[Radiotherapy for breast cancer: respiratory and set-up uncertainties].

Adjuvant Radiotherapy has been shown to significantly reduce locoregional recurrence but this advantage is associated with increased cardiovascular and pulmonary morbidities. All uncertainties inherent to conformal radiation therapy must be identified in order to increase the precision of treatment; misestimation of these uncertainties increases the potential risk of geometrical misses with, as a consequence, underdosage of the tumor and/or overdosage of healthy tissues. Geometric uncertainties due to respiratory movements or set-up errors are well known. Two strategies have been proposed to limit their effect: quantification of these uncertainties, which are then taken into account in the final calculation of safety margins and/or reduction of respiratory and set-up uncertainties by an efficient immobilization or gating systems. Measured on portal films with two tangential fields, CLD (central lung distance), defined as the distance between the deep field edge and the interior chest wall at the central axis, seems to be the best predictor of set-up uncertainties. Using CLD, estimated mean set-up errors from the literature are 3.8 and 3.2 mm for the systematic and random errors respectively. These depend partly on the type of immobilization device and could be reduced by the use of portal imaging systems. Furthermore, breast is mobile during respiration with motion amplitude as high as 0.8 to 10 mm in the anteroposterior direction. Respiratory gating techniques, currently on evaluation, have the potential to reduce effect of these movements. Each radiotherapy department should perform its own assessments and determine the geometric uncertainties with respect of the equipment used and its particular treatment practices. This paper is a review of the main geometric uncertainties in breast treatment, due to respiration and set-up, and solutions proposed to limit their impact.

Breast Neoplasms↗

The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters.

For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim of this study is twofold: a methodology based on the 'sliding slit' test is proposed to determine (T, DLS) combinations inducing the best conformity between calculations and measurements. Secondly, the effects of the MLC adjustment on measured dose and on optimization are presented for different configurations as the chair test and for the patient dosimetric quality control (DQC). Tests were performed with a Varian 23EX linac operated at 20 MV and equipped with a 120 leaf Millenium dynamic collimator. The treatment planning system was CadPlan/Helios (version 6.3.6). Results demonstrated that the sliding width (SW) strongly depends on the (T, DLS) combinations, and the measured dose is a linear function of the SW. Different (T, DLS) combinations induced a good agreement between calculations and measurements. The influence of the MLC calibration was found to be particularly important on the 'sliding slit' test (11.8% for a gap change of 0.8 mm) but not so much on the chair test and on the DQC. To detect small variations in leaf adjustment and to ensure consistency between calculation and actual dose delivered to patients, a daily check called IMRT MU check is proposed.

Calibration↗

[Constraints and dosage for prostate cancer patients treated with conformal radiotherapy and intensity modulated radiation therapy].

PURPOSE: Intensity modulated radiation therapy (IMRT) is based on a methodology called inverse planning. Starting from dosimetric objectives, constraints of optimization are fixed and given to the inverse planning system, which in turn calculates the modulated intensity to apply to each beam. Since the algorithms allow the constraints to be violated, the results of optimization may differ from the initial dosimetric objectives. Consequently, the user is compelled to adapt the choice of the constraints according to the type of modulation and until satisfactory results are found. The purpose of this work is to present our experience in the choice of these constraints for prostate cancer treatments, as we moved from conformal radiotherapy to IMRT. Treatments were performed with a Varian 23EX linac and calculations were realized with the Varian CadPlan-Helios planning system. PATIENTS AND METHODS: The approach used for the first 12 patients treated at institut Curie with IMRT from June 2002 was analysed. The treatment always consisted of a combination of conformal radiotherapy with and without intensity modulation. RESULTS AND CONCLUSION: Results showed that, a larger fraction of the treatment performed with IMRT induced a better sparing of the organs at risk for the same homogeneous dose distribution to the target volume. Apart from the dose-volume constraint for the rectum, a fixed set of constraints, slightly more restrictive than the dosimetric objectives, could be used for all patients. Compared with conformal radiotherapy, the conformation factor for IMRT increased up to 16%. A specific study was undertaken in view of treatments completely performed with IMRT. The optimal technique consisted in performing separated IMRT plans for the two target volumes, the prostate volume and the prostate plus seminal vesicles volume respectively. Another satisfactory possibility was to define new constraints on two separated planning target volumes, prostate and seminal vesicles. This last approach is now routinely implemented for our IMRT patients.

