Search PubMed⌕ Search

Biomedical subjects

J A de Zwart

Publications and source records attributed to J A de Zwart.

11 recordsLinked to original sources

fMRI study of effort and information processing in a working memory task.

It is unclear how effort translates into brain function. In this study we endeavored to identify the activity in a working memory task that is related to the allocation of mental resources. Such activity, if present, would be a likely candidate to explain how effort works in terms of brain function. Eleven healthy participants performed a Sternberg task with a memory-set of one, three, or five consonants in an fMRI study. Probe stimuli were either one consonant or one digit. We expected digits to be processed automatically and consonants to require working memory. Because the probe type was unpredictable and subjects had to respond as fast as possible, we expected subjects to allocate mental resources on the basis of the memory-set size, not the probe type. Accordingly, we anticipated that activity in regions involved in effort would be a function of the size of the memory-set, but independent of the type of probe. We found that the reaction-time for digits increased in line with our expectation of automatic processing and the reaction time for letters increased in line with our expectation of controlled processing. fMRI revealed that activity in the right ventral-prefrontal cortex changed as a function of effort. The ventral anterior cingulate cortex and hypothalamus showed reduced activity as a function of effort. Activity in regions regarded as pivotal for working memory (among others, the left dorsolateral prefrontal cortex, anterior cingulate cortex) appeared to be predominantly related to information processing and not involved in effort.

Adult↗

Spatial and temporal control of transgene expression in vivo using a heat-sensitive promoter and MRI-guided focused ultrasound.

BACKGROUND: Among the techniques used to induce and control gene expression, a non-invasive, physical approach based on local heat in combination with a heat-sensitive promoter represents a promising alternative but requires accurate temperature control in vivo. MRI-guided focused ultrasound (MRI-FUS) with real-time feedback control allows automatic execution of a predefined temperature-time trajectory. The purpose of this study was to demonstrate temporal and spatial control of transgene expression based on a well-defined local hyperthermia generated by MRI-FUS. METHODS: Expression of the green fluorescent protein (GFP) marker gene was used. Two cell lines were derived from C6 glioma cells. The GFP expression of the first one is under the control of the CMV promoter, whereas it is under the control of the HSP70 promoter in the second one and thus inducible by heat. Subcutaneous tumours were generated by injection in immuno-deficient mice and rats. Tumours were subjected to temperatures varying from 42 to 50 degrees C for 3 to 25 min controlled by MRI-FUS and analyzed 24 h after the heat-shock. Endogenous HSP70 expression and C6 cell distribution were also analyzed. RESULTS: The results demonstrate strong expression at 50 degrees C applied during a short time period (3 min) without affecting cell viability. Induced expression was also clearly shown for temperature in the range 44-48 degrees C but not at 42 degrees C. CONCLUSIONS: Heating with MRI-FUS allows a tight and non-invasive control of transgene expression in a tumour.

Animals↗

On-line correction and visualization of motion during MRI-controlled hyperthermia.

Displacement of tissue during MRI-controlled hyperthermia therapy can cause significant problems. Errors in calculated temperature may result from motion-related image artifacts and inter-image object displacement, leading to incorrect spatial temperature reference. Here, cyclic navigator echoes were incorporated in rapid gradient-echo MRI sequences, used for temperature mapping based on the proton resonance frequency. On-line evaluation of navigator information was used in three ways. First, motion artifacts were minimized in echo-shifted (TE > TR) gradient-echo images using the phase information of the navigator echo. Second, navigator profiles were matched for a quantitative evaluation of displacement. Together with a novel processing method, this information was employed to correct the reference temperature maps, thereby avoiding persistence of motion-related temperature errors throughout the hyperthermic period. Third, on-line visualization of displacement, together with temperature maps and thermal dose images, was developed, allowing physician intervention at all times. Examples are given of on-line corrections during hyperthermia procedures with focused ultrasound and radiofrequency heat sources. Magn Reson Med 45:128-137, 2001.

Animals↗

Thermal therapies in interventional MR imaging. Focused ultrasound.

MR image-guided focused ultrasound (FUS) provides an entirely noninvasive approach for local thermal therapies. MR imaging allows target definition and continuous temperature mapping. Therefore, the heating procedure can be controlled spatially and temporally based on automatic feedback to the FUS apparatus. Phased-array ultrasound technology will further help the development. MR imaging/FUS may be applied not only for tissue ablation, but also for local drug delivery, gene therapy, and drug activation.

Animals↗

Hyperthermia by MR-guided focused ultrasound: accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction.

Temperature regulation in MR-guided focused ultrasound requires rapid MR temperature mapping and automatic feedback control of the ultrasound output. Here, a regulation method is proposed based on a physical model of local energy deposition and heat conduction. The real-time evaluation of local temperature gradients from temperature maps is an essential element of the control system. Each time a new image is available, ultrasound power is adjusted on-the-fly in order to obtain the desired evolution of the focal point temperature. In vitro and in vivo performance indicated fast and accurate control of temperature and a large tolerance of errors in initial estimates of ultrasound absorption and heat conduction. When using correct estimates for the physical parameters of the model, focal point temperature was controlled within the measurement noise limit. Initial errors in absorption and diffusion parameters are compensated for exponentially with a user-defined response time, which is suggested to be on the order of 10 sec.

