Effect of microstructure on the dry sliding friction behavior of CoCrMo alloys used in metal-on-metal hip implants.

The microstructure and its effect on the friction behavior of a medical grade wrought cobalt-chromium-molybdenum (CoCrMo) alloy for surgical implants were studied in this work. In particular, the effects of compression and carbon (C) content on the above characteristics were analyzed. Increasing amounts of deformation resulted in a decrease in the number of annealing twins in the microstructures. In addition, there was an increase in the volume fraction of the hexagonal closed-packed (HCP) phase due to a strain-induced transformation (SIT) from the metastable face-centered cubic (FCC) phase. The high C (HC) alloy had a lower volume fraction of this SIT phase. Friction studies conducted on these alloys revealed a higher coefficient of friction for the HC alloy and no significant effect of SIT on the friction characteristics.

Chromium Alloys↗

The effect of microstructure on the wear of cobalt-based alloys used in metal-on-metal hip implants.

The influence of microstructure on the wear of cobalt-based alloys used in metal-on-metal hip implants was investigated in a boundary lubrication regime designed to represent the conditions that occurred some of the time in vivo. These cobalt-chromium-molybdenum alloys were either wrought, with a total carbon content of 0.05 or 0.23 wt %, cast with a solution-annealing procedure or simply as-cast but not solution annealed. Bars of these different alloy grades were subjected to various heat treatments to develop different microstructures. The wear was evaluated in a linear-tracking reciprocating pin-on-plate apparatus with a 25 per cent bovine serum lubricant. The wear was found to be strongly affected by the dissolved carbon content of the alloys and mostly independent of grain size or the carbide characteristics. The increased carbon in solid solution caused reductions in volumetric wear because carbon helped to stabilize a face-centred cubic crystal structure, thus limiting the amount of strain-induced transformation to a hexagonal close-packed crystal structure. Based on the observed surface twining in and around the contact zone and the potentially detrimental effect of the hexagonal close-packed phase, it was postulated that the wear of cobalt-based alloys in the present study was controlled by a deformation mechanism.

Biocompatible Materials↗

Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time.

Detailed characterization of wear particles is necessary to understand better the implant wear mechanisms and the periprosthetic tissue response. The purposes of the present study were to compare particle characteristics of current with older designs of metal-on-metal (MM) total hip replacements (THRs), and to determine the effect of implantation time on wear particle characteristics. Metal wear particles isolated from periprosthetic tissues from 19 patients with MM THRs of current and older designs and at different implantation times (very short, longer, and very long) were studied using transmission electron microscopy and energy dispersive X-ray analysis. The particles from the current design implants with implantation times of not more than 15 months (very short-term) were almost exclusively round to oval chromium oxide particles. In all other cases, although the predominance was still round to oval chromium oxide particles, greater proportions of cobalt-chromium-molybdenum (Co-Cr-Mo) particles, mainly needle-shaped, were detected. Very long-term THRs implanted for more than 20 years had the highest percentage of needle-shaped Co-Cr-Mo particles. Particle lengths were not markedly different between the different designs and implantation times except for the current design implants of not more than 15 months, which had a significantly smaller mean length of 39 nm. In conclusion, the implant design did not seem to have a significant influence on particle characteristics whereas the implantation time appeared to have the most effect on the particles. It should be noted that, because of the limited number of tissue retrievals available, some uncertainty remains regarding the generality of these findings.

Adult↗

Zoledronic acid causes enhancement of bone growth into porous implants.

The effect of zoledronic acid on bone ingrowth was examined in an animal model in which porous tantalum implants were placed bilaterally within the ulnae of seven dogs. Zoledronic acid in saline was administered via a single post-operative intravenous injection at a dose of 0.1 mg/kg. The ulnae were harvested six weeks after surgery. Undecalcified transverse histological sections of the implant-bone interfaces were imaged with backscattered scanning electron microscopy and the percentage of available pore space that was filled with new bone was calculated. The mean extent of bone ingrowth was 6.6% for the control implants and 12.2% for the zoledronic acid-treated implants, an absolute difference of 5.6% (95% confidence interval, 1.2 to 10.1) and a relative difference of 85% which was statistically significant. Individual islands of new bone formation within the implant pores were similar in number in both groups but were 69% larger in the zoledronic acid-treated group. The bisphosphonate zoledronic acid should be further investigated for use in accelerating or enhancing the biological fixation of implants to bone.

