Search PubMed⌕ Search

Biomedical subjects

J D Thomas

Publications and source records attributed to J D Thomas.

At least 199 records · Page 11Linked to original sources

Blunt traumatic rupture of a mitral papillary muscle head.

Severe mitral regurgitation developed in a patient after a lateral-impact motor vehicle accident. The papillary muscle head was disrupted without evidence of other myocardial injury. We hypothesize that a dramatic and sudden increase in intrathoracic pressure may have produced the injury. The patient experienced progressive heart failure and underwent successful mitral valve repair 9 days after the accident.

Accidents, Traffic↗

Prognostic value of dobutamine echocardiography in patients with left ventricular dysfunction.

OBJECTIVES: This study sought to establish the prognostic implications of ischemic and viable myocardium identified by dobutamine echocardiography in patients with left ventricular dysfunction. BACKGROUND: Recent studies have suggested that in patients with viable myocardium identified by positron emission tomography, medical treatment is associated with recurrent cardiac events. Dobutamine echocardiography has been used to identify viable myocardium in patients with left ventricular dysfunction, but the prognostic significance of this test is undefined. METHODS: One hundred thirty-six consecutive patients (mean [+/- SD] age 67 +/- 7.9 years; 104 men) with moderate or severe left ventricular dysfunction (left ventricular ejection fraction 30 +/- 5%) undergoing dobutamine echocardiography were included in the study. Dobutamine was administered using a standard incremental protocol (5 to 40 micrograms/kg body weight per min intravenously in 3-min stages) with additional atropine (1 mg intravenously) as required. Standard body weight echocardiographic views were digitized on-line and compared using a side-by-side display. Viable myocardium was identified by enhancement of regional function at low dose (< 10 micrograms); scar was diagnosed by akinesia at rest or dyskinesia without change and ischemia as new or worsening dysfunction. One hundred thirty patients (95%) were followed up for 16 +/- 8 months after the original study for major cardiac events (cardiac death, myocardial infarction or severe unstable angina requiring late myocardial revascularization). RESULTS: No significant complications occurred during dobutamine echocardiography. Viable myocardium was detected in 26 patients (19%), ischemia in 23 (17%), both viability and ischemia in 13 (10%) and scar in 74 (54%). Of 108 patients treated medically, 46 had viable or ischemic myocardium, and 62 had scar only. There were no significant differences in age or other clinical characteristics, stress response, left ventricular dimensions and ejection fraction between the two groups. Cardiac events occurred in 26 medically treated patients (24%): 18 died of cardiac-related causes; 4 had a nonfatal myocardial infarction; and 4 had late revascularization because of unstable angina. The event rate was greater in patients with viable or ischemic myocardium than those with scar (43% vs. 8%, p = 0.01 by log-rank test). In a Cox regression model, the presence of viable or ischemic myocardium was found to predict subsequent events (relative risk 3.51, p = 0.02) independently of ejection fraction and age. CONCLUSIONS: Viable or ischemic myocardium detected at dobutamine echocardiography in patients with left ventricular dysfunction is associated with an adverse prognosis, independent of age and ejection fraction.

Aged↗

Mechanisms of hemolysis with mitral prosthetic regurgitation. Study using transesophageal echocardiography and fluid dynamic simulation.

