Dacron-woven pacemaker pouch. Influence on long-term pacemaker mobility.

Pacemaker migration can interfere with correct pacing system function and patient comfort. A Dacron pouch has been developed which may prevent these problems. To assess the efficacy of the pouch, we measured various factors of pacemaker mobility in 100 patients after long-term follow-up. The patients were divided into three groups on the basis of their dictated operative reports: group 1, no pouch or anchoring stitch; group 2, pouch only; group 3, anchoring stitch to pacemaker header or pouch. The average age of the study population was 74.3 +/- 11 years. Total follow-up time was 42 +/- 28 months (group I, 53 +/- 32 months; group 2, 36 +/- 23 months; group 3, 34 +/- 25 months). There were no significant differences when pacemakers were measured for movement in the inferosuperior and lateromedial directions, nor was there any difference in the distance between the incision scar and the pacemaker header in any group. There was a significant difference between group 1 and groups 2 and 3 when the degree of tilt of the pacemaker off the chest wall was compared. This was 46 degrees +/- 34 degrees for group 1 and 27 degrees +/- 26 degrees and 26 degrees +/- 27 degrees for groups 2 and 3, respectively (p less than 0.02 for both). These data suggest that the Dacron pouch does not restrict pacemaker mobility parallel to the chest wall during long-term follow-up but does reduce the angle to which the pacemaker can be tilted relative to the chest wall.

Aged

Enhancement of anthracycline and alkylator cytotoxicity by ethacrynic acid in primary cultures of human tissues.

Ethacrynic acid [2,3-dichloro-4-(2-methylene-1-oxobutyl)phenoxyl] acetic acid, is a water-soluble diuretic agent that has been shown to potentiate the in vitro cytotoxicity of chemotherapeutic agents in established cell lines. We used the differential staining cytotoxicity (DiSC) assay to determine whether ethacrynic acid at 1 and 3.3 microM would potentiate the cytotoxicity of nitrogen mustard and/or doxorubicin in primary cultures of hematologic neoplasms from heavily pretreated patients and in normal peripheral blood lymphocytes. At 3.3 microM, ethacrynic acid was toxic to 8 of 24 (33%) tumor specimens studied. In subsequent studies, ethacrynic acid at 1 microM was toxic to only 2 of 54 (4%) tumor specimens. Significant enhancement for doxorubicin or nitrogen mustard was confined to lymphatic malignancies and to normal peripheral blood lymphocytes. Interspecimen variability was observed, with no enhancement in most individual specimens, 2-fold enhancement in some specimens, and 4-fold enhancement in occasional specimens. Clinical trials will be required to determine whether the observed in vitro activity for ethacrynic acid is associated with clinical benefit in unselected or assay-selected patients.

Cell Survival

Atrial automatic tachycardia-reversion pacemakers: their economic viability and impact on quality-of-life.

UNLABELLED: Refractory supraventricular tachyarrhythmias may be both difficult and costly to control medically and can interfere with the patient's lifestyle. Newer treatment modalities are available for their management, and these require comprehensive assessment. We therefore compared costs and selective indices of patient benefit in a group of 17 patients in whom an atrial antitachycardia (Intermedics Intertach 262-12) pacemaker was placed for refractory supraventricular tachyarrhythmias. Prior medical therapy was compared to subsequent automatic antitachycardia pacemaker treatment. The total medical costs (admissions, emergency room visits, office visits, and medication costs) and the number of hospitalizations and medications were compared prior to implantation (F/U 69.3 +/- 61 months) and after implantation (F/U 15.3 +/- 7.8 months). A detailed quality-of-life questionnaire was also obtained 36.6 +/- 11 months after implantation. RESULTS: There were significant per patient differences in total cost before and after implantation: monthly costs were $505 +/- $833 before pacemaker implantation and $105 +/- $117 monthly afterward (P less than 0.005). Pacemaker implantation hospitalization costs were $19,063 +/- $8,362. Monthly medication costs averaged $46 before versus $15 after implantation (P less than 0.01). The number of medication types also differed with an average 5.5 medication types per patient before versus 1.2 after implantation (P less than 0.001). There were 8.6 yearly hospital admissions in the whole group before implantation, versus 4.7 admissions in the group per year thereafter. Patients demonstrated significant improvement in 80% of the quality-of-life parameters studied. CONCLUSION: Adjunctive atrial automatic tachycardia-reversion pacemaker therapy may be cost-competitive over time when compared to medical therapy alone in patients with refractory supraventricular tachyarrhythmias and appears to improve overall quality-of-life.

Costs and Cost Analysis

The influence of endocardial electrode fixation status on acute and chronic atrial stimulation threshold and atrial endocardial electrogram amplitude.

