Longitudinal changes in inflammatory markers in nasal lavage of cotton workers. Relation to endotoxin exposure and lung function changes.

OBJECTIVES: The aim of this study was to evaluate time-related changes in inflammatory markers in nasal lavage (NAL) in relation to endotoxin exposure and lung function changes. METHODS: Endotoxin in cotton dust is well known to elicit proinflammatory mediators involved in acute or chronic respiratory inflammation due to cotton dust. We applied nasal lavage as well as lung function and exposure measurements in a small group (n = 11) of cotton workers during 6 weeks of observation (after 2 weeks free of exposure). Several inflammatory markers in NAL, such as interleukin 8 (IL-8), IL-6, and down-stream mediators, including soluble tumor necrosis factor receptor 75 (sTNF-R75) and soluble intercellular adhesion molecule 1 (ICAM-1), cell counts, marker of epithelial response (uric acid), and marker of plasma exudation (albumin) were measured. RESULTS: At the exposure levels examined in this study [cotton dust, geometric mean (GM) = 1.10 mg/m3; endotoxin, GM = 2,869 EU/m3], several inflammatory markers in NAL such as IL-8, sTNF-R75, and albumin tended to increase through the measurement period with increasing airborne endotoxin concentration (in six workers who had paired measurements in weeks 1 and 6). Although no statistical significance was reached, airborne endotoxin exposure and all inflammatory markers in NAL were relatively higher in cotton workers with a 6-week lung function decrease. CONCLUSION: The data suggest that inflammatory markers in NAL are associated with repeated airborne endotoxin exposure.

Adult↗

Measurement of beta(1-->3)-glucans in occupational and home environments with an inhibition enzyme immunoassay.

beta (1-->3)-Glucans are known for their potent ability to induce nonspecific inflammatory reactions and are believed to play a role in bioaerosol-induced respiratory symptoms. An inhibition enzyme immunoassay (EIA) was developed for the quantitation of beta (1-->3)-glucans in dust samples from occupational and residential environments. Immunospecific rabbit antibodies were produced by immunization with bovine serum albumin-conjugated laminarin [beta (1-->3)-glucan] and affinity chromatography on epoxy-Sepharose-coupled beta (1-->3)-glucans. The laminarin-based calibration curve in the inhibition EIA ranged from approximately 40 to 3,000 ng/ml (15 to 85% inhibition). Another beta (1-->3)-glucan (curdlan) showed a similar inhibition curve but was three to five times less reactive on a weight basis. Pustulan, presumed to be a beta (1-->6)-glucan, showed a parallel dose-response curve at concentrations 10 times higher than that of laminarin. Control experiments with NaIO4 and beta (1-->3)-glucanase treatment to destroy beta (1-->6)- and beta (1-->3)-glucan structures, respectively, indicate that the immunoreactivity of pustulan in the assay was due to beta (1-->3)-glucan and not to beta (1-->6)-glucan structures. Other polysaccharides, such as mannan and alpha (1-->6)-glucan, did not react in the inhibition EIA. Beta (1-->3)-Glucan extraction of dust samples in water (with mild detergent) was performed by heat treatment (120 degrees C) because aqueous extracts obtained at room temperature did not contain detectable beta (1-->3)-glucan levels. The assay was shown to detect heat-extractable beta (1-->3)-glucan in dust samples collected in a variety of occupational and environmental settings. On the basis of duplicate analyses of dust samples, a coefficient of variation of approximately 25% was calculated. It was concluded that the new inhibition EIA offers a useful method for indoor beta (1-->3)-glucan exposure assessment.

Animals↗

Enzyme immunoassays for total and allergen specific IgE in population studies.

