Orthostatic tremor: an electrophysiological analysis.

Orthostatic tremor (OT) is a clinically defined syndrome of leg tremor while standing. Controversy surrounds whether OT is a distinct syndrome or is an essential tremor (ET) variant. We report two patients with OT. Electrophysiological testing included polymyography, accelerometry, nerve conduction, and evoked potential studies. The effects of various maneuvers and body positions on the tremor were assessed. The findings included rapid (15-17 Hz) lower-extremity tremor burst frequency evoked by standing but not by walking or swaying; rapid upper-extremity burst pattern synchronous with lower-extremity bursts; and failure of electrical stimulation or mental concentration to "reset" the tremor. Additionally, there was the novel finding of accelerometric recordings in the legs revealing the same rapid frequency (16-17 Hz) as the electromyographic tremor bursts. Some prior reports have suggested that OT is related to ET by emphasizing a considerable disparity and variability between the accelerometric tremor frequency and the electromyographic burst frequency. In our patients, however, the rapid (15-17 Hz) accelerometer-recorded tremor synchronous with the electromyographic bursts, and also the clinical improvement with clonazepam but not beta blockers or mysoline, and the lack of a family history of ET provide support that OT is distinct from ET.

Aged

Spontaneous resolution of subdural hematoma. MRI findings.

A 33-year-old man suffered a traumatic subdural hematoma with complete spontaneous resolution, as demonstrated by computed tomography scanning and magnetic resonance imaging. After resolution, there was obliteration of the subarachnoid space on the affected side, giving rise to relative dilation of the subarachnoid space over the uninvolved convexity. A resolved subdural hematoma should be considered in the differential diagnosis of such an asymmetry.

Accidental Falls

Discordance between FDG uptake and technetium-99m-HMPAO brain perfusion in acute traumatic brain injury.

A 28-yr-old woman who sustained a mild traumatic brain injury had an 18F-fluorodeoxyglucose (FDG) PET brain study using coincidence imaging performed on a dual-head gamma camera (MCD version; ADAC, Milpitas, CA) followed 24 hr later by 99mTc-hexamethyl propyleneamine oxime SPECT brain perfusion imaging using a triple-head gamma camera (TRIONIX, Twinsburg, OH). The results of the SPECT brain perfusion study demonstrated decreased frontoparietal cortical brain perfusion, whereas 18F-FDG cerebral uptake was normal. Neuropsychological evaluation suggested frontal lobe involvement. This case demonstrates the possibility of discordance between brain perfusion and glucose uptake in acute mild traumatic brain injury.

Adult

Brain single-photon emission CT with HMPAO and safety of thrombolytic therapy in acute ischemic stroke. Proceedings of the meeting of the SPECT Safe Thrombolysis Study Collaborators and the members of the Brain Imaging Council of the Society of Nuclear Medicine.

BACKGROUND: To reliably identify patients at risk for symptomatic hemorrhagic transformation (SHT), future trials of thrombolysis for acute ischemic stroke might use a vascular imaging protocol applicable to a multicenter setting. The goal of this commentary is to address the safety of intravenous thrombolysis with the recombinant tissue plasminogen activator (rTPA) and potential solutions offered by single-photon emission CT (SPECT) as a noninvasive brain perfusion imaging modality. SUMMARY OF REVIEW: Even if patients with severe stroke, extensive ischemic changes on CT scan, advanced age, and high blood pressure are excluded from thrombolytic therapy, this cannot completely guarantee the safety of using rTPA. Brain SPECT scanning with hexamethylpropyleneamine-oxime (HMPAO) may help to screen out patients at risk if performed in addition to clinical and CT tests. The knowledge of pretreatment severity, extent, and location of ischemia might identify good versus poor responders to rTPA therapy. HMPAO-SPECT is widely available and feasible to perform without delaying rTPA therapy. Rigorous quality control and use of reproducible visual and semiquantitative methods of interpreting SPECT are necessary for implementation of SPECT technology in multicenter clinical trials. CONCLUSIONS: The major obstacle to general acceptance of thrombolytic therapies and rTPA in particular is the fear of symptomatic hemorrhagic transformation, and because HMPAO-SPECT might reliably identify patients at high risk of symptomatic hemorrhagic transformation, the clinical value of HMPAO-SPECT in patient selection for thrombolysis during the first hours of acute ischemic stroke should be determined through a prospective clinical trial.

Acute Disease

The open ring. A new imaging sign in demyelinating disease.

