Search PubMed⌕ Search

Biomedical subjects

J D Spengler

Publications and source records attributed to J D Spengler.

At least 73 records · Page 4Linked to original sources

Personal and indoor/outdoor nitrogen dioxide exposure assessments of 23 homes in Taiwan.

Indoor and outdoor nitrogen dioxide (NO2) concentrations of 23 homes from two areas in Taiwan, the city of Taipei and a rural village in central Taiwan, were measured concurrently from December 1987 to January 1988. NO2 measurements were carried out by Palmes tube for one week and filter badges for two days. In Taipei, the mean NO2 concentrations outdoors, in the kitchens, in the livingrooms, and in the bedrooms were 40.1 ppb, 34.4 ppb, 32.1 ppb, and 29.7 ppb for one week, and were 25.7 ppb, 25.6 ppb, 22.6 ppb, and 20.5 ppb for two days. In the village of central Taiwan, the corresponding concentrations were 23.5 ppb, 24.5 ppb, 20.4 ppb, and 17.5 ppb for one week, and 20.3 ppb, 24.7 ppb, 18.8 ppb, and 15.4 ppb for two days. The NO2 concentrations of all microenvironments in Taipei were significantly higher than those in the village of central Taiwan. The outdoor NO2 concentrations were significantly higher than the indoor NO2 concentrations in Taipei. The NO2 measurements in the kitchens were higher than all other measurements indoors and outdoors in the village of central Taiwan. The houses which used natural gas as cooking fuel had slightly higher indoor NO2 concentrations than the houses which used LPG as cooking fuel in Taipei city. Cement houses had slightly higher indoor NO2 concentrations than brick houses. The mean of housewives' exposures was 30.8 ppb in Taipei and 19.9 ppb in the village of central Taiwan. The explanation power of the housewife's exposure to NO2 was 72% by the time weighted-average model and 70% by the simple linear regression model.

Air Pollutants↗

Shelter for the twenty-first century.

Housing for the twenty-first century will be shaped by the changes that are occurring in society. These include the demographics of the occupant, the products and materials used for construction and furnishing, and the basic use of the structure. An aging population will have different demands on design and function. The health concerns of an aging population encompass chronic degenerative diseases as well as injury. The lessons of the past must make us mindful that chronic, low-level exposures to substances can occur at home. Products and materials used in homes can release vapors that may affect immunologic and neurologic function. Manifestations of dysfunctions will be more important as our population ages and if there is a continued reliance on new chemical formulation for products used in homes and workplaces. The future portends changes in functional use of residences. Electronic communications and robotics will decentralize our work force. Manufacturing or office functions will occur at home. This will present new challenges for health and safety for both monitoring and prevention.

Environmental Health↗

A personal monitoring study to assess workplace exposure to environmental tobacco smoke.

We enrolled 15 nonsmoking volunteers to evaluate the feasibility of measuring personal exposure to environmental tobacco smoke (ETS) at work and to characterize workplace exposures. During one workshift, we obtained questionnaires on exposure, saliva and urine for cotinine, and personal air samples for respirable particles and nicotine. The levels of cotinine, respirable particles, and nicotine varied widely with self-reports of exposure to ETS, but on average increased with increasing exposure.

Adult↗

Indoor/outdoor measurements of volatile organic compounds in the Kanawha Valley of West Virginia.

The Kanawha Valley region of West Virginia which is comprised of Charleston and surrounding communities is the center of a heavily industrialized area known for its chemical manufacturing. As part of a larger study designed to investigate the impact of the chemical industry on human exposures to volatile organic compounds (VOC), a study of the relationship between indoor and outdoor concentrations was conducted. Thirty-five homes were selected for monitoring from among volunteers; approximately ten in each of three distinct population-industry centers and four outside the Valley to act as controls. Monitoring was performed using passive, badge samplers with a three-week monitoring period. Two separate questionnaires were administered: one for characterization of the residence; and one to characterize source use during monitoring. Participants were also asked to keep a record of their activities with respect to in-home, outdoors and other indoor environments. Analysis of the samplers was performed by solvent extraction followed by gas chromatography using a flame-ionization detector. Results suggest that indoor VOC concentrations are higher than outdoor concentrations. Additionally, certain ventilation-related parameters were identified that afforded some predictive power for indoor concentrations. No statistically significant differences between regions were identified.

Air Pollutants, Occupational↗

Particulate and nicotine sampling in public facilities and offices.