Humans↗

[CT and MR image fusion using two different methods after prostate brachytherapy: impact on post-implant dosimetric assessment].

PURPOSE: To study different methods of CT and MR images fusion in patient treated by brachytherapy for localized prostate cancer. To compare the results of the dosimetric study realized on CT slices and images fusion. MATERIALS AND METHODS: Fourteen cases of patients treated by I125 were retrospectively studied. The CT examinations were realized with contiguous section of 5mm thickness, and MR images were obtained with a surface coil with contiguous section of 3 mm thickness. For the images fusion process, only the T2 weighted MR sequence was used. Two processes of images fusion were realized for each patient, using as reference marks the bones of the pelvis and the implanted seeds. A quantitative and qualitative appreciation was made by the operators, for each patient and both methods of images fusion. The dosimetric study obtained by a dedicated software was realized on CT images and all types of images fusion. The usual dosimetric indexes (D90, V100 and V150) were compared for each type of image. RESULTS: The quantitative results given by the software of images fusion showed a superior accuracy to the one obtained by the pelvic bony reference marks. Conversely, qualitative and quantitative results obtained by the operators showed a better accuracy of the images fusion based on iodine seeds. For two patients out of three presenting a D90 inferior to 145 Gy on CT examination, the D90 was superior to this norm when the dosimetry was based on images fusion, whatever the method used. CONCLUSION: The images fusion method based on implanted seed matching seems to be more precise than the one using bony reference marks. The dosimetric study realized on images fusion could allow to rectify possible errors, mainly due to difficulties in surrounding prostate contour delimitation on CT images.

Adenocarcinoma↗

[Treatment of uveal melanoma with iodine 125 plaques or proton beam therapy: indications and comparison of local recurrence rates].

INTRODUCTION: This retrospective study compared the rate of local recurrence after irradiation of uveal melanoma treated with iodine 125 plaques or proton beam therapy. PATIENTS AND METHODS: Iodine 125 plaques were used to treat all uveal melanomas between the end of 1989 and 1991. Since 1991, we have used iodine plaques for small anterior tumors and proton beam for other tumors. We use a plaque with a larger diameter than the tumor diameter (2-4mm) with a dose of 90Gy at the apex. Proton beam therapy is used for all tumors at the equator or posterior to the equator not thicker than 12mm. The dose given is 60Gy cobalt equivalent in four fractions. For each patient, the initial size and location of the tumor were noted as well as the follow-up each year: the outcome for the eye (local recurrence, ocular conservation, and functional results), the occurrence of metastasis, and survival. A statistical analysis was performed. RESULTS: Between December 1989 and September 1998, 1272 patients were treated: 926 (72.8%) were treated with proton beam irradiation and 346 (27.8%) with iodine 125 plaques. The median follow-up was 5 years (60 months). For the patients treated with proton beam therapy, the mean age was 58 years, the tumor location was anterior to the equator for 3.8%, at the equator for 43.6%, and posterior to the equator for 52.6%. The mean tumor diameter was 13.4mm and the mean tumor thickness was 5.69mm. For the patients treated with iodine 125 plaques, the mean age was 61.5 years. The location of the tumor was anterior to the equator for 34.4%, at the equator for 46.5%, and posterior to the equator for 19.1%. The mean tumor diameter was 11.5mm and the mean tumor thickness was 5.12mm. The recurrence rate was 4% for the proton beam treatment and 3.75% for iodine plaques. There was no statistical difference. DISCUSSION: In the literature, the rate of local recurrence is usually higher with iodine 125 plaques than proton beam therapy. We discuss the risk factors for local recurrence after iodine 125 plaques: tumor diameter, lower dose to the tumor apex and lower dose rate, and posterior location of the tumor. We found a higher mortality rate in patients who presented local recurrence. CONCLUSION: When we use iodine 125 plaques for anterior tumors with the proper dose and dose rate to the apex of the tumor, we do not find more recurrence than with proton beam therapy.

Adolescent↗

[Respiration-gated radiotherapy: current techniques and potential benefits].