Animals↗

Acid-etched microtexture for enhancement of bone growth into porous-coated implants.

We designed an in vivo study to determine if the superimposition of a microtexture on the surface of sintered titanium beads affected the extent of bone ingrowth. Cylindrical titanium intramedullary implants were coated with titanium beads to form a porous finish using commercial sintering techniques. A control group of implants was left in the as-sintered condition. The test group was etched in a boiling acidic solution to create an irregular surface over the entire porous coating. Six experimental dogs underwent simultaneous bilateral femoral intramedullary implantation of a control implant and an acid etched implant. At 12 weeks, the implants were harvested in situ and the femora processed for undecalcified, histological examination. Eight transverse serial sections for each implant were analysed by backscattered electron microscopy and the extent of bone ingrowth was quantified by computer-aided image analysis. The extent of bone ingrowth into the control implants was 15.8% while the extent of bone ingrowth into the etched implants was 25.3%, a difference of 60% that was statistically significant. These results are consistent with other research that documents the positive effect of microtextured surfaces on bone formation at an implant surface. The acid etching process developed for this study represents a simple method for enhancing the potential of commonly available porous coatings for biological fixation.

Animals↗

Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings.

The purpose of the current study was to ascertain the relative contributions of surface chemistry and topography to the osseointegration of hydroxyapatite-coated implants. A canine femoral intramedullary implant model was used to compare the osseous response to commercially pure titanium implants that were either polished, grit-blasted, plasma-sprayed with hydroxyapatite, or plasma-sprayed with hydroxyapatite and masked with a very thin layer of titanium using physical vapor deposition (titanium mask). The titanium mask isolated the chemistry of the underlying hydroxyapatite layer without functionally changing its surface topography and morphologic features. At 12 weeks, the bone-implant specimens were prepared for undecalcified thin section histologic evaluation and serial transverse sections were quantified with backscattered scanning electron microscopy for the percentage of bone apposition to the implant surface. Bone apposition averaged 3% for the polished implants and 23% for the grit-blasted implants. Bone apposition to the hydroxyapatite-coated implants averaged 74% whereas bone apposition to the titanium mask implants averaged 59%. Although there was significantly greater osseointegration with the hydroxyapatite-coated implants, 80% of the maximum bone forming response to the implant surfaces developed with the titanium mask implants. This simple, controlled experiment revealed that topography is the dominant factor governing bone apposition to hydroxyapatite-coated implants.

Animals↗

Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. I. Analysis of particle size and shape.

Isolation of metal wear particles from hip simulator lubricants or tissues surrounding implants is a challenging problem because of small particle size, their tendency to agglomerate, and their potential for chemical degradation by digestion reagents. To provide realistic measurements of size, shape, and composition of metal wear particles, it is important to optimize particle isolation and minimize particle changes due to the effects of the reagents. In this study (Part I of II), transmission electron microscopy (TEM) was used to examine and compare the effects of different isolation protocols, using enzymes or alkaline solutions, on the size and shape of three different types of cobalt-based alloy particles produced from metal-metal bearings. The effect on particle composition was examined in a subsequent study (Part II). Large particles (<1200 nm) were generated by dry abrasion of CoCrMo alloy against itself and small particles (<300 nm) were generated by hip simulator testing of a metal-metal implant pair in the presence of either distilled-deionized water or a 95% bovine serum solution. The reagents changed particle size and to a lesser extent particle shape. For both large particles and small particles generated in water, the changes in size were more extensive after alkaline than after enzymatic protocols and increased with alkaline concentration and time in solution, up to twofold at 2 h and threefold at 48 h. However, when isolating particles from 95% serum, an initial protective effect of serum proteins and/or lipids was observed. Because of this protective effect, there was no significant difference in particle size and shape for both oval and needle-shaped particles after 2 h in 2N KOH and after enzymatic treatments. However, round particles were significantly smaller after 2 h in 2N KOH than after enzymatic treatments. Particle composition may also have been affected by the 2N KOH treatment, as suggested by a difference in particle contrast under TEM, an issue examined in detail in Part II.

