Search PubMed⌕ Search

Biomedical subjects

J Cleland

Publications and source records attributed to J Cleland.

At least 91 records · Page 5Linked to original sources

Mitral annuloplasty in endomyocardial fibrosis: an alternative to valve replacement.

The case of a patient with left ventricular endomyocardial fibrosis (EMF) causing severe mitral regurgitation is presented. Excision of the fibrotic tissue through the left atrium and mitral annuloplasty resulted in symptomatic relief and uncomplicated pregnancy. An X-linked congenital dermatological condition, Bloch-Sulzberger syndrome (incontinentia pigmenti), associated with chronic eosinophilia, was also present. This occurrence with EMF has not previously been reported. Atrioventricular valve reconstruction is a feasible alternative to valve replacement in EMF.

Adult↗

Discrete subaortic stenosis.

Data concerning 17 consecutive patients with discrete subaortic stenosis are recorded. Twelve patients underwent operative resection of the obstructing lesion. Of these all except one were symptomatic and all had electrocardiographic evidence of left ventricular hypertrophy or left ventricular hypertrophy with strain. They had a peak resting systolic left ventricular outflow tract gradient of greater than 50 mmHg as predicted from the combined cuff measurement of systolic blood pressure and the echocardiographically estimated left ventricular systolic pressure and/or as determined by cardiac catheterisation. The outflow tract gradient as predicted from M-mode echocardiography and peak systolic pressure showed close correlation with that measured at cardiac catheterisation or operation. During the postoperative follow-up from one month to 11 years, of 11 patients, one patient required a further operation for recurrence of the obstruction four years after the initial operation. All patients are now asymptomatic. Five patients have not had an operation. The left ventricular outflow tract gradient as assessed at the time of cardiac catheterisation was greater than 50 mmHg. One patient has been lost to follow-up. The remaining four have been followed from four to eight years and have remained asymptomatic and the electrocardiograms have remained unchanged. Careful follow-up of all patients is essential with continuing clinical assessment, electrocardiograms, M-mode and two-dimensional echocardiograms, and if necessary cardiac catheterisation. Prophylaxis against bacterial endocarditis is also essential.

Adolescent↗

Aortic valve replacement for severe aortic regurgitation caused by idiopathic giant cell aortitis.

Giant cell aoritis occurred in a 25-year-old woman, with absent pulses in the left arm and severe aortic regurgitation from dilatation of the valvar annulus. The aortic valve was replaced by a Starr-Edwards prosthesis, and the patient was treated with steroids. Five years later, she continues asymptomatic and haemodynamically stable. The left brachial and radial pulses have returned.

Adult↗

Comparative analysis of isolated aortic valve replacement with fascia lata and homograft valves.

Thirty-eight consecutive patients who underwent isolated replacement of the aortic valve with fascia lata in 1970 were compared with a similar series of patients undergoing homograft replacement of the aortic valve. These series were well matched in number, age sex of patients, symptomatology, valvular disease, electrocardiographic and roentegenographic changes, and preoperative cardiac catheterization data. The mean follow-up time was 73 months in the fascia lata series and 69.1 months in the homograft series, and all the post-operative survivors were reviewed. The early and long-term results were similar of the two series, and there was no statistical difference in the operative and late mortality, the incidence of early and late diastolic murmurs, valve failure necessitating valve replacement, infective endocarditis, thromboembolism, over-all survival, and survival with an intact valve. It is concluded that the long-term results of valve replacement using these two tissues, in the aortic position, are similar and there is little to choose between the two types of valves. If fascia lata, as we believe, is no longer acceptable as a satisafactory valve substitute, then homograft valves are not acceptable either.

Adolescent↗

Delayed non-mycotic false aneurysm of ascending aortic cannulation site.

Two cases of delayed non-mycotic false aneurysm arising from ascending aortic cannulation site, presenting one-and-a-hald years and seven years after cardiopulmonary bypass, are described. These two cases represent an incidence of 0.12% of this complication. Repair using profound hypothermia and circulatory arrest with femoral artery and femoral vein cannulation for cardiopulmonary bypass is recommended. The advantages and complications of aortic cannulation are discussed and recommendations to minimise the complications of cannulation are made. The clinical presentation and diagnosis of non-mycotic false aneurysms arising from the aortic cannulation site are described. In addition one delayed and two early cases of non-mycotic cannulation site false aneurysms previously published are analysed. Surgeons should be alert to the possibility of this complication in all patients who have had aortic cannulation for cardiopulmonary bypass even in the distant past. Unexpected symptoms such as constant anterior chest pain, dysphagia, hoarseness, and increasing widening of the superior mediastinum on the chest radiograph warrant prompt investigation.

Adult↗

The diagnosis of organic tricuspid valve disease.

Diagnostic features of organic tricuspid valve disease are discussed with emphasis on clinical features. Cardiac catheter data show considerable differences in assessment as do the chest radiographs. Measurement of the right atrial border from the vertebral edge is a reliable guide to diagnosis.

Adult↗

A universally applicable continuous suture technique for insertion of aortic valve prostheses.

In a series of 55 consecutive patients with both single- and multiple-valve disease and aortic aneurysm, the aortic valve was replaced using a continuous suture technique. The technique is applicable for both ball- and disc-valve prostheses. This method resulted in a marked reduction in cardiopulmonary bypass time with a very low incidence of perivalvular leak. It has major advantages over other continuous and interrupted suture techniques.

Aortic Valve↗

Plasma and tissue digoxin concentrations in patients undergoing cardiopulmonary bypass.

Plasma myocardial, and skeletal muscle digoxin concentrations were measured in 32 patients undergoing cardiopulmonary bypass who were on long-term treatment with digoxin. The patients were divided into 4 groups according to the daily digoxin dose and the interval between discontinuation of the drug and operation. Before bypass, the mean digoxin concentrations were 1.58 nmol/l (1.24 ng/ml) in plasma 65.2 nmol/kg (50.9 ng/g) in the atria, 121.4 nmol/kg (94.98 ng/g) in 11 papillary muscles, and 16.6 nmol/kg (13.0 ng/g) in skeletal muscle. Mean atrial digoxin concentrations were significantly lower tham mean papillary muscle concentrations in 11 patients. Ratios of plasma of myocardial or skeletal muscle digoxin concentrations were very variable. Generally digoxin concentrations were higher in patients on the larger digoxin dose and with the shorter discontinuation time before surgery. These differences attained significance only with plasma digoxin concentrations. There was a slight fall in plasma digoxin concentration during cardiopulmonary bypass but no significant differences were observed between plasma, atrial, or skeletal muscle digoxin concentrations before and at the end of bypass. No clear relation was seen between plasma or atrial digoxin concentrations and postoperative cardiotoxicity. Stopping digoxin 48 hours before operation appeared to account for pre- or post-bypass plasma digoxin concentrations of less than 1.0 nmol/l (0.8 ng/ml) in most of the instances encountered, whereas the 3 patients who developed pulsus bigeminus postoperatively had received 0.5 mg digoxin only 24 hours before operation.

Adult↗