Search PubMedSearch

Biomedical subjects

J D Eick

Publications and source records attributed to J D Eick.

At least 19 recordsLinked to original sources

Effect of two dentin bonding agents on microleakage in two different cavity designs.

Studies have shown that cavity design and dentinal bonding agents can affect composite resin microleakage. This study compared the microleakage at cementum-dentin margins of box- and Vshaped preparations restored with two different bonding agents. Twenty freshly extracted, human third molars were prepared with one box-shaped and one V-shaped preparation on the mesial or distal surface. Occlusal margins were terminated in etched enamel and gingival margins were in cementum-dentin. There was no statistically significant difference (p greater than 0.05) between Dual Cure Scotchbond and Scotchbond 2 samples restored in the box-shaped preparations, but Scotchbond 2 had statistically significantly less microleakage (p less than 0.05) than Dual Cure adhesive in V-shaped preparations. The sealing of dentinal bonding agents varied in different cavity designs.

Adhesives

Accuracy of one-step versus two-step putty wash addition silicone impression technique.

This study compared the accuracy of one-step putty wash with two-step putty wash impression techniques. Five addition silicone impression materials-Mirror 3 (MR), Mirror 3 Extrude (ME), Express (E), Permagum (P), and Absolute(A)--were tested. A stainless steel model containing two full-crown abutment preparations was used as the positive control. Five replications for one-step and two-step putty wash impressions of the master model were made for each test material. Accuracy of the materials was assessed by measuring six dimensions on stone dies poured from impressions of the master model. Accuracy of addition silicone impression material is affected more by material than technique. Accuracy of the putty wash one-step impression technique was not different from the putty wash two-step impression technique except at one of the six dimensions where one-step was more accurate than two-step. Mirror 3 putty wash two-step impression presented less distortion than Mirror 3 Extrude putty wash one-step or two-step impression.

Analysis of Variance

Synthesis and polymerization of new expanding dental monomers.

The objective of this work was to develop polymeric materials that expand slightly upon polymerization and that could potentially be used as matrix resins for dental composites. A series of stereoisomeric alicyclic spiroorthocarbonates (SOC's) that expand when polymerized were synthesized. Three of these SOC racemates were analyzed: cis/cis-, cis/trans- and trans/trans-2,3,8,9-di(tetramethylene)-1,5,7,11-tetraoxaspiro[5.5] undecane. The degrees of expansion, approximately 3.9% and 3.5%, for the cis/cis and trans/trans, were determined by measuring the specific volume of the monomers and polymers in dilute solutions. This method of determining densities and subsequent calculated expansion or shrinkage was validated by duplicating the reported shrinkage of 4-tert-butylphenyl glycidyl ether, styrene, and methyl methacrylate. Based on these data and spectral data obtained using other analytical techniques, these stereoisomeric alicyclic SOC's appear to have potential as nonshrinking polymer or copolymer matrices for dental composites.

Chromatography, Gas

Chemical characterization of the dentin/adhesive interface by Fourier transform infrared photoacoustic spectroscopy.

Irreversible bonding of composite materials to tooth structure depends on chemical as well as mechanical adhesion. The proposed bonding mechanism for several commercial dental adhesives is chemical adhesion to the dentin surface. The purpose of this in vitro investigation was to characterize the chemical nature of the surface interaction between dentin and two commercial adhesives by use of Fourier transform infrared photoacoustic spectroscopy (FTIR/PAS). The occlusal thirds of the crowns of freshly extracted, non-carious, unerupted human molars were sectioned perpendicular to the long axis. Dentin disks, 6 mm x 2 mm, were prepared from these sectioned teeth. The exposed dentin surface was treated with either Scotchbond 2, a BIS-GMA resin, or Dentin-Adhesit, a polyurethane resin. All spectra were recorded from 4000 to 400 cm-1 by use of an Analect RFX-65 FTIR spectrometer equipped with an MTEC Photoacoustics Model 200 photoacoustic cell. An initial spectrum of the dentin surface was collected. This surface was primed according to manufacturer's instructions and spectra recorded of the primed surface plus one to three layers of adhesive. By comparison of these spectra, it was possible for us to record changes in the phosphate and amide I and II bands due to surface interactions between the adhesive and the dentin. Although early results do not indicate covalent bonding between the dentin and these adhesives, this technique presents several advantages for spectroscopic evaluation of the dentin/adhesive interface.