The purpose of this study was to characterize and measure indoor air quality in public facilities and office buildings. The pollutants of interest were particulate matter smaller than 2.5 microns in diameter, PM-2.5, and environmental tobacco smoke (ETS). Integrated PM-2.5 samples were taken on Teflon membrane filters using Harvard Aerosol Impactors as a pre-size selector. Filters were analyzed by gravimetric analysis. Nicotine, which was used as a marker for ETS, was collected on sodium-bisulfate-impregnanted, glass-fiber filters and was analyzed by gas chromatography. Twenty-one structures were monitored in Metropolitan Boston. Measured particle concentrations ranged from 6.0 micrograms/m3 to about 550 micrograms/m3. Nicotine concentrations were as high as 26 micrograms/m3 in a designated smoking room. Real-time measurements were also taken using two types of nephelometers; a Handheld Aerosol Monitor (HAM) and a Miniature Real-Time Aerosol Monitor (MINIRAM). Short-term field measurements with these instruments correlated better with the integrated PM-2.5 concentrations in smoking locations than with concentrations in non-smoking areas.

Nicotine↗

Short-term pulmonary function change in association with ozone levels.

As part of the ongoing Harvard Six Cities study of the respiratory effects of air pollution, repeated measurements of pulmonary function (FVC, FEV75, MMEF, and Vmax75) were taken at approximately weekly intervals in a population of 154 school children living in Kingston and Harriman, Tennessee. A series of as many as six measurements were obtained for each child over approximately a 2-month period beginning in February 1981. Concurrent measurements of ambient ozone, and fine particle and fine sulfate concentrations were obtained at a site near the study community. The maximal hourly ozone concentration observed during the study was 78 ppb. Child-specific linear regressions were fit that related short-term pulmonary function changes to air pollution or temperature. We found that decrements in FVC, FEV75, MMEF, and Vmax75 were associated with ozone, but not with particulate levels. Decrements in FVC, MMEF, and Vmax75 were also associated with temperature. Although slopes of pulmonary function on ozone varied across children, in general there was no evidence that this variation represented heterogeneity of response as opposed to random estimation errors. In addition, no evidence was found that individual response to ozone was related to sex, presence of asthma, respiratory illness before 2 yr of age, or the MMEF/FVC ratio, a rough surrogate for airway size. We conclude that ambient exposures to ozone at levels well below the National Ambient Air Quality Standard of 120 ppb are associated with transient decreases in lung function, the long-term significance of which is uncertain.

Air Pollutants↗

Effects of inhalable particles on respiratory health of children.

Results are presented from a second cross-sectional assessment of the association of air pollution with chronic respiratory health of children participating in the Six Cities Study of Air Pollution and Health. Air pollution measurements collected at quality-controlled monitoring stations included total suspended particulates (TSP), particulate matter less than 15 microns (PM15) and 2.5 microns (PM2.5) aerodynamic diameter, fine fraction aerosol sulfate (FSO4), SO2, O3, and No2. Reported rates of chronic cough, bronchitis, and chest illness during the 1980-1981 school year were positively associated with all measures of particulate pollution (TSP, PM15, PM2.5, and FSO4) and positively but less strongly associated with concentrations of two of the gases (SO2 and NO2). Frequency of earache also tended to be associated with particulate concentrations, but no associations were found with asthma, persistent wheeze, hay fever, or nonrespiratory illness. No associations were found between pollutant concentrations and any of the pulmonary function measures considered (FVC, FEV1, FEV0.75, and MMEF). Children with a history of wheeze or asthma had a much higher prevalence of respiratory symptoms, and there was some evidence that the association between air pollutant concentrations and symptom rates was stronger among children with these markers for hyperreactive airways. These data provide further evidence that rates of respiratory illnesses and symptoms are elevated among children living in cities with high particulate pollution. They also suggest that children with hyperreactive airways may be particularly susceptible to other respiratory symptoms when exposed to these pollutants.(ABSTRACT TRUNCATED AT 250 WORDS)

Air Pollutants↗

Home dampness and respiratory morbidity in children.

This study examined the relationship between measures of home dampness and respiratory illness and symptoms in a cohort of 4,625 eight- to 12-yr-old children living in six U.S. cities. Home dampness was characterized from questionnaire reports of mold or mildew inside the home, water damage to the home, and the occurrence of water on the basement floor. Symptoms of respiratory and other illness were collected by questionnaire. Pulmonary function was measured by spirometry. Signs of home dampness were reported in a large proportion of the homes. In five of the six cities, one or more of the dampness indicators were reported in more than 50% of the homes. The association between measures of home dampness and both respiratory symptoms and other non-chest illness was both strong and consistent. Odds ratios for molds varied from 1.27 to 2.12, and for dampness from 1.23 to 2.16 after adjustment for maternal smoking, age, gender, city of residence, and parental education. The relationship between home dampness and pulmonary function was weak, with an estimated mean reduction of 1.0% in FEF25-75 associated with dampness and 1.6% with molds. We conclude that dampness in the home is common in many areas of the United States and that home dampness is a strong predictor of symptoms of respiratory and other illness symptoms among 8- to 12-yr-old children.

Asthma↗

Acute lung function responses to ambient acid aerosol exposures in children.

