J Andrew Derbyshire

Publications and source records attributed to J Andrew Derbyshire.

10 recordsLinked to original sources

Partial field-of-view spiral phase-contrast imaging using complex difference processing.

Rapid flow imaging was achieved with a partial field of view (pFOV) spiral motion-encoded technique. The FOV and the acquisition time were reduced by a factor of 2 by undersampling k-space. The pFOV spiral k-space trajectory aliased signals from outside a circular ring whose radius was inversely proportional to the distance between adjacent spirals in k-space. In this study the FOV was adjusted so that all of the moving spins were located inside the inner half circle of the full FOV. Complex subtraction of two differentially flow-encoded images was used to remove the spurious phase sources and provide an accurate measurement of flow. The complex subtraction process also serves to eliminate aliasing artifacts that are generated by static tissue from outside the reduced FOV. Experiments in a flow phantom and volunteers showed that the flow estimates obtained by pFOV spiral motion encoding are in good agreement with the estimates reconstructed using complex difference processing.

Adult↗

Real-time blood flow imaging using autocalibrated spiral sensitivity encoding.

A novel spiral phase contrast (PC) technique was developed for high temporal resolution imaging of blood flow without cardiac gating. An autocalibrated spiral sensitivity encoding (SENSE) method is introduced and used to reconstruct PC images. Numerical simulations and a flow phantom study were performed to validate the technique. To study the accuracy of the flow measurement in vivo, a high-resolution cardiac experiment was performed and a subset of undersampled SENSE reconstructed data were reconstructed. Good agreement between the velocity measurement from the fully-sampled and undersampled data was achieved. Real-time experiments were performed to measure blood velocity in the ascending aorta and aortic valve, and during a Valsalva maneuver. The results demonstrate the potential of this technique for real-time flow imaging.

Algorithms↗

Single heartbeat cardiac tagging for the evaluation of transient phenomena.

Many cardiac abnormalities are of a transient nature, creating a beat-to-beat variation in myocardial function. This work presents the cardiac imaging technique for the measurement of regional function during transient cardiac phenomena. All information necessary for the reconstruction of a cine loop is acquired within a single heartbeat, avoiding the temporal blurring introduced by segmented imaging due to the assumption of cardiac cycle periodicity. This method incorporates a gradient-optimized, high-efficiency EPI-SSFP sequence and TSENSE parallel imaging. For acquisitions with readout resolutions of 128,160, 192, and 256 points, the technique produced images with average temporal resolution of 35, 39, 43, and 52 ms and average spatial resolutions of 2.65, 2.12, 1.77, and 1.32 mm in the readout direction, respectively, and 2.88 and 2.08 mm in the phase encode direction for acceleration rates of 3 and 4, respectively. Local apparent strains in the single slice and measurements of ventricular end-systolic and end-diastolic areas were used as quantitative measures to validate the single heartbeat technique. To demonstrate the utility of the sequence, movie loops were acquired for multiple heartbeats in non-breath-held acquisitions as well as during a Valsalva maneuver. A heartbeat-interleaved acquisition allowed for the reconstruction of nonaccelerated images from R contiguous heartbeats. Images reconstructed from such data displayed tag blurring and reduced tag persistence due to motion and inter-heartbeat variability. Images acquired during the Valsalva maneuver demonstrated apparent beat-to-beat variability, visible both in the images and as changing strain patterns and ventricular volumes.

Adult↗

Automatic in-plane rotation for doubly-oblique cardiac imaging.

PURPOSE: To develop and test a method for automatically calculating the in-plane rotation for doubly-oblique slice geometry in order to minimize wrap artifacts for a given FOV. MATERIALS AND METHODS: The equations for in-plane rotation were formulated for doubly-oblique imaging of a cylindrical body with elliptical cross-section. Based on this formulation, automatic in-plane rotation was implemented and tested on a commercial scanner using nominal values for ellipticity of the body. RESULTS: Short axis, doubly oblique, cardiac imaging were acquired with and without in-plane rotation. The desired in-plane rotation proved to be relatively insensitive to the ellipticity of the body, permitting an automatic solution based on a nominal value. CONCLUSION: In-plane rotation is desirable for doubly oblique imaging (e.g., cardiac applications), particularly for reduced-FOV accelerated imaging such as SENSE. The proposed method, which provides an approximate solution for automatic, in-plane rotation for doubly-oblique imaging, was demonstrated.

Artifacts↗

Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady-state free precession (SSFP) contrast. Active catheters and phased-array coils were used for combined imaging of anatomy and catheter position in swine. Real-time imaging of catheter position was performed with relatively high spatial and temporal resolution, providing 2 x 2 x 8 mm spatial resolution and four to eight frames per second. Two interactive features were introduced. The number of projections (Np) was adjusted interactively to trade off imaging speed and artifact reduction, allowing acquisition of high-quality or high-frame-rate images. Thin-slice imaging was performed, with interactive requests for thick-slab projection images of the signal received solely from the active catheter. Briefly toggling on catheter-only projection images was valuable for verifying that the catheter tip was contained within the selected slice, or for locating the catheter when part of it was outside the selected slice.

