J C Rosenwald

Publications and source records attributed to J C Rosenwald.

At least 19 recordsLinked to original sources

Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning.

PURPOSE: One of the most difficult steps of the three-dimensional conformal radiotherapy (3DCRT) is to define the clinical target volume (CTV) according to the degree of local microscopic extension (ME). In this study, we tried to quantify this ME in non-small-cell lung cancer (NSCLC). MATERIAL AND METHODS: Seventy NSCLC surgical resection specimens for which the border between tumor and adjacent lung parenchyma were examined on routine sections. This border was identified with the naked eye, outlined with a marker pen, and the value of the local ME outside of this border was measured with an eyepiece micrometer. The pattern of histologic spread was also determined. RESULTS: A total of 354 slides were examined, corresponding to 176 slides for adenocarcinoma (ADC) and 178 slides for squamous cell carcinoma (SCC). The mean value of ME was 2.69 mm for ADC and 1.48 mm for SCC (p = 0.01). The usual 5-mm margin covers 80% of the ME for ADC and 91% for SCC. To take into account 95% of the ME, a margin of 8 mm and 6 mm must be chosen for ADC and SCC, respectively. Aerogenous dissemination was the most frequent pattern observed for all groups, followed by lymphatic invasion for ADC and interstitial extension for SCC. CONCLUSION: The ME was different between ADC and SCC. The usual CTV margin of 5 mm appears inadequate to cover the ME for either group, and it must be increased to 8 mm and 6 mm for ADC and SCC, respectively, to cover 95% of the ME. This approach is obviously integrated into the overall 3DCRT procedure and with other margins.

Adenocarcinoma↗

AVS/express for the PC implementation of a 3D visualization module for radiotherapy.

Treatment planning systems (TPS) are nowadays of great help in cancer radiotherapy. Basically, they allow the pair physician/physicist to simulate the beams' irradiation effects on tumors as well as healthy tissues in terms of delivered radiation doses and finally to assess the validity of a beam setup. The state of the art in TPS leads to the following evidence concerning the future of such softwares: an access to a 3D visualization at each step of the design and verification of a plan has become necessary. Moreover, the fast increasing performances of personal computers (PC) will make possible in a near future the implementation at a lower cost of a complete 3D TPS. One of the keys of such an ambition is the compatibility between the implementation tools and the needs for power and flexibility. A first implementation on Open VMS of a simple 3D visualization for Institut Curie's TPS ISIS using Advanced Visual Systems' AVS 5 has been achieved. Their next generation tool, AVS/Express, seemed to meet the needs of a wide scale development. The use of AVS/Express working together with Microsoft Visual C++ in the implementation on Windows NT of a 3D visualization module is exposed.

Humans↗

Comparison of conformal radiation therapy techniques within the dynamic radiotherapy project 'Dynarad'.

The objective of the dynamic radiotherapy project 'Dynarad' within the European Community has been to compare and grade treatment techniques that are currently applied or being developed at the participating institutions. Cervical cancer was selected as the tumour site on the grounds that the involved organs at risk, mainly the rectum and the bladder, are very close to the tumour and partly located inside the internal target volume. In this work, a solid phantom simulating the pelvic anatomy was used by institutions in Belgium, France, Greece, Holland, Italy, Sweden and the United Kingdom. The results were evaluated using both biological and physical criteria. The main purpose of this parallel evaluation is to test the value of biological and physical evaluations in comparing treatment techniques. It is demonstrated that the biological objective functions allow a much higher conformality and a more clinically relevant scoring of the outcome. Often external beam treatment techniques have to be combined with intracavitary therapy to give clinically acceptable results. However, recent developments can reduce or even eliminate this need by delivering more conformal dose distributions using intensity modulated external dose delivery. In these cases the reliability of the patient set-up procedure becomes critical for the effectiveness of the treatment.

European Union↗

Dose calculation and verification of intensity modulation generated by dynamic multileaf collimators.