Animals↗

Magnetic resonance temperature imaging for guidance of thermotherapy.

Continuous thermometry during a hyperthermic procedure may help to correct for local differences in heat conduction and energy absorption, and thus allow optimization of the thermal therapy. Noninvasive, three-dimensional mapping of temperature changes is feasible with magnetic resonance (MR) and may be based on the relaxation time T(1), the diffusion coefficient (D), or proton resonance frequency (PRF) of tissue water. The use of temperature-sensitive contrast agents and proton spectroscopic imaging can provide absolute temperature measurements. The principles and performance of these methods are reviewed in this paper. The excellent linearity and near-independence with respect to tissue type, together with good temperature sensitivity, make PRF-based temperature MRI the preferred choice for many applications at mid to high field strength (>/= 1 T). The PRF methods employ radiofrequency spoiled gradient-echo imaging methods. A standard deviation of less than 1 degrees C, for a temporal resolution below 1 second and a spatial resolution of about 2 mm, is feasible for a single slice for immobile tissues. Corrections should be made for temperature-induced susceptibility effects in the PRF method. If spin-echo methods are preferred, for example when field homogeneity is poor due to small ferromagnetic parts in the needle, the D- and T(1)-based methods may give better results. The sensitivity of the D method is higher that that of the T(1) methods provided that motion artifacts are avoided and the trace of D is evaluated. Fat suppression is necessary for most tissues when T(1), D, or PRF methods are employed. The latter three methods require excellent registration to correct for displacements between scans.

Animals↗

Local hyperthermia with MR-guided focused ultrasound: spiral trajectory of the focal point optimized for temperature uniformity in the target region.

The objective of hyperthermia treatment is to deliver a similar therapeutic thermal dose throughout the target volume within a minimum amount of time. We describe a noninvasive approach to this goal based on magnetic resonance imaging (MRI)-guided focused ultrasound (FUS) with a spherical transducer that can be moved along two directions inside the bed of a clinical MR imager and that has an adjustable focal length in the third dimension. Absorption of FUS gives rise to a highly localized thermal buildup, which then spreads by heat diffusion and blood perfusion. A uniform temperature within a large target volume can be obtained using a double spiral trajectory of the transducer focal point together with constant and maximum FUS power. Differences between the real and target temperatures during the first spiral are evaluated in real time with temperature MRI and corrected for during the second spiral trajectory employing FUS focal point velocity modulation. Once a uniform temperature distribution is reached within the entire volume, FUS heating is applied only at the region's boundaries to maintain the raised temperature levels. Heat conduction, together with the design and timing of the trajectories, therefore ensures a similar thermal dose for the entire target region. Good agreement is obtained between theory and experimental results in vitro on gel phantoms, ex vivo on meat samples, and in vivo on rabbit thigh muscle. Edema in muscle was visible 1 hour after hyperthermia as a spatially uniform rise of the signal intensity in T(2)-weighted images.

Animals↗

An echo-shifted gradient-echo MRI method for efficient diffusion weighting.

A segmented magnetic resonance imaging (MRI) method is introduced with time-efficient diffusion weighting resulting in total imaging times similar to those of single-shot methods. The approach is based on the principles of echo shifting with a train of observations (PRESTO) MRI sequence. The time efficiency of the sequence is based on the use of diffusion gradient pulses that also serve to shift the echo train to the next TR period, resulting in TE > TR. Each diffusion gradient is therefore used twice, for dephasing one set of spins as well as rephasing a second set of spins. Diffusion weighting and acquisition are thus achieved simultaneously. The sequence is validated in vitro and in vivo on rat kidney.

Animals↗

Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.

The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo imaging with spectral-spatial excitation is demonstrated, resulting in accurate and rapid, lipid-suppressed, MR thermometry. The method was validated on phantoms, fatty duck liver, and rat thigh, demonstrating improvements in both the speed and precision of temperature mapping. Heating of a rat thigh with focused ultrasound was monitored in vivo with an accuracy of 0.37 degree C and a time resolution of 438 msec.

Animals↗

On the feasibility of MRI-guided focused ultrasound for local induction of gene expression.

Gene therapy is a promising approach to the treatment of many forms of disease, including cancer. Of critical concern in its implementation is the ability to control the location, duration, and level of expression of the therapeutic gene. Here, we propose the use of local heat in combination with a heat-sensitive promoter to help accomplish this. Certain members of the family of heat shock protein (hsp) promoters display a regulation that depends strongly on temperature. We present a study of natural hsp70 induction in rat leg by MRI-guided focused ultrasound to investigate the hsp70 promoter as a possible candidate for use in control of gene expression with local heat. A temperature increase of 5-8 degrees C in the focal region for 45 minutes led to a differential expression of the hsp70 mRNA between the focal region and the surrounding tissue ranging from a factor of 3 to 67.

Animals↗