Automated detection and quantitation of bacterial RNA by using electrical microarrays.

Low-density electrical 16S rRNA specific oligonucleotide microarrays and an automated analysis system have been developed for the identification and quantitation of pathogens. The pathogens are Escherichia coli, Pseudomonas aeruginosa, Enterococcus faecalis, Staphylococcus aureus, and Staphylococcus epidermidis, which are typically involved in urinary tract infections. Interdigitated gold array electrodes (IDA-electrodes), which have structures in the nanometer range, have been used for very sensitive analysis. Thiol-modified oligonucleotides are immobilized on the gold IDA as capture probes. They mediate the specific recognition of the target 16S rRNA by hybridization. Additionally three unlabeled oligonucleotides are hybridized in close proximity to the capturing site. They are supporting molecules, because they improve the RNA hybridization at the capturing site. A biotin labeled detector oligonucleotide is also allowed to hybridize to the captured RNA sequence. The biotin labels enable the binding of avidin alkaline phophatase conjugates. The phosphatase liberates the electrochemical mediator p-aminophenol from its electrically inactive phosphate derivative. The electrical signals were generated by amperometric redox cycling and detected by a unique multipotentiostat. The read out signals of the microarray are position specific current and change over time in proportion to the analyte concentration. If two additional biotins are introduced into the affinity binding complex via the supporting oligonucleotides, the sensitivity of the assays increase more than 60%. The limit of detection of Escherichia coli total RNA has been determined to be 0.5 ng/microL. The control of fluidics for variable assay formats as well as the multichannel electrical read out and data handling have all been fully automated. The fast and easy procedure does not require any amplification of the targeted nucleic acids by PCR.

Automation↗

DNA hybridization detection on electrical microarrays using coulostatic pulse technique.

We demonstrated a novel application of transient coulostatic pulse technique for the detection of label free DNA hybridization on nm-sized gold interdigitated ultramicroelectrode arrays (Au-IDA) made in silicon technology. The array consists of eight different positions with an Au-IDA pair at each position arranged on the Si-based Biochip. Immobilization of capture probes onto the Au-IDA was accomplished by self-assembling of thiol-modified oligonucleotides. Target hybridization was indicated by a change in the magnitude of the time dependant potential relaxation curve in presence of electroactive Fe(CN)(6)(3-) in the phosphate buffer solution. While complementary DNA hybridization showed 50% increase in the relaxation potential, the non-complementary DNA showed a negligible change. A constant behaviour was noted for all positions. The dsDNA specific intercalating molecule, methylene blue, was found to be enhancing the discrimination effect. The changes in the relaxation potential curves were further corroborated following the ELISA like experiments using ExtraAvidine alkaline phosphatase labelling and redox recycling of para-aminophenol phosphate at IDAs. The coulostatic pulse technique was shown to be useful for identifying DNA sequences from brain tumour gene CK20, human herpes simplex virus, cytomegalovirus, Epstein-Barr virus and M13 phage. Compared to the hybridization of short chain ONTs (27 mers), the hybridization of long chain M13 phage DNA showed three times higher increase in the relaxation curves. The method is fast enough to monitor hybridization interactions in milli or microsecond time scales and is well suitable for miniaturization and integration compared to the common impedance techniques for developing capacitative DNA sensors.

DNA↗

Novel micromachined silicon sensor for continuous glucose monitoring.

The construction and the application properties of a micro-machined silicon sensor for continuous glucose monitoring are presented. The sensor uses the conventional enzymatic conversion of glucose with amperometric detection of H(2)O(2). The innovation is the precise diffusion control of the analyte through a porous silicon membrane into a silicon etched cavity containing the immobilised enzyme. A variation of the number and size of the membrane pores allows to adjust the linear range of the sensor to the respective requirement. The sensor was tested in vitro as well as in clinical studies, being supplied with interstitial fluid. The cavity sensor was designed for a linear range between 0.5 and 20 mM. A signal response time of below 30 s and a signal stability exceeding 1 week is shown. By using a double cavity sensor falsification of the glucose signal by interfering substances can be compensated. In clinical trials the sensor measured continuously in interstitial fluid for up to 18 h without any signal drift and with good correlation to blood glucose reference values.

Biosensing Techniques↗

Micromachined sensor for lactate monitoring in saliva.