Respiration-gated radiotherapy offers a significant potential for improvement in the irradiation of tumor sites affected by respiratory motion such as lung, breast and liver tumors. An increased conformality of irradiation fields leading to decreased complications rates of organs at risk (lung, heart...) is expected. Respiratory gating is in line with the need for improved precision required by radiotherapy techniques such as 3D conformal radiotherapy or intensity modulated radiotherapy. Reduction of respiratory motion can be achieved by using either breath hold techniques or respiration synchronized gating techniques. Breathhold techniques can be achieved with active, in which airflow of the patient is temporarily blocked by a valve, or passive techniques, in which the patient voluntarily breath-hold. Synchronized gating techniques use external devices to predict the phase of the respiration cycle while the patient breaths freely. These techniques presently investigated in several medical centers worldwide. Although promising, the first results obtained in lung and liver cancer patients require confirmation. Physical, technical and physiological questions still remain to be answered. This paper describes the most frequently used gated techniques and the main published clinical reports on the use of respiration-gated radiotherapy in order to evaluate the impact of these techniques.

Breast Neoplasms↗

[Indications for curietherapy of the prostate using permanent implants].

In the last decade, brachytherapy emerged as a particularly appealing new way ot treating localized prostate cancer. Recently published 10-12 years biochemical control results appear to be superimposable to the best percentages achieved by surgery or conformal radiotherapy, with a small percentage of complications. This applied to severely patients. Only patients with T1/T2, PSA < 10 ng/mL, and Gleason score < 7 should be proposed such a treatment. The potential benefit of exploring patients with a endorectal coil MRI is being evaluated. The number of positive biopsies is also a parameter which should probably be considered in the therapeutic choice. Moreover, a prostate volume > 60 g, hip mobility limitations, a urinary obstructive syndrome and previous transurethral resection lead to difficulties in technical implantation and therefore must be taken into account when discussing brachytherapy. In conclusion, for adequately selected patients, brachytherapy offers a particularly applied alternative to surgery and external radiotherapy, with satisfactory long term biochemical control rates and limited complications.

Adenocarcinoma↗

[Upper aerodigestive tract cancers: clinical benefits of conformal radiotherapy and intensity modulation].

The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) or intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3D treatment planning systems, sophisticated immobilization systems and rigorous quality assurance and treatment verification. The central objective of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of normal tissues. These techniques would then allow further tumor dose escalation. Head-and-neck tumors are some of the most attractive localizations to test conformal radiotherapy. They combine ballistic difficulties due to particularly complex shapes (nasopharynx, ethmoid) and problems due to the number and low tolerance of neighbouring organs like parotids, eyes, brainstem and spinal cord. The therapeutic irradiation of head-and-neck tumors thus remains a challenge for the radiation oncologist. Conformal radiotherapy does have a significant potential for improving local control and reducing toxicity when compared to standard radiotherapy. However, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from 3DCRT and IMRT. The published clinical reports on the use of conformal radiotherapy are essentially dealing with dosimetric comparisons on relatively small numbers of patients. Recently, a few publications have emphasized the clinical experience of several precursor teams with a suitable follow-up. This paper describes the current state-of-the-art of 3DCRT and IMRT in order to evaluate the impact of these techniques on head-and-neck cancers irradiation.

Central Nervous System↗

[Non-small-cell bronchial cancers: improvement of survival probability by conformal radiotherapy].

The conformal radiotherapy approach, three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT), is based on modern imaging modalities, efficient 3D treatment planning systems, sophisticated immobilization devices and demanding quality assurance and treatment verification. The main goal of conformal radiotherapy is to ensure a high dose distribution tailored to the limits of the target volume while reducing exposure of healthy tissues. These techniques would then allow a further dose escalation increasing local control and survival. Non-small cell lung cancer (NSCLC) is one of the most difficult malignant tumors to be treated. It combines geometrical difficulties due to respiratory motion, and number of low tolerance neighboring organs, and dosimetric difficulties because of the presence of huge inhomogeneities. This localization is an attractive and ambitious example for the evaluation of new techniques. However, the published clinical reports in the last years described very heterogeneous techniques and, in the absence of prospective randomized trials, it is somewhat difficult at present to evaluate the real benefits drawn from those conformal radiotherapy techniques. After reviewing the rationale for 3DCRT for NSCLC, this paper will describe the main studies of 3DCRT, in order to evaluate its impact on lung cancer treatment. Then, the current state-of-the-art of IMRT and the last technical and therapeutic innovations in NSCLC will be discussed.

