Search PubMed⌕ Search

Biomedical subjects

J B Kruskal

Publications and source records attributed to J B Kruskal.

At least 19 recordsLinked to original sources

Radio-frequency thermal ablation with NaCl solution injection: effect of electrical conductivity on tissue heating and coagulation-phantom and porcine liver study.

PURPOSE: To characterize the effects of NaCl concentration on tissue electrical conductivity, radio-frequency (RF) deposition, and heating in phantoms and optimize adjunctive NaCl solution injection for RF ablation in an in vivo model. MATERIALS AND METHODS: RF was applied for 12-15 minutes with internally cooled electrodes. For phantom experiments (n = 51), the NaCl concentration in standardized 5% agar was varied (0%-25.0%). A nonlinear simplex optimization strategy was then used in normal porcine liver (n = 44) to determine optimal pre-RF NaCl solution injection parameters (concentration, 0%-38.5%; volume, 0-25 mL). NaCl concentration and tissue conductivity were correlated with RF energy deposition, tissue heating, and induced coagulation. RESULTS: NaCl concentration had significant but nonlinear effects on electrical conductivity, RF deposition, and heating of agar phantoms (P<.01). Progressively greater heating was observed to 5.0% NaCl, with reduced temperatures at higher concentrations. For in vivo liver, NaCl solution volume and concentration significantly influenced both tissue heating and coagulation (P<.001). Maximum heating 20 mm from the electrode (102.9 degrees C +/- 4.3 [SD]) and coagulation (7.1 cm +/- 1.1) occurred with injection of 6 mL of 38.5% (saturated) NaCl solution. CONCLUSION: Injection of NaCl solution before RF ablation can increase energy deposition, tissue heating, and induced coagulation, which will likely benefit clinical RF ablation. In normal well-perfused liver, maximum coagulation (7.0 cm) occurs with injection of small volumes of saturated NaCl solution.

Animals↗

Impact of multidetector CT on donor selection and surgical planning before living adult right lobe liver transplantation.

OBJECTIVE: This study was performed to document the impact of multidetector multiphase CT in facilitating patient selection and surgical planning in potential donors being evaluated for living adult right lobe liver transplantation. SUBJECTS AND METHODS: Forty consecutive potential donors were included in the study. There were 26 men and 14 women, (age range, 18-57 years; mean, 37 years) We performed CT using a multidetector scanner, after IV injection of 180 mL of contrast material at 5 mL/sec. Arterial phase images were acquired at 18 sec (collimation, 1.25 mm; table speed, 7.5) and portal phase images, at 60 sec (collimation, 2.5 mm; table speed, 15). Postprocessing was performed on a commercially available workstation. CT data included dual-energy assessment of liver parenchyma for fatty infiltration; depiction of arterial, portal venous, and hepatic venous anatomy and identification of important vascular variants; and determination of total and lobar liver volume. RESULTS: Of the 40 potential liver donors evaluated, 15 patients (37.5%) were excluded on the basis of CT findings, with most exclusions a result of portal vein anomalies (n = 8). Fatty infiltration resulted in four exclusions (10%), and small liver volume resulted in three exclusions (7.5%). CONCLUSION: Multidetector multiphase CT provided comprehensive parenchymal, vascular, and volumetric preoperative evaluation of potential donors undergoing living adult right lobe liver transplantation. This information had a major impact on patient selection because it was used to stratify patients. It allowed the surgeons to plan their surgical approach, and this planning may reduce postoperative complications.

Adolescent↗

Accuracy of volumetric measurements after virtual right hepatectomy in potential donors undergoing living adult liver transplantation.