A miniaturised sensor for continuous lactate measurement in saliva was developed and tested. The sensor was built using silicon microfabrication technologies. The size of the chip is 5.5 mmx6.4 mmx0.7 mm and features a working, a counter and an Iridium reference electrode. The chip has a cavity whose floor is perforated by fine pores. The cavity contains the enzyme lactate oxidase (LOD), which is immobilised in an agarose gel. Prior to the amperometric detection of the reaction product hydrogen peroxide at the working electrode, the analyte lactate has to pass the pores to reach the cavity with the lactate oxidase by diffusion. To test the silicon sensor, capillary blood and saliva samples were obtained during standardised ergometer tests. Salivary lactate concentrations were determined with the sensor and compared to photometrically derived data from a lab-automate. In addition the saliva data were compared to standard capillary blood lactate concentrations measured with a pocket photometer. Lactate concentration versus load graphs were plotted and compared visually showing very similar progressions. The novel approach enables a location independent, permanent real-time measurement of the lactate concentration during exercise.

Biosensing Techniques↗

Label-free impedance detection of oligonucleotide hybridisation on interdigitated ultramicroelectrodes using electrochemical redox probes.

The direct detection of oligodeoxynucleotide (ODN) hybridisation using electrochemical impedance spectroscopy was made on interdigitated array (IDA) gold (Au) ultramicroelectrodes manufactured by silicon technology. The immobilisation of single stranded ODNs (ssODNs) was accomplished by self-assembling of thiol-modified ODNs onto an Au-electrode surface. Faradaic impedance was measured in the presence of K(3)[Fe(CN)(6)]. Double strand formation was identified by a decrease of approximately 50% in impedance in the low frequency region in the presence of K(3)[Fe(CN)(6)], compared to the spectrum of single stranded ODN. The frequency dependent diffusion of Fe(CN)(6)(3-) ions through defects in the ODN monolayer determines the impedance of Au-ssODN surface. The influence of DNA intercalator methylene blue on the impedance of both, single and double strands, was examined along with K(3)[Fe(CN)(6)] and confirmed by cyclic voltammetry. The layer densities and the hybridisation have been further corroborated by chronoamperometric redox recycling of para-aminophenol (p-AP) in ELISA like experiments. It can be concluded, that a performed impedance spectroscopy did not change the layer density. The impedance spectroscopy at ultramicroelectrodes combined with faradaic redox reactions enhances the impedimetric detection of DNA hybridisation on IDA platforms.

DNA↗

Rapid detection of viruses using electrical biochips and anti-virion sera.

AIMS: Rapid detection and quantification of viruses is crucial in clinical practice, veterinary medicine, agriculture, basic research as well as in biotechnological factories. However, although various techniques were described and are currently used, development of more rapid, more sensitive and quantitative methods seems to be still important. METHODS AND RESULTS: Here we describe a method for rapid detection of viruses (using bacteriophages as model viruses), based on electrical biochip array technology with the use of antibodies against capsid proteins. CONCLUSIONS: Using the procedure developed in this work, we were able to detect 2 x 10(4) virions on the chip. The whole assay procedure takes c. 50 min and the assay is quantitative. SIGNIFICANCE AND IMPACT OF THE STUDY: This procedure may be useful in various approaches, including detection of bacteriophage contamination in bioreactors and possibly detection of toxin gene-bearing phages or other viruses in food samples.

Antibodies, Viral↗

Electric chips for rapid detection and quantification of nucleic acids.

A silicon chip-based electric detector coupled to bead-based sandwich hybridization (BBSH) is presented as an approach to perform rapid analysis of specific nucleic acids. A microfluidic platform incorporating paramagnetic beads with immobilized capture probes is used for the bio-recognition steps. The protocol involves simultaneous sandwich hybridization of a single-stranded nucleic acid target with the capture probe on the beads and with a detection probe in the reaction solution, followed by enzyme labeling of the detection probe, enzymatic reaction, and finally, potentiometric measurement of the enzyme product at the chip surface. Anti-DIG-alkaline phosphatase conjugate was used for the enzyme labeling of the DIG-labeled detection probe. p-Aminophenol phosphate (pAPP) was used as a substrate. The enzyme reaction product, p-aminophenol (pAP), is oxidized at the anode of the chip to quinoneimine that is reduced back to pAP at the cathode. The cycling oxidation and reduction of these compounds result in a current producing a characteristic signal that can be related to the concentration of the analyte. The performance of the different steps in the assay was characterized using in vitro synthesized RNA oligonucleotides and then the instrument was used for analysis of 16S rRNA in Escherichia coli extract. The assay time depends on the sensitivity required. Artificial RNA target and 16S rRNA, in amounts ranging from 10(11) to 10(10) molecules, were assayed within 25 min and 4 h, respectively.