Carcinoma, Non-Small-Cell Lung↗

[Safety in radiotherapy: Control of software and informatics systems].

The development of computerized systems in radiotherapy opens new challenging possibilities. There is however a major risk of specific errors if the use of such systems is not properly controlled. On the other hand, the software sophistication, such as encountered in modern treatment planning systems (TPS), makes it very difficult to set up efficient quality assurance programs compatible with the workload of users in charge of daily routine. From the analysis of previous accidents involving TPS, we can conclude that the major risks are erroneous calculations of monitor units resulting from a poor understanding of the software capabilities combined to a lack of vigilance with respect to the data obtained from a computer. To reduce the risks, it is necessary to setup a comprehensive quality assurance program covering all steps of the process, including commissioning of a new system and systematic checks of individual treatment plans. Such a program offers the users the opportunity to acquire a deeper understanding of the system and avoid potential pitfalls. There is presently a lack of consensus for an international protocol related to quality assurance of computerized systems in radiotherapy. It is therefore important to define protocols at the national level, with special consideration of the aspects which are more likely to generate significant errors.

Computer Simulation↗

Conformal radiotherapy (CRT) planning for lung cancer: analysis of intrathoracic organ motion during extreme phases of breathing.

PURPOSE: Conformal radiotherapy beams are defined on the basis of static computed tomography acquisitions by taking into account setup errors and organ/tumor motion during breathing. In the absence of precise data, the size of the margins is estimated arbitrarily. The objective of this study was to evaluate the amplitude of maximum intrathoracic organ motion during breathing. METHODS AND MATERIALS: Twenty patients treated for non-small-cell lung cancer were included in the study: 10 patients at the Institut Curie with a personalized alpha cradle immobilization and 10 patients at Tenon Hospital with just the Posirest device below their arms. Three computed tomography acquisitions were performed in the treatment position: the first during free breathing and the other two during deep breath-hold inspiration and expiration. For each acquisition, the displacements of the various intrathoracic structures were measured in three dimensions. RESULTS: Patients from the two centers were comparable in terms of age, weight, height, tumor site, and stage. In the overall population, the greatest displacements were observed for the diaphragm, and the smallest displacements were observed for the lung apices and carina. The relative amplitude of motion was comparable between the two centers. The use of a personalized immobilization device reduced lateral thoracic movements (p < 0.02) and lung apex movements (p < 0.02). CONCLUSION: Intrathoracic organ movements during extreme phases of breathing are considerable. Quantification of organ motion is necessary for definition of the safety margins. A personalized immobilization device appears to effectively reduce apical and lateral displacement.

Aged↗

CT and (18)F-deoxyglucose (FDG) image fusion for optimization of conformal radiotherapy of lung cancers.

PURPOSE: To validate a computed tomography (CT) and (18)F-deoxyglucose (FDG) image fusion procedure and to evaluate its usefulness to facilitate target definition and treatment planning in three-dimensional conformal radiation therapy (3D-CRT) for non-small-cell lung cancer. METHODS AND MATERIALS: Twelve patients were assessed by CT and FDG-coincidence mode dual-head gamma camera (CDET) before radiotherapy. The patients were placed in a similar position during CT and FDG-CDET. Matching was achieved by minimizing the cost function by 3D translation and rotation between four landmarks drawn on the patient's skin. Virtual simulation was performed from image fusion and estimated dose-volume histograms (DVH) were calculated. RESULTS: Quantitative analysis indicated that the matching error was < 5 mm. Fusion of anatomic and metabolic data corrected staging of lymph nodes (N) for 4 patients and staging of metastases for 1 patient. In these 5 patients, DVH revealed that the lung volume irradiated at 20 Gy (Vl(20)) was decreased by an average of 22.8%, and tumor volume irradiated at the 95% isodose (V(95)) was increased by 22% and 8% for 2 patients, respectively, and was decreased by an average of 59% for 3 patients after fusion. No difference in terms of Vl(20) and V(95) was observed for the other 7 patients. CONCLUSION: We have validated CT and FDG-CDET lung image fusion to facilitate determination of lung cancer volumes, which improved the accuracy of 3D-CRT.