UNLABELLED: The endocardial atrial electrogram or "P wave amplitude" (PWA) and pacemaker atrial stimulation thresholds are important parameters determining correct pacing system function. Pacemaker lead fixation mechanism and lead age may negatively influence these parameters. Therefore, we compared acute and chronic PWA and atrial stimulation thresholds in 33 patients with permanent transvenous atrial screw-in leads, follow-up 647 days +/- 297 days; and in 31 patients with nonscrew leads, follow-up 855 days +/- 512 days (P = ns). RESULTS: The PWA differed between the two lead types acutely (1.97 mV +/- 0.8 mV for screw-in versus 2.48 mV +/- 1.1 mV for nonscrew-in leads; P less than 0.05), but not chronically (2.21 mV +/- 0.8 mV vs 2.2 mV +/- 1.2 mV; P = ns). Acute and chronic atrial pacing thresholds did not differ between groups. We also analyzed an early interim PWA in a subgroup of patients (mean 31 days after implantation). The nonscrew fixation group interim PWA was 1.76 mV +/- 0.9 mV versus 2.7 mV +/- 1.2 mV at implant (P less than 0.001). The screw-in lead interim PWA was 2.04 mV +/- 0.9 mV versus 1.97 mV +/- 0.7 mV at implant (P = ns). CONCLUSIONS: (1) A significantly higher endocardial PWA occurs at the time of lead implantation in nonscrew versus screw-in lead groups, but the chronic PWA does not differ between the two groups. (2) A transient but marked early (mean approximately 31 days) attenuation of the PWA occurs only with nonscrew-in leads. (3) Atrial threshold stimulation energies do not differ between the two lead groups acutely or during follow-up.

Aged

Physical determinants of the endocardial P wave.

UNLABELLED: Reliable atrial sensing of intrinsic P wave activity is important to ensure optimal atrial or dual chamber pacemaker function. Various physical factors (e.g., posture, respiration, exercise) may influence P wave characteristics and impair adequate sensing. To investigate this phenomenon, we measured the average of three P wave amplitudes (PWA) and calculated slew rates from telemetered printouts acquired from Pacesetter pacemakers in 32 patients. These measurements were performed in various body positions, with upright exercise and in varying stages of respiration. RESULTS: the mean supine PWA increased on full inspiration (3.56 +/- 1.3 mV versus 3.25 +/- 1.2 mV during quiet respiration, P less than 0.001), and also increased significantly with full expiration. The mean PWA increased on assuming the erect position (3.25 +/- 1.2 mV increasing to 3.49 +/- 1.3 mV, P less than 0.001); in the upright position, the mean erect PWA during quiet respiration was not significantly influenced by the stage of respiration. The mean upright exercise PWA did not differ significantly from the preexercise erect PWA (3.50 +/- 1.2 with exercise, and 3.47 +/- 1.5 before exercise; P = NS). Calculated slew rates were not different lying versus standing. CONCLUSIONS: the mean supine PWA increases significantly at the extremes of respiration and on assuming the erect body position; upright exercise results in no appreciable change in the erect PWA. Atrial sensitivity adjustments based on standard supine testing should be adequate for all body positions.

Adolescent

True incidence of pacemaker syndrome.

Although the purported incidence of pacemaker syndrome according to the literature is only 5%-15%, this is based on a series of patients with VVI pacing. Increasing numbers of studies are being reported in which patients prefer the dual chamber mode despite little benefit being demonstrated on objective testing, suggesting that pacemaker syndrome may be more common than is generally reported. This study was designed to evaluate the reported symptoms in a series of patients programmed to both the VVI and one or more dual chamber modes. Forty unselected patients with dual chamber pacemakers were entered into a blind, randomized trial comparing the symptoms associated with VVI pacing to those associated with dual chamber pacing. Patients were randomized to either VVI or dual chamber pacing. At the end of 1 week, questionnaires rating 16 different symptoms were completed. Blood pressure, LV function, presence of ventriculoatrial conduction, and ability to override the pacemaker were evaluated. The pacemaker was then programmed to the other mode. Overall, 12 of 16 symptoms were significantly worse in the VVI as compared to dual chamber mode. The most highly significant (P less than 0.005) were shortness of breath, dizziness, fatigue, pulsations in the neck or abdomen, cough, and apprehension. Pacemaker syndrome was clinically recognized in 83% of patients paced in the VVI mode with 65% of patients experiencing moderate to severe symptoms. There were no readily identified clinical, hemodynamic, or electrophysiological parameters that predicted which patients would develop pacemaker syndrome. Thus, when patients have an opportunity to experience both pacing modes in close proximity to one another, there is a high incidence of pacemaker syndrome in the VVI mode.

Aged

Chronotropic incompetence in exercise testing.

Patients with chronotropic incompetence, defined as a failure of the heart rate response to exercise to rise to within two standard deviations of the expected increase with exercise, where studied and compared to patients with known coronary disease by angiogram with and without ST segment depression. 72% of the patients with chronotropic incompetence but without ST depression had significant coronary heart disease. The demonstration of chronotropic incompetence in exercise testing has important predictive implications and should be looked upon as carefully as ST segment changes. There was no evidence of SA node ischemia in these patients. Intrinsic heart rate measurements done in this study suggest autonomic dysfunction as a possible pathophysiologic mechanism for chronotropic incompetence. The heart rate response to exercise may be a useful predictor of the presence and severity of coronary disease. Therefore, a predicted heart rate response with standard deviation for age and sex should be included as part of the stress test protocol.

Adult

Cardiac dysfunction in a patient with familial hypokalemic periodic paralysis.

A 19-year-old white man with familial hypokalemic periodic paralysis developed evidence of cardiac dysfunction during a episode of flaccid paralysis. This consisted of elevated total creatine phosphokinase (CPK), an increased myocardial fraction of CPK (myocardial band), alteration in the lactic dehydrogenase isoenzyme pattern, severe bradycardia, and evidence of left ventricular dysfunction. These findings, in conjunction with selected cases from the literature, suggest the possibility that cardiomyopathy may be a heretofore unrecognized complication of this disorder.

Adult