Animals↗

Effects of digestion protocols on the isolation and characterization of metal-metal wear particles. II. Analysis of ion release and particle composition.

The isolation of metal wear particles from hip simulator lubricants is important for understanding wear mechanisms and the tissue response to particulate material. Part I of this study demonstrated that isolation protocols involving digestion reagents can chemically attack metal-metal wear particles, reducing their size and changing their shape. In part II of this study, Co and Cr ion concentrations in solution after each digestion protocol were measured by flame atomic absorption spectrometry, and wear particle composition was determined by X-ray analysis spectra. The exposure of wear particles in water to alkaline solutions caused an increasing release of Cr ions in solution with alkaline concentration and time, and a corresponding decrease in particle Cr peak intensity on X-ray spectra. As a result, particles exposed to 12N KOH for 48 h displayed Co peaks and no Cr. In contrast, enzymatic protocols caused a release of Co ions in solution and a corresponding decrease in particle Co peak intensity on X-ray spectra, especially with sodium phosphate as a buffer. However, when isolating particles from 95% serum, there was an initial protective effect of serum proteins, presumably because of their binding to Co and Cr. As a result, the extent of Cr ion release from metal wear particles in 95% serum after alkaline treatments was diminished, although still present, whereas both enzymatic protocols resulted in a negligible release of Co and Cr ions into solution. Particle composition analysis after enzymatic treatments revealed the presence of chromium oxide particles and CoCrMo particles with variable Co/Cr ratios. After alkaline treatments, the chromium oxide particles increasingly disappeared with time and alkaline concentration, demonstrating a change in particle composition after these treatments. This study demonstrated that digestion reagents can induce chemical changes that affect particle composition. Of all the protocols tested, the enzymatic protocols were the least damaging to the particles and appeared to be the best compromise for isolation and characterization of metal particles, especially in 95% serum. Special care on the choice of buffers should be taken when isolating particles from a lower concentration of serum.

Animals↗

Enhancement of bone growth into porous intramedullary implants using non-invasive low intensity ultrasound.

An in vivo study was designed to determine if non-invasive low intensity ultrasound could enhance bone growth into porous intramedullary implants. Fully porous intramedullary rods were implanted bilaterally into the ulnae of six dogs. In each dog, one ulna served as a control and the other was treated with 20 min of daily ultrasound stimulation for 6 consecutive weeks. Analysis of serial transverse sections indicated an average of 119% more bone growth into the ultrasound-treated implants compared with the contralateral controls (P < 0.001). In each of the 6 dogs, there was a significantly greater amount of bone ingrowth on the ultrasound-stimulated side. These data indicate a clear potential for externally applied ultrasound therapy to augment biological fixation.

Animals↗

Femoral remodeling after porous-coated total hip arthroplasty with and without hydroxyapatite-tricalcium phosphate coating: a prospective randomized trial.

We prospectively assessed femoral bone remodeling using dual-energy x-ray absorptiometry for 2 years after total hip arthroplasty. Thirty-nine hips were randomized to receive a titanium proximally porous-coated femoral component with or without hydroxyapatite-tricalcium phosphate coating. Although both stems resulted in alterations in the periprosthetic bone mineral density, the hydroxyapatite-tricalcium phosphate coated stems had significantly less femoral bone loss than the uncoated stems at 2-year follow-up. This reduced femoral bone loss may provide short-term and long-term advantages over noncoated stems.

Absorptiometry, Photon↗

Primary cementless total hip arthroplasty using a modular femoral component: a minimum 6-year follow-up.

We evaluated 59 hips that underwent a primary total hip arthroplasty using an S-ROM modular femoral component at a mean follow-up of 101 months (range, 72-145 months). All cases showed radiographic evidence of bone ingrowth, and there were no femoral revisions for aseptic loosening. The Harris hip score improved from a mean of 40 preoperatively to 89 at final follow-up. Some degree of proximal femoral disuse atrophy from stress shielding occurred in 46 hips (78%), and some degree of femoral osteolysis occurred in 25 hips (42%). Only additional follow-up will reveal whether there is a consequence of both types of proximal femoral bone loss.

Adolescent↗

Fibrous tissue ingrowth and attachment to porous tantalum.