OBJECTIVES: The aims of this study were to define the hydrodynamic mechanisms involved in the occurrence of hemolysis in prosthetic mitral valve regurgitation and to reproduce them in a numeric simulation model in order to estimate peak shear stress. BACKGROUND: Although in vitro studies have demonstrated that shear stresses > 3,000 dynes/cm2 are associated with significant erythrocyte destruction, it is not known whether these values can occur in vivo in conditions of abnormal prosthetic regurgitant flow. METHODS: We studied 27 patients undergoing reoperation for significant mitral prosthetic regurgitation, 16 with and 11 without hemolysis. We classified the origin and geometry of the regurgitant jets by using transesophageal echocardiography. By using the physical and morphologic characteristics defined, several hydrodynamic patterns were simulated numerically to determine shear rates. RESULTS: Eight (50%) of the 16 patients with hemolysis had paravalvular leaks and the other 8 had a jet with central origin, in contrast to 2 (18%) and 9 (82%), respectively, of the 11 patients without hemolysis (p = 0.12, power 0.38). Patients with hemolysis had patterns of flow fragmentation (n = 2), collision (n = 11) or rapid acceleration (n = 3), whereas those without hemolysis had either free jets (n = 7) or slow deceleration (n = 4) (p < 0.001, power 0.99). Numeric simulation demonstrated peak shear rates of 6,000, 4,500, 4,500, 925 and 950 dynes/cm2 in these five models, respectively. CONCLUSIONS: The distinct patterns of regurgitant flow seen in these patients with mitral prosthetic hemolysis were associated with rapid acceleration and deceleration or high peak shear rates, or both. The nature of the flow disturbance produced by the prosthetic regurgitant lesion and the resultant increase in shear stress are more important than the site of origin of the flow disturbance in producing clinical hemolysis.

Aged↗

Differentiation of constrictive pericarditis from restrictive cardiomyopathy: assessment of left ventricular diastolic velocities in longitudinal axis by Doppler tissue imaging.

OBJECTIVES: We sought to determine the utility of left ventricular expansion velocities in differentiating constrictive pericarditis from restrictive cardiomyopathy. BACKGROUND: Several studies have shown that left ventricular diastolic expansion is influenced by the elastic recoil forces of the myocardium. These forces are affected by intrinsic myocardial disease but should be preserved when diastole is impaired as a result of extrinsic causes. METHODS: Using Doppler tissue imaging, we measured peak early velocity of longitudinal axis expansion (Ea) in 8 patients with constrictive pericarditis, 7 patients with restriction and 15 normal volunteers. Transmitral early (E) and late (A) Doppler flow velocities, left ventricular systolic and diastolic volumes, ejection fraction and mitral annular M-mode displacement were also compared between the groups. RESULTS: The Ea value was significantly higher in normal subjects (14.5 +/- 4.7 cm/s [mean +/- SD]) and in patients with constriction (14.8 +/- 4.8 cm/s) than in those with restriction (5.1 +/- 1.4 cm/s, p < 0.001 constriction vs. restriction). There was weak correlation between Ea and the extent of annular displacement (r = 0.55, p = 0.004) and the E/A ratio (r = 0.44, p = 0.03). There was no correlation between Ea and E (r = 0.33, p = 0.07) or ejection fraction (r = 0.21, p = 0.26). By multivariate analysis, Ea was the best variable for differentiating constriction from restriction. CONCLUSIONS: Our study indicates that longitudinal axis expansion velocities are markedly reduced in patients with restrictive cardiomyopathy. The poor correlation found with transvalvular flow velocities suggests that Ea may be relatively preload independent. The measurement of longitudinal axis expansion velocities provides a clinically useful distinction between constrictive pericarditis and restrictive cardiomyopathy and may prove to be valuable in the study of diastolic function.

Adult↗

A practical guide to assessment of ventricular diastolic function using Doppler echocardiography.

Doppler assessment of diastolic function has become a standard part of routine echocardiographic examination and imparts information relevant to a patient's functional class, management and prognosis. This review describes the Doppler patterns of diastolic function relative to physical signs and physiology. A continuum of doppler patterns of diastolic function exists, including normal diastolic function, impaired relaxation, pseudonormal filling, restriction, constriction and tamponade. These patterns evolve from one to another in a single individual, with changes in disease evolution, treatment and loading conditions. New applications of continuous wave Doppler, color Doppler M-mode and Doppler tissue imaging are refining our understanding of diastolic function.

Diastole↗

Integrated backscatter for quantification of left atrial spontaneous echo contrast.

