Search PubMed⌕ Search

Biomedical subjects

J Conway

Publications and source records attributed to J Conway.

At least 55 records · Page 3Linked to original sources

Measurement of the top quark p(T) distribution.

We have measured the p(T) distribution of top quarks that are pair produced in pp collisions at sqrt[s] = 1.8 TeV using a sample of tt decays in which we observe a single high- p(T) charged lepton, a neutrino, and four or more jets. We use a likelihood technique that corrects for the experimental bias introduced due to event reconstruction and detector resolution effects. The observed distribution is consistent with the standard model prediction. We use these data to place limits on the production of high- p(T) top quarks suggested in some models of anomalous top quark pair production.

Journal Article↗

Search for neutral supersymmetric Higgs bosons in pp collisions at sqrt[s] = 1.8TeV.

We present the results of a search for neutral Higgs bosons produced in association with b quarks in pp-->bb(phi)-->bbb final states with 91+/-7 pb(-1) of pp collisions at sqrt[s] = 1.8 TeV recorded by the Collider Detector at Fermilab. We find no evidence of such a signal and the data are interpreted in the context of the neutral Higgs sector of the minimal supersymmetric extension of the standard model. With basic parameter choices for the supersymmetric scale and the stop-quark mixing, we derive 95% C.L. lower mass limits for neutral Higgs bosons for tan(beta) values in excess of 35.

Journal Article↗

Production of chi(c1) and chi(c2) in pp collisions at sqrt[S] = 1.8 TeV.

We have measured the ratio of prompt production rates of the charmonium states chi(c1) and chi(c2) in 110 pb(-1) of pp collisions at sqrt[s] = 1.8 TeV. The photon from their decay into J/psi(gamma) is reconstructed through conversion into e+e- pairs. The energy resolution this technique provides makes the resolution of the two states possible. We find the ratio of production cross sections sigma(chi(c2))/sigma(chi(c1)) = 0.96+/-0.27(stat)+/-0.11(syst) for events with pT(J/psi) > 4.0 GeV/c, /eta(J/psi)/ < 0.6, and pT(gamma) > 1.0 GeV/c.

Journal Article↗

First measurement of the ratio B(t --> Wb)/B(t --> Wq) and associated limit on the Cabibbo-Kobayashi-Maskawa element /V(tb)/.

We present the first measurement of the ratio of branching fractions R identical withB(t-->Wb)/B(t-->Wq) from p_p collisions at sqrt[s] = 1.8 TeV. The data set corresponds to 109 pb(-1) of data recorded by the Collider Detector at Fermilab during the 1992-95 Tevatron run. We measure R = 0.94(+0.31)(-0.24)(stat+syst) or R>0.61 (0.56) at 90% (95)% C.L., in agreement with the standard model predictions. This measurement yields a limit on the Cabibbo-Kobayashi-Maskawa quark mixing matrix element /V(tb)/ under the assumption of three generations and unitarity.

Journal Article↗

The impact of virtual simulation in palliative radiotherapy for non-small-cell lung cancer.

BACKGROUND AND PURPOSE: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation. METHODS: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage. RESULTS: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%. CONCLUSIONS: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.

Carcinoma, Non-Small-Cell Lung↗

Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniques.

BACKGROUND AND PURPOSE: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution. MATERIALS AND METHODS: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stem, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated. RESULTS: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170 degrees from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation. CONCLUSIONS: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions.

Humans↗

Stability after medial collateral ligament release in total knee arthroplasty.

Six knees from cadavers were tested for change in stability after release of the medial collateral ligament with posterior cruciate-retaining and substituting total knee replacements. Load deformation curves of the joint were recorded in full extension and 30 degrees, 60 degrees, and 90 degrees flexion under a 10 N-m varus and valgus torque, 1.5 N-m internal and external rotational torque, and a 35 N anterior and posterior force to test stability in each knee. The intact specimen and posterior cruciate ligament-retaining total joint replacement were tested for baseline comparisons. The superficial medial collateral ligament was released, followed by release of the posterior cruciate ligament. The knee then was converted to a posterior-stabilized implant. After medial collateral ligament release, valgus laxity was statistically significantly greater at 30 degrees, 60 degrees, and 90 degrees flexion after posterior cruciate ligament sacrifice than it was when the posterior cruciate ligament was retained. The posterior-stabilizing post added little to varus and valgus stability. Small, but significant, differences were seen in internal and external rotation before and after posterior cruciate ligament sacrifice. The posterior-stabilized total knee arthroplasty was even more rotationally constrained in full extension than the knee with intact medial collateral ligament and posterior cruciate ligament.