Acrylic Resins

Bone hole diameter as a function of drill guide length and drilling method in rigid internal fixation.

This study examines drill guide length and drilling method to see which technique produces the most accurate hole diameter. Two hundred twenty-five holes were produced in fresh porcine mandibles and then measured with a micrometer. A long guide, a short guide, and no guide were used with a drill press, a pneumatic drill, and a manual drill. Using a 2-mm drill bit, the overall average diameter was 2.03 mm and the overall range was 1.85 mm to 2.60 mm. Statistical analysis of the data indicates the drilling method and the guide length made no difference in the hole diameter at the 95% level (P = .05).

Analysis of Variance

Smear layer--materials surface.

SEM and TEM photomicrographs were presented of the smear layer and several dentin-adhesive interfaces. It was shown that as the wetting and penetration of the dentin adhesive increased, the shear bond strength also increased. Three categories of dentin adhesives were presented. Category one included Scotchbond, Dentin Adhesit and Gluma, with shear bond strength values between 5 and 7 MPa; the second category, dentin adhesives based on Dr. Bowen's research, included Tenure and Mirage Bond, with shear bond strengths between 8 and 14 MPa; the third category included Superbond and Scotchbond 2, with shear bond strength values up to 20 MPa. Failures occurred at the interface or in the resin adhesive for materials in categories one and two; failures occurred through the dentin or composite for materials in category three.

Adhesives

The dentinal surface: its influence on dentinal adhesion. 2.

The first paper in this series presented a categorization of dentinal adhesive systems that was organized roughly according to chronology, chemistry, and shear bond strength values. Category I dentinal adhesives demonstrate the lowest shear bond strength values, approximately 5 to 7 MPa. Category II dentinal adhesives, including experimental ferric and aluminum oxalate pretreatments and two commercial products, demonstrate shear bond strength values between 8 and 14 MPa. This second category of dentinal adhesives is the subject of this paper. An attempt is made to draw a parallel between the penetrative ability of the adhesive (the wettability of the dentinal substrate) and the efficacy of the adhesive bond as determined by shear bond strength values. Category III dentinal adhesives will be discussed in another paper.

Adhesives

Indirect determination of isocyanates by gas chromatography.

A gas chromatographic method was developed to determine the purity of synthesized isocyanate monomers, specifically isocyanatoacrylates, and to determine the isocyanate content of synthesized polymers and prepolymers. The method is a modification of an ASTM procedure in which an isocyanate is allowed to react with excess di-n-butylamine. In the ASTM method, the amount of isocyanate present is calculated indirectly from the amount of unreacted di-n-butylamine, determined by back titration with standard hydrochloric acid. Determination of the excess di-n-butylamine by the gas chromatographic method developed has the advantages of providing better precision and requiring less sample than the titrimetric method. The two methods were compared using phenyl isocyanate as a model test compound. A synthesized monomer, methyl alpha-isocyanatoacrylate, was also analyzed, for comparison by both methods.

Chromatography, Gas

Stereophotogrammetric analysis of abutment tooth movement in distal-extension removable partial dentures with intracoronal attachments and clasps.

This study applied the three-dimensional measurement technique of stereophotogrammetry to measure abutment tooth movement under occlusal loading as a function of intracoronal attachment and clasp design. Six distal-extension removable partial denture designs were studied: (1) RPI-mesial occlusal rest, proximal plate, buccal I-bar; (2) cast circumferential clasp; (3) P.D. locking semiprecision attachment; (4) Thompson dowel nonlocking semiprecision attachment; (5) McCollum precision attachment; and (6) Stern G/L precision attachment. The movement in microns was determined by computer analysis. The Thompson dowel semiprecision attachment generated the most abutment movement in a gingival direction. The clasp-retained designs generally had less total movement than the attachment designs. Clasps and attachments for the abutment teeth adjacent to the distal-extension bases generally moved more than the abutment teeth.

Analysis of Variance

Comparison of two-surface and multiple-surface scoring methodologies for in vitro microleakage studies.