OBJECTIVES: This study was designed to develop a quantitative method of spontaneous echo contrast (SEC) assessment using integrated backscatter and to compare integrated backscatter SEC measurement with independent qualitative grades of SEC and clinical and echocardiographic predictors of thromboembolism. BACKGROUND: Left atrial SEC refers to dynamic swirling smokelike echoes that are associated with low flow states and embolic events and have been graded qualitatively as mild or severe. METHODS: We performed transesophageal echocardiography in 43 patients and acquired digital integrated backscatter image sequences of the interatrial septum to internally calibrate the left ventricular cavity and left atrial cavity under different gain settings. Patients were independently assessed as having no, mild or severe SEC. We compared intensity of integrated backscatter in the left atrial cavity relative to that in the left ventricular as well as to the independently assessed qualitative grades of SEC. Fourier analysis characterized the temporal variability of SEC. The integrated backscatter was compared with clinical and echocardiographic predictors of thromboembolism. RESULTS: The left atrial cavity integrated backscatter intensity of the mild SEC subgroup was 4.7 dB higher than that from the left ventricular cavity, and the left atrial intensity of the severe SEC subgroup was 12.5 dB higher than that from the left ventricular cavity. The left atrial cavity integrated backscatter intensity correlated well with the qualitative grade. Fourier transforms of SEC integrated backscatter sequences revealed a characteristic dominant low frequency/high amplitude spectrum, distinctive from no SEC. There was a close relationship between integrated backscatter values and atrial fibrillation, left atrial size, left atrial appendage flow velocities and thrombus. CONCLUSIONS: Integrated backscatter provides an objective quantitative measure of SEC that correlates well with qualitative grade and is closely associated with clinical and echocardiographic predictors of thromboembolism. The relationship between integrated backscatter measures and cardioembolic risk will be defined in future multicenter studies.

Aged↗

Assessment of mitral annular dynamics during diastole by Doppler tissue imaging: comparison with mitral Doppler inflow in subjects without heart disease and in patients with left ventricular hypertrophy.

The purpose of this study was to determine the normal pattern and magnitude of mitral annular velocities in diastole by Doppler tissue imaging (DTI) and to assess whether this is altered in patients with left ventricular hypertrophy. Mitral annulus velocities were measured by DTI. Peak and time-velocity integral were measured from the DTI tracings and the timing of the velocities in relation to electrocardiogram. DTI was compared with M-mode echo of the annulus and mitral inflow Doppler velocities. Integrated annular velocities by DTI correlated with the annular displacement. Early diastolic velocities decreased with age and in patients with left ventricular hypertrophy. In the hypertrophy group, early diastolic velocities were significantly lower than normal even after correcting for age. Patients with left ventricular hypertrophy also showed a delay in peak early diastolic mitral annular velocity (5.5 +/- 21 msec after the E wave). In conclusion, mitral annular velocity in diastole is readily recorded by DTI. The magnitude and the pattern of these velocities are significantly altered by age and by left ventricular hypertrophy. This method provides a new insight into diastolic filling events and may prove useful in detecting abnormal diastolic function.

Adult↗

Myocardial wall velocity assessment by pulsed Doppler tissue imaging: characteristic findings in normal subjects.

To validate the use of pulsed Doppler tissue imaging that measures myocardial wall velocities and to define the characteristics of these velocities in normal subjects, we obtained and compared the anteroseptal and posterior wall velocities in 24 volunteers with pulsed Doppler tissue imaging and digitized M-mode echocardiography. We also studied the relation between velocity components and hemodynamic events timed by standard Doppler flows. There was an excellent correlation between Doppler and M-mode-derived velocities (r = 0.95, p < 0.001), with higher reproducibility for Doppler (r = 0.99) than for M-mode (r = 0.95, p < 0.001). Biphasic velocities that were uniformly present during isovolumic contraction and relaxation were attributed to geometric changes due to asynchronous contraction and ventricular interdependence. We conclude that wall velocities obtained by pulsed Doppler tissue imaging are accurate and reproducible. This method may prove useful for studying the contractile and elastic properties of the myocardium.

Adolescent↗

Value of proximal regurgitant jet size in tricuspid regurgitation.

