Search PubMed⌕ Search

Biomedical subjects

J Britto

Publications and source records attributed to J Britto.

38 records · Page 3Linked to original sources

Effect of pirenzepine on oesophageal, gastric, and enteric motor function in man.

The effect of pirenzepine on oesophageal, gastric, and enteric motor function was evaluated in six healthy volunteers. Each subject was studied before and after taking pirenzepine, 100 mg/day, for 3 days. Half and complete gastric emptying times of clear liquid, assessed by epigastric impedance, were significantly delayed by the drug: 6.16 +/- 1.74 min and 13.8 +/- 4.64 min versus 16.65 +/- 3.03 min and 25.1 +/- 8.2 min, respectively (p less than 0.05). Enteric motility was assessed by manometry, and variables studied were the duration of the various phases of the migratory motility complex, the frequency of contractions in phase III, and the amplitude of contractions in phases II, III, and in the postprandial period. Only phase I was affected and was significantly prolonged by the drug: 16.08 +/- 5.94 min versus 31.65 +/- 12.88 min (p less than 0.01). Oesophageal motility was assessed by manometry. Variables studied were amplitude and duration of contractions in the body of the oesophagus, and lower oesophageal sphincter pressure. Results were not significantly changed by the drug. We conclude that pirenzepine, given at a dose used for treatment of peptic ulcer disease, significantly delays the gastric emptying of liquids, has minimal effect on enteric motility, and has no effect on oesophageal motility. The effect on gastric emptying may be therapeutically useful by reducing the acid load on the duodenum in duodenal ulcer disease.

Adult↗

Noninvasive measurement of cardiac output in critically ill children.

This study was performed to evaluate the hemodynamic status of children admitted to the intensive care unit, using suprasternal and transesophageal Doppler ultrasound, and to establish a suitable noninvasive technique to monitor trends in cardiac output in critically ill children. Twenty children were studied over a period of 6 months. The median age was 32.5 months and weight 14.5 kg. Minute distance (MD), which is a linear cardiac output parameter, was assessed. Seven simultaneous pairs of measurements of MD were made using transesophageal Doppler (TED) and suprasternal Doppler (SSD) by the same operator. Following a fluid challenge, seven repeat pairs of measurements were made. The mean percentage changes for MD by TED and SSD were 21.84 (SD 9.97) and 5.75 (SD 7.32). The average coefficients of variation for measurements of MD by TED and SSD were 2.34% and 15.98%, respectively. The mean difference in percentage change between MD, measured by TED and SSD, was 27.59 with a 95% confidence interval and wide limits of agreement. The repeatability of TED measurements was good, but the measurements by SSD were wide and erratic with poor reproducibility. Our study shows that TED is easy to use, reliable, and very useful for monitoring hemodynamic changes in critically ill children.

Adolescent↗