While the development of inverse planning tools for optimizing dose distributions has come to a level of maturity, intensity modulation has not yet been widely implemented in clinical use because of problems related to its practical delivery and a lack of verification tools and quality assurance (QA) procedures. One of the prerequisites is a dose calculation algorithm that achieves good accuracy. The purpose of this work was twofold. A primary-scatter separation dose model has been extended to account for intensity modulation generated by a dynamic multileaf collimator (MLC). Then the calculation procedures have been tested by comparison with carefully carried out experiments. Intensity modulation is being accounted for by means of a 2D (two-dimensional) matrix of correction factors that modifies the spatial fluence distribution, incident to the patient. The dose calculation for the corresponding open field is then affected by those correction factors. They are used in order to weight separately the primary and the scatter component of the dose at a given point. In order to verify that the calculated dose distributions are in good agreement with measurements on our machine, we have designed a set of test intensity distributions and performed measurements with 6 and 20 MV photons on a Varian Clinac 2300C/D linear accelerator equipped with a 40 leaf pair dynamic MLC. Comparison between calculated and measured dose distributions for a number of representative cases shows, in general, good agreement (within 3% of the normalization in low dose gradient regions and within 3 mm distance-to-dose in high dose gradient regions). For absolute dose calculations (monitor unit calculations), comparison between calculation and measurement reveals good agreement (within 2%) for all tested cases (with the condition that the prescription point is not located on a high dose gradient region).

Algorithms↗

A method to check the accuracy of dose computation using quality index: application to scatter contribution in high energy photon beams.

Computerized dose calculation verification is a relevant component of radiotherapy treatment planning quality assurance. The usual procedure is to compare measurements to computations for several standard situations. As cases become more complex, special test phantoms and beam arrangements must be used, and an experimental procedure must be carefully established. In this paper we follow a new methodology to prepare a set of reference data that may be used to verify the accuracy of dose calculations involving changes in the scatter component of photon beams. The advantage of this methodology is that local measurements are not required. A quantitative evaluation of dose modifications was performed by means of correction factors (CF). For this purpose, three geometrical configurations were designed (asymmetric, symmetric, and reference) where the primary component was kept constant and the scatter component was varied by changing the height (h) of lateral columns. Measurements were performed in polystyrene phantoms for seven photon beam energies. CF were derived as the ratio of the absolute dose measured at the point of interest to the absolute dose for the reference configuration, for the asymmetric and symmetric configurations, respectively. They were expressed as a function of beam quality (QI). We have verified that, for all configurations studied, CF decrease with QI. For h = 15 cm, CF remain practically constant, whatever machine technology is used [the mean values of CF for the asymmetric and symmetric cases are CFa= 1.028 (0.2% 1 s.d.) and CFs= 1.058 (0.4% 1 s.d.)]. We have developed a test protocol and we have chosen those configurations corresponding to h = 15 cm because they both present greater values of the CF and lower standard deviations. The direct application of the method is straightforward. The user can reproduce on his local TPS the three experimental configurations described in the test protocol, and then compute CF which can be compared to our reference data set for any beam quality.

Biophysical Phenomena↗

[Brachytherapy in the curative treatment of localized prostatic cancer].

The treatment of clinically localized prostate cancer is based on total prostatectomy, radiotherapy or surveillance. The adverse effects of these treatments have led to an increasing interest in alternatives with decreased morbidity. Brachytherapy consists of placing radioactive sources in the prostatic tissue. High doses can therefore be delivered to the cancer while avoiding excessive irradiation of the bladder and rectum. Brachytherapy generally uses permanent implants (Iodine 125 or Palladium 103). The so-called Seattle technique requires planning before implantation, while, in the "ProCeed" technique, the position of the grains is determined at the time of treatment, with the help of a computer programme which determines the dosimetry. Brachytherapy is a reliable and reproducible technique with minimal morbidity, providing 10-year results comparable to those of total prostatectomy.

Brachytherapy↗

The 'equivalent wedge' implementation of the Varian Enhanced Dynamic Wedge (EDW) into a treatment planning system.