Recent studies have shown good agreement between proximal regurgitant jet size obtained with transthoracic color flow mapping and regurgitant fraction in patients with mitral regurgitation. To evaluate this in patients with tricuspid regurgitation, we analyzed 40 patients in sinus rhythm, 16 with free jets and 24 with impinging jets, comparing proximal jet size (millimeters) with parameters derived from the Doppler two-dimensional echocardiographic method (regurgitant fraction) and the flow-convergence method (peak flow rate, effective regurgitant orifice area, and momentum). Good agreement was noted between peak flow rate (r = 0.80, p < 0.001), momentum (r = 0.80, p < 0.001), and effective regurgitant orifice area (r = 0.78, p < 0.001), with proximal jet size measured in the apical four-chamber view in patients with free jets. The average of jet proximal size in three planes also had good correlation with peak flow rate (r = 0.75, p < 0.001), regurgitant fraction, momentum, and effective regurgitant orifice area (r = 0.74, p < 0.001). In patients with impinging jets, agreement was fair between effective regurgitant orifice (r = 0.65, p < 0.001), peak flow rate (0.65, p < 0.001), and momentum (r = 0.62, p < 0.001) with mean jet proximal size. Jet proximal size obtained with transthoracic color flow mapping is a good semiquantitative tool for measuring tricuspid regurgitation in free jets that correlates well with established measures of the severity and with new parameters available from analysis of the proximal acceleration field. In patients with eccentrically directed wall jets, the correlation weakens but still appears clinically significant.

Adult↗

Diagnosis of patent foramen ovale by contrast versus color Doppler by transesophageal echocardiography: relation to atrial size.

To ascertain the factors related to the transesophageal echocardiographic diagnosis of patent foramen ovale, the primary echocardiographic data were reviewed from 74 patients with that diagnosis. Similar detection rates were observed with contrast echocardiography (82%) and color flow mapping (78%), but contrast was more sensitive in patients with normal-sized atria (94%) and isolated right atrial enlargement (100%) than in those with enlarged left atria, all but three of whom had biatrial enlargement (52%) (p < 0.001 by chi-square test). Doppler flow mapping was less sensitive for normal-sized atria (66%) than for isolated enlarged right atria (81%) and left (bi-) atrial enlargement (96%) (p = 0.024). Patent foramen ovale was directly visualized by two-dimensional echocardiography in 80%, with close agreement to the size of the color flow jet (r = 0.90, delta = 0.1 +/- 0.4 mm); foramen ovale size was related to right atrial area (r = 0.31, p = 0.015). Thus both saline contrast and color flow imaging are necessary to exclude the diagnosis of patent foramen ovale.

Case-Control Studies↗

New insights into the reduction of mitral valve systolic anterior motion after ventricular septal myectomy in hypertrophic obstructive cardiomyopathy.

To determine the mechanism of reduction of mitral valve systolic anterior motion by myectomy, we examined 33 patients with hypertrophic obstructive cardiomyopathy echocardiographically before and after myectomy. Measurements included outflow tract diameter, the direction of ejection streamline (the angle between the ejection flow and the mitral valve), midventricular fractional area change, and papillary muscle inward excursion in the short-axis image. After myectomy, the outflow tract was enlarged (from 1.2 +/- 0.3 cm to 2.1 +/- 0.4 cm; p < 0.001), and the ejection flow became more parallel to mitral leaflets (from 51 +/- 10 degrees to 28 +/- 8 degrees; p < 0.001), whereas hyperdynamic midventricular fractional area change was reduced (81% +/- 14% to 62% +/- 14%; p < 0.001), and papillary muscle excursion decreased (1.3 +/- 0.3 cm to 0.8 +/- 0.3 cm; p < 0.001). Outflow enlargement and reduced ventricular contraction would decrease the Venturi force. Change of ejection streamline and reduced contraction would decrease the drag force onto the mitral leaflets. Blunted papillary motion would increase the mitral leaflet tension and decrease the effect of drag force on both leaflets. Thus myectomy decreases Venturi and drag forces and appears to reduce systolic anterior motion of the mitral valve.

