Search PubMedSearch

Biomedical subjects

J D Andrade

Publications and source records attributed to J D Andrade.

At least 19 recordsLinked to original sources

Interaction of plasma proteins with heparinized gel particles studied by high-resolution two-dimensional gel electrophoresis.

In order to further the understanding of protein-surface interactions in the coagulation system, we have chosen to study plasma protein adsorption onto heparin-immobilized surfaces. Heparin-binding proteins are abundant in plasma: a search of amino acid sequences revealed that many plasma proteins have possible heparin binding sites. Plasma protein adsorption to the heparinized surfaces is monitored by a novel technique in which the solution depletion of proteins is analytically determined using quantitative two-dimensional polyacrylamide gel electrophoresis (2-D PAGE). This method enables simultaneous, quantitative detection of the majority of plasma proteins before, during, and after their adsorption onto high surface area adsorbents. Using computerized densitometry of silver-stained 2-D PAGE gels, the amount of each protein can be determined from the integrated optical density of each protein "spot." Kinetics of adsorption and adsorption isotherms of four important heparin binding proteins, antithrombin III (ATIII), complement factor C3 (C3), apolipoprotein AI (Apo-AI) and apolipoprotein AIV (Apo-AIV) are reported in this paper. From the adsorption isotherms, the apparent binding constants of each protein-immobilized heparin complex, Ka, were calculated. The surface binding constants were of the same order of magnitude as the respective solution binding constants in the literature. The surface binding constants followed the same order as the respective solution binding constants: Ka (ATIII) greater than Ka (Apo-AIV) greater than Ka (C3) greater than Ka (Apo-AI), indicating that protein binding to the immobilized heparin used is not essentially different from solution binding.

Adsorption

Vroman effects, techniques, and philosophies.

Leo Vroman's work on blood-materials interaction over the years has motivated and influenced much of our work in this field. Here we show how most of our studies on proteins at interfaces can be traced to Vroman's ideas presented in Blood over 25 years ago. Specifically, we briefly discuss simple proteins at simple interfaces, complex interfaces, complex proteins at interfaces, multi-parameter phenomena, and scientific communication and education.

Biocompatible Materials

Surface properties of copolymers of alkyl methacrylates with methoxy (polyethylene oxide) methacrylates and their application as protein-resistant coatings.

New polymeric surfactants, copolymers of alkyl methacrylates with methoxy (polyethylene oxide) methacrylates, were synthesized and characterized by gel permeation chromatography. They were studied as possible means to produce polyethylene oxide-rich surfaces by a simple coating treatment on common hydrophobic medical materials. They were further studied as cleaners for the removal of proteins preadsorbed on hydrophobic surfaces. The surface properties of the copolymers such as the adsorption properties of the copolymer on a hydrophobic surface, low density polyethylene, the protein-resistant character of the prepared polyethylene oxide surfaces and the effectiveness of the copolymers for removal of proteins pre-adsorbed on the surface, were investigated by X-ray photoelectron spectroscopy and by using 125I-labelled copolymers and 125I-labelled proteins. The surface properties of the synthesized copolymers were compared with those of commercially available polyethylene oxide containing block copolymer surfactants.

Adsorption

Spatially resolved detection of antibody-antigen reaction on solid/liquid interface using total internal reflection excited antigen fluorescence and charge-coupled device detection.

Spatially-resolved detection of antibody-antigen reactions at the solid/liquid interface was investigated by total internal reflection excited fluorescence from large area flat surfaces. Anti-HSA immunoglobulin G (IgG) antibody was immobilized at four spatially distinct spots. Binding of fluorescein-labeled human serum albumin (HSA) from the solution to immobilized antibody was detected by a cooled charge-coupled device (CCD) as a charge in the fluorescence intensity. A two-dimensional representation of the fluorescence was obtained during the binding reaction time of 25 mins. The contributions from bound and free antigen to the total signal were evaluated. The influence of the scattered excitation light and the normalization of fluorescence signal with respect to the two-dimensional incident light intensity distribution are discussed.

Antigen-Antibody Reactions

The influence of adsorption of native and modified antibodies on their activity.