This study determined the soft tissue attachment strength and extent of ingrowth to a porous tantalum biomaterial. Eight dorsal subcutaneous implants (in two dogs) were evaluated at 4, 8, and 16 weeks. Upon retrieval, all implants were surrounded completely by adherent soft tissue. Implants were harvested with a tissue flap on the cutaneous aspect and peel tested in a servo-hydraulic tensile test machine at a rate of 5 mm/min. Following testing, implants were dehydrated in a solution of basic fuschin, defatted, embedded in methylmethacrylate, and processed for thin-section histology. At 4, 8, and 16 weeks, the attachment strength to porous tantalum was 61, 71, and 89 g/mm respectively. Histologic analysis showed complete tissue ingrowth throughout the porous tantalum implant. Blood vessels were visible at the interface of and within the porous tantalum material. Tissue maturity and vascularity increased with time. The tissue attachment strength to porous tantalum was three- to six-fold greater than was reported in a similar study with porous beads. This study demonstrated that porous tantalum permits rapid ingrowth of vascularized soft tissue, and attains soft tissue attachment strengths greater than with porous beads.

Animals↗

Potential errors in axial alignment using intramedullary instrumentation for total knee arthroplasty.

Accurate restoration of normal limb alignment is crucial for the long-term survivorship of total knee arthroplasty (TKA). A mathematical model was used to evaluate the maximum error in varus and valgus alignment that could occur when cutting the tibia or femur during TKA using intramedullary (IM) guides of varying length and diameter. Minor deviations in the insertion point of IM instrumentation during TKA can result in malalignment of several degrees. This error can be minimized by careful attention to the entry point of the IM instrumentation or by increasing the IM rod diameter and length used during primary TKA.

Aged↗

Bone densitometry: influence of prosthetic design and hydroxyapatite coating on regional adaptive bone remodelling.

The objective of this prospective study was to determine if bone densitometry can detect disparities in regional adaptive bone remodelling surrounding the cementless porous-coated femoral component of a hip prosthesis in two titanium alloy implants of different design . These prostheses were the S-ROM (n=69) and the Multilock (n=65). The Multilock implants consisted of two groups; 25 had a 50 micron layer of hydroxyapatite (HA) sprayed over the porous surface of the femoral component and the remaining 40 femoral components were not coated with HA. Densitometry was performed with dual energy X-ray absorptiometry (DXA) utilizing the LUNAR ORTHO software to analyse the seven Gruen zones. Bone mineral density measurements were obtained within a week of surgery as a baseline reference and at 6, 12, 24, 36 and 48 months thereafter. At 6 months there was significant mineral loss in all Gruen zones in the three prostheses. By 48 months there were differences in mineral loss between the three prostheses. In the zones adjacent to the porous surface, predominantly zones 1 and 7, the S-ROM exhibited 60% less mineral loss than the Multilock in zone 1, and there was no significant difference in zone 7. Compared to the Multilock-HA, the S-ROM lost 35% less mineral in zone 1, but the Multilock lost 70% less mineral than the S-ROM in zone 7. The Multilock-HA lost 37% and 75% less mineral than the Multilock in zones 1 and 7, respectively, i.e., hydroxyapatite coating tended to preserve bone stalk. Using the Gruen zone area measurements provided by the software, the S-ROM had significantly greater bone resorption in zone 7 at 24 months than either of the Multilocks, which did not differ from each other. In conclusion, DXA has shown differences in periprosthetic adaptive bone remodelling between implants of different design and composition as a function of time.

Absorptiometry, Photon↗

Tissue response to porous tantalum acetabular cups: a canine model.

This study evaluated the osseous tissue response to a noncemented metal-backed acetabular component made of a new porous tantalum biomaterial. Eleven dogs with bilateral total hip arthroplasties (22 acetabular implants) were studied for a period of 6 months. Thin section histology, high-resolution radiography, and backscattered scanning electron microscopy revealed that all 22 implants had stable bone-implant interfaces. Regions of bone ingrowth were present in all histologic sections. The depth of bone ingrowth varied from 0.2 mm to the maximal limit of 2 mm. Analyzing contiguous regions of interest across the full bone-implant interface, the mean bone ingrowth for all sections was 16.8% +/- 5.7%. In the peripheral regions of the cup where bone-implant contact was most consistent, bone ingrowth averaged 25.1% +/- 10.1%. The data indicate that the porous tantalum material is effective for biologic fixation in the dog and may provide a suitable alternative to other porous materials used in acetabular cup design.