Carcinoma, Non-Small-Cell Lung↗

[Estimation of the probability of mediastinal involvement: a statistical definition of the clinical target volume for 3-dimensional conformal radiotherapy in non-small-cell lung cancer?].

PURPOSE: Conformal irradiation of non-small cell lung carcinoma (NSCLC) is largely based on a precise definition of the nodal clinical target volume (CTVn). The reduction of the number of nodal stations to be irradiated would render tumor dose escalation more achievable. The aim of this work was to design an mathematical tool based on documented data, that would predict the risk of metastatic involvement for each nodal station. METHODS AND MATERIAL: From the large surgical series published in the literature we looked at the main pre-treatment parameters that modify the risk of nodal invasion. The probability of involvement for the 17 nodal stations described by the American Thoracic Society (ATS) was computed from all these publications and then weighted according to the French epidemiological data. Starting from the primitive location of the tumour as the main characteristic, we built a probabilistic tree for each nodal station representing the risk distribution as a function of each tumor feature. From the statistical point of view, we used the inversion of probability trees method described by Weinstein and Feinberg. RESULTS: Taking into account all the different parameters of the pre-treatment staging relative to each level of the ATS map brings up to 20,000 different combinations. The first chosen parameters in the tree were, depending on the tumour location, the histological classification, the metastatic stage, the nodal stage weighted in function of the sensitivity and specificity of the diagnostic examination used (PET scan, CAT scan) and the tumoral stage. A software is proposed to compute a predicted probability of involvement of each nodal station for any given clinical presentation. CONCLUSION: To better define the CTVn in NSCLC 3DRT, we propose a software that evaluates the mediastinal nodal involvement risk from easily accessible individual pre-treatment parameters.

Carcinoma, Non-Small-Cell Lung↗

Variation of sensitometric curves of radiographic films in high energy photon beams.

Film dosimetry is an important tool for the verification of irradiation techniques. The shape of the sensitometric curve depends on the type of film as well as on the irradiation and processing conditions. Existing data concerning the influence of irradiation geometry on the sensitometric curve are conflicting. In particular the variation of optical density, OD, with field size and depth in a phantom shows large differences in magnitude between various authors. This variation, as well as the effect of beam energy and film plane orientation on OD, was therefore investigated for two types of film, Kodak X-Omat V and Agfa Structurix D2. Films were positioned in a solid phantom, either perpendicular or (almost) parallel to the beam axis, and irradiated to different dose levels using various photon beams (Co-60, 6 MV, 15 MV, 18 MV, 45 MV). It was found that the sensitometric curves of the Kodak film derived at different depths are almost identical for the four x-ray beams. For the Kodak film the differences in OD with depth are less than 2%, except for the Co-60 beam, where the difference is about 4% at 10 cm depth for a 15 cm x 15 cm field. The slope of the sensitometric curve of the Agfa film is somewhat more dependent on photon beam energy, depth and field size. The sensitometric curves of both types of film are almost independent of the film plane orientation, except for shallow depths. For Co-60 and for the same dose, the Kodak and Agfa films gave at dose maximum an OD lower by 4% and 6%, respectively, for the parallel compared to the perpendicular geometry. Good dosimetric results can be obtained if films from the same batch are irradiated with small to moderate field sizes (up to about 15 cm x 15 cm), at moderate depths (up to about 15 cm), using a single calibration curve, e.g., for a 10 cm x 10 cm field.

Biophysical Phenomena↗

Experimental determination and verification of the parameters used in a proton pencil beam algorithm.

We present an experimental procedure for the determination and the verification under practical conditions of physical and computational parameters used in our proton pencil beam algorithm. The calculation of the dose delivered by a single pencil beam relies on a measured spread-out Bragg peak, and the description of its radial spread at depth features simple specific parameters accounting individually for the influence of the beam line as a whole, the beam energy modulation, the compensator, and the patient medium. For determining the experimental values of the physical parameters related to proton scattering, we utilized a simple relation between Gaussian radial spreads and the width of lateral penumbras. The contribution from the beam line has been extracted from lateral penumbra measurements in air: a linear variation with the distance collimator-point has been observed. Analytically predicted radial spreads within the patient were in good agreement with experimental values in water under various reference conditions. Results indicated no significant influence of the beam energy modulation. Using measurements in presence of Plexiglas slabs, a simple assumption on the effective source of scattering due to the compensator has been stated, leading to accurate radial spread calculations. Dose measurements in presence of complexly shaped compensators have been used to assess the performances of the algorithm supplied with the adequate physical parameters. One of these compensators has also been used, together with a reference configuration, for investigating a set of computational parameters decreasing the calculation time while maintaining a high level of accuracy. Faster dose computations have been performed for algorithm evaluation in the presence of geometrical and patient compensators, and have shown good agreement with the measured dose distributions.