We examined the relationship between lung function changes and ambient acid aerosol episodes in children attending a residential summer camp. Young females (112) performed daily spirometry, and 96 were assessed on one occasion for airway hyperresponsiveness using a methacholine bronchoprovocation test. Air quality measurements were performed on site and four distinct acid aerosol episodes were observed during the 41-day study. The maximum values observed during the 41-day study were: O3 at 143 ppb; H2SO4 at 47.7 micrograms/m3; and [H+] at 550 nmole/m3. Maximum decrements of 3.5 and 7% for FEV1 and PEF, respectively, were observed to be associated with the air pollution episodes. There was some evidence of a differential lung function response to the episodes where children with a positive response to a methacholine challenge had larger decrements compared to their nonresponsive counterparts.

Acid Rain↗

Exposures to acidic aerosols.

Ambient monitoring of acid aerosols in four U.S. cities and in a rural region of southern Ontario clearly show distinct periods of strong acidity. Measurements made in Kingston, TN, and Steubenville, OH, resulted in 24-hr H+ ion concentrations exceeding 100 nmole/m3 more than 10 times during summer months. Periods of elevated acidic aerosols occur less frequently in winter months. The H+ determined during episodic conditions in southern Ontario indicates that respiratory tract deposition can exceed the effects level reported in clinical studies. Observed 12-hr H+ concentrations exceeded 550 nmole/m3 (approximately 27 micrograms/m3 H2SO4). The maximum estimated 1-hr concentration exceeded 1500 nmole/m3 for H+ ions. At these concentrations, an active child might receive more than 2000 nmole of H+ ion in 12 hr and in excess of 900 nmole during the hour when H2SO4 exceeded 50 micrograms/m3.

Acid Rain↗

Nitrogen dioxide and respiratory infection: pilot investigations.

Laboratory and human studies have raised concern that exposure to nitrogen dioxide may increase the frequency and severity of respiratory infections in children and adults. Cooking with a natural-gas-fueled stove exposes a home's residents to short-term peaks of nitrogen oxides and to higher average levels of nitrogen oxides than are measured in homes with electric stoves. We have designed a longitudinal study of infants to determine if nitrogen dioxide exposure from cooking stoves increases the incidence or severity of respiratory infections during the first 18 months of life. Pilot investigations for the longitudinal study were conducted from 1984 through 1986. This report provides the results of the pilot investigations. The first study, conducted in 1984 and 1985, was designed to document (1) that appropriate subjects could be recruited; (2) that nitrogen dioxide concentrations in Albuquerque homes were in the range of interest; (3) that an infant's personal exposure to nitrogen dioxide could be estimated; and (4) that a valid, feasible approach for surveillance could be implemented. To accomplish these goals, the families of infants were recruited at two Albuquerque hospitals, and their homes were monitored for nitrogen dioxide using a passive sampling tube. With this approach, we successfully recruited 147 households; monitoring for nitrogen dioxide showed substantially higher levels in homes with gas stoves than in homes with electric stoves, as previously found in other U.S. cities. More detailed investigations in a sample of the homes showed that personal exposures of the infants, who did not attend day care, could be satisfactorily estimated by room concentrations. We also demonstrated that mothers would complete a daily calendar-diary on respiratory symptoms and provide information every two weeks on illnesses occurring since the previous surveillance call. The second pilot study, conducted in 1986, was designed to refine the system for illness surveillance. Additional goals were to test further the methods for exposure assessment and to evaluate recruitment of subjects through pediatric practices. We recruited 75 infants and followed them over a four-month period. Information from the surveillance system was compared with the clinical assessments of the project's nurse practitioner and the subjects' physicians, and with the results of viral cultures. We also evaluated biweekly versus weekly surveillance calls. Overall, the results of the second pilot study documented that a surveillance system for respiratory illness that incorporates calendar-diaries and biweekly telephone calls is a feasible, relatively unbiased, and sensitive method for studying respiratory illness in a large population of infants. We also found that subjects could be successfully recruited through a pediatric practice.(ABSTRACT TRUNCATED AT 400 WORDS)

Cohort Studies↗

Respiratory effects of indoor air pollution.

Since the early 1970s, the health effects of indoor air pollution have been investigated with increasing intensity. A large body of literature is now available on diverse aspects of indoor air pollution: sources, concentrations, health effects, engineering, and policy. This article provides a selective summary of this new information with an emphasis on health effects relevant to health care practitioners concerned primarily with immunologically mediated respiratory diseases. We address exposures associated with acute and chronic respiratory effects: tobacco smoke, nitrogen dioxide, wood smoke, and formaldehyde. The article also describes the diverse health problems experienced by workers in newer sealed office buildings. The importance of indoor concentrations in determining personal exposures to pollutants is emphasized.

Air Pollution↗