Immobilization of biomolecules to solid phase materials has been widely used in many areas (e.g., purification, analytical chemistry, and catalysis). The interfacial properties of immobilized antibodies on pretreated silica and hydrogel surfaces were explored by comparing native and modified antibodies with respect to their surface activity. The antibody was modified by exposing it to a low pH solution prior to immobilization. Both physical adsorption and covalent immobilization methods were studied. It was found that the surface activity of the modified antibody is higher than that of the native antibody on two silica surfaces. The results of this study demonstrate that the adsorption properties of the antibodies play an important role in their covalent immobilization on certain types of solid supports.

Adsorption

Protein-resistant surfaces prepared by PEO-containing block copolymer surfactants.

Polyethylene oxide(PEO)-containing nonionic polymeric surfactants were studied as a possible means to produce PEO-rich surfaces by a simple coating treatment of a common hydrophobic medical material--polyethylene. Surface tension and adsorption properties of PEO/polypropylene oxide(PPO) and PEO/polybutylene oxide(PBO) block copolymer surfactants on a hydrophobic surface (low density polyethylene, LDPE) were investigated, using the Wilhelmy plate surface tension technique and x-ray photoelectron spectroscopy(XPS). The protein resistance of the surfactant-treated surfaces was evaluated by XPS and 125I-labeled proteins. The data presented indicate that adsorption of the surfactants on LDPE is dependent on the molecular geometry of the surfactants. Adsorption of human albumin was significantly decreased on the surfactant-treated LDPE surfaces, as compared with the untreated surface. Surfactants suitable for the preparation of PEO-rich surfaces and possible mechanisms for their protein resistance are discussed.

Adsorption

On-line sensors for coagulation proteins: concept and progress report.

The assessment of blood damage and of the activation of the coagulation, complement and/or inflammatory systems by cardiovascular and extracorporeal devices is difficult at best. Immunoassay methods are now available for the measurement of many of the proteins, enzymes and peptides involved in coagulation, thrombosis, complement and inflammation. We present a long-range project and plan to develop an array of remote, on-line, semicontinuous immunosensors for selected coagulation proteins, based on fluoroimmunoassay principles. The free/bound separation step is performed optically. Excitation of fluorescence is performed via an evanescent wave produced by total internal reflection and waveguide optics. Fluorescence emission is collected only in the near field. Means to deliver fluorescently-labelled reagent and to modify the antigen-antibody binding constant are presented and discussed. The results of non-specific binding, plasma-blood fluorescence, and blood compatibility are also discussed.

Biocompatible Materials

Scanning tunnelling microscopic images of amino acids.

We present images of amino acids adsorbed on highly orientated pyrolytic graphite (HOPG) obtained with the scanning tunnelling microscope (STM) in air. Individual molecules can be observed although the majority of adsorbates appear to form clusters. In the case of leucine, methionine, and tryptophan, two molecules often associate together to form a dimer. Single or dimer glycine molecules were not seen, but a cluster of a number of them was observed. The various adsorbed states may be related to the different interactions between the amino acids and the graphite surface. The mechanism of image formation of the amino acids is probably related to charge transfer mechanisms.

Adsorption

Adsorption of low density lipoproteins onto selected biomedical polymers.

This study examines the interaction of human low density lipoprotein (LDL) with a select group of biomedical polymers. The adsorption characteristics of LDL on cured filler-free poly(dimethyl Siloxane) (C-PDMS), Biomer, Cardiomat 610, Kraton 1650, poly(hydroxyethyl methacrylate) (PHEMA) and glass are presented. Adsorption of LDL to charged hydrophilic glass control surfaces occurred rapidly, reaching plateau concentrations within one minute (0.19 +/- 0.01 ug/cm2). Adsorption of LDL to polymer surfaces appeared to be dependent upon both the polymer hydrophobicity (or apolar nature), and flexibility (or dynamic nature) at the interface. Increased surface concentrations were observed for Biomer (0.32 +/- 0.01 ug/cm2) as well as other polymers which exhibited both hydrophobic and elastomeric properties. Temperature changes between 25 degrees C and 37 degrees C were found to significantly influence the surface concentration of LDL on Biomer (0.16 +/- 0.01 ug/cm2 at 25 degrees C versus 0.32 +/- 0.01 ug/cm2 at 37 degrees C). A lipid core phase transition at 36 degrees C was believed to be responsible for the temperature influence. Preliminary competitive adsorption studies of LDL with albumin (HSA) and serum on silicone surfaces suggests that LDL adsorption occurred rapidly and preferentially (0.25 +/- 0.01 ug/cm2 for LDL alone; 0.33 +/- 0.01 ug/cm2 for LDL + HSA; 0.15 +/- 0.01 ug/cm2 LDL + serum). Preliminary studies on the role of LDL in calcification were not conclusive. It can be concluded that LDL adsorption is dependent upon polymer hydrophobicity, flexibility and temperature. Competitive adsorption experiments suggests that LDL may have a substantial influence on protein adsorption.