Algorithms↗

Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning.

PURPOSE: One of the most difficult steps of the three-dimensional conformal radiotherapy (3DCRT) is to define the clinical target volume (CTV) according to the degree of local microscopic extension (ME). In this study, we tried to quantify this ME in non-small-cell lung cancer (NSCLC). MATERIAL AND METHODS: Seventy NSCLC surgical resection specimens for which the border between tumor and adjacent lung parenchyma were examined on routine sections. This border was identified with the naked eye, outlined with a marker pen, and the value of the local ME outside of this border was measured with an eyepiece micrometer. The pattern of histologic spread was also determined. RESULTS: A total of 354 slides were examined, corresponding to 176 slides for adenocarcinoma (ADC) and 178 slides for squamous cell carcinoma (SCC). The mean value of ME was 2.69 mm for ADC and 1.48 mm for SCC (p = 0.01). The usual 5-mm margin covers 80% of the ME for ADC and 91% for SCC. To take into account 95% of the ME, a margin of 8 mm and 6 mm must be chosen for ADC and SCC, respectively. Aerogenous dissemination was the most frequent pattern observed for all groups, followed by lymphatic invasion for ADC and interstitial extension for SCC. CONCLUSION: The ME was different between ADC and SCC. The usual CTV margin of 5 mm appears inadequate to cover the ME for either group, and it must be increased to 8 mm and 6 mm for ADC and SCC, respectively, to cover 95% of the ME. This approach is obviously integrated into the overall 3DCRT procedure and with other margins.

Adenocarcinoma↗

AVS/express for the PC implementation of a 3D visualization module for radiotherapy.

Treatment planning systems (TPS) are nowadays of great help in cancer radiotherapy. Basically, they allow the pair physician/physicist to simulate the beams' irradiation effects on tumors as well as healthy tissues in terms of delivered radiation doses and finally to assess the validity of a beam setup. The state of the art in TPS leads to the following evidence concerning the future of such softwares: an access to a 3D visualization at each step of the design and verification of a plan has become necessary. Moreover, the fast increasing performances of personal computers (PC) will make possible in a near future the implementation at a lower cost of a complete 3D TPS. One of the keys of such an ambition is the compatibility between the implementation tools and the needs for power and flexibility. A first implementation on Open VMS of a simple 3D visualization for Institut Curie's TPS ISIS using Advanced Visual Systems' AVS 5 has been achieved. Their next generation tool, AVS/Express, seemed to meet the needs of a wide scale development. The use of AVS/Express working together with Microsoft Visual C++ in the implementation on Windows NT of a 3D visualization module is exposed.

Humans↗

Comparison of conformal radiation therapy techniques within the dynamic radiotherapy project 'Dynarad'.

The objective of the dynamic radiotherapy project 'Dynarad' within the European Community has been to compare and grade treatment techniques that are currently applied or being developed at the participating institutions. Cervical cancer was selected as the tumour site on the grounds that the involved organs at risk, mainly the rectum and the bladder, are very close to the tumour and partly located inside the internal target volume. In this work, a solid phantom simulating the pelvic anatomy was used by institutions in Belgium, France, Greece, Holland, Italy, Sweden and the United Kingdom. The results were evaluated using both biological and physical criteria. The main purpose of this parallel evaluation is to test the value of biological and physical evaluations in comparing treatment techniques. It is demonstrated that the biological objective functions allow a much higher conformality and a more clinically relevant scoring of the outcome. Often external beam treatment techniques have to be combined with intracavitary therapy to give clinically acceptable results. However, recent developments can reduce or even eliminate this need by delivering more conformal dose distributions using intensity modulated external dose delivery. In these cases the reliability of the patient set-up procedure becomes critical for the effectiveness of the treatment.

European Union↗