Search PubMed⌕ Search

Biomedical subjects

J Bonn

Publications and source records attributed to J Bonn.

42 records · Page 3Linked to original sources

Evaluation of a new percutaneous stainless steel Greenfield filter.

PURPOSE: To evaluate a new percutaneous Greenfield filter with an alternating hook design and over-the-wire delivery system. MATERIALS AND METHODS: The alternating hook stainless steel Greenfield filter was evaluated in a prospective clinical trial between March 10, 1994, and January 27, 1995. Filters were placed in 75 patients in nine clinical centers and follow-up with radiographs and ultrasound scans was carried out at 30 days. RESULTS: Clinical trial results revealed successful placement in all patients. There were four cases of filter limb asymmetry (5.3%) without clinical sequelae, with one incidence of failure to span the cava. No significant migration was found. There were no clinically suspected pulmonary emboli, but one instance of probable caval penetration (1.7%) did occur. Caval occlusion was documented in three patients (5%). CONCLUSION: The percutaneous stainless steel Greenfield filter provides ease of insertion and improved deployment while maintaining the high standards of efficacy and safety associated with the standard and titanium Greenfield filters.

Adult↗

1998 SCVIR Gary J. Becker Young Investigator Award. Endovascular repair of arterial pseudoaneurysms with use of a perfusion balloon catheter.

PURPOSE: Pseudoaneurysms represent contained disruption of the arterial wall. Iatrogenic pseudoaneurysms frequently complicate complex endovascular procedures. With use of an animal model, the authors attempted to determine the safety and efficacy of using a perfusion balloon catheter (PBC) to thrombose surgically created pseudoaneurysms. MATERIALS AND METHODS: An in vitro system measured maximum flow volume through a 5-F PBC. Pseudoaneurysms were created in domestic swine with use of a jugular vein patch anastomosed to a femoral arteriotomy. The PBC was inflated across the pseudoaneurysm neck for 30-minute intervals until thrombosis was confirmed by ultrasound. Completion arteriography was performed to evaluate for vascular complications. RESULTS: Maximum flow through the PBC was 62.6 mL/min measured at a constant pressure gradient of 120 mm Hg. Five pseudoaneurysms were created in four animals. The PBC completely thrombosed all five lesions. The mean treatment duration was 129 minutes (+/- 39 minutes SD). No native arterial injury, in situ thrombus, or distal embolization occurred. Partial recanalization of three of the five treated pseudoaneurysms was identified on follow-up arteriography and gross sectioning (n = 2 and n = 1, respectively). CONCLUSION: The PBC safely and effectively thrombosed surgically created pseudoaneurysms. Partial recanalization of treated pseudoaneurysms was demonstrated. Clinical trials are warranted.

Aneurysm, False↗

Comparison of conventional angioplasty with the Palmaz stent in the treatment of abdominal aortic stenoses from the STAR registry. SCVIR Transluminal Angioplasty and Revascularization.

PURPOSE: To retrospectively compare the safety and short-term efficacy of conventional percutaneous transluminal angioplasty (PTA) and PTA with the Palmaz balloon-expandable intravascular stent for the treatment of infrarenal abdominal aortic atherosclerotic stenoses. PATIENTS AND METHODS: The records of 25 patients with infrarenal aortic stenoses treated by means of percutaneous techniques were retrieved from the SCVIR Transluminal Angioplasty and Revascularization (STAR) Registry and analyzed. Thirteen patients were treated with PTA alone and 12 were treated with the Palmaz intravascular stent. RESULTS: Technical success was achieved in 92% of patients treated with PTA alone and in 100% of those treated with the Palmaz stent. Significant improvements in lesion morphology, hemodynamics, clinical status, and ankle arm indexes were shown in both groups. There was no statistically significant difference in percent stenosis reduction, decrease in trans-stenotic gradient, or initial clinical outcome between the group treated by means of PTA and the group treated by means of PTA with the Palmaz stent. CONCLUSIONS: PTA and intravascular stent placement of atherosclerotic stenoses involving the infrarenal aorta are both safe and efficacious therapeutic modalities. At present, it does not appear that primary stent placement confers any short-term benefits over technically successful PTA in aortic stenoses.

Adult↗

Intravascular ultrasound as an alternative to positive-contrast vena cavography prior to filter placement.

PURPOSE: In a nonconsecutive series of patients, intravascular ultrasound (IVUS) was investigated for safety and efficacy as an alternative to positive-contrast vena cavography for evaluating the inferior vena cava (IVC) prior to filter placement. MATERIALS AND METHODS: In a 6.5-year period, 30 patients (15 women, 15 men) ranging in age from 22 to 98 years old (mean, 56 years) underwent vena cava filter placement without conventional positive-contrast vena cavography, after IVUS evaluation of the IVC with use of a 6.2-F, 12.5- or 20-MHz monorail catheter system. The rationale for using IVUS included contraindications to iodinated contrast material in 14 patients with renal insufficiency and in four patients with previous life-threatening anaphylactoid reaction to iodinated contrast material; limitations to radiation exposure in four pregnant patients; and inability to otherwise image the IVC of eight morbidly obese patients who exceeded the weight limits of available angiographic equipment. IVUS completely replaced positive-contrast vena cavography, although not fluoroscopy in the four pregnant patients and in the 18 patients with contrast material contraindications. In two of the eight obese patients, IVUS was the only imaging modality. RESULTS: In all 30 patients, IVUS successfully determined the patency of the filter delivery route veins and the vena cava, the absence of thrombus, the location of renal veins, the absence of anatomical variants, and the vena cava diameter at the desired filter deployment level. Successful filter placement was confirmed in all 30 patients either with plain film alone (n = 12), IVUS alone (n = 3), computed tomography alone (n = 1), external ultrasound alone (n = 1), IVUS and another imaging modality (n = 10), or by combinations of other imaging modalities (n = 3). There were no complications. CONCLUSIONS: IVUS is a safe and effective alternative to conventional positive-contrast vena cavography for imaging the IVC prior to filter placement in patients with contraindications to iodinated contrast material or ionizing radiation.

Adult↗

In vivo NMR imaging of tissue sodium in the intact cat before and after acute cerebral stroke.

The first in vivo nuclear magnetic resonance (NMR) images of tissue sodium in the intact animal are presented. The distribution of sodium in the normal cat's head is described. An experimental stroke was surgically induced. Sodium NMR imaging showed a pronounced focal increase in cerebral sodium concentration 9 hr after ligation of the middle cerebral artery. The method appears to be very sensitive for early detection of infarction. The measured increase in the regional sodium NMR signal probably reflects both a true increase in concentration of brain sodium and an increased NMR visibility of the sodium nucleus in the region of the infarction.

Animals↗