Animals↗

Centering the projection reconstruction trajectory: reducing gradient delay errors.

The projection reconstruction (PR) trajectory was investigated for the effect of gradient timing delays between the actual and requested start time of each physical gradient. Radial trajectories constructed with delayed gradients miss the center of k-space in an angularly dependent manner, causing effective echo times to vary with projection angle. The gradient timing delays were measured in phantoms, revealing delays on the x, y, and z gradients which differed by as much as 5 micro sec. Using this one-time calibration measurement, the trajectories were corrected for gradient delays by addition of compensatory gradient areas to the prephasers of the logical x and y readout gradients. Effective projection-to-projection echo time variability was reduced to less than 1 micro sec for all imaging orientations. Using corrected trajectories, artifacts were reduced in phantom images and in volunteer studies. This correction should potentiate greater clinical use of the PR trajectory.

Algorithms↗

Real-time imaging of two-dimensional cardiac strain using a harmonic phase magnetic resonance imaging (HARP-MRI) pulse sequence.

The harmonic phase (HARP) method provides automatic and rapid analysis of tagged magnetic resonance (MR) images for quantification and visualization of myocardial strain. In this article, the development and implementation of a pulse sequence that acquires HARP images in real time are described. In this pulse sequence, a CINE sequence of images with 1-1 spatial modulation of magnetization (SPAMM) tags are acquired during each cardiac cycle, alternating between vertical and horizontal tags in successive heartbeats. An incrementing train of imaging RF flip angles is used to compensate for the decay of the harmonic peaks due to both T(1) relaxation and the applied imaging pulses. The magnitude images displaying coarse anatomy are automatically reconstructed and displayed in real time after each heartbeat. HARP strain images are generated offline at a rate of four images per second; real-time processing should be possible with faster algorithms or computers. A comparison of myocardial contractility in non-breath-hold and breath-hold experiments in normal humans is presented.

Adult↗

System for MR image-guided prostate interventions: canine study.

The purpose of this study was to demonstrate the use of a transrectal system that enables precise magnetic resonance (MR) image guidance and monitoring of prostate interventions. The system used a closed-bore 1.5-T MR imaging unit and enables one to take advantage of the higher signal-to-noise ratio achieved with traditional magnet designs, which is crucial for accurate targeting and monitoring of prostate interventions. In the first of the four canine studies, reliable needle placement, with all needles placed within 2 mm of the desired target site, was achieved. In two other studies, MR imaging was used to monitor distribution of injected contrast agent solution (gadopentetate dimeglumine mixed with trypan blue dye) in and around the prostate, thereby confirming that solution had been delivered to the desired tissue and also detecting faulty injections. In the final study, accurate placement and MR imaging of brachytherapy seeds in the prostate were demonstrated. The described system provides a flexible platform for a variety of minimally invasive MR image-guided therapeutic and diagnostic prostate interventions.

Animals↗

Multiple field of view MR fluoroscopy.

This work describes a real-time imaging and visualization technique that allows multiple field of view (FOV) imaging. A stream of images from a single receiver channel can be reconstructed at multiple FOVs within each image frame. Alternately, or in addition, when multiple receiver channels are available, image streams from each channel can be independently reconstructed at multiple FOVs. The implementation described here provides for real-time visualization of the placement of guidewires and catheters on a dynamic roadmap during interventional procedures. The loopless catheter antenna, an electrically active intravascular probe, was used for MR signal reception. In 2D projection images, the catheter and surrounding structures within its diameter of sensitivity appear as bright signal. The simplicity of the resulting images allows very-narrow-FOV imaging to decrease imaging time. Very-narrow-FOV images are acquired on MR receiver channels that collect guidewire or catheter data. These very-narrow-FOV images provide very high frame rate continuous, real-time imaging of the interventional devices (25 fps). Large-FOV images are formed from receiver channels that collect anatomical data from standard imaging surface coils, and simultaneously provide a dynamic, frequently updated roadmap. These multiple-FOV images are displayed together, improving visualization of interventional device placement.

Animals↗

Spinal dural arteriovenous fistula localization with a technique of first-pass gadolinium-enhanced MR angiography: initial experience.

Nine patients with initial magnetic resonance (MR) imaging and clinical findings suggestive of spinal dural arteriovenous fistula (AVF) underwent spinal MR angiography with an autotriggered elliptic centric ordered three-dimensional gadolinium-enhanced technique (hereafter, this MR angiographic technique) before conventional intraarterial angiography. In all nine patients, findings with this MR angiographic technique correctly and precisely localized the spinal dural AVF. Observer error resulted in one case in which the site of the fistula was not prospectively reported but was easily identified retrospectively on the spinal MR angiogram.

Adult↗