OBJECTIVE: The purpose of this study was to evaluate accuracy for determining the total and lobar liver volumes using a multidetector CT scanner in potential donors undergoing living adult right lobe liver transplantation. SUBJECTS AND METHODS: Fifty-two adult donors underwent CT using a multidetector scanner after IV injection of 180 mL of contrast material. For volumetric determination, portal venous phase images were acquired at 60 sec. Hand-tracing was used to isolate the entire liver, and a curved hepatectomy plane was then identified in a manner simulating the surgical incision. Two observers performed hand-tracing of the entire liver to calculate total liver volume, and of the right lobe to calculate expected graft volume. RESULTS: The mean volume of the entire liver, right lobe, and left lobe was 1807 mL, 990 mL, and 817 mL, respectively, for observer 1, and 1788 mL, 1007 mL, and 781 mL, respectively, for observer 2. There was significant agreement between the two observers in determining total and lobar liver volumes (r = 0.996, 0.977, and 0.965 for total, right lobe, and left lobe volumes, respectively; p< 0.0001). There was no statistically significant difference between the two observers in measuring total or lobar liver volumes (p< 0.0001). There was significant agreement between right lobe volume measured by each observer and graft weight obtained in 14 donors at surgery (r = 0.898 and 0.879, for observers 1 and 2, respectively; p <0.001). CONCLUSION: Total and lobar volume determinations after virtual right hemihepatectomy provides accurate and reproducible information that is critical in selecting potential living liver donors.

Adolescent↗

State-of-the-art ultrasonography is as accurate as helical computed tomography and computed tomographic angiography for detecting unresectable periampullary cancer.

OBJECTIVE: To compare the ability of state-of-the-art ultrasonography with that of helical computed tomography and computed tomographic angiography in detecting unresectable periampullary cancer. In most patients periampullary cancer is unresectable because of either distant metastasis or local vascular involvement. The advent of gray scale and color Doppler ultrasonography has improved the ability of ultrasonography to detect vascular involvement. METHODS: Twenty-three consecutive patients with periampullary cancer were enrolled for prospective staging of their disease by comparing helical computed tomography and computed tomographic angiography with gray scale and color Doppler ultrasonography of the abdomen. Portal vein, superior mesenteric vein, splenic vein, and superior mesenteric artery involvement was graded 0 to 4, grade 0 being no vascular involvement and grade 4 being total occlusion of the vessel. Agreement between ultrasonography and computed tomographic angiography for determining vascular involvement was measured by chi2 analysis. RESULTS: Two patients (9%) were excluded because excessive overlying bowel gas hampered the ability of ultrasonography to visualize the pancreas. For the remaining 21 patients, there was significant agreement between ultrasonography and computed tomographic angiography for detecting vascular involvement in all vessels (P < .001; portal vein, kappa = 0.67; superior mesenteric vein, kappa = 0.67; splenic vein, kappa = 0.85; and superior mesenteric artery, kappa = 0.59). Ultrasonography was in agreement with computed tomographic angiography in all cases of unresectability. Both modalities were equally poor in preoperatively showing lymphadenopathy and metastases. CONCLUSIONS: Provided that there is adequate visualization on ultrasonography of the head of the pancreas in the periampullary region, then state-of-the-art gray scale and color Doppler ultrasonography are as accurate as helical computed tomography and computed tomographic angiography for detecting the unresectability of periampullary cancer. If performed as the initial investigation and the region of the pancreatic head is clearly shown, and if vascular encasement or occlusion or distant metastasis is identified, further investigations are unnecessary.

Adult↗

Role of virtual computed tomographic colonography in patients with colorectal cancers and obstructing colorectal lesions.

PURPOSE: The aim of this study was to assess the ability of computed tomographic colonography to diagnose colorectal masses, stage colorectal cancers, image the proximal colon in obstructing colorectal lesions, and evaluate the anastomoses in patients with previous colorectal surgery. METHODS: We prospectively performed computed tomographic colonography examinations in 34 patients (20 males; mean age, 64.2; range, 19-91 years): 20 patients had colorectal masses (defined at endoscopy as intraluminal masses 2 cm or larger), 7 patients had benign obstructing colorectal strictures, and 7 patients had a prior colorectal resection. Final tumor staging was available in all 16 patients who had colorectal cancers and 15 patients were referred after incomplete colonoscopy. The ability of computed tomographic colonography to stage colorectal cancers, identify synchronous lesions in patients with colorectal masses, and image the proximal colon in patients with obstructing colorectal lesions was assessed. RESULTS: Computed tomographic colonography identified all colorectal masses, but overcalled two masses in patients who were either poorly distended or poorly prepared. Computed tomographic colonography correctly staged 13 of 16 colorectal cancers (81 percent) and detected 16 of 17 (93 percent) synchronous polyps. Computed tomographic colonography over-staged two Dukes Stage A cancers and understaged one Dukes Stage C cancer. A total of 97 percent (87/90) of all colonic segments were adequately visualized at computed tomographic colonography in patients with obstructing colorectal lesions compared with 60 percent (26/42) of segments at barium enema (P < 0.01). Colonic anastomoses were visualized in all nine patients, but in one patient, computed tomographic colonography could not distinguish between local tumor recurrence and surgical changes. CONCLUSION: Computed tomographic colonography can accurately identify all colorectal masses but may overcall stool as masses in poorly distended or poorly prepared colons. Computed tomographic colonography has an overall staging accuracy of 81 percent for colorectal cancer and is superior to barium enema in visualizing colonic segments proximal to obstructing colorectal lesions.

