Polycyclic aromatic hydrocarbons in food samples collected in Barcelona, Spain.

This study reports on the concentrations of eight polycyclic aromatic hydrocarbons (PAHs) in food samples collected in the city of Barcelona (Catalonia, Spain) from 2003 to 2004. Food samples included meat products, fish (fresh and smoked), other seafood (cephalopods, crustaceans, and bivalves), vegetable oil, and tea. Concentrations of benz[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[g,h,i]perylene, benzo[alpha]pyrene, benzo[e]pyrene, dibenz[a,h]anthracene, and indeno[1,2,3-c,d]pyrene were determined by reversed-phase high-performance liquid chromatography with fluorescence detection. PAHs were detected in most tea samples (94%), which had the highest concentration of total PAHs (mean concentration of 59 microg/kg). Other food groups with a high presence of PAHs were bivalves (present in 34% of the samples; mean value of 2.7 microg/kg) and meat products (present in 13% of the samples; mean value of 1.7 microg/kg). The PAHs detected most frequently were benzo[e]pyrene and benzo[b]fluoranthene. No sample had levels above current regulation standards. Nevertheless, the frequent presence of PAHs in bivalves, tea samples, and meat products, together with the fact that dietary sources are the main exposure to these carcinogenic compounds, suggests the need for some monitoring scheme to follow up on these trends.

Chromatography, High Pressure Liquid↗

[Protocol to evaluate automatic continuous positive airway pressure. Assessment of the usefulness of the Autoset-T device to determine optimal pressure for treating sleep apnea/hypopnea syndrome].

INTRODUCTION: Given the high prevalence of sleep apnea/hypopnea syndrome (SAHS) and great demand for conventional polysomnography (PSG) and long waiting lists, alternative means for diagnosing SAHS and titrating continuous positive airway pressure (CPAP) are needed. Automatic CPAP may play a role in meeting the last objective, not only for treatment but also for suggesting the optimum CPAP setting. OBJECTIVES: a) To define a protocol to assess the functioning of an automatic CPAP device by means of a mechanical model; b) to determine the behavior of automatically adjusted CPAP during PSG; c) to define the usefulness of automatic CPAP for indicating optimal CPAP pressure for patients with SAHS; d) to evaluate the efficacy of the automatically indicated pressure setting against conventional PSG. METHODS: Four protocols were carried out using the Autoset-T (AT) device. 1. Apneas, hypopneas, flow limitation, snoring and normal flow were simulated in a laboratory using a mechanical model in order to check AT functioning. 2. The behavior of the automatically adjusted CPAP was observed in real time during PSG in 12 patients with severe SAHS. 3. The agreement of CPAP titrated with the AT and with PSG was checked in a group of 39 patients with SAHS. 4. The efficacy of the CPAP pressure recommended by the AT was checked by PSG in a group of 14 patients with SAHS. RESULTS: With the AT, CPAP increased rapidly in response to apneas or snoring in the mechanical model and during conventional PSG; it took only a mean 2.8 3.1 min to rise from a baseline pressure of 4 cm H2O to a near-optimum pressure of 11 1 cm H2O. Once normal flow was reached CPAP slowly decreased, responding with great sensitivity to the slightest abnormality, especially snoring, but not changing in response to certain types of flow limitation. The pressure read visually on the AT was similar to the one recommended by PSG in most of the 39 patients (71%). The PSG performed after one month of using AT-recommended CPAP titration confirmed that the number of apneas, hypopneas (apnea/hypopnea index 6(1) and arousals (8 2) was normal for these SAHS patients. CONCLUSIONS: The AT increases pressure rapidly in the presence of respiratory events and maintains a normal breathing pattern in most patients. Visual reading of the AT pressure allows correct identification of the optimal CPAP setting for SAHS treatment.

Aged↗

Antibody screening in 37 degrees C saline. Is it safe to omit it using the indirect antiglobulin (gel) test?

