Search PubMed⌕ Search

Biomedical subjects

J D Hazle

Publications and source records attributed to J D Hazle.

33 records · Page 2Linked to original sources

Correction of ischaemic brain acidosis with SQ29,548/1-benzylimidazole.

Thromboxane A2 (TXA2) is a proaggregatory vasoconstrictor that is synthesized and released during reperfusion of ischaemic brain. We administered a TXA2 receptor antagonist, SQ29,548, and a thromboxane A synthase inhibitor, 1-benzylimidazole (1-BI), to rats subjected to 30 min of reversible forebrain ischaemia. Cerebral thromboxane B2 (TXB2), the stable metabolite of TXA2, measured after 60 min of reperfusion was 0.37 +/- 0.08 ng/mg brain protein in animals treated with SQ29,548/1-BI compared with 1.20 +/- 0.16 in ischaemic controls (p < 0.05). Cerebral pH determined by 31P magnetic resonance spectroscopy was higher in treated animals, 7.06 +/- 0.04, than in ischaemic controls, 6.5 +/- 0.01, after 20 min of reperfusion (p < or = 0.01). The significant elevation of cerebral pH in treated animals persisted at 30 (7.17 +/- 0.05 vs. 6.5 +/- 0.01; p < or = 0.01), 35 (7.17 +/- 0.05 vs. 6.44 +/- 0.04; p < or = 0.01), and 40 min of reperfusion (7.06 +/- 0.06 vs. 6.37 +/- 0.01; p < or = 0.05). We conclude that SQ29,548/1-BI reduces thromboxane levels and promotes resolution of tissue acidosis in ischaemic brain. The combination of a TXA2 receptor antagonist with a thromboxane A synthase inhibitor deserves further study as a potential treatment for acute cerebral infarction.

Acidosis↗

In vivo NMR, biochemical, and histologic evaluation of alcohol-induced fatty liver in rat and a comparison with CCl4 hepatotoxicity.

Magnetic resonance imaging (MRI) and spectroscopy (MRS) were used to follow the time course of ethanol-induced fatty liver in a group of 10 rats fed a diet containing 12% alcohol (ethanol) over a 5-week period. The MR data consisted of T1-weighted images, in vivo 1H spectra, and in vivo T1 relaxation measurements. Changes in short TR images as a result of fatty accumulation were noted only as a slight increase in liver intensity relative to surrounding muscle. A poorly correlated (r = 0.54) increase in water T1 with time was observed. No statistically significant changes in lipid T1 were found. MRS derived lipid content was compared with biochemically derived total lipids and histology. MRS determined liver lipids were found to increase linearly with time (r = 0.91). Biochemically derived lipid content also increased with prolonged exposure to ethanol (r = 0.96). The averages of MRS derived lipid content agreed well with the average changes in biochemically determined total lipid concentration. Histologic examination revealed slight to moderate changes in fatty accumulation with significant variation in the group at the end of the study. On an individual basis the MRS and histologic evaluation were highly correlated (r = 0.94).

Animals↗

Dose-response characteristics of a ferrous-sulphate-doped gelatin system for determining radiation absorbed dose distributions by magnetic resonance imaging (Fe MRI).

The nuclear magnetic resonance (NMR) longitudinal relaxation rate R1 dose-response characteristics of a ferrous-sulphate-doped chemical dosimeter system (Fe MRI) immobilized in a gelatin matrix were explored. Samples containing various concentrations of the FeSO4 dosimeter were irradiated to absorbed doses of 0-150 Gy. R1 relaxation rates were determined by imaging the samples at a field strength of 1.5T(1H Lamor frequency of 63.8 MHz). The response of the system was found to be approximately linear up to doses of 50 Gy for all FeSO4 concentrations studied (0.1-2.0 mM). Changing concentrations in the range of 0.1-0.5 mM affected both the slope and intercept of the dose-response curve. For concentrations of 0.5-2.0 mM, the slope of the dose-response curves remained constant at approximately 0.0423 s-1 Gy-1 in the dose range of 0-50 Gy. However, the intercept of the curve continued to increase in that region, as expected, because of the additional paramagnetic ions. The reproducibility of the absorbed dose estimates for measurements made over a 22 cm field of view was found to be 5% in the range of 20-50 Gy (an uncertainty of 0.81 Gy on average), decreasing to approximately 10% in the dose range of 5-10 Gy.

Dose-Response Relationship, Radiation↗

Chronic carbon tetrachloride and phospholipase D hepatotoxicity in rat: in vivo 1H magnetic resonance, total lipid analysis, and histology.

