J A Ormiston

Publications and source records attributed to J A Ormiston.

At least 19 recordsLinked to original sources

Lack of association between baseline plasma homocysteine concentrations and restenosis rates after a first elective percutaneous coronary intervention without stenting.

OBJECTIVE: To evaluate the association between baseline homocysteine concentrations and restenosis rates in patients electively undergoing their first percutaneous coronary intervention (PCI) without stenting. DESIGN: Prospective, single centre, observational study. SETTING AND PATIENTS: Patients electively undergoing their first PCI without stenting at a tertiary referral centre between 1990 and 1998. METHODS: Blood samples were collected from all patients at baseline and assayed to determine the patients' homocysteine concentrations. Patients whose PCI was successful underwent repeat angiography at a median of 6.4 (interquartile range 6-6.8) months. Their baseline and follow up angiograms were compared by quantitative coronary angiography to assess the incidence of restenosis. For the analysis, the patients were divided into two groups based on whether their baseline homocysteine concentrations were above or below the median value. These two groups were compared to determine whether there was any association between their baseline homocysteine concentrations and the incidence of restenosis at six months. RESULTS: 134 patients had a successful first PCI without stenting (involving 200 lesions). At six month angiography, restenosis was observed in 33 patients (49.3%) with baseline homocysteine concentrations above the median value and in 31 patients (46.3%) with concentrations below the median value (p = 0.74). There was no difference in the percentage of lesions developing restenosis (38 (39.6%) v 40 (38.5%), respectively, p = 0.87) or late lumen loss (0.40 mm v 0.31 mm, respectively, p = 0.24). On multivariable analysis, there was no association between homocysteine concentrations and late lumen loss (r = -0.11, p = 0.11) or the percentage diameter stenosis at follow up (r = -0.07, p = 0.32). CONCLUSION: Baseline homocysteine concentrations were not associated with six month restenosis rates in patients electively undergoing their first PCI without stenting.

Angioplasty, Balloon, Coronary↗

Clinical and angiographic factors associated with asymptomatic restenosis after percutaneous coronary intervention.

BACKGROUND: Angiographic restenosis after percutaneous coronary interventional procedures is more common than recurrent angina. Clinical and angiographic factors associated with asymptomatic versus symptomatic restenosis after percutaneous coronary intervention were compared. METHODS AND RESULTS: All patients with angiographic restenosis from the BENESTENT I, BENESTENT II pilot, BENESTENT II, MUSIC, WEST 1, DUET, FINESS 2, FLARE, SOPHOS, and ROSE studies were analyzed. Multivariate analysis evaluated 46 clinical and angiographic variables, comparing those with and without angina. The 10 studies recruited 2690 patients who underwent percutaneous revascularization and 6-month follow-up angiography (86% of those eligible). Restenosis (>/=50% diameter stenosis) occurred in 607 patients and was clinically silent in 335 (55%). Male sex (P=0.008), absence of antianginal therapy with nitrates (P=0.0002) and calcium channel blockers (P=0.02) at 6 months, greater reference diameter after the procedure (P=0.04), greater reference diameter at follow-up (P=0.004), and lesser lesion severity (percent stenosis) at 6 months (P=0.0004) were univariate predictors of asymptomatic restenosis. By multivariate analysis, only male sex (P=0.04), greater reference diameter at follow-up (P=0.002), and lesser lesion severity at 6 months (P=0.0001) were associated with restenosis without angina. CONCLUSIONS: Approximately half of patients with angiographic restenosis have no symptoms. The only multivariate predictors of silent restenosis at 6 months were male sex, greater reference diameter at follow-up, and lesser lesion severity on follow-up angiography.

Angioplasty, Balloon, Coronary↗

5 French guide catheters for percutaneous coronary intervention: a feasibility study in 100 consecutive patients.

Percutaneous coronary intervention using smaller-diameter guide catheters may have a favorable impact on groin complications, mobilization time, hospital stay, and contrast use. This prospective registry study assessed the feasibility of routine stent delivery through 5 Fr guide catheters. Of the 100 consecutive patients, 5 Fr guided intervention was attempted in 84 and was successful in all but 2 patients who had chronic complete occlusions. Reasons for not selecting a 5 Fr guide were planned kissing balloons (eight), directional coronary atherectomy (one), and no suitable 5 Fr guide in stock (seven). There was no stent dislodgment, need to change to a larger-caliber guide, or inadequate contrast opacification. When necessary, guide support was achieved by deep-vessel intubation, which was not associated with vascular damage. The only adverse sequelae were non-Q-wave myocardial infarctions in two patients. Coronary artery stenting using 5 Fr guide catheters is feasible and applicable to most patients.