Investigators differ on the use of a two-surface or multiple-surface scoring methodology in sectional microleakage studies. This study compared microleakage scores using both two-surface and multiple-surface scoring methods for two preparation types and two different dentin bonding agents. Twenty freshly extracted molars each received one box-shaped and one V-shaped restoration on the mesial or distal surface. Each restoration was cut occlusogingivally into four sections, yielding eight surfaces for scoring. Surfaces were marked to identify central (I), lateral (II), and end (III) locations, then scored by two calibrated raters. The Wilcoxon Matched-Pairs Signed-Rank Test showed a statistically significant difference (p less than or equal to 0.05) in median microleakage scores obtained by an end two- surface and multiple-surface evaluation for V-shaped preparations restored with Scotchbond 2, P-50. No other statistically significant comparisons were detected. Results suggest that microleakage may be more extreme at end surfaces and that these end surfaces should be scored so that an accurate microleakage value could be assigned to composite restorations.

Analysis of Variance

The dentinal surface: its influence on dentinal adhesion. Part I.

Three categories of dentinal adhesive are proposed: category I includes adhesives with shear bond strength values between 5 and 7 MPa; category II includes dentinal adhesives with shear bond strengths between 8 and 14 MPa; and category III includes adhesives with shear bond strength values up to 20 MPa. In part I of this article, photomicrographs of the dentinal smear layer and three category I first-generation dentin-adhesive interfaces are presented. The photomicrographs show that the wetting and penetration of the first-generation dentinal adhesives were not adequate to produce high shear bond strengths. When the category I adhesives were tested for shear bond strength, failures occurred at the interface or in the resin adhesive. Future articles will explain wetting and adhesive performance of category II and III adhesives.

Acrylic Resins

The effect of storage and thermocycling on the shear bond strength of three dentinal adhesives.

The purpose of this investigation was to evaluate the effects of time of storage and thermocycling on the shear bond strength of three dentinal adhesives. The shear bond strength of Mirage Bond was significantly greater than that of Scotchbond 2, which was significantly greater than that of Scotchbond Dual Cure (P less than or equal to .05). Thermocycling significantly lowered the shear bond strength of Scotchbond Dual Cure and Scotchbond 2, but not that of Mirage Bond (P less than or equal to .05). Time of storage did not affect the shear bond strength of the other adhesives, but Mirage Bond had a significantly greater shear bond strength after 1 month of storage (P less than or equal to .05). Scanning electron microscopic observations showed that the fracture patterns were all at the smear layer-adhesive interface for Scotchbond Dual Cure, the majority of the fractures were at the primer-adhesive interface for Scotchbond 2, and most of the fractures were cohesive in the bonding agent for Mirage Bond.

Analysis of Variance

Marginal fit of porcelain-fused-to-metal and two types of ceramic crown.

The marginal fit of Dicor, Cerestore, and porcelain-fused-to-metal crowns was evaluated. Ten premolars free of caries were prepared for each type of restoration and crowns were made. The vertical marginal openings were measured before cementation, after cementation, and after thermocycling. There were statistically significant differences between all three test conditions in each type of crown, between Dicor and porcelain-fused-to-metal crowns after cementation and after thermocycling, and between Cerestore and porcelain-fused-to-metal crowns after thermocycling. All 30 cemented crowns were then embedded in acrylic resin for serial sections for measurement of absolute marginal openings. Statistically significant differences between Dicor and Cerestore crowns and between Cerestore and porcelain-fused-to-metal crowns were found. It was concluded that marginal openings increased after cementation and after thermocycling, and porcelain-fused-to-metal crowns had significantly better marginal fit than that of Dicor and Cerestore crowns.

Aluminum

Mechanical behavior of mandibular continuity defects reconstructed using combinations of hydroxylapatite and autogenous bone.

The purpose of this investigation was to determine the mechanical behavior of primate (Macaca mulatta) mandibles with continuity defects reconstructed using varying ratios of an alloplastic hydroxylapatite (HA) implant material mixed with autogenous bone (AB). The defects were allowed to heal for 6 and 18 months before killing the animals and mechanical testing. Each animal had one side of the mandible restored with 100% AB as control. The fracture strength and section modulus of the opposite side of the mandible, containing the test ratio of HA-AB, were directly compared with the mechanical behavior of the control side. The fracture strength and section modulus were evaluated by a cantilever type of mechanical test that took into account the anisotropic, viscoelastic, and geometric nature of the mandible. The type of bone and tissue at the fracture site was examined by scanning electron microscopy and a direct correlation between the amount of bone and/or fibrous tissue growth around the HA implant material and the fracture strength and section modulus values was established. The average fracture strength of the AB graft sites at 18 months was 9,975 +/- 4,300 psi, with ratios of 25:75 and 50:50 HA-AB giving test results approaching those of the AB graft sites.