Magnetic resonance (MR) imaging, localized in vivo proton spectroscopy, and T1 relaxation measurements were obtained from the livers of rats treated chronically with carbon tetrachloride and phospholipase D. The MR data correlated well with lipid changes measured biochemically and histologically. MR images appeared generally hyperintense during fatty infiltration, changing to hypointense mottling during cirrhosis. Water T1 relaxation times showed no statistically significant change at any time during the experiments from the control value of 908 ms (SE = 42 ms). Minor changes in lipid T1 values with time were noted. The average lipid T1 curve demonstrated a linear relation with time (r = 0.81), increasing from the control value of 283 ms (+/- 16 ms) to 365 ms (+/- 53 ms) at the end of the third week and decreasing slightly through the end of the experiment. Water-suppressed in vivo spectra showed quantitative changes in liver lipids which correlated well with the biochemical and histologic analysis. From the MR images and spectroscopy results it was possible to distinguish early fatty liver from more advanced cirrhosis.

Animals↗

Histopathologic correlation of magnetic resonance imaging signal patterns in a spinal cord injury model.

Magnetic resonance imaging (MRI) provides a noninvasive method of monitoring the pathologic response to spinal cord injury. Specific MR signal intensity patterns appear to correlate with degrees of improvement in the neurologic status in spinal cord injury patients. Histologic correlation of two types of MR signal intensity patterns are confirmed in the current study using a rat animal model. Adult male Sprague-Dawley rats underwent spinal cord trauma at the midthoracic level using a weight-dropping technique. After laminectomy, 5- and 10-gm brass weights were dropped from designated heights onto a 0.1-gm impounder placed on the exposed dura. Animals allowed to regain consciousness demonstrated variable recovery of hind limb paraplegia. Magnetic resonance images were obtained from 2 hours to 1 week after injury using a 2-tesla MRI/spectrometer. Sacrifice under anesthesia was performed by perfusive fixation; spinal columns were excised en bloc, embedded, sectioned, and observed with the compound light microscope. Magnetic resonance axial images obtained during the time sequence after injury demonstrate a distinct correlation between MR signal intensity patterns and the histologic appearance of the spinal cord. Magnetic resonance imaging delineates the pathologic processes resulting from acute spinal cord injury and can be used to differentiate the type of injury and prognosis.

Animals↗

In vivo localized proton spectroscopic studies of human gastrocnemius muscle.

In vivo proton magnetic resonance spectroscopy studies of gastrocnemius muscle were performed in six normal volunteers. Both spatially resolved spectroscopy (SPARS) and stimulated echo acquisition mode (STEAM) sequences were used for volume localization. A number of water suppression sequences have been combined with these localization schemes. Among the various techniques investigated in these studies, STEAM with an inversion pulse (T1-discriminated spectrum) seems to have the best potential for in vivo localized high-resolution proton spectroscopy studies of human muscle.

Adult↗

Comparative ultraviolet action spectra (254-320 nm) of five "wild-type" eukaryotic microorganisms and Escherichia coli.

The action spectra of five eukaryotic organisms and the prokaryote, Escherichia coli, were examined over the wavelength range, 254-320 nm. Both the repair competent and three repair defective strains (E. coli, Caenorhabditis elegans, Saccharomyces) were examined. Tetrahymena pyriformis action spectra were performed with and without the excision repair inhibitor caffeine present. Others have observed that lethality, mutation, and the production of pyrimidine dimers show much the same wavelength dependence as DNA absorption. The results presented here demonstrate several action spectra which deviate from the DNA absorption spectra. Ultraviolet sensitization ratios (repair competent/repair defective) were also examined and were shown to change over the wavelength range. These findings suggest that DNA may not be the only important chromophore leading to cell death in the uv wavelength range studied. Since uv-B is of major importance in solar uv damage, these findings may also yield important implications for solar uv studies.

Animals↗

Selection of MR images for automated segmentation.

MR images show a large range of contrast for various tissues in the body and are ideal for multispectral segmentation. Typically, only two MR images (dual-echo series) are used for segmentation; however, other images are often available. We evaluated MR images from 40 patients to determine the optimal type and number of images required for segmentation of tissues associated with brain tumors (normal brain, edema, necrosis, and active tumor). Pattern recognition methods indicated that three MR images from the same slice location were adequate for segmentation, as defined by feature selection and feature extraction measures based on training fields. This result was also confirmed by visually examining segmented images for all 40 patients. This work demonstrates that by using existing image/statistical analysis techniques (feature selection and feature extraction), one can systematically determine the optimal type and number of MR images for tissue segmentation.

Brain Neoplasms↗

Dynamic imaging of intracranial lesions using fast spin-echo imaging: differentiation of brain tumors and treatment effects.