The purpose of this work was to establish procedures for the implementation of the Varian Enhanced Dynamic Wedge into a treatment planning system (TPS), based as much as possible on simple theoretical considerations and already available data. A method is presented for the calculation (rather than measurement) of off-axis relative wedge transmission curves that are required by the TPS for relative dose calculations. We also present a method for absolute dose (monitor unit) calculations, based on the calculation of an effective wedge factor on the prescription point. A simple formula has been derived for the calculation of the effective wedge factor for the most general case, i.e. an arbitrary effective wedge angle, field size and prescription point. Relative dose calculations have been verified by measurements performed on a Varian Clinac 2300C/D linear accelerator, for 6 MV and 20 MV photon energies. Monitor unit calculations have also been verified experimentally for several cases such as symmetric and asymmetric fields with prescription on the collimator axis or on the geometrical centre of the asymmetric field. The presented technique provides results within 2% for both relative and absolute dose calculations for clinically relevant cases.

Algorithms↗

A preliminary comparative treatment planning study for radiotherapy of age-related maculopathy.

PURPOSE: We present a comparative planning of different approaches for external radiotherapy in age-related maculopathies. MATERIALS AND METHODS: Calculated dose distributions and dose-volume histograms for (a) bilateral irradiation with 6 MV photons, (b) a single lateral-oblique beam using either photons, electrons or protons and (c) an anterior circular proton beam. RESULTS: For lateral photon or electron beams the dose to the lens is usually lower than 10% of the dose to the macula. The entrance doses for bilateral photon beams are about 50% which increase up to 100% at the orbital bone. About 5 mm of optic nerves are irradiated at the maximal dose while the optic chiasma is spared. A single photon beam gives 50% of the dose to the fellow eye. The electron beam spares the fellow eye but gives a rather inhomogeneous dose to the target volume. For a lateral proton beam, 4 mm of optic nerve receives 90% of the dose, the skin dose is at least 70% of the dose to the macula and the lens and the fellow eye are spared. An anterior proton beam gives 90% of the dose to 1 mm of optic nerve and the 50% isodose approaches the periphery of the lens. CONCLUSION: Doses to the critical structures can be dramatically diminished for all the techniques by reducing the beam size, but only if very precise set-up techniques are used. Proton beams are an attractive solution, but the impact of such a choice on the use of proton facilities and on the national health system should be carefully evaluated, as well as the risk of radio-induced secondary neoplasias.

Humans↗

Quality control of dose volume histogram computation characteristics of 3D treatment planning systems.

Detailed quality control (QC) protocols are a necessity for modern radiotherapy departments. The established QC protocols for treatment planning systems (TPS) do not include recommendations on the advanced features of three-dimensional (3D) treatment planning, like the dose volume histograms (DVH). In this study, a test protocol for DVH characteristics was developed. The protocol assesses the consistency of the DVH computation to the dose distribution calculated by the same TPS by comparing DVH parameters with values obtained by the isodose distributions. The computation parameters (such as the dimension of the computation grid) that are applied to the TPS during the tests are not fixed but set by the user as if the test represents a typical clinical case. Six commercial TPS were examined with this protocol within the frame of the EC project Dynarad (Biomed I). The results of the intercomparison prove the consistency of the DVH results to the isodose values for most of the examined TPS. However, special attention should be paid when working with cases of adverse conditions such as high dose gradient regions. In these cases, higher errors are derived, especially when an insufficient number of dose calculation points are used for the DVH computation.

Europe↗

Evaluation of the scatter field for high-energy photon beam attenuators.