Adult↗

Hepatic colon cancer metastases in mice: dynamic in vivo correlation with hypoechoic rims visible at US.

PURPOSE: To use videomicroscopy of tumor-bearing livers of live mice to depict tumors directly to determine the exact nature of rims seen on corresponding ultrasonographic (US) scans. MATERIALS AND METHODS: Seventy-six hepatic colorectal cancer metastases were studied in exteriorized livers of 18 mice by using intravital microscopy, US, and histologic examination of the same tumors. RESULTS: Hypoechoic rims correlated with distended sinusoidal spaces in vivo. These spaces surrounded only locally invasive tumors (mean diameter, 0.85 mm) that had obstructed the supplying terminal portal venules. These spaces, containing adherent leukocytes and tumor cells, gave rise to new tumor vasculature. Results of histologic examination of rims (portal inflammation, congested or compressed sinusoids, cell atrophy) correlated with leukocyte endothelial adherence, occluded sinusoids, and new vessel formation in vivo. CONCLUSION: Unlike results from previous studies, dynamic in vivo observations of peritumoral rims demonstrated distended sinusoidal spaces giving rise to new tumor-penetrating vessels. These sinusoids arose around locally invasive tumors and were associated with more advanced intrahepatic disease. These dynamic observations provide a pathophysiologic explanation for previous histologic correlates of peritumoral rims.

Analysis of Variance↗

Percutaneous tumor ablation: increased coagulation by combining radio-frequency ablation and ethanol instillation in a rat breast tumor model.

PURPOSE: To determine if percutaneously applied radio frequency (RF) combined with percutaneous ethanol instillation (PEI) can increase the extent of ablation in rat breast tumors. MATERIALS AND METHODS: R3230 mammary adenocarcinoma was implanted bilaterally in the mammary fat pads of 18 female rats. The tumor nodules measured 1. 2-1.5 cm. Eight tumors each were treated with (a) conventional, monopolar RF (96 mA +/- 28; 70 degrees C for 5 minutes); (b) PEI (250 microL of ethanol infused over 1 minute); (c) combined therapy of PEI immediately followed by RF ablation; or (d) combined therapy of RF ablation immediately followed by PEI. Four tumors were not treated and served as controls. Histopathologic examination included staining for mitochondrial enzyme activity. Resultant coagulation necrosis was compared between treatment groups. RESULTS: Coagulation necrosis was observed only within treated tumors. Tumors treated with RF alone had 6.7 mm +/- 0.6 of coagulation surrounding the electrode, and those treated with PEI alone had 6.4 mm +/- 0.6 of coagulation around the instillation needle (not significant). Significantly increased coagulation of 10.1 mm +/- 0.9 (P: <.001) was observed with the combined therapy of PEI followed by RF. RF followed by PEI did not increase coagulation (6.4 mm +/- 0.8 around the needle; not significant). CONCLUSION: PEI followed by RF ablation therapy increases the extent of induced coagulation necrosis in rat breast tumors, as compared with either therapy alone.

Administration, Cutaneous↗

Utility of intravenously administered contrast material at CT colonography.