OBJECTIVE: Extensive IgE serology in occupational or environmental health studies is often hampered by a lack of technical facilities and finance. The use in population studies of relatively simple and inexpensive enzyme immunoassays (EIAs) was therefore evaluated for the assessment of total serum immunoglobulin E (IgE), and of specific IgE reactions with various common (house dust mites, grass and birch pollen, and cat) or occupational (fungal alpha-amylase and rat urinary protein) allergens. METHODS: Total IgE was measured with a sandwich EIA, calibrated with commercially available IgE standards. Reproducibility was studied by testing pooled normal human serum samples in each of a large series of test plates. A panel of 156 children's serum samples with known IgE values was used to compare the assay with other total IgE assays. A previously developed EIA for anti-yeast IgE was adapted for the measurement of IgE reacting with various common and occupational allergens. Binding of IgE to microwells coated with commercially available allergen extracts, or allergen preparations from our own laboratory, was measured with a monoclonal anti-human IgE antibody and subsequent incubations with biotinylated rabbit anti-mouse Ig and avidin-peroxidase. Panels of serum samples from school children (n = 116), bakery workers (n = 126), and laboratory animal workers (n = 52) were used to study sensitivity and specificity, with reference to skin prick tests as the standard, and to compare the EIAs with commercially available test kits. RESULTS: The detection limit of the EIA for total IgE was 0.5-1 kU/l for undiluted serum samples, and the coefficient of variation between assays was less than 15% at serum concentrations between 1 and 150 kU/l. Results obtained with the panel of 156 children's serum samples were strongly correlated (r2 = 0.86) with IgE concentrations measured previously by radioimmunoassay. The results of the EIA for various occupational allergens correlated very well, both qualitatively and quantitatively, with the results of commercial test kits. Sensitivity and specificity of the EIA results as a predictor of skin prick test reactivity towards common allergens (house dust mite, grass pollen, birch pollen, and cat) were remarkably high (> 80%-90%) in the series of 116 children's serum samples. In a population of bakery workers the specificity of the EIAs was also very high (> 90%). The sensitivity was notably lower (30%-70%) in this adult population, which is, however, in agreement with results reported for conventional IgE tests. CONCLUSION: As the costs were estimated to be at least five to 10-fold lower than those of commercial test kits, the EIAs for total and specific IgE may be very useful tools in epidemiological studies of atopic respiratory or other disorders.

Adult↗

Influence of various dust sampling and extraction methods on the measurement of airborne endotoxin.

The influence of various filter types and extraction conditions on the quantitation of airborne endotoxin with the Limulus amebocyte lysate test was studied by using airborne dusts sampled in a potato processing plant. Samples were collected with an apparatus designed to provide parallel samples. Data from the parallel-sampling experiment were statistically evaluated by using analysis of variance. In addition, the influence of storage conditions on the detectable endotoxin concentration was investigated by using commercially available lipopolysaccharides (LPS) and endotoxin-containing house dust extracts. The endotoxin extraction efficiency of 0.05% Tween 20 in pyrogen-free water was seven times higher than that of pyrogen-free water only. Two-times-greater amounts of endotoxin were extracted from glass fiber, Teflon, and polycarbonate filters than from cellulose ester filters. The temperature and shaking intensity during extraction were not related to the extraction efficiency. Repeated freeze (-20 degrees C)-and-thaw cycles with commercial LPS reconstituted in pyrogen-free water had a dramatic effect on the detectable endotoxin level. A 25% loss in endotoxin activity per freeze-thaw cycle was observed. Storage of LPS samples for a period of 1 year at 7 degrees C had no effect on the endotoxin level. House dust extracts showed a decrease of about 20% in the endotoxin level after they had been frozen and thawed for a second time. The use of different container materials (borosilicate glass, "soft" glass, and polypropylene) did not result in different endotoxin levels. This study indicates that the assessment of endotoxin exposure may differ considerably between groups when different sampling, extraction, and storage procedures are employed.

Air Pollutants↗

Inhibition and enhancement in the analysis of airborne endotoxin levels in various occupational environments.

Inhibition and enhancement effects on the Limulus Amebocyte Lysate (LAL) assay were studied in a series of endotoxin exposure samples from various occupational environments. Two types of analyses were performed, with various dilutions and with spiked samples. Results showed that inhibition and enhancement occurred in some samples, leading to respective underestimation and overestimation of the endotoxin concentration. When inhibition or enhancement is present, the result of this study shows that large differences in endotoxin concentration may be found, depending on the dilution at which the sample is analyzed. False conclusions about exposure levels and their potential health effects might be introduced. Results show that quality control procedures need to become standard practice when endotoxins are analyzed in occupational environments and development of a validated, generally accepted protocol should be encouraged.

Air Pollutants↗

Effect of exercise training and diet modification on serum lipids and lipoproteins in coronary artery disease patients treated with thiazides.

The effects of chronic exercise training and diet modification on serum lipids and lipoproteins were measured in 17 hypertensive males and 41 normotensive males with documented coronary artery disease (CAD). Exercise consisted of aerobic activities which were performed at approximately 75-85% of the symptom-limited maximum heart rate for 30-40 minutes, three times weekly for 3 months. Each participant's diet was also controlled, the recommended daily intake of fat and cholesterol was no more than 40 g/day and 200 mg/day, respectively. Significant increases in estimated VO2max and total cholesterol/high density lipoprotein (HDL) and a significant decrease in serum triglycerides were documented after training. Significant differences in serum cholesterol and triglycerides between the nondiuretic and diuretic patients were also noted. No significant changes were found in low density lipoprotein (LDL), HDL, or body weight. Vigorous aerobic training and diet modification can favorably modify the deleterious effects of diuretic medications on serum triglycerides and total cholesterol/HDL in patients with documented CAD.

Adult↗