Based upon sector integration, a method has been developed to evaluate the scatter from attenuating beam modulators at any point in the field for arbitrarily shaped fields and attenuators with variable thickness. The method requires preliminary measurements of narrow and broad beam transmission fractions as a function of filter thickness and field size. The ratio Sp of the contribution from photons scattered by the attenuator to the non-attenuated primary contribution was derived from these measurements. Sp was determined for x-ray beam energies between 4 and 23 MV with brass and lead attenuators. This quantity was found to be practically independent of beam energy for a given field size and material. The variation of Sp as a function of slab thickness for attenuators covering the entire beam showed a maximum for a thickness of approximately one mean free path. This maximum represents about 6.0% of the transmitted primary dose for an extreme case of a very heavily (1.6 cm thick lead slab) attenuated 15 cm x 15 cm field. The 'scatter field', corresponding to the scatter contribution from the attenuator across the field, was calculated for different partial attenuators and wedges. The results show that this component has a limited influence on calculation of dose distribution, but should be taken into account in absolute dosimetry analysis for large fields and thick wedge filters.

Equipment Design↗

Developing a dose-volume histogram computation program for brachytherapy.

A dose-volume histogram (DVH) computation program was developed for brachytherapy treatment planning in an attempt to benefit from the DVH's ability to present graphically information on 3D dose distributions. The program is incorporated into a planning system that utilizes a pair of orthogonal radiographs to localize the radiation sources. DVHs are calculated for the volume of tissue enclosed by an isodose surface (e.g. half the value of the reference isodose). The calculation algorithm is based on a non-uniform random sampling that gives a denser point distribution at the centre of the implants. Our program was tested and proved to be fast enough for clinical use and sufficiently accurate (i.e. computation time of 20 s and less than 2% relative error for one point source, for 100,000 calculation points). The accuracy improves when a larger calculation point number is used, but the computation time also increases proportionally. The DVH is presented in the form of a simple graph or table, or as Anderson's 'natural' DVH graph. The cumulative DVH tables can be used to extract a series of indexes characterizing the homogeneity and the dose levels of the distribution in the treatment volume and the surrounding tissues. If a reference plan is available, the DVH results can be assessed relative to the reference plan's DVH.

Brachytherapy↗

Automatic three-dimensional expansion of structures applied to determination of the clinical target volume in conformal radiotherapy.

PURPOSE: A method is provided for the automatic calculation of the Clinical Target Volume (CTV) by automatic three dimensional (3D) expansion of the Gross Tumor Volume (GTV), keeping a constant margin M in all directions and taking into account anatomic obstacles. METHODS AND MATERIALS: Our model uses a description of the GTV from contours (polygons) defined in a series of parallel slices obtained from Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). Each slice is considered sequentially, including those slices located apart from the GTV at a distance smaller than M. In the current slice a two-dimensional (2D) expansion is performed by transforming each vertex of the polygon into a circle with a radius equal to M, and each segment into a rectangle with a height equal to 2M. A cartesian millimetric grid is then "projected" onto the slice and a specific value is assigned at each point depending if the point is internal to the 2D expansion. The influence in the current slice of any slice located at a distance delta z smaller than M is taken into account by applying a 2D expansion using a margin [formula: see text]. Additional contours representative of various "barriers" stopping the expansion process can also be defined. RESULTS: The method has been applied to cylindrical and spherical structures and has proven to be successful, provided that the slice thickness is small enough. For usual slice thicknesses and margins, it gives a slight overestimation of the additional volume (around 5%) due to the choice that the calculated target volume would not be less than the expected volume. It has been shown that for a spherical volume, a 2D expansion performed slice by slice leads to a volume up to 80% smaller than that obtained by 3D expansion. CONCLUSIONS: This tool, which mimics the tumor cell spreading process, has been integrated in our treatment-planning software and used clinically for conformal radiotherapy of brain and prostatic tumors. It has been found to be extremely useful, not only saving time but also allowing a precise determination of the CTV which would be impossible to do manually.

Algorithms↗

A simple method for 3D lesion reconstruction from two projected angiographic images: implementation to a stereotactic radiotherapy treatment planning system.

