Search PubMed⌕ Search

Biomedical subjects

J D Catalano

Publications and source records attributed to J D Catalano.

12 recordsLinked to original sources

Treatment of the sequelae of pilon fractures.

Intra-articular fractures of the distal end of the tibia represent a wide spectrum of articular and metaphyseal damage and are relatively infrequent injuries. This article summarizes possible early and late complications involved in the treatment of pilon fractures. Diagnostic and treatment guidelines for these complications also are reviewed.

Fracture Fixation↗

Strabismus.

Patients with strabismus should be viewed as having a serious ocular disorder requiring early diagnosis and evaluation. They should also be encouraged to have proper therapy so that they may be returned to a more normal ocular status at the earliest possible age. The ultimate goal of the pediatric ophthalmologist is always good vision and proper alignment. Neither alone is acceptable. The pediatric practitioner should diagnose strabismus disorders at the earliest possible age so that full and proper treatment may be brought to bear, thus allowing the patient to enjoy binocular vision function throughout life.

Aging↗

Strabismus.

Explore the source record for details and available documents.

Child↗

Dyslexia update.

Explore the source record for details and available documents.

Child↗

An evaluation of short-term exposures to metalworking fluids in small machine shops.

In a study of 23 small machining shops using metalworking fluids (MWFs), real-time air monitoring using an aerosol photometer was performed to investigate the temporal nature of the exposure and to examine the relationship between the instrumental measurements and traditional sampling methods. Time-weighted averages were calculated from the aerosol photometer data and the results were compared to collocated thoracic and 37-mm closed face cassette samplers. The filter samples were analyzed for total mass and the solvent extractable fraction. Depending on the averaging period used, short-term MWF concentrations exceeded 2.0 mg/m3 in 13 to 39% of the plants studied. High short-term exposures were as likely to be found in plants with average concentrations below 0.4 mg/m3 (thoracic-gravimetric) as those above. Regression analyses indicated that the aerosol photometer most closely matched the data obtained from the thoracic fraction of the total mass. In general, the aerosol photometer overestimated the levels determined using the thoracic cyclone and filter, especially when measuring concentrations of water-based fluids. Use of a calibration factor of 0.7 for straight oils or 0.5 for water-based fluids may assist in the interpretation of aerosol photometer measurements if field calibration data are not readily available. Several approaches to determining the calibration factor from field data were evaluated; more complex calibration techniques improved the accuracy of the measurements.

Aerosols↗

Metalworking fluid exposures in small machine shops: an overview.

Sampling was conducted in 79 small machine shops to assess airborne exposures to metalworking fluids (MWFs). Measured exposures were compared with data from the literature and exposure criteria currently recommended by the National Institute for Occupational Safety and Health and the Occupational Safety and Health Administration MWF Standards Advisory Committee. Sixty-two percent of 942 personal samples collected were less than the recommended exposure limit (REL) of 0.50 mg/m3 for total particulate. However, at least 1 sample exceeded the REL in 61 of the 79 facilities studied; 100% of the samples collected in 10 shops were greater than the REL. Similar trends were found for thoracic particulate exposures where 75% of 238 samples were below the thoracic particulate REL of 0.40 mg/m3. The ratio between thoracic and total particulate for 238 paired samples was 0.55 (r2=0.73). Workers exposed to straight fluids had the highest exposures (GM=0.67 mg/m3) when compared with workers exposed to other classes of MWFs. The highest exposures were measured for grinding and hobbing (GM=0.67 and 0.60 mg/m3, respectively). Measurements using personal impactors indicated that particle size distributions of MWF aerosols had an average mass median aerodynamic diameter of 5.3 microm. Straight oils and soluble fluids tended to be associated with larger particles than were other fluid types; grinding and turning produced the largest particles, whereas hobbing resulted in the smallest. In general, exposures were similar in magnitude and particle size to those previously reported in large automotive plants. Therefore, workers in these small shops may have risks of adverse health effects similar to those demonstrated in the automotive industry.

Aerosols↗