Acetabulum↗

Temporal changes of periprosthetic bone density in patients with a modular noncemented femoral prosthesis.

Bone mineral density changes surrounding a porous-coated proximal modular sleeved hip prosthesis were determined as a function of time over a 24-month period. The periprosthetic bone regions were defined by the 7 Gruen zones. Measurements were obtained with a dual-energy x-ray densitometer using a dedicated software program. Inclusion criteria required that the patients had primary implants, were asymptomatic with Harris hip scores of > or =95 for the duration of the study, and showed no radiographic evidence of loosening. The protocol specified that bone measurements be obtained within 1 week after surgery as a baseline reference and at 3, 6, 9, 12, 18, and 24 months thereafter. A total of 111 consecutive patients were enrolled in this ongoing prospective study, of whom 52 had 4 or more measurements after the initial baseline determination for statistical analysis. At 3 months, all zones showed a significant decrease in bone mineral density relative to the baseline measurements, and their mean loss ranged from 6.5% to 11.2%. By 24 months, mineral losses relative to baseline varied from 0 to 11% for Gruen zones 1 to 6. Relative to the 3-month levels, there was no significant change in zones 1, 4, and 6; a significant improvement in zones 3 and 5; and a small but significant loss in zone 2 at 24 months. Gruen zone 7, the medial femoral neck cortex, differed in that it was the site of greatest bone mineral loss, attaining a mean of 20.2% at 24 months. It was found that the amount of periprosthetic mineral loss at 12 months was independent of the initial baseline reference bone mineral levels. Results of this study show the normal temporal bone mineral changes surrounding a proximally modular porouscoated femoral implant. The pattern of change demonstrated may be peculiar to the prosthesis used in this study because it might differ in implants of different design and material composition.

Absorptiometry, Photon↗

The osseous response to corundum blasted implant surfaces in a canine hip model.

The purpose of this study was to examine the radiographic and histologic response to corundum blasted implant surfaces of varying roughness in a canine total hip arthroplasty model. Three types of tapered femoral implants were made from titanium alloy and were identical in every respect except surface finish. The entire surface of the femoral implant had a 2.9-, 4.2-, or 6.7-micron average surface roughness (Ra) from blasting with 60-, 24-, or 16-grit corundum particles, respectively. Twenty-two stems in 11 dogs were evaluated at 6 months. Twenty-one of the stems showed osseointegration, whereas in one stem a fibrous interface developed. Abundant new periimplant bone formation occurred, particularly within the intramedullary canal where trabeculae spanned implant to endosteal cortex gaps as large as 5 mm. Bone apposition with the 60-, 24-, and 16-grit stems averaged 31.7%, 32%, and 27.9%, respectively; the differences were not statistically significant. However, the pattern of new bone formation was different in that the average length of each region of bone apposition for the 60- and 24-grit surfaces was 50% greater than that for the coarser 16-grit surface. The observations of this study indicate that because of their highly osteoconductive nature, corundum blasted surfaces represent an important and valuable technology for the design of noncemented implants.

Aluminum Oxide↗

The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants.

The implication of polyethylene wear particles as the dominant cause of periprosthetic osteolysis has created a resurgence of interest in metal-on-metal implants for total hip arthroplasty because of their potential for improved wear performance. Twenty-two cobalt chromium molybdenum metal-on-metal implants were custom-manufactured and tested in a hip simulator. Accelerated wear occurred within the first million cycles followed by a marked decrease in wear rate to low steady-state values. The volumetric wear at 3 million cycles was very small, ranging from 0.15 to 2.56 mm3 for all implants tested. Larger head-cup clearance and increased surface roughness were associated with increased wear. Independent effects on wear of material processing (wrought, cast) and carbon content were not identified. Implant wear decreased with increasing lambda ratio, a parameter used to relate lubricant film thickness to surface roughness, suggesting some degree of fluid film lubrication during testing. This study provided important insight into the design and engineering parameters that affect the wear behavior of metal-on-metal hip implants and indicated that high quality manufacturing can reproducibly lead to very low wear.

Analysis of Variance↗