Search PubMed⌕ Search

Biomedical subjects

J C Moore

Publications and source records attributed to J C Moore.

121 records · Page 7Linked to original sources

Involvement of proteolytic enzymes--plasminogen activators and matrix metalloproteinases--in the pathophysiology of pressure ulcers.

The role of matrix-degrading enzymes, particularly plasminogen activators and matrix metalloproteinases, in the acute wound healing response has been the focus of many scientific studies. Only recently have these classes of endogenously produced proteinases been studied with regard to their involvement in the chronic wound environment. Using both in situ histologic zymography and immunohistochemical techniques, we examined the distribution of plasminogen activators and matrix metalloproteinase in the granulation tissue of pressure ulcers. Using in situ histologic zymography, urokinase was found to be the predominant plasminogen activator activity in the chronic wound granulation tissue, with little or no tissue-type plasminogen activator activity. These results were confirmed with the use of immunohistochemical techniques. In contrast, tissue-type plasminogen activator was found to be constitutively expressed in normal skin. Levels of matrix metalloproteinases were also found to be elevated in the granulation tissue of pressure ulcers. Immunohistochemical localization of leukocyte-associated proteinases (PMN elastase and cathepsin G) suggested a highly inflamed environment within the pressure ulcer granulation tissue. These results suggest a highly proteolytic environment within the chronic wound.

Journal Article↗

Glycosylated haemoglobin measurement on blood samples taken by patients: an additional aid to assessing diabetic control.

200 patients attending a diabetic outpatient clinic were each asked to post to the hospital, prior to their three-monthly routine clinic visit, a finger-prick capillary blood sample for glycosylated haemoglobin assay (HbA1). Patients took their own blood into UNISTEP bottles, which automatically measure a 53 microliters aliquot and mix it with 150 microliters of diluent suitable for transport to the laboratory. During 1 year 883 (84%) of 1046 bottles sent out were returned of which 776 (87%) were suitable for analysis. The availability of the result at the time of the patients' clinic visit aided assessment of diabetic control and was associated with a mean reduction of the HbA1 by 0.8% (p less than 0.001) over a twelve-month period. This simple system facilitates remote monitoring of HbA1 levels, is suitable for both hospital and general practice use and may allow a reduction in the number of patient visits.

Diabetes Mellitus, Type 1↗