Biosensing Techniques↗

[Multi-value regulatory systems for extracorporeal circulation].

Extracorporeal perfusion is the standard technique in cardiac surgery. It is controlled by perfusionists on the basis of their clinical experience and on the available data collected pre- and intra-operatively. But in spite of intensive monitoring postoperative complications occur. An appropriate control of the heart-lung machine (HLM) using an "autopilot" might improve the quality of heart-surgery and decrease postoperative complications. Hence, a mathematical model of a human circulatory system has been developed which provides much more information about haemodynamics, blood gases and acid-base status than standard monitoring. It has been implemented on a system which is capable of integrating measured data as input parameters in real-time in the simulation. Now, soft- and hardware control concepts based on the human circulatory system have to be developed which are able to control the HLM.

Coronary Disease↗

Evaluation of models.

Evaluation of models describing computer based technology is crucial for further evolution of medical progress. In this project, the research sites of the Sonderforschungsbereich 414 "Computer and sensor aided surgery" were linked for evaluation purposes. Topics of flow, morphology, function, and robotics in the field of cardiac and oromaxillofacial surgery are addressed. Key methods are animal models, phantoms, image processing and clinical studies in the setting of exactly defined circumstances. As an example, 3D evaluation of myocardial edema is presented. Heterogeneity of 3D distribution of induced myocardial edema was validated. Temporal dynamics of edema is described as an example. Based on such models, diagnostic and operation relevant planning data are offered to cardiac surgeons.

Animals↗

3D evaluation of myocardial edema: experimental study on 22 pigs using magnetic resonance and tissue analysis.

BACKGROUND: Myocardial edema (ME) adversely affects ventricular function. Thus, we performed an animal study to demonstrate (1) 3D-ME using magnetic resonance imaging (MRI), which can show ME depending on myocardial location, (2) type of cardioplegic solution, and (3) quantification tools. METHODS: Pig hearts (n = 22) were perfused using Bretschneider's solution (BRET, n = 8), butanedionemonoxime (BDM, n=8), or no cardioplegia as controls (CTRL, n = 6). Hearts underwent MRI (T(1)-inversion recovery). Myocardial water content (MWC, reference method) was determined from left ventricle anterior, posterior (PW), lateral wall, interventricular septum, papillary muscle, right ventricle wall. Images underwent 3D reconstruction using ray-tracing. Gray-value analysis was performed on "virtual" samples. For statistical analysis, ANOVA, Student's t-test, and the Student-Newman-Keuls test were used. RESULTS: (1) ME was induced (p < 0.0001 vs. control). Localization differed in MWC, p = 0.003 (BRET), p = 0.023 (BDM), highest at PW (p < 0.01). (2) Differences between the cardioplegia groups were not significant. (3) "Virtual" samples showed equal distribution (BRET: p = 0.007, BDM: p = 0.003), highest at PW (p < 0.01). CONCLUSIONS: We validated 3D assessment of induced ME in pig hearts using MRI. The method may therefore become an exact tool in monitoring cardioplegia.

Animals↗

[Optimizing temporal resolution in CT with retrospective ECG gating].

PURPOSE: Spiral CT of the heart using the established ways of ECG synchronization is hampered by the relatively long acquisition times of 250 to 500 ms. This only allows to acquire diastolic images in patients with moderate heart rates. In this work, algorithms for time-optimized retrospective cardiac gating are presented, and their potential to improve temporal resolution is investigated. MATERIAL AND METHODS: These algorithms use data from multiple gantry rotations for image reconstruction, which is possible for multi-scans at fixed slice positions as well as for overlapping spiral scans. Temporal resolution was quantified using computer simulations and compared to experimental data from pigs. RESULTS: Using a conventional sub-second CT scanner, considerably higher temporal resolutions are possible with spiral scanning. A temporal resolution of 170 ms already provides systolic images with little motion artifacts. Higher temporal resolutions of up to 70 ms are demonstrated for multi-scans, which allows to depict ventricle wall movement over the complete cardiac cycle. DISCUSSION: The method of time-optimized retrospective cardiac gating broadens the spectrum of conventional spiral-CT for cardiac imaging. It can be directly transferred to multi-slice scanners. Here it can be used clinically because of reduced scan time. Potential applications are the determination of functional cardiac parameters like ejection fraction and the detection of disorders of ventricle wall movement.