INTRODUCTION: The most used imaging modality for diagnosis and localisation of arteriovenous malformations (AVMs) treated with stereotactic radiotherapy is angiography. The fact that the angiographic images are projected images imposes the need of the 3D reconstruction of the lesion. This, together with the 3D head anatomy from CT images could provide all the necessary information for stereotactic treatment planning. We have developed a method to combine the complementary information provided by angiography and 2D computerized tomography, matching the reconstructed AVM structure with the reconstructed head of the patient. MATERIALS AND METHODS: The ISIS treatment planning system, developed at Institute Curie, has been used for image acquisition, stereotactic localisation and 3D visualisation. A series of CT slices are introduced in the system as well as two orthogonal angiographic projected images of the lesion. A simple computer program has been developed for the 3D reconstruction of the lesion and for the superposition of the target contour on the CT slices of the head. RESULTS AND CONCLUSIONS: In our approach we consider that the reconstruction can be made if the AVM is approximated with a number of adjacent ellipses. We assessed the method comparing the values of the reconstructed and the actual volumes of the target using linear regression analysis. For treatment planning purposes we overlapped the reconstructed AVM on the CT slices of the head. The above feature is to our knowledge a feature that the majority of the commercial stereotactic radiotherapy treatment planning system could not provide. The implementation of the method into ISIS TPS shows that we can reliably approximate and visualize the target volume.

Cerebral Angiography↗

Quality assurance in conformal radiotherapy: DYNARAD consensus report on practice guidelines.

BACKGROUND AND PURPOSE: Conformal radiotherapy has only recently been widely implemented. Although not all aspects have yet been adequately proven, it is generally recognized that maintaining a high degree of precision throughout the process is critical to the treatment outcome while the focus for quality assurance and quality improvement will need to concentrate more on human factors, procedures, communication, organization and training. A general consensus document on quality assurance guidelines for institutions that deliver conformal radiotherapy treatments to patients has been elaborated within the framework of the DYNARAD/BIOMED concerted action on conformal radiotherapy. The present paper aims to highlight those issues that were identified as of specific importance to conformal radiotherapy. The work reported here further details this guidance by direct correlation with the issues involved in the special case of conformal radiotherapy. METHODS: The DYNARAD document has been drafted in the form of a desktop guide comprising six sets of guidelines and is based on the ESTRO advisory report on 'Quality Assurance in Radiotherapy'. RESULTS AND CONCLUSIONS: The document has been endorsed by the DYNARAD group of institutions. As such it can form the basis for further discussions and enter into the subsequent phase of expanding its consensus basis.

Consensus Statements as Topic↗

A method for measuring the ionization fraction due to the chamber wall (alpha) and assessing its characteristics.

To calibrate a megavoltage therapy beam using an ionization chamber, it is necessary to know the fraction of the ionization arising in the chamber wall when this is made of a material different than the medium. A method for measuring the ionization fraction produced by electrons arising in the chamber wall (alpha) is presented here. The method uses three measurements at the same point in a medium in order to calculate alpha. These measurements are made using the examined chamber with and without a buildup cap and one reference chamber of wall material equivalent to the medium (i.e., in our case, A1 and A-150 were used as wall materials for the examined and the reference chamber, respectively). Using this method, it is possible to calculate alpha in the medium for a series of irradiation conditions and assess its characteristics. Two main conclusions came out of this assessment. The first one is the independence of alpha from the wall material, even if this is aluminum (alpha is only dependent on wall thickness expressed in g cm-2). The second one is that alpha depends on the irradiation conditions; it increases with field size and depth.

Aluminum↗

A model for the lateral penumbra in water of a 200-MeV proton beam devoted to clinical applications.

An experimental approach for modeling the lateral penumbra of a proton beam has been investigated. Measurements were made with a silicon diode in a water tank. Several geometrical configurations (phantom position, collimator-to-surface distance, collimator diameter, bolus thickness, air gap, etc.) and beam characteristics (range, modulation, etc.) have been studied. The results show that the lateral penumbra is almost independent of the beam modulation and the diameter of the collimator. The use of scaled variables for depth and penumbra allows us to represent the increase in penumbra with depth for any configuration with a second order polynomial function, provided that the penumbra at the entrance of the medium and at the depth of the range are known.

Biophysical Phenomena↗