Adsorption

Plasma protein adsorption: the big twelve.

We have discussed the general principles of protein adsorption at solid-liquid interfaces from single component and multicomponent solutions, based on qualitative kinetic models that include mass transport considerations, initial interaction energies, surface-dependent conformational changes, and possible desorption processes. We have surveyed plasma protein components greater than one milligram per milliliter in concentration, which we call "The Big Twelve." We considered their size, concentration, diffusion coefficient, structure and function, and methods of estimating their "surface denaturability" by using bulk solution measures of denaturation and conformational change. We have suggested that the role of the carbohydrate moieties in plasma proteins may have some bearing on their adsorption properties. We further suggest that lipoproteins, because of their lipid phase transition and conformational lability at body temperature, may tend to dominate the adsorption process, particularly on mobile elastomeric polymer surfaces. We suggest that detailed consideration of the structure and characteristics of each of the proteins involved is necessary in order to begin to understand plasma adsorption processes. Detailed characterization and understanding of the solid surface in the aqueous and protein environments are also required.

Adsorption

Human haptoglobin adsorption by a total internal reflection fluorescence method.

Haptoglobin (Hp) is one of the major protein constituents of plasma. Three different forms are found in the population. The 1-1 and 2-2 forms adsorb similarly onto hydrophobic silica [treated with dimethyl dichlorosilane (DDS)] and onto clean silica, although the affinities on the silica surface are lower at 60 minutes contact time. The two forms desorb differently from silica, but desorb similarly from DDS-silica. Adsorption is less reversible on the hydrophobic surface. Due to its adsorbtion tendencies and its high concentration in plasma, the adsorption of Hp may be important in blood interaction at solid-liquid interfaces.

Adsorption

Immunochemical detection by specific antibody to thrombin of prothrombin conformational changes upon adsorption to artificial surfaces.

Polyclonal antihuman alpha-thrombin antibodies produced in rabbits reacted minimally (less than 0.05%) in solution with human prothrombin. However, when prothrombin was adsorbed to artificial surfaces such as polyvinyl chloride (PVC), the cross-reactivity of surface-bound prothrombin with antibody IgG to thrombin (greater than 95% purity) was shown to be significantly enhanced. On PVC, the molar ratios of antibody IgG to thrombin/prothrombin approached the same level as that of antibody IgG to thrombin/thrombin when thrombin was adsorbed to the same material. The analyses of antigen-antibodies interaction, in solution with a direct binding assay by immune precipitation at high-speed centrifugation (160,000 g, 30 min), and on solid-phase PVC, were accomplished by use of double-labeling technique, i.e., 131I-thrombin (or 131I-prothrombin) and 125I-antibody IgG to thrombin. The results appear to suggest that prothrombin adsorption to PVC has resulted in some molecular conformational changes so that immunologically the adsorbed prothrombin resembles that of adsorbed thrombin on the same PVC surface.

Adsorption

Oxy- and deoxyhaemoglobin adsorption onto glass and polymer surfaces.

The adsorption of deoxyhaemoglobin (deoxyHb) and oxyhaemoglobin (oxyHb) was determined on clean glass, n-pentyl triethoxysilane (NPS)-treated glass, polystyrene (PS), and a polyetherurethane (PEU). The adsorbed amounts range from 0.1 to 0.6 micrograms/cm2 for oxyHb and from 0.3 to 0.7 micrograms/cm2 for deoxyHb. DeoxyHb adsorbs onto all these surfaces more than oxyHb. The more hydrophobic the surface, the more adsorption of both deoxy and oxyHb forms. These results suggest the oxyHb and deoxyHb interact differently with the surfaces studied. It is likely that the surface hydrophobicity of Hb plays a major role in Hb adsorption onto surfaces; the deoxyHb surface is more hydrophobic than the oxyHb surface. The binding sites for Hb adsorption may include the clefts between alpha 1, beta 1. A surface-induced dimerization mechanism is proposed to explain the adsorption of oxyHb.

Adsorption

Surface modification and evaluation of some commonly used catheter materials. I. Surface properties.