Cardiomyopathy, Hypertrophic↗

Characterization of left atrial appendage Doppler flow in atrial fibrillation and flutter by Fourier analysis.

The aim of this study was to characterize left atrial appendage mechanical function in atrial fibrillation and flutter by Fourier analysis to analyze frequency and regularity of flow. Left atrial appendage function is central to a patient's risk for thromboembolism. Although the function of the appendage can be analyzed by Doppler echocardiography in sinus rhythm, its mechanical function in atrial fibrillation and flutter has not been well characterized. This lack of adequate definition is caused by the complexity and temporal variability of the Doppler flow profiles. We assessed left atrial appendage function in 21 cases of atrial fibrillation (n - 11) and flutter (n = 10) and five in sinus rhythm with transesophageal Doppler echocardiography. Doppler profiles were examined by Fourier analysis, and the power spectra compared and analyzed between patients with atrial fibrillation and flutter. Left atrial appendage Doppler flow in atrial fibrillation produced Fourier spectra over a narrow band of frequencies with a peak frequency of 6.2 +/- 1.0 Hz, significantly higher than in atrial flutter (3.9 +/- 0.6 Hz, p < 0.00001). Additionally, a significant difference in subharmonic modulation (spectral power below the peak frequency) was observed between atrial appendage flow in atrial fibrillation and flutter, because 37% +/- 16% of the total spectral power was achieved before the dominant frequency in atrial fibrillation compared with 20% +/- 14% in atrial flutter (p = 0.02). Conversely, patients in sinus rhythm exhibited broad-banded Fourier spectra with most of the power in discrete frequency spikes at harmonics above the fundamental frequency with very little subharmonic modulation (1% +/- 0.05%). Left atrial appendage function in atrial fibrillation and flutter can be well characterized by Fourier analysis of Doppler flow. Atrial fibrillation has higher dominant frequencies and greater subharmonic modulation compared with flutter. Moreover, atrial fibrillation demonstrated quasiperiodic contraction patterns typically found in chaotic systems. Fourier analysis of left atrial appendage contraction patterns may therefore have significant promise in providing insights into mechanisms of atrial fibrillation and thromboembolism.

Aged↗

Prospects for telediagnosis using ultrasound.

Ultrasound imaging is currently used as a primary diagnostic tool in cardiology, abdominal disorders, pulmonary medicine, trauma, and obstetrics. Because of its relatively low capital and operating costs as well as its growth potential, it represents one of the major diagnostic modalities of future health care. However, the use of ultrasonography as a mobile and powerful modality is controlled by the availability of a highly skilled technician to acquire the images and an experienced physician to interpret them. This paper discusses the technology required to increase the availability of a diagnosing physician by employing telerobotics. With this technology, the physician can guide the motion of the transducer by the technician from a remote location. Thus, the physician controls the examination and renders the diagnosis. It is shown that communication lines at 1.5 Mbits/s (T-1 speed) can, with appropriate compression, support both real-time viewing of the ultrasound images and telerobotic manipulation of the transducer. The incremental costs of telediagnosis for an examination are estimated to be a small fraction of the base charges and significantly less than the expense of bringing a physician to a remote location or transporting a patient to a regional medical center. Telediagnosis can, in addition, provide benefits from immediate interpretation and consultation that cannot be duplicated using store-and-forward scenarios.

Costs and Cost Analysis↗

Instantaneous diastolic transmitral pressure differences from color Doppler M mode echocardiography.