Algorithms↗

CardioOp: an integrated approach to teleteaching in cardiac surgery.

INTRODUCTION/PURPOSE: The complexity of cardiac surgery requires continuous training, education and information addressing different individuals: physicians (cardiac surgeons, residents, anaesthesiologists, cardiologists), medical students, perfusionists and patients. Efficacy and efficiency of education and training will likely be improved by the use of multimedia information systems. Nevertheless, computer-based education is facing some serious disadvantages: 1) multimedia productions require tremendous financial and time resources; 2) the obtained multimedia data are only usable for one specific target user group in one specific instructional context; 3) computer based learning programs often show deficiencies in the support of individual learning styles and in providing individual information adjusted to the learner's individual needs. In this paper we describe a computer-system, providing multiple re-use of multimedia-data in different instructional sceneries and providing flexible composition of content to different target user groups. TOOLS AND METHODS: The ZYX document model has been developed, allowing the modelling and flexible on-the-fly composition of multimedia fragments. It has been implemented as a DataBlade module into the object-relational database system Informix Dynamic Server and allows for presentation-neutral storage of multimedia content from the application domain, delivery and presentation of multimedia material, content based retrieval, re-use and composition of multimedia material for different instructional settings. Multimedia data stored in the repository, that can be processed and authored in terms of our identified needs is created by using a next generation authoring environment called CardioOP-Wizard. High-quality intra-operative video is recorded using a video-robot. Difficult surgical procedures are visualized with generic and CT-based 3D-animations. RESULTS: An on-line architecture for multiple re-use and flexible composition of media data has been established. The system contains the following instructional applications (prototypically implemented): a multimedia textbook on operative techniques, an interactive module for problem based-training, a module for creation and presentation of lectures and a module for patient information. Principles of cognitive psychology and knowledge management have been employed in the program. These instructional applications provide information ranging from basic knowledge at the beginner's level, procedural knowledge for the advanced level to implicit knowledge for the professional level. For media-annotation with meta-data a metainformation system, the CardioOP-Clas has been developed. The prototype focuses on aortocoronary bypass grafting and heart transplantation. CONCLUSION: The demonstrated system reflects an integrated approach in terms of information technology and teaching by means of multiple re-use and composition of stored media-items to the individual user and the chosen educational setting on different instructional levels.

Computer Simulation↗

Assessment of mitral regurgitant jets by three-dimensional color Doppler.

BACKGROUND: Color Doppler echocardiography is a standard technique for assessing mitral regurgitation before and after mitral valvuloplasty. Mitral valve prolapse produces complex eccentric jet flows that cannot be visualized and measured by two-dimensional color Doppler echocardiography. The aim of this study was to evaluate the clinical impact of three-dimensional color Doppler echocardiography, a new technique developed at our institution, for assessing mitral regurgitation. METHODS: Forty-five patients with mitral regurgitation underwent intraoperative transesophageal echocardiography and three-dimensional Doppler data acquisition. The grade of mitral regurgitation was assessed by angiography. The jet areas were calculated by planimetry from conventional color Doppler; the jet volumes were obtained by three-dimensional Doppler data. RESULTS: New patterns of mitral regurgitant flows were recognized according to the origin, direction, and spatial spreading into the left atrium. Conventional jet areas failed to separate the groups of patients with different degrees of regurgitation, whereas the jet volumes were able to divide patients with different regurgitation grades. No significant correlation was found between jet area and angiographic grading (r = 0.63, p = NS). Jet volumes were significantly correlated to angiography (r = 0.89, p < 0.001). CONCLUSIONS: Three-dimensional color Doppler echocardiography revealed new patterns of regurgitant flow and allowed a more accurate semiquantitative assessment of complex asymmetrical regurgitant jets.

Blood Flow Velocity↗

Three-dimensional color Doppler: a clinical study in patients with mitral regurgitation.