Double catheter systems consisting of a stiff outer catheter and a flexible, buoyant, flow-directed, inner catheter which is often balloon-tipped have been employed with increasing frequency recently in both therapeutic and diagnostic procedures. Their use, however, has been restricted because of the excessive friction generated between the two catheters. In an attempt to decrease friction between polymers commonly used as catheter materials, oxidation of polyethylene, fluorinated ethylene-propylene copolymer, poly(vinyl chloride), silicone rubber, and polystyrene surfaces was induced by exposing the polymers to radio frequency glow discharge (RFGD) in a helium environment. All polymers were surface characterized utilizing x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and contact angle measurements before and after oxidation. This article describes the materials and methods used to fabricate and characterize the polymer surfaces and the results of the characterization. The results indicate that increases in oxygen concentration at the surface of the polymers and decreases in air-water contact angles occur with increased RFGD exposure time. Plateau values were usually obtained after 5-30 s exposure time, yet no apparent changes in surface topography were noted by scanning electron microscopy. The hydrophilic surfaces produced were stable for up to three months storage time in air.

Biocompatible Materials

Surface modification and characterization of some commonly used catheter materials. II. Friction characterization.

The effects of the modification of polystyrene (PS), polyethylene (PE), poly(vinyl chloride) (PVC), silicone rubber (SR), and fluorinated ethylene propylene (FEP) copolymer by radio frequency glow discharge in a helium environment were presented in part I. The hydrated polymer surfaces were characterized by XPS, SEM, visual microscopy, and by contact angle measurements. In general, exposure of the polymers to RFGD produced an oxidized hydrophilic surface, yet the roughness of the surface was unaltered by the relatively mild plasma conditions used. In this article, the frictional behavior of oxidized and unoxidized SR, PE, and FEP in distilled water, isotonic saline, and blood plasma environments is examined experimentally. The results are discussed in relation to the properties generally believed to affect frictional phenomena and to the surface properties as determined in part I. Results indicate that RFGD-treated SR generates less friction than untreated SR when dragged across all untreated and treated polymer surfaces, whether the medium is distilled water or an isotonic saline solution. Friction is consistently lower in a blood plasma medium between all surfaces investigated, most probably because of the presence of adsorbed proteins at the polymer interfaces.

Biocompatible Materials

Minimizing the aggregation of neutral insulin solutions.

Various solution additives affect the solubility and macroaggregation of insulin in buffered aqueous solutions at physiological pH. The solubility of insulin may be improved with the addition of small amounts of aspartic acid, glutamic acid, EDTA (ethylenediaminetetraacetic acid), lysine, Tris buffer, or bicarbonate buffer. In addition, the propensity of dissolved insulin to reaggregate and precipitate may be inhibited by such additives. Buffered physiological (pH 7.4) saline solutions containing 0.001-0.003 M lysine in the presence of 0.005 M EDTA or 0.01 M lysine in the absence of EDTA improve insulin solubility and are effective in minimizing aggregation. Solutions thus prepared may be suitable for application in intravenous insulin infusion devices and may be useful commercial insulin preparations.

Chemical Precipitation

Blood-materials interactions: the minimum interfacial free energy and the optimum polar/apolar ratio hypotheses.

Numerous hypotheses exist to explain observed blood-materials interactions. It is the purpose of this article to test two popular hypotheses, namely, the minimum interfacial free energy hypothesis and the optimum polar/apolar ratio hypothesis. Methacrylate polymers and copolymers were characterized using the captive bubble underwater contact angle method; bulk water content was determined by gravimetric methods; streaming potential measurements were made; and surface roughness and possible particulate contamination were evaluated by reflected light microscopy. In vitro blood tests include whole blood clotting time measurements on polymer-coated tubes; centrifugal force platelet adhesion on polymer-coated coverslips; and a measure of the partial thromboplastin time, Russell's viper venom time (Stypven time), and the prothrombin time of native whole blood exposed to polymer-coated microscope slides. Results suggest that platelet adhesion correlates in the opposite direction of whole blood clotting time and partial thromboplastin time, emphasizing the need for a multiparameter approach to blood-materials testing. Based on these tests the minimum interfacial free energy hypothesis is not supported. In fact, the data suggest the opposite to be true. It is apparent that platelet adhesion can be a misleading indicator of blood compatibility. Neither hypothesis can explain the apparent conflict between the platelet adhesion data and the coagulation time data.

Animals