Search PubMed⌕ Search

Biomedical subjects

J C Behiri

Publications and source records attributed to J C Behiri.

8 recordsLinked to original sources

Effect of triphenyl bismuth on glass transition temperature and residual monomer content of acrylic bone cements.

Self-curing acrylic bone cements are widely used in the fixation of prosthetic implants in orthopaedic surgery. Commercial bone cements are rendered radiopaque by the addition of heavy metal salts of barium and zirconia. The addition of barium sulphate adversely affects the mechanical strength and fracture toughness of bone cement and despite the fact that it has low solubility in water; its slow release and subsequent toxicity have caused concern. In an earlier study triphenyl bismuth (TPB) was found to be a viable alternative as a radiopaque agent in acrylic bone cements, which provided enhanced homogeneity. In this study we report the effect of the inclusion of TPB on the thermal properties of PMMA-based bone cements using both conventional DSC and Modulated Temperature DSC. Furthermore, analysis of the residual monomer contents is reported analysed by NMR spectroscopy in order to ascertain the influence of TPB on the polymerisation reaction. The glass transition temperature (Tg) determined by DSC showed that the values decreased with the addition of increasing amounts of TPB through both blending and dissolution methods; however, the method of incorporating TPB did not influence Tg. The magnitude of reduction was dependent of the amount of TPB and was greatest in the case of highest concentration of TPB used. A TPB melting peak was observed in the 25 wt% TPBBC, suggesting a limit to the solubility of TPB. The residual monomer analysis showed that at 10 and 15% by weight of TPB in the cement caused no significant changes in the residual monomer content but 25 wt% of TPB exhibited a significantly higher residual monomer content.

Calorimetry, Differential Scanning↗

Radiopacity in bone cements using an organo-bismuth compound.

In a joint replacement surgery it is vital for bone cement to be radiologically detectable. Consequently, heavy metal salts of barium and zirconia are incorporated as a contrast medium for this purpose. The addition of such particulate additives, however, can be detrimental to some of the physical, mechanical and biological properties. The present study reports the feasibility of using an organo-bismuth compound, namely. triphenyl bismuth (TPB) as a radiopaque agent for orthopaedic bone cements. TPB was incorporated in the bone cement matrix by two methods, (i) blending: TPB was added to the polymer phase of the bone cement and (ii) dissolution: by dissolving TPB in the monomer phase methylmethacrylate. The results showed that the inclusion of TPB at concentrations of 15% and 25% by weight of the polymer, in the bone cement matrix did not affect the polymerisation exotherm temperature and setting time. Furthermore, the addition of TPB via the dissolution method provided a statistically significant increase in the strain to failure in comparison to commercial acrylic cements containing barium sulphate, thus reducing the brittleness of the cement. The detrimental effects on the mechanical properties post conditioning in water, was also much less pronounced in the homogeneous TPB cements in comparison to barium sulphate containing cements. These observations can be attributed to the formation of a homogeneous and continuous matrix of the resultant bone cement with a much lower porosity.

Bismuth↗

Crack growth resistance in cortical bone: concept of microcrack toughening.

The role of microcracking in cortical bone as a toughening mechanism has been investigated in conjunction with the variation in fracture toughness with crack length. Fracture toughness tests were conducted on miniaturised compact tension specimens made from human and bovine cortical bone and the resultant microstructural damage, present in the form of microcracking on the surface, was analysed around the main propagating crack. It was found that the fracture toughness (Kc) and the cumulative number of microcracks increased linearly with crack extension in human and bovine cortical bone, although both Kc and number of microcracks were considerably higher in the latter case. Based on these results, a mechanism, derived from the resistance (R) curve concept developed for microcracking brittle solids, is proposed to explain the fracture of cortical bone, with microcracking distributed between a frontal process zone and a significant process zone wake. Evidence to support this mechanism is given from the existing bone literature, detailed scanning electron microscopical observations and the distribution of microcracks in the process zone wake.

Adult↗

The response of equine cortical bone to loading at strain rates experienced in vivo by the galloping horse.

The behaviour of cortical bone under load is strain rate-dependent, i.e. it is dependent on the rate at which the load is applied. This is particularly relevant in the galloping horse since the strain rates experienced by the bone are far in excess of those recorded for any other species. In this study the effect of strain rates between 0.0001 and 1 sec-1 on the mechanical properties of equine cortical bone were assessed. Initially, increasing strain rates resulted in increased mechanical properties. Beyond a critical value, however, further increases in strain rate resulted in lower strain to failure and energy absorbing capacity. This critical rate occurred around 0.1 sec-1 which is within the in vivo range for a galloping racehorse. Analysis of the stress-strain curves revealed a transition in the type of deformation at this point from pseudo-ductile to brittle. Bones undergoing brittle deformation are more likely to fail under load, leading to catastrophic fracture and destruction of the animal.

Animals↗

Fracture mechanics of bone with short cracks.

Tensile fracture experiments were performed upon specimens of wet mature bovine Haversian bone, with short, controlled notches. Stress concentration factors were found to be significantly less than values predicted using a maximum stress criterion in the theory of elasticity. Results were also modeled with the aid of linear elastic fracture mechanics. Agreement of experiment with theory was better in this case, however deviations were seen for short notches. Two mechanisms were evaluated for the behavior: plasticity near the crack tip, and effects of the Haversian microstructure, modelled by Cosserat elasticity, a generalized continuum theory. Plastic zone effects were found to be insignificant. Cosserat elasticity, by contrast, predicted stress concentration factors which better approximated observed values. To explore strain redistribution processes, further experiments were conducted upon notched specimens in torsion at small strain. They disclosed a strain redistribution effect consistent with Cosserat elasticity. These microelastic effects were attributed to the Haversian architecture of bone. The implications of the results are that bone resists the effect of stress raisers such as fatigue microcracks and surgical sawcuts to a much greater extent than anticipated on the basis of its elastic or elastoplastic properties.

Animals↗

Orientation dependence of the fracture mechanics of cortical bone.

The fracture mechanics parameter of the critical stress intensity factor (Kc) was determined by a modified compact tension test method, for the fracture of bovine tibia cortical bone at orientations of 0 degrees, 15 degrees, 30 degrees, 45 degrees, 75 degrees and 90 degrees to the bone axis. It was established that, for a given loading rate, a variation in orientation from 0-90 degrees produced average increases in Kc from 3.2 to 6.5 MN m-3/2.

Animals↗

Fracture mechanics of bone--the effects of density, specimen thickness and crack velocity on longitudinal fracture.

The fracture mechanics parameters of critical stress intensity factor (Kc) and critical strain energy release rate (Gc) for longitudinal fracture of bovine tibia cortical bone were determined by the compact tension method. It was demonstrated that, for a given bone density, Kc and Gc depended on the loading rate, and resultant crack velocity, with a maximum in fracture toughness (Kc approximately 6.3 MNm-3/2, Gc approximately 2900 Jm-2) at a crack velocity approximately 10(-3) ms-1. For a given loading rate, or crack velocity, an increase in bone density, in the range from 1.92 to 2.02 Mgm-3, produced increases in Kc and Gc, but a variation in specimen thickness (from 0.5 to 2 mm) had no effect on the measured fracture mechanics parameters.

Animals↗