Arthroplasty, Replacement, Knee↗

The effect of the addition of proteases and glucanases during yeast autolysis on the production and properties of yeast extracts.

Yeast extracts (YE) were produced with the addition of proteases or glucanases during bakers' yeast (Saccharomyces cerevisiae) autolysis. Chemical composition, physical properties, and biological value of the YE were examined. Proteases had the highest impact on the turbidity and filterability of YE. All 11 proteases and two glucanases increased YE yields (% yeast solids solubilized) obtained from heated (80 degrees C/15 min) bakers' yeast creams (BYC). However, when proteases were added to native (unheated) BYC during autolysis, few increased YE yields, with papain being the most effective. The increased yields were generally related to increased levels of total nitrogen (TN) and alpha-amino nitrogen (alpha-AN) in the YE. Media were supplemented with the various yeast extracts, and the highest growth rates (mumax) and biomass values (ODmax) of Lactobacillus acidophilus were noted. The best growth was obtained with YE produced with native BYC treated with a fungal protease, and results of this study show that some enzymes could be used to produce improved YE for microbiological media.

Biomass↗

Astronomical constraints on the cosmic evolution of the fine structure constant and possible quantum dimensions.

We present measurements of absorption by the 21 cm hyperfine transition of neutral hydrogen toward radio sources at substantial look-back times. These data are used in combination with observations of rotational transitions of common interstellar molecules to set limits on the evolution of the fine structure constant: alpha/ alpha<3.5x10(-15) yr(-1), to a look-back time of 4.8 Gyr. In the context of string theory, the limit on the secular evolution of the scale factor of the compact dimensions, R, is &Rdot/ R<10(-15) yr(-1). Including terrestrial and other astronomical measurements places 2sigma limits on slow oscillations of R from the present to the epoch of cosmic nucleosynthesis, just seconds after the big bang, of DeltaR /R<10(-5).

Journal Article↗

Measurement of J/psi and psi(2S) polarization in pp collisions at sqrt[s] = 1.8 TeV.

We have measured the polarization of J/psi and psi(2S) mesons produced in pp collisions at sqrt[s] = 1.8 TeV, using data collected at the Collider Detector at Fermilab during 1992-1995. The polarization of promptly produced J/psi [psi(2S)] mesons is isolated from those produced in B-hadron decay, and measured over the kinematic range 4 [5.5]<P(T)<20 GeV/c and |y|<0.6. For P(T) greater than or approximately equal 12 GeV/c we do not observe significant polarization in the prompt component.

Journal Article↗

Search for scalar top and scalar bottom quarks in pp collisions at square root s=1.8 TeV.

We have searched for direct pair production of scalar top and scalar bottom quarks in 88 pb-1 of pp collisions at sqrt[s]=1.8 TeV with the CDF detector. We looked for events with a pair of heavy flavor jets and missing energy, consistent with scalar top (bottom) quark decays to a charm (bottom) quark and a neutralino. The numbers of events that pass our selections show no significant deviation from standard model expectations. We compare our results to the next-to-leading order scalar quark production cross sections to exclude regions in scalar quark-neutralino mass parameter space.

Journal Article↗

Search for a W' boson via the decay mode W'-->munumu in 1.8 TeV pp collisions.

We report the results of a search for a W' boson produced in pp collisions at a center-of-mass energy of 1.8 TeV using a 107 pb-1 data sample recorded by the Collider Detector at Fermilab. We consider the decay channel W'-->&munumu and search for anomalous production of high transverse mass munumu lepton pairs. We observe no excess of events above background and set limits on the rate of W' boson production and decay relative to standard model W boson production and decay using a fit of the transverse mass distribution observed. If we assume standard model strength couplings of the W' boson to quark and lepton pairs, we exclude a W' boson with invariant mass less than 660 GeV/c2 at 95% confidence level.

Journal Article↗

Automatic image registration of diagnostic and radiotherapy treatment planning CT head images.