Adult↗

Coronary angioplasty in New Zealand 1995-1998: a report from the National Coronary Angioplasty Registry.

AIMS: To report coronary angioplasty data collected by the New Zealand Coronary Angioplasty Registry from 1995-1998. METHOD: Information on all patients undergoing attempted coronary angioplasty in eight New Zealand institutions was recorded on datasheets at the time of, or soon after, the procedure. These were forwarded to the registry at Green Lane Hospital. RESULTS: Over the four-year period, 8395 angioplasty procedures were performed by 26 cardiologists in eight coronary interventional facilities, with a procedural success rate of 94%. Procedural numbers grew steadily, with 55% more coronary angioplasties performed in 1998 than in 1995 (p = 0.02). The New Zealand national angioplasty rate, which rose from 459/million population in 1995 to 684/million in 1998, remains lower than that of Australia and Western European countries. Excluding those that underwent angioplasty for acute myocardial infarction, the number of peri-procedural deaths was similar, with six in 1995 and four in 1998 (p = 0.30), and the requirement for emergency bypass surgery fell from 22 cases in 1995 to three in 1998 (p < 0.001). The use of stents increased dramatically, with 85% of patients receiving a stent in 1998, compared with 23% in 1995 (370% increase, p < 0.001). This was associated with a reduction in the number of patients requiring repeat percutaneous interventions for restenosis (10.7% in 1995 to 6.4% in 1998, p < 0.001). CONCLUSION: There has been a steady growth in the numbers of patients with coronary artery disease treated by coronary angioplasty, and in the number treated by intracoronary stents from 1995 to 1998. The need for urgent coronary bypass surgery has fallen. Continued submission of complete and accurate data to the coronary angioplasty registry is vital for ongoing audit.

Adult↗

Gelfoam embolization of a distal coronary artery guidewire perforation.

A guidewire-induced distal coronary artery perforation presenting with cardiac tamponade was occluded by distal Gelfoam embolization via an infusion catheter. This extends the treatment options for this rare complication of coronary interventional procedures. Cathet. Cardiovasc. Intervent. 49:214-217, 2000.

Aged↗

Stent longitudinal flexibility: a comparison of 13 stent designs before and after balloon expansion.

Longitudinal flexibility is an important property of coronary stents, facilitating delivery and allowing the expanded stent to conform to vessel contour. Subjective descriptions of flexibility abound, but there are few independent quantitative data to aid stent selection. A three-point bend test was employed to measure stiffness, the reciprocal of flexibility, for 13 stent designs in the unexpanded (bare) state, then after expansion with a 3.5-mm balloon. For eight of the designs, stiffness of the proprietary stent/balloon delivery system was also measured. In the unexpanded state, there was a wide spread of stiffness, which ranged from 0.5+/-0.2 to 91.5+/-10.0 g force/mm, depending on design. Stiffness was least for the coil (Wiktor and Crossflex) and hybrid (AVE GFX and Bard XT) designs. The MultiLink was the most flexible and the Crown the stiffest of the slotted tube designs. All stents became stiffer upon expansion. For most manufacturer-mounted stents, the delivery balloon was the main determinant of stent/balloon delivery system stiffness. Manufacturer-mounted stent profile ranged from 1.15+/-0.11 mm for the Jostent to 1.53 +/- 0.05 mm for the MultiLink system. Independent quantitative assessment of characteristics such as flexibility and profile should aid rational comparison of stent designs.

Equipment Design↗

A randomized study of direct coronary stent delivery compared with stenting after predilatation: the NIR future trial. On behalf of the NIR Future Trial Investigators.

This randomized trial compared a strategy of direct stenting without predilatation (n = 39) with conventional stenting with predilatation (n = 42) in patients with suitable lesions in native vessels > or = 2. 5-mm diameter to be covered by either a 9- or 16-mm-length NIR Primo stent. Equipment cost [mean (median) +/- SD] was less in those with direct stenting [$1,199 (979) +/- 526] than in those with predilatation [$1,455 (1,285) +/- 401, P < 0.001]. There was no significant difference in contrast use or fluoroscopy time. Procedural time was shorter in the direct stenting group. The clinical outcome at 1 month was satisfactory in both groups. In selected patients, a strategy of direct stenting is feasible, costs less, and is quicker to perform than the conventional strategy of stenting following predilatation.