PURPOSE: To determine if intravenously administered contrast material improves overall reader confidence in the assessment of the colon, large-bowel wall conspicuity, and diagnostic accuracy in the detection of colorectal polyps and cancers at computed tomographic (CT) colonography. MATERIALS AND METHODS: Two hundred patients underwent CT colonography in both supine and prone positions. A five-point scale was used to assess the effect of contrast enhancement on overall reader confidence and bowel wall conspicuity. Eighty-one patients underwent CT colonography with complete colonoscopic or surgical correlation; diagnostic accuracy was compared in 48 patients who received contrast material and 33 who did not. RESULTS: Bowel preparation was ideal in 38 (19%) of 200 patients. Enhanced prone CT images had significantly better scores for reader confidence (4.9 +/- 0.1 vs 4.6 +/- 0.1, P: <.005) and bowel wall conspicuity (4.6 +/- 0.2 vs 4.2 +/- 0.2, P: <.005) compared with those of nonenhanced prone images despite no significant difference in bowel distention (3.8 +/- 0.2 vs 3.9 +/- 0. 1, P: =.8). Enhancement significantly improved the ability to depict medium (6-9-mm) polyps (75% vs 58%, P: <.05). Three large (10-19-mm) polyps were detected only with contrast enhancement; two remained submerged despite dual positioning. CONCLUSION: The use of intravenously administered contrast material significantly improved reader confidence in the assessment of bowel wall conspicuity and the ability of CT colonography to depict medium polyps in suboptimally prepared colons.

Adult↗

Radiologic features of complications arising from dropped gallstones in laparoscopic cholecystectomy patients.

OBJECTIVE: Because laparoscopic cholecystectomy has become the accepted treatment for symptomatic cholelithiasis, radiologists frequently encounter patients who have had this surgery. Although the radiologic features of postoperative bile duct injury are well documented, the imaging features of less well-known complications remain poorly described. One such unusual complication is abscess formation caused by dropped gallstones. CONCLUSION: Although the incidence of dropped gallstones is an uncommon complication of laparoscopic cholecystectomy, it should be recognized as a potential source of both intraabdominal and intrathoracic abscess formation in any patient presenting months to years after undergoing laparoscopic cholecystectomy. These abscesses are not necessarily confined to the right upper quadrant.

Abdominal Abscess↗

Staging of rectal cancer after polypectomy: usefulness of endorectal US.

PURPOSE: To determine the usefulness of endorectal ultrasonography (US) in staging rectal cancer discovered at polypectomy. MATERIALS AND METHODS: Before surgical resection, endorectal US was performed in 18 consecutive patients with adenocarcinoma discovered in polypectomy specimens. A rotating 7-10-MHz endoprobe with an inflatable balloon was used in all cases. The precise depth of penetration (T stage) was determined with endorectal US and correlated with the histopathologic findings. RESULTS: For detection of residual tumor after polypectomy, endorectal US had a sensitivity of 100%, specificity of 44%, positive predictive value of 64%, and negative predictive value of 100%. Although the precise T stage was correctly predicted with endorectal US in only eight patients (44%), endorectal US was able to demonstrate whether the tumor was limited to the bowel wall in 16 patients (89%). CONCLUSION: Endorectal US is an accurate technique for localizing tumors to or beyond the rectal wall in patients who have undergone diagnostic polypectomy. Although inaccuracies in determining the specific T stage may occur, endorectal US facilitates surgical planning in the vast majority of patients and should therefore remain the local staging technique of choice in this specific patient population.

Adenocarcinoma↗

Endoluminal CT colonography after an incomplete endoscopic colonoscopy.

OBJECTIVE: We evaluated the clinical usefulness of endoluminal CT colonography after an incomplete colonoscopy. SUBJECTS AND METHODS: We prospectively studied 40 patients in whom the cecum could not be reached endoscopically despite adequate bowel preparation. Endoluminal CT colonography (120 kVp, 120 mA, 3-mm collimation, pitch of 2, 1.5-mm interval reconstruction) was performed within 2 hr of incomplete colonoscopy. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal images were analyzed. Twenty-six patients (65%) underwent barium enema immediately after endoluminal CT colonography. We analyzed colonic distention; duration of endoluminal CT colonography; patient tolerance; number of colonic segments seen at colonoscopy, endoluminal CT colonography, and barium enema; and reasons for incomplete colonoscopy as well as colonic and extracolonic findings. RESULTS: Duration of endoluminal CT colonography was 14.2 +/- 4.6 min (mean +/- SD). Endoluminal CT colonography was better tolerated than colonoscopy or barium enema (p < .001). Probable causes for incomplete colonoscopy were identified at endoluminal CT colonography in 74% of 40 patients. Baseline colonic distention in the region of the transverse and right colon was considered adequate before additional air insufflation; however, the addition of air significantly enhanced colonic distention throughout the entire colon (p < .001). Endoluminal CT colonography adequately revealed 96% of all colonic segments; in comparison, barium enema adequately revealed 91% of all segments (p < .05). CONCLUSION: In patients with incomplete colonoscopy, endoluminal CT colonography successfully showed the previously unrevealed colon in more than 90% of patients. Endoluminal CT colonography is a rapid, well-tolerated technique that provides clinically useful colonic and extracolonic information and should be considered for all patients who undergo incomplete colonoscopy.