PURPOSE: Accurate image registration is an essential step to integrate information from diagnostic and radiotherapy treatment planning (RTP) CT images. In this paper a fully automatic algorithm is presented to quickly register such diagnostic and RTP CT head scans. METHODS AND MATERIALS: The registration algorithm, which regards one image as the moved version of the other, was applied to seven clinically obtained diagnostic and RTP CT data set pairs. During the RTP scan patients were in treatment position and wearing mold masks. Hence, patient position differed strongly in both image sets. Registrations were inspected visually and compared with results obtained minimizing the sum-of-square difference. RESULTS: Registrations were accurate upon visual inspection. Differences between the two algorithms were at subvoxel level. All cases were successfully registered, using several different starting points. Registration calculations took 1-2 minutes. Minimization of the sum-of-square difference took 1-1.5 hours. CONCLUSIONS: The results show that a fast and accurate image registration is achieved without prior segmentation or feature extraction and that the algorithm is robust, which makes it clinically applicable.

Algorithms↗

Measurement of blood pressure using the auscultatory and oscillometric methods in the same cuff deflation: validation and field trial of the A&D TM2421 monitor.

We have evaluated under laboratory validation conditions and in an extensive field trial the behaviour of an ambulatory monitoring device that is capable of recording both by the Korotkoff-sound and oscillometric methods in a single cuff deflation (TM2421: A&D Co, Tokyo, Japan). The effects of subject age and blood pressure (BP) level on the accuracy and field reliability of the two methods implemented in the device have been determined. In the validation phase, automatic BP measurements were compared with readings by two trained observers in 96 subjects, and the results compared with the AAMI criteria for automatic BP monitors. In the field trial phase, the performances of Korotkoff-sound and oscillometric methods over a 24-h period of ambulatory BP monitoring were compared in 515 subjects, with analysis of the agreement between the two methods in patients where both provided satisfactory recordings. In the validation phase, the Korotkoff-sound method gave satisfactory results for both systolic and diastolic BP, but the oscillometric technique narrowly failed to meet the AAMI criteria for the measurement of either systolic or diastolic BP. In the field trial, the K-sound method failed to record BP accurately in 12% of subjects whereas the oscillometric method was successful in all of these. Where both methods provided technically adequate records, agreement between mean values for each method was close. In 18% of patients, the availability of the oscillometric measurement as a 'back-up' method for the K-sound method significantly improved the number of available measurements in the monitoring period, which should result in improved accuracy and reproducibility of the ambulatory mean values.

Adult↗

Applied behavior management and acquired brain injury: approaches and assessment.

Individuals who have acquired brain injury (ABI) may express themselves through the use of challenging behaviors, such as aggression, withdrawal, disinhibition, and self-destructive behaviors. This article describes the effectiveness of behavior interventions derived from the assessment of behavior in a community-based setting. The premise is that behavior, no matter how difficult, has function, purpose, and meaning for the individual. A therapeutic model of behavior assessment is presented that bases its strength on behavior assessment and well-trained staff. A well-formulated behavior management plan is developed, reinforcing alternative behaviors teaching skills, and reducing unwanted behaviors. Through the use of data collection methods, the treatment team identifies variables related to unwanted behavior and outcomes of consequences as they relate to the behavior. Illustrated through a case study, the behavioral treatment model is defined through behavior identification, initial assessments, treatment approaches, and tracking outcomes.

Aggression↗

Effect of ultrafiltration of yeast extracts on their ability to promote lactic acid bacteria growth.

Five yeast extracts (YE) were fractionated by ultrafiltration (UF) with 1, 3, and 10 kDa molecular weight cutoff membranes, concentrated by freeze-drying, and the resulting powders of yeast extract filtrates (YEF) were evaluated for their growth-promoting properties on nine cultures of lactic acid bacteria (LAB). There was an increase in alpha-amino nitrogen content of the YEF powders as the pore size of the UF membranes used to filter the YE solutions decreased. The source of YE had a much greater effect than UF on the growth of LAB. This was also the case for the YEF contents in total and alpha-amino nitrogen. Growth curves of the LAB showed that maximum growth rate (mumax) data were on average 30% higher with bakers' YE than with brewers' YE, while maximum optical density (ODmax) values were on average 16% higher with bakers' YE. This could be related to the higher nitrogen content of the bakers' YE used in this study. Modification by UF of the YE had no significant influence on the growth of 4 of the 9 LAB strains. The three strains of Lactobacillus casei were negatively influenced by UF, as they did not grow as well in the media containing the YEF obtained after filtering with 1 and 3 kDa membranes. On a total solids basis, the 2.5 x retentates from the 10 kDa membrane gave, on average, 4% lower mumax and 5% lower ODmax values as compared to cultures where the corresponding YEF was used as medium supplement. This could also be partially related to the different nitrogen contents of the filtrates and retentates.

Culture Media↗