Because demyelinating disease of the brain occasionally presents with large ring-enhancing lesions on computed tomography (CT) scans and magnetic resonance images (MRIs), the authors sought to determine whether the ring pattern differed from that found in other common brain lesions with ring enhancement. Published MRI and CT scans of patients with adrenoleukodystrophy (23), and multiple sclerosis or similar demyelinating disorders (21), as well as a variety of tumors (44) and infections (44) matched to the demyelinating lesions by year of publication, in which ring enhancement was evident, were photographed. Photographs without diagnostic identification were presented randomly to two independent observers. The observers rated the contrast enhancement pattern as (1) open ring, with enhancement in the border of the lesion abutting the white matter; (2) closed ring; or (3) uncertain. For all diagnostically certain cases (n = 112), inter-rater agreement was excellent (kappa = 0.75). As an average of the two reviewers, scans for 11 of 132 cases were read as uncertain; 89% of adrenoleukodystrophy cases, 41% of the multiple sclerosis cases, 3% of tumors, and 9% of infections were classified as having the open-ring pattern. Overall, 66% of demyelinating lesions had an open-ring pattern compared with 7% of the non-demyelinating lesions (chi2 = 41.2, p < 0.0001). An open-ring pattern of enhancement is more likely to be associated with demyelinating lesions than with nondemyelinating lesions.

Adrenoleukodystrophy

Single-photon emission computed tomography of the brain in acute mania and schizophrenia.

Single-photon emission computed tomography (SPECT) imaging with n-isopropyliodoamphetamine (IMP) was performed on 11 patients with bipolar mania, 21 acute schizophrenics, and 15 healthy control subjects. Subjects were evaluated with neuropsychological tests and psychiatric rating scales. SPECT brain studies were blindly evaluated to assess the degree of radiopharmaceutical uptake in three neuroanatomical regions of interest in each hemisphere. All the control subjects, 1 manic patient, and 1 schizophrenic patient had normal brain SPECT uptake patterns. The scans of all others were read as abnormal. Hypofrontality was noted in some schizophrenics and maniacs. A significant increase in tracer uptake in temporal lobes was observed in both patient groups, more prominently in the manic patients. Increased and decreased basal ganglia uptake was also observed in patients. Both manic and schizophrenic patients showed cortical tracer heterogeneity of varying degree. The patterns of cerebral SPECT uptake seen in these acute psychoses were not specific for a diagnosis, but may be associated with dimensions of psychopathology. Because the patterns are different from those seen in cerebrovascular disease and the dementias, they may prove to be helpful in differential diagnosis.

Adult

SPECT imaging of stroke.

Single-photon emission computed tomography (SPECT) is a helpful tool for the management of stroke patients. Brain perfusion SPECT can help differentiate an ischemic event from peri-ictal phenomena such as Todd's paresis. Initial data suggest that SPECT may be useful in prognosticating the likelihood of an early stroke after a transient ischemic attack and in distinguishing lacunar from cortical stroke. After an acute stroke, early SPECT depicts the area of ischemia with greater accuracy than either computed tomography or magnetic resonance imaging. When the perfusion defect is large, the likelihood of hemorrhagic complications or herniation increases. Reperfusion of an arterial territory after thrombolysis can be documented more conveniently with SPECT than with angiography. SPECT before and after the injection of acetazolamide has been used to assess the vascular reserve in patients with severe stenosis of the proximal vessels of the cerebrovascular tree. Combined with transcranial Doppler studies, SPECT is used to document ischemia after subarachnoid hemorrhage. It has also been used to assess the effect of arterial ligation intended to treat arteriovenous malformations or aneurysms on brain perfusion and to evaluate ischemia secondary to pressure from an intracranial hemorrhage.

Brain Ischemia

Viral infections of the brain.

Brain infections are generally well visualized by contrast-enhanced computed tomography or magnetic resonance imaging. However, these modalities are often unrevealing in the encephalopathy produced by the human immunodeficiency virus and in the early stages of herpes simplex encephalitis. Several studies have documented the greater sensitivity of perfusion single-photon emission computed tomography (SPECT) in human immunodeficiency virus encephalopathy. In herpes simplex encephalitis, a few case reports have documented that SPECT may depict increased perfusion in the characteristically involved temporal and other limbic structures when computed tomography and magnetic resonance imaging are normal.

AIDS Dementia Complex

Head trauma: use of SPECT.

Brain damage inflicted by head trauma may not be visible on computed tomography or magnetic resonance imaging. This is true not only for mild head trauma, but also for moderate and severe head trauma. Perfusion imaging with single-photon emission computed tomography has proved in several controlled studies to be more sensitive than either computed tomography or magnetic resonance imaging in detecting brain abnormalities in patients with head trauma.

Brain Injuries

Astasia and gait failure with damage of the pontomesencephalic locomotor region.

Although there is evidence in experimental animals of the importance of the pedunculopontine area in locomotion, clinical lesion reports are lacking. An 83-year-old woman became unable to stand and to generate stepping movements after a hemorrhage at the pontomesencephalic junction involving the right pedunculopontine area. Her deficit resembled the gait failure present in some elderly individuals.