The purpose of this study was to develop a technique for differentiating between recurrent brain tumors and treatment-related changes, such as radiation necrosis, using dynamic MRI. Ninety-five patients with intracranial mass lesions were evaluated using T1-weighted fast spin-echo (FSE) MRI at 1.5 T. Pathologies included treatment-related changes (n = 32), primary tumors (n = 41), metastatic tumors (n = 5), meningiomas (n = 4), and mixed primary/treatment related changes (n = 13). Signal enhancement-time curves were analyzed by fitting to a sigmoidal-exponential function. Maximal enhancement rates were calculated as the first derivative of the fitted curve. Based on the maximal enhancement rates, treatment-related changes could be differentiated from primary tumors, metastatic tumors, and meningiomas at the P < .05 confidence level. Lesions of mixed tumor and treatment-related change had intermediate values. Dynamic MRI can be used to differentiate treatment-related changes from primary tumors in previously treated patient populations based on maximal enhancement rates. Individual case studies demonstrate the clinical significance of these findings.

Adolescent↗

In vivo 1H spectroscopic studies of human gastrocnemius muscle at 1.5 T.

In vivo high resolution 1H magnetic resonance spectra are observed from the gastrocnemius muscle in 12 normal volunteers. The gross spectral features do not appear to significantly change from individual to individual. However, the number and the relative amplitudes of the resonances from the fatty acid chains are found to exhibit significant variation from normal to normal. The spectra observed on different occasions in the same individual exhibit very little variation. Our studies indicate that it is preferable to use the spin echo sequence with a long echo time to observe water-suppressed proton spectra from the muscle tissue.

Adult↗

In vivo muscle magnetic resonance spectroscopy in a family with mitochondrial cytopathy: a defect in fat metabolism.

In vivo proton and phosphorus magnetic resonance spectroscopy (MRS) studies were performed at 1.5 T on two patients (siblings) diagnosed as having a mitochondrial cytopathy. The clinical diagnosis was based on a complete battery of biochemical tests, electron microscopy and modified Gomori trichrome stain studies of muscle. Proton spectra from the gastrocnemius muscle were recorded using the stimulated echo acquisition mode (STEAM) and the phosphorus spectra were obtained using the depth-resolved surface coil spectroscopy (DRESS) sequence. Proton resonances from neutral fats in the patients were found to be strikingly weak compared to normals. The ratios [PCr]/[ATP] and [PCr]/[Pi] and the pH values, as inferred from the phosphorus MRS, were found to be marginally decreased compared to normals. These studies indicate defective fatty acid metabolism in these two patients. It is, however, not known whether the abnormal mitochondrial ultrastructure represents a primary abnormality or secondary to defective fatty acid metabolism.

Adult↗

Electron beam central axis depth dose measurements.

Central axis depth dose measurements were made by the Radiological Physics Center on over 70 electron-producing machines used in radiation therapy. These data were consistent for each machine model and nominal energy. However, the data show that depth dose relations can vary significantly among different machine models for electron beams having the same nominal energy. Analysis shows that both the method used to achieve beam flatness and the mean incident electron energy determine the central axis depth dose curve past the depth of maximum dose. A linear relation of depth dose versus mean incident electron energy is used to predict depth dose to within 2 mm for most electron beams used clinically at depths greater than d95.

Calibration↗

Results of photon absorbed-dose measurements using the AAPM TG-21 protocol for accelerating potentials up to 26 MV.

The AAPM Task Group 21 protocol for the calibration of high-energy photon and electron beams was produced to accomplish essentially two goals: (1) incorporate the latest physical data available for calculating absorbed dose from ionization measurements and (2) to eliminate inconsistencies in absorbed dose measurements made with various ion chamber and phantom combinations. The ability of the protocol was assessed to consistently determine x-ray absorbed dose from measurements made with four Farmer-type chambers and one parallel-plate chamber in water, polystyrene, and acrylic phantoms. The measurements were performed using seven high-energy x-ray beams from 60Co to 26-MV nominal accelerating potential. The absorbed dose to water calculated from measurements made with the various chamber and phantom combinations were found to be consistent. The doses calculated for the two most common phantom materials, water and polystyrene, were found to be in excellent agreement. This resolved a 1.6% discrepancy in the absorbed dose determined from the two phantoms using the SCRAD protocol. The doses for acrylic phantoms were found to be approximately 1.2%, low for nominal accelerating potentials less than 8.8 MV. For accelerating potentials of 8.8 MV or greater the agreement was considerably better. The mean dose determined for the parallel-plate chamber from measurements in polystyrene was found to be within 0.7% of the mean dose determined using Farmer-type ion chambers in all phantom materials.

Humans↗

Introduction to wavelet-based compression of medical images.

Medical image compression can significantly enhance the performance of picture archiving and communication systems and may be considered an enabling technology for telemedicine. The wavelet transform is a powerful mathematical tool with many unique qualities that are useful for image compression and processing applications. Although wavelet concepts can be traced back to 1910, the mathematics of wavelets have only recently been formalized. By exploiting spatial and spectral information redundancy in images, wavelet-based methods offer significantly better results for compressing medical images than do compression algorithms based on Fourier methods, such as the discrete cosine transform used by the Joint Photographic Experts Group. Furthermore, wavelet-based compression does not suffer from blocking artifacts, and the restored image quality is generally superior at higher compression rates.

Humans↗