Alveolar Ridge Augmentation

Restoration of mandibular continuity defects using combinations of hydroxylapatite and autogenous bone: microscopic observations.

The purpose of this investigation was to assess by light, transmission, and scanning electron microscopy the healing of mandibular continuity defects reconstructed with varying ratios of an alloplastic hydroxylapatite implant material (HA) mixed with autogenous bone (AB). This study reports the microscopic observations of implant and control sites at 6 and 18 months postsurgery. The results confirm the biocompatibility of dense HA granules. Specimens exhibited differing degrees of osseous regeneration that appeared related to the percent composition of HA. At 18 months, 86% and 91% of the HA granules were completely surrounded by bone in those specimens reconstructed with implants consisting of 25% and 50% HA, respectively. In contrast, specimens receiving implants consisting of 75% and 100% HA features osseous encapsulation of 75% and 66% of the granules, respectively. The results of this limited study indicate that dense HA granules mixed with AB in ratios ranging from 3:1 to 1:1 (AB:HA) may be successfully used as a bone extender during reconstructive surgery.

Animals

Fracture strength of Class I versus Class II restored premolars tested at the marginal ridge. I. Standard preparations.

Two groups of maxillary premolars with Class I cavities were prepared with one marginal ridge thickness to a width of 1.0 mm. One group was restored with amalgam and the other group with composite resin. Two groups of Class II cavities also were prepared and restored with amalgam and composite resin. The teeth in the four treatment groups were subjected to a centric load at the marginal ridge until fracture occurred. A two-factor analysis of variance revealed a statistically significant difference between the class of preparation (Class I preparations were weaker than were Class II preparations) but differences in strength between restorative materials (composite resin versus amalgam) and the interaction effect (class of preparation x restorative materials) were not found to be statistically significant (alpha = .05). A Newman-Keuls sequential range test found no statistically significant differences in strength between groups (alpha = .05). Fracture patterns were observed under scanning electron microscope. Fractures extended into the enamel and into the material in the Class I composite resin, Class I amalgam, and Class II composite resin restorations. Fractures extended only into the material in Class II amalgam restorations.

Bicuspid

Fracture strength of Class I versus Class II restored premolars tested at the marginal ridge. 2. Cavosurface bonding and cavosurface plus internal enamel bonding.

The purpose of this study was to test the difference between the strength of the marginal ridge of extracted teeth with a Class I composite resin restoration and the strength of the marginal ridge of teeth with a Class II amalgam restoration with retention grooves. A statistically significant difference in fracture strengths was found among groups. No statistically significant difference was found among restored preparations, beveling technique, and restorative material. Statistically significant differences in fracture strength were found between the whole tooth group and treatment groups; between the whole tooth group and Class II amalgam restoration group; and between the unrestored tooth preparation group and all other tooth groups.

Acid Etching, Dental

The effect of time on the adhesion of light-body to heavy-body Express in the two-step reline polyvinylsiloxane impression technique.

Often times light-body wash (LB) cannot be added to the heavy-body putty (HB) within 30 minutes when utilizing the two-step reline impression technique. The purpose of this study was to add the LB to the HB at times greater than 30 minutes and test the tensile bond strength. A split aluminum mold which created a bonding area of 1.13 cm2 and tray were filled with Express HB. After HB set the Express LB in a tray was added at varying times. The split molds were then separated and samples tested on the Instron. Ten groups with five samples/group (determined by a pilot study) were made. The times which the LB was added to the set HB and tested were: A) Immediately (one-step procedure); B) 10 minutes and contaminated with saliva (negative control); C) 10 minutes; D) 30 minutes; E) 45 minutes; F) 1 hour; G) 3 hours; H) 24 hours; I) 115 hours; and J) Freshened after 3 months. The results of this study indicate that saliva-contaminated samples were weaker than all other groups (P less than or equal to 0.01) and as far as tensile bond strength between materials is concerned, there appears to be no detrimental effect in tensile bond strength between HB and LB when delaying the application of the light-body material (P less than or equal to 0.01).

Dental Bonding