Search PubMed⌕ Search

Biomedical subjects

J Bussey

Publications and source records attributed to J Bussey.

5 recordsLinked to original sources

Why a large tip electrode makes a deeper radiofrequency lesion: effects of increase in electrode cooling and electrode-tissue interface area.

INTRODUCTION: Increasing electrode size allows an increase in radiofrequency lesion depth. The purpose of this study was to examine the roles of added electrode cooling and electrode-tissue interface area in producing deeper lesions. METHODS AND RESULTS: In 10 dogs, the thigh muscle was exposed and superfused with heparinized blood. An 8-French catheter with 4- or 8-mm tip electrode was positioned against the muscle with a blood flow of 350 mL/min directed around the electrode. Radiofrequency current was delivered using four methods: (1) electrode perpendicular to the muscle, using variable voltage to maintain the electrode-tissue interface temperature at 60 degrees C; (2) same except the surrounding blood was stationary; (3) perpendicular electrode position, maintaining tissue temperature (3.5-mm depth) at 90 degrees C; and (4) electrode parallel to the muscle, maintaining tissue temperature at 90 degrees C. Electrode-tissue interface temperature, tissue temperature (3.5- and 7.0-mm depths), and lesion size were compared between the 4- and 8-mm electrodes in each method. In Methods 1 and 2, the tissue temperatures and lesion depth were greater with the 8-mm electrode. These differences were smaller without blood flow, suggesting the improved convective cooling of the larger electrode resulted in greater power delivered to the tissue at the same electrode-tissue interface temperature. In Method 3 (same tissue current density), the electrode-tissue interface temperature was significantly lower with the 8-mm electrode. With parallel orientation and same tissue temperature at 3.5-mm depth (Method 4), the tissue temperature at 7.0-mm depth and lesion depth were greater with the 8-mm electrode, suggesting increased conductive heating due to larger volume of resistive heating because of the larger electrode-tissue interface area. CONCLUSION: With a larger electrode, both increased cooling and increased electrode-tissue interface area increase volume of resistive heating and lesion depth.

Animals↗

The psychosocial issues of women serving time in jail.

Two hundred and one randomly selected female inmates incarcerated at a municipal jail were interviewed to establish the needs of this population and to formulate appropriate rehabilitative interventions. Measures of social support for this sample were uniformly low. Scores on the Global Severity Index of the Brief Symptom Inventory showed that 64 percent of the women were in the clinical range for mental health problems. Scores obtained from the Short Drug Abuse Screening Test indicated that 83 percent of the women were in the substance abuse range. When child and adult sexual abuse were combined, 81 percent of the women had been sexually victimized at some time in their lives. The data point to the need for improved programs and conditions within penal settings and for intermediate sanctions for nonviolent female offenders. Such sanctions could include both correctional day treatment and community-based correctional living sites.

Adult↗

Double aortic arch.

Explore the source record for details and available documents.

Airway Obstruction↗