Pretransfusion tests must detect antibodies that can shorten the life of red blood cells (RBCs). Some studies have demonstrated the existence of clinically significant antibodies detected at 37 degrees C in saline that are not detected by the indirect antiglobulin test (IAT) when the conventional tube test is used. Our aim was to determine whether these antibodies, detected with a 37 degrees C saline tube test, are also detected when a sensitive column gel agglutination method is used. The 2373 pretransfusion samples were tested as they were received (from May 1998 to December 1999), in 37 degrees C saline and by IAT using the DiaMed gel system. The screening tests were performed using 50 microL of 0.8% low-ionic-strength saline suspended RBCs and 50 microL of plasma. The tests were examined for agglutination and hemolysis. Two hundred and thirty three samples (9.81%) were reactive by IAT and 88 (3.70%) by 37 degrees C saline. All 88 samples reactive by 37 degrees C saline also reacted by IAT. These data indicate that 37 degrees C saline is not an essential pretransfusion procedure when the DiaMed gel test is used.

Journal Article↗

Rayleigh-Taylor instabilities in thin films of tapped powder.

We observe powder "droplets" forming when tapping repeatedly a horizontal flat plate initially covered with a monolayer of fine powder particles. Starting from a simple model involving both the air flow through the porous cake and avalanche properties, we set up an analytical model which satisfactorily fits the experimental results. We observe a close analogy between the governing equations of the phenomenon and the basic physics of wetting liquids, including the equivalent of the Laplace law and the surface tension parameter leading to the well known Rayleigh-Taylor instability.

Chemistry, Pharmaceutical↗

Effectiveness of continuous positive airway pressure in mild sleep apnea-hypopnea syndrome.

The aim of this trial was to evaluate the effectiveness of continuous positive airway pressure (CPAP) in patients with mild sleep apnea- hypopnea syndrome (SAHS). One hundred forty-two consecutive patients with mild SAHS (apnea-hypopnea index 10-30, without severe sleepiness) were randomly assigned to receive conservative treatment (CT)-sleep hygiene and weight loss-(65 patients) or CT plus CPAP (77 patients), and 125 patients (86% males, age: 54 +/- 9 yr, BMI: 29 +/- 4 kg/m(2), AHI: 20 +/- 6, ESS: 12 +/- 4) completed the follow-up. The following outcomes were assessed at inclusion and after 3 and 6 mo of treatment: sleepiness (Epworth scale, multiple sleep latency test [MSLT]), other symptoms related to SAHS, cognitive function, and perceived health status (Functional Outcomes of Sleep Questionnaire [FOSQ], Nottingham Health profile). The relief of SAHS-related clinical symptoms was significantly greater in the CPAP group than in the CT group; the Epworth scale and FOSQ also showed more improvement in the CPAP group but did not reach significance. There were no significant differences in the other tests performed probably because the baseline values were normal. CPAP compliance was 4.8 +/- 2.2 h and treatment continuation was accepted by 62% of the patients at the end of the study. These results suggest that CPAP can be considered in treating patients with mild SAHS on the basis of an improvement in symptoms.

Chi-Square Distribution↗

Treatment with continuous positive airway pressure is not effective in patients with sleep apnea but no daytime sleepiness. a randomized, controlled trial.