Adult↗

Does angiography six months after coronary intervention influence management and outcome? Benestent II Investigators.

OBJECTIVES: This study was performed to assess whether angiography six months after coronary balloon angioplasty or stent implantation has an influence on clinical management and one-year outcome. BACKGROUND: The Benestent II study randomized 827 patients to balloon angioplasty or stent implantation. A subrandomization was undertaken allocating patients to six-month clinical follow-up (CF) or clinical and angiographic follow-up (AF). METHODS: Seven hundred and six patients (349 CF and 357 AF) had no intercurrent angiography, so that restenosis and disease progression elsewhere remained unknown until the time of six-month follow-up. These two groups, which were well matched at enrolment, were compared with respect to symptoms, medication and major cardiac events defined as death, myocardial infarction and need for revascularization at six and 12 months. RESULTS: At six-month follow-up, 53 (15%) of the CF and 76 (21%) of the AF patients had stable angina (p = 0.041), while 5 (1%) and 4 (1%) had symptoms of unstable angina. At 12-month follow-up, 44 (13%) patients in both groups had stable angina, and only 1 patient in the CF group had unstable angina. Seventy-seven patients (27 CF and 50 AF; p < 0.01) had major cardiac events between 6 and 12 months. Of the 349 patients in the CF group, 21 underwent repeat percutaneous transluminal coronary angioplasty or coronary artery bypass graft surgery between 6 and 12 months, compared with 44 of the 357 patients in the AF group (relative risk 2.05 [1.24 to 3.37], p = 0.003). CONCLUSIONS: Patients who had AF six months after balloon angioplasty or stent implantation experienced more repeat revascularization procedures than those who had CF. They also had significantly more angina at six-month follow-up but this may be due to bias.

Angina Pectoris↗

Stent deformation following simulated side-branch dilatation: a comparison of five stent designs.

We aimed to determine the effects of simulated stent side-branch dilatation and subsequent redilatation of the central lumen. Following coronary stent implantation it may be necessary to dilate through the side of a stent to maintain branch patency. Branch dilatation through the side of 3.5-mm-diameter stents (AVE GFX, beStent, Crown, MultiLink, and NIR) was simulated in a plexiglass phantom using 2.5-, 3.0-, 3.5-, and 4.0-mm balloons. In further experiments, the main lumen was redilated with a 3.5-mm balloon after 3.0-mm side-branch dilatation. Thereafter, a 3.5-mm central and a 3.0-mm side-branch balloon were simultaneously inflated ("kissing balloons"). The larger the balloon size used for side-branch dilatation, the greater the distortion of the stent immediately distal to the side-branch, which for a 4.0-mm balloon ranged from 36% +/- 2% (Crown) to 65% +/- 6% (NIR). Central lumen redilatation or kissing balloons abolished this stenosis with little reduction of the side-lumen diameter. The main stent lumen compromise caused by side-branch dilatation can be abolished by main-lumen redilatation or by kissing balloons.

Catheterization↗

Preliminary experience with the V-flex plus coronary stent: immediate and one-month clinical outcome.

Procedural and 1-month outcome data following implantation of the V-Flex Plus stent in our first 54 consecutive patients (35 male; mean age, 62 years) are described. Sixty-four stents were implanted for 60 mainly complex lesions; 48% were left anterior descending; 20%, circumflex; 27%, right coronary artery; and 5%, saphenous vein graft. The Indication for stenting was elective in half of the patients and for a suboptimal result or as a bailout procedure in the other half. The stents were deployed at a mean of 12 atm (range, 6-18) and postdilatated to a mean of 15 atm (range, 8-20). Pre- and postdilatation balloon sizes were 2.96 +/- 0.57 mm and 3.16 +/- 0.34 mm, respectively. The procedural success rate was 98%. There were no deaths or Q-wave myocardial infarctions. One patient suffered a non-Q-wave myocardial infarction and another developed a femoral false aneurysm. At 1-month follow-up, there were no additional events, in particular no revascularization procedures. Eighty-nine percent of patients were free of angina. Implantation of the V-Flex Plus stent is safe and effