulated that with this method SAS could be simulated on earth. Additionally, in otolith function tests following the centrifuge run, changes in visual-vestibular interaction were observed, which replicated objective findings obtained with the same astronauts immediately after the D1 Spacelab Mission. During the last couple of years a series of experiments has been carried out to determine the nature of the stimulus causing SIC, the incidence of SIC, and the underlying cardio-vascular and/or vestibular mechanisms. These experiments were carried out on several astronauts and some 50 'normal' healthy subjects. In the next sections the main findings of all these experiments and the implications are summarized.

Acceleration↗

Ocular torsion before and after 1 hour centrifugation.

To assess a possible otolith contribution to effects observed following prolonged exposure to hypergravity, we used video oculography to measure ocular torsion during static and dynamic conditions of lateral body tilt (roll) before and after 1 h of centrifugation with a Gx-load of 3 G. Static tilt (from 0 to 57 degrees to either side) showed a 10% decrease in otolith-induced ocular torsion after centrifugation. This implies a reduced gain of the otolith function. The dynamic condition consisted of sinusoidal body roll (frequency 0.25 Hz, amplitude 45 degrees) about an earth horizontal and about an earth vertical axis (respectively, "with" and "without" otolith stimulation). Before centrifugation the gain of the slow component velocity (SCV) was significantly lower "with" otolith stimulation than "without" otolith stimulation. Apparently, the contribution of the otoliths counteracts the ocular torsion response generated by the semicircular canals. Therefore, the observed increase in SCV gain in the condition "with" otolith stimulation after centrifugation, seems in correspondence with the decreased otolith gain in the static condition.

Adult↗

Saccular impact on ocular torsion.

When someone is tilted laterally, the shear force on the maculae of the utriculus and the sacculus is described by the sine and the cosine of the angle of tilt, respectively. So both the sacculus and the utriculus are stimulated, but in the literature, ocular torsion is normally attributed to utricular function alone (and, thus, seen as a response to y-axis linear acceleration). However, on the base of a series of experiments on a tilt chair, a linear track, human centrifuges, and during parabolic flights, we conclude that the sacculus contributes to ocular torsion as well (there is a response to z-axis linear acceleration). The data suggest that the ratio of the utricular and saccular impact on ocular torsion is 3:1. The utriculus generates conjugate and the sacculus disjunctive torsional eye movements.

Adult↗

Determination of ocular torsion by means of automatic pattern recognition.

A new, automatic method for determination of human ocular torsion (OT) was developed based on the tracking of iris patterns in digitized video images. Instead of quantifying OT by means of cross-correlation of circular iris samples, a procedure commonly applied, this new method automatically selects and recovers a set of 36 significant patterns in the iris by the technique of template matching as described by In den Haak et al. Each relocated landmark results in a single estimate of the torsion angle. A robust algorithm estimates OT from this total set of individually determined torsion angles, thereby largely correcting for errors which may arise due to misjudgement of the rotation center. The new method reproduced OT in a prepared set of images of an artificial eye with an accuracy of 0.1 degree. In a sample of 256 images of human eyes, a practical reliability of 0.25 degrees was achieved. To illustrate the method's usefulness, an experiment is described in which ocular torsion was measured during two dynamic conditions of whole-body roll, namely during sinusoidally pendular motion about either an earth horizontal or earth vertical axis (that is "with" and "without" otolith stimulation, respectively).

Algorithms↗

Arthrokinetic and vestibular information enhance smooth ocular tracking during linear (self-)motion.

We studied the gain of smooth ocular tracking for visual, vestibular and arthrokinetic cues, in combination as well as separately, in order to examine how these multisensory cues influence tracking performance. By use of motion along a linear track (besides the self-evident visual influence) evidence was found for arthrokinetic and vestibular enhancement of smooth ocular tracking. These results were in close correspondence with the results of our former study about arthrokinetic influence on linear self-motion perception. Therefore, we conclude that information from the limbs about linear (self-)movement has analogous characteristics and generates analogous responses to the information about angular (self-)movement.

Analysis of Variance↗

Ocular torsion quantification with video images.

The present paper describes a technique to quantify eye rotations about the visual axis (ocular torsion). Two digitized polar transformed images of the iris are displayed on a video monitor in order to facilitate a visual comparison and manual interaction. Emphasis is placed on error analysis and the method's simplicity when applied to static ocular torsion measurement. The implementation, applying averaging over ocular torsion determined in partitioned iris images, yields a theoretical resolution of 5' of arc. In a control experiment with an artificial eye, the accuracy showed to be better than 14' of arc. In practice, the measuring device was validated with the data from the literature by means of an experiment about ocular torsion in humans during tilt and hypergravity conditions (up to 3 g).

Bias↗

Assessment of pupillary responses to light with IRIS.

With a newly developed method, IRIS, the potential usefulness of various parameters of pupillary reflexes for the assessment of autonomic nerve function was studied. Constriction latency decreased and dilatation latency increased significantly with higher intensities of light (P < 0.01 and P < 0.05, respectively). Thirteen subjects were tested twice one year apart in order to examine long-term intra-individual variability; no significant differences (all P > 0.3) were found. Reproducibility and reliability of hippus and pupil cycle time were lower than for the determination of constriction and dilatation latency. None of the parameters was correlated with age (all P > 0.3). We conclude that pupillary constriction and dilatation latency, assessed with IRIS, are the main dynamical parameters for the study of parasympathetic and sympathetic parts of the autonomic nervous system, that controls the pupillary system. Although a statical parameter, useful additional information may be obtained from the dark adapted pupil diameter. Hippus cycle time and pupil cycle time do not provide additional information and therefore cannot be recommended as standard tests for autonomic nerve function.

Adult↗