OBJECTIVES: The purpose of this study was to assess the clinical feasibility of three-dimensional (3D) reconstruction of color Doppler signals in patients with mitral regurgitation. BACKGROUND: Two-dimensional (2D) color Doppler has limited value in visualizing and quantifying asymmetric mitral regurgitation. Clinical studies on 3D reconstruction of Doppler signals in original color coding have not yet been performed in patients. We have developed a new procedure for 3D reconstruction of color Doppler. METHODS: We studied 58 patients by transesophageal 3D echocardiography. The jet area was assessed by planimetry and the jet volumes by 3D Doppler. The regurgitant fractions, the volumes, and the angiographic degree of mitral regurgitation were assessed in 28 patients with central jets and compared with those of 30 patients with eccentric jets. RESULTS: In all patients, jet areas and jet volumes significantly correlated with the angiographic grading (r = 0.73 and r = 0.90), the regurgitant fraction (r = 0.68 and r = 0.80) and the regurgitant volume (r = 0.66 and r = 0.90). In patients with central jets, significant correlations were found between jet area and angiography (r = 0.86), regurgitant fraction (r = 0.64) and regurgitant volume (r = 0.78). No significant correlations were found between jet area and angiography (r = 0.53), regurgitant fraction (r = 0.52) and regurgitant volume (r = 0.53) in the group of patients with eccentric jets. In contrast, jet volumes significantly correlated with angiography (r = 0.90), regurgitant fraction (r = 0.75) and regurgitant volume (r = 0.88) in the group of patients with eccentric jets. CONCLUSIONS: Three-dimensional Doppler revealed new images of the complex jet geometry. In addition, jet volumes, assessed by an automated voxel count, independent of manual planimetry or subjective estimation, showed that 3D Doppler is also capable of quantifying asymmetric jets.

Adult↗

Three-dimensional color Doppler: a new approach for quantitative assessment of mitral regurgitant jets.

Color Doppler echocardiography does not provide adequate information about the severity of mitral regurgitation in patients with eccentric mitral regurgitation. We have developed a new procedure for 3-dimensional (3D) color Doppler reconstruction and for segmentation of regurgitant jets. The volume of regurgitant jets was compared with jet area in 63 patients with mitral regurgitation. Mitral regurgitation was assessed by angiography, regurgitant fraction and volume by pulsed Doppler, JA by planimetry, and JV by 3-dimensional Doppler. Twenty-eight patients with central jets were compared with 35 patients with eccentric jets. In the patients with eccentric jets, JV showed significant correlations with regurgitant volume (r = 0.90; P <.01) and regurgitant fraction (r = 0.76; P < .01) and was able to separate groups with different degrees of mitral regurgitation (P <.01). Three-dimensional Doppler revealed origin, direction, and spatial spreading of complex jet geometry. JV, a new parameter of mitral regurgitation, was also capable of quantifying asymmetrical jets.

Echocardiography, Doppler, Color↗

Three-dimensional color Doppler for assessing mitral regurgitation during valvuloplasty.

OBJECTIVE: Transesophageal color Doppler (or 2D Doppler) is the most widely used technique for intraoperative assessment of mitral valve repair. However, the most severe mitral regurgitations produce eccentric jet flows which cannot be assessed by 2D imaging. Up to now the indications for surgical intervention and intraoperative decisions after valve repair have been based on 2D Doppler examinations. Aim of this study was to compare conventional 2D Doppler to three-dimensional (3D) Doppler for assessing residual regurgitation in patients after mitral valvuloplasty. METHODS: Twenty-four patients were referred to surgery for mitral valve repair. They underwent transesophageal echocardiography and 3D data acquisition during mitral valve reconstruction. Conventional assessment of mitral valve regurgitation, measured by color Doppler jet area, was compared to the volume of regurgitant jets obtained by 3D Doppler. Regurgitant volume and fraction were measured by pulsed Doppler and two-dimensional echocardiography. The 3D reconstructions of color Doppler data were accomplished by means of the 'Heidelberg Raytracing Algorithm' developed at our institution. RESULTS: The jet areas did not show any significant correlation to the regurgitant fraction (r = 45; P = NS) or regurgitant volumes (r = 0.40; P = NS). In contrast the jet volumes correlated significantly to regurgitant fraction (r = 0.71; P < 0.01) and regurgitant volume (r = 0.85; P < 0.01). The reproducibility analysis of repeated jet volume and jet area measurements also showed that the parameter jet volume has a lower variability and higher agreement of repeated measurements than jet area. CONCLUSIONS: Three-dimensional color Doppler flow imaging revealed the complex geometry of eccentric regurgitant jets and showed that the assessment of mitral regurgitation, based on conventional 2D Doppler, can be misleading. This new technique has a great potential for becoming a reference method for assessing mitral valve repair.

Blood Flow Velocity↗