Pulsed and continuous wave Doppler velocity measurements are routinely used in clinical practice to assess severity of stenotic and regurgitant valves or to estimate intracavitary pressures. However, this method only evaluates the convective component of the pressure gradient (based on the velocity measurements) and neglects the contribution of inertial forces that can be important, in particular for flow across nonstenotic valves. Digital processing of color Doppler ultrasound data was used to noninvasively estimate both the convective and inertial components of the transmitral pressure difference. Simultaneous pressure and velocity measurements were obtained in six anesthetized open-chest dogs. The instantaneous diastolic transmitral pressure difference is computed from the M mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation. The inclusion of the inertial forces ([delta PI]max = 0.90 +/- 0.30 mmHg) in the noninvasive pressure difference calculation significantly increased the correlation with catheter-based measurement (r = 0.15 +/- 0.23 vs. 0.85 +/- 0.08; P < 0.0001) and also allowed an accurate approximation of the peak early filling pressure difference ([delta PC+I]max = 0.95[delta Pcath]max + 0.07, r = 0.92, P < 0.001, error: epsilon C+I ([delta PC+I]max-[delta Pcath]max) = 0.01 +/- 0.24 mmHg, N = 90]. Noninvasive estimation of left ventricular filling pressure differences using this technique will improve the understanding of diastolic filling and function of the heart.

Animals↗

Chronotropic response to exercise predicts angiographic severity in patients with suspected or stable coronary artery disease.

Inappropriate chronotropic response to exercise has been observed to correlate with poor prognosis in patients with coronary disease, but the mechanism for this association is not well defined. We attempted to examine the association between chronotropic response to exercise and angiographic severity of coronary disease in patients with suspected or stable coronary artery disease. The chronotropic response, expressed as peak heart rate, chronotropic index (ratio of heart rate reserve and metabolic reserve utilized), or percent maximal heart rate achieved, was correlated with angiographic findings obtained within 180 days of the test. Significant coronary disease was defined as > or = 1 stenosis of > or = 50% in a major epicardial artery or its main branches; severe coronary disease was defined as > or = 50% stenosis in all 3 epicardial arteries, or in the left main coronary trunk, or 2-vessel disease with > or = 70% proximal left anterior descending artery stenosis. We observed that peak heart rate and percent maximal heart rate achieved were independent negative predictors of both significant and severe coronary disease by logistic regression. The chronotropic index predicted severe coronary disease only. All 3 parameters of chronotropic response exhibited a significant gradient of abnormality across the spectrum of coronary disease (p < 0.01 for all), expressed by the number of vessels involved and correlated with left anterior descending artery involvement (p < 0.05 for all). We conclude that chronotropic response to exercise predicts the presence and angiographic severity of coronary disease. This association is likely related to the proportion of left ventricular myocardium rendered ischemic during stress.

Aged↗

Pressure recovery in bileaflet heart valve prostheses. Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position.

BACKGROUND: We investigate pressure recovery in central and side orifices of St Jude valves and the effect of mitral versus aortic position on the relation between Doppler- and catheter-derived pressure gradients. METHODS AND RESULTS: Maximum, transvalvular, and net pressure gradients are calculated and compared with Doppler-derived gradients in an in vitro model. Pressure recovery and pressure loss coefficients are calculated. Simultaneous Doppler and catheter gradients are obtained intraoperatively in five patients undergoing mitral valve replacement. Centerline Doppler gradients correspond closely with maximum catheter gradients but are higher than transvalvular and net pressure gradients. Thirty-six percent of the initial pressure drop is recovered between the valve leaflets and is independent of valve size or configuration. A variable amount of postvalvular pressure recovery is observed depending on aortic or mitral configuration. Side orifice velocities are 85 +/- 4% of the centerline velocities. Incorporation of the pressure loss coefficient in the simplified Bernoulli equation shows close agreement between centerline Doppler gradients and transvalvular gradients (r = .99, y = 1.11x-0.19). CONCLUSIONS: Gradients across the St Jude valve measured by Doppler ultrasound are higher than transvalvular or net catheter gradients due to downstream pressure recovery. This is more marked for Doppler gradients based on centerline velocities than side orifice velocities and is more pronounced for valves in an aortic than a mitral configuration. Therefore, to be comparable with invasive transvalvular catheter gradients, either Doppler gradients should be calculated based on side orifice velocity measurements or the Doppler gradient calculation should include the pressure loss coefficient when based on central orifice velocities.

Aortic Valve↗