Adult↗

Chronic inflammatory pseudotumor arising in the hepatobiliary-pancreatic system: progressive multisystemic organ involvement in four patients.

OBJECTIVE: Inflammatory pseudotumor is a benign process that can involve most organ systems. The purpose of this report was to evaluate the imaging features of multifocal chronic inflammatory pseudotumor in four patients who presented with clinical, radiographic, and biopsy evidence of pancreatic or biliary malignancy. CONCLUSION: To our knowledge, this is the first report in the radiology literature describing the imaging features of progressive multifocal inflammatory pseudotumor originating from a primary pancreatic or biliary focus. Even on retrospective review, no distinguishing imaging features were identified that could discriminate benign from malignant disease. These findings emphasize the importance of histopathologic analysis in the diagnosis of malignancy, particularly in patients with previously diagnosed inflammatory pseudotumor.

Adult↗

Imaging of abdominal manifestations of melanoma.

Despite an increasing incidence of melanoma in this country, innovative new therapies are allowing patients to receive aggressive experimental treatments. Diagnostic imaging remains crucial for tumor staging and for follow-up of patients being treated with these protocols. Because metastases occur in the abdomen and pelvis in approximately 60% of patients, it is important to accurately identify all sites of tumor spread. A variety of imaging techniques are used to image these patients, with CT currently being used for staging purposes and to guide diagnostic biopsies. Other imaging techniques, such as MR, ultrasound, and fluoroscopy, are currently reserved for investigating specific complications of melanoma, such as vascular invasion, hemorrhage from a tumor, and small bowel involvement, including intussusception. Recently, whole body positron emission tomography (PET) imaging using 2-deoxy-2-fluoro-D-glucose (FDG) has been shown to be highly accurate in assessing patients with metastatic malignant melanoma. This review illustrates the spectrum of manifestations of metastatic melanoma throughout the abdomen and pelvis, including solid organ, hollow lumen, and retroperitoneal involvement, and demonstrates some of the typical and atypical manifestations that may be identified.

Abdominal Neoplasms↗

Liver metastases from colorectal cancer: drug delivery with liposome-encapsulated doxorubicin.

PURPOSE: To evaluate the intratumoral distribution of liposome-encapsulated doxorubicin. MATERIALS AND METHODS: Tumor-bearing livers of 24 mice were studied with in vivo fluorescence and electron microscopy after injection of liposomal doxorubicin in the hepatic artery, portal vein, or tail vein. Distribution and uptake of liposomes and doxorubicin in tumors were compared at 5, 30, and 60 minutes after injection. In vitro evaluation of uptake of doxorubicin in Kupffer cells and in human colorectal cancer cells incubated under normoxic and hypoxic conditions for 5, 30, and 60 minutes was performed with fluorescence microscopy. RESULTS: Doxorubicin autofluorescence was seen in tumors 30 minutes after intraarterial and intraportal injection and was statistically significantly greater at 60 minutes (P < .001). Liposomes were observed in small tumors (diameter < 300 microns) and were trapped in Kupffer cells around larger, hypovascular tumors. Electron microscopy findings confirmed intracytoplasmic, perinuclear uptake of liposomes in tumor cells. In vitro, a higher proportion of doxorubicin was seen in cancer cells (92%) than in Kupffer cells (75%) after 60 minutes incubation. CONCLUSION: Liposomal doxorubicin can be reliably delivered to liver metastases via the hepatic artery, eliminating need for tumor embolization. Further evaluation is warranted, and the drug may be useful for treating patients with unresectable liver metastases.

Animals↗