Aged

Early single-photon emission computed tomography in mild head trauma. A controlled study.

Although computed tomography (CT) and magnetic resonance imaging scans often appear normal after mild head trauma, many patients experience attentional or other cognitive disturbances that are difficult to quantify by neuropsychological testing in the absence of a premorbid profile. Within 2 days of mild head trauma, 14 patients with normal-appearing brain CTs were studied with single-photon emission computed tomography (SPECT). They were compared to 15 normal control subjects and to 12 patients with mild human immunodeficiency virus (HIV) encephalopathy. Ten of 14 head trauma patients were separated from the normal control subjects by both independent readers, blinded to the clinical diagnosis. None of the SPECT results from normal control subjects were "read" as trauma. Trauma could not be differentiated from HIV encephalopathy. The observed percentage agreement between raters was 0.83 (kappa = 0.72). SPECT is more sensitive than CT in detecting brain injury after mild head trauma.

AIDS Dementia Complex

Brain single-photon emission computed tomography.

Single-photon emission computed tomography (SPECT) provides cost-effective information on regional cerebral perfusion and, indirectly, on regional cerebral metabolism. Its ease of use facilitates the application of SPECT in clinical neurology. SPECT is emerging as a useful tool for the management of patients with stroke, epilepsy, recurrent brain neoplasms, and some forms of dementia. The applications being investigated, such as in vivo receptor labeling for benzodiazepines, serotonin, dopamine, and muscarinic receptors, may expand the clinical usefulness of this technique in the future.

Brain Death

The role of single photon emission computed tomography brain imaging with 99mTc-bicisate in the localization and definition of mechanism of ischemic stroke.

99mTc-bicisate (99mTc-ECD) is a new brain perfusion imaging agent formulated from a radiochemically stable kit (Neurolite). A multicenter trial was conducted to determine the sensitivity and specificity of single photon emission computed tomography (SPECT) imaging with 99mTc-bicisate in the localization of ischemic stroke; 170 subjects were enrolled, 128 patients with stroke and 42 controls. Imaging results from 148 subjects (107 stroke patients and 41 controls) were considered evaluable. In the evaluable subjects, SPECT brain imaging with 99mTc-bicisate (21.0 +/- 2.5 mCi) was interpreted without clinical information and was compared with a final assessment using all clinical, diagnostic, and laboratory procedures except the 99mTc-bicisate SPECT results. 99mTc-bicisate was safe and well-tolerated. SPECT imaging with 99mTc-bicisate demonstrated a specificity of 98% and a sensitivity of 86% for localization of strokes (kappa, 0.75; 95% confidence interval, 0.64-0.86). Results were unchanged over time and were similar for all stroke mechanisms except for lacunar disease (sensitivity, 58%). In a secondary analysis, a normal image or small, deep (e.g., subcortical) perfusion defect was highly predictive of a lacunar mechanism. Defects involving the cortical surface were strongly associated with nonlacunar mechanisms. SPECT imaging with 99mTc-bicisate is a sensitive marker in the localization of perfusion defects associated with ischemic stroke and may assist in the determination of the underlying mechanism of a stroke.

Adult

Vascular dementia: diagnostic criteria for research studies. Report of the NINDS-AIREN International Workshop.

Criteria for the diagnosis of vascular dementia (VaD) that are reliable, valid, and readily applicable in a variety of settings are urgently needed for both clinical and research purposes. To address this need, the Neuroepidemiology Branch of the National Institute of Neurological Disorders and Stroke (NINDS) convened an International Workshop with support from the Association Internationale pour la Recherche et l'Enseignement en Neurosciences (AIREN), resulting in research criteria for the diagnosis of VaD. Compared with other current criteria, these guidelines emphasize (1) the heterogeneity of vascular dementia syndromes and pathologic subtypes including ischemic and hemorrhagic strokes, cerebral hypoxic-ischemic events, and senile leukoencephalopathic lesions; (2) the variability in clinical course, which may be static, remitting, or progressive; (3) specific clinical findings early in the course (eg, gait disorder, incontinence, or mood and personality changes) that support a vascular rather than a degenerative cause; (4) the need to establish a temporal relationship between stroke and dementia onset for a secure diagnosis; (5) the importance of brain imaging to support clinical findings; (6) the value of neuropsychological testing to document impairments in multiple cognitive domains; and (7) a protocol for neuropathologic evaluations and correlative studies of clinical, radiologic, and neuropsychological features. These criteria are intended as a guide for case definition in neuroepidemiologic studies, stratified by levels of certainty (definite, probable, and possible). They await testing and validation and will be revised as more information becomes available.

Brain