BACKGROUND: The sleep apnea-hypopnea syndrome is defined by a pathologic number of respiratory events during sleep (the apnea-hypopnea index, defined as the number of apnea and hypopnea episodes per hour) and daytime symptoms (mostly, excessive sleepiness). In patients with the sleep apnea syndrome, treatment with continuous positive airway pressure (CPAP) normalizes both the apnea-hypopnea index and diurnal symptoms. However, the effect of CPAP in persons with a pathologic apnea-hypopnea index without daytime sleepiness is unclear. OBJECTIVE: To investigate the short-term effects of CPAP on quality of life, objective sleepiness, cognitive function, and arterial blood pressure in nonsleepy patients with a pathologic apnea-hypopnea index. DESIGN: Multicenter randomized, placebo-controlled, parallel-group study. SETTING: Six teaching hospitals in Spain. PATIENTS: 55 patients with an apnea-hypopnea index of 30 or greater who did not have daytime sleepiness (Epworth Sleepiness Scale score </= 10). INTERVENTION: Patients were randomly assigned to receive optimal (n = 29) or sham (n = 25) CPAP and were observed for 6 weeks. MEASUREMENTS: Quality of life, objective sleepiness (Multiple Sleep Latency Test score), cognitive function, and arterial blood pressure. RESULTS: The intervention and control groups were similar in terms of mean (+/-SE) age (54 +/- 2 vs. 52 +/- 2 years), apnea-hypopnea index (54 +/- 3 vs. 57 +/- 4), Epworth Sleepiness Scale score (7.0 +/- 0.4 vs. 7.0 +/- 0.4) and adherence to CPAP treatment (5.0 +/- 0.4 vs. 4.0 +/- 0.5 hours/d). Other variables, such as quality of life, cognitive function, and arterial blood pressure, were also similar in both groups before treatment. After 6 weeks of CPAP or sham CPAP, none of these variables changed significantly. CONCLUSION: In patients with an apnea-hypopnea index of 30 or greater and no subjective daytime sleepiness, CPAP does not modify quality of life, objective sleepiness, vigilance, attention, memory, information processing, visuomotor coordination, or arterial blood pressure. Treatment with CPAP is therefore not indicated in nonsleepy patients with a pathologic apnea-hypopnea index.

Blood Pressure↗

Ripples in tapped or blown powder

We observe ripples forming on the surface of a granular powder in a container submitted from below to a series of brief and distinct shocks. After a few taps, the pattern turns out to be stable against any further shock of the same amplitude. We find that the wavelength of the pattern is proportional to the amplitude of the shocks. Starting from considerations involving air flow through the porous granulate and avalanche properties, we build up a semiquantitative model which satisfactorily fits the set of experimental observations of either tapped or blown powder.

Journal Article↗

Granular boycott effect: how to mix granulates.

Granular material can display the basic features of the Boycott effect in sedimentation. A simple experiment shows that granular material falls faster in an inclined tube than in a vertical tube, in analogy with the Boycott effect. As long as the inclination of the tube is above the avalanche threshold, descent of granular material in the tube causes internal convection which in turn results in an efficient mixture of the granular components. By contrast, as in analogous experiments in two dimensions, a vertical fall of granular material occurs via successive block fragmentation, resulting in poor mixing.

Journal Article↗

Influence of gender, race, and education on patient preferences and receipt of cardiac catheterizations among coronary care unit patients.

The extent to which a preference for less aggressive care explains the lower rate of invasive cardiac services for women and African-Americans is unknown. A prospective observational study of 272 patients admitted to the coronary care unit was conducted at a tertiary referral teaching hospital and a community teaching hospital. In stepwise multivariate analysis, having less than a college education, poor cardiac function, not having undergone a previous cardiac catheterization, being a patient in a nonreferral community hospital, and current smoking were positively associated with a patient's stating that he or she would disagree with a physician's recommendation for a cardiac catheterization. The step-wise multivariate model with cardiac catheterization as the dependent variable indicated that being a patient in a referral medical center, patient willingness to accept a physician's recommendation for a cardiac catheterization, severe heart disease, and having attended high school were predictive. Women did not differ from men in their preference for or receipt of cardiac catheterization. Patients in the coronary care unit with lower levels of education were less likely to undergo cardiac catheterization. This association was only partly explained by less educated patients' being less willing to accept a physician's recommendation to undergo cardiac catheterization.

Aged↗

Serum hemolytic and bactericidal activity in breast and formula-fed infants.

Whether formula or breast feeding influences the functional activity of the complement system from birth to three months of age has been studied. The classical pathway was evaluated by assessing hemolytic activity, based on the capacity of the intact complement system to lyse sheep erythrocytes when coated with specific antibodies. The bactericidal activity of the serum against Staphylococcus aureus and Escherichia coli was used to evaluate the alternative complement pathway. Sera were obtained from neonates (40 +/- 2 weeks of gestation), and one-month or three-month old infants, fed either breast or formula. Control serum was obtained from healthy adults between 22 and 30 years of age. The hemolytic capacity of serum from breast-fed infants of one month and three months of age was significantly greater than that of the serum from infants which had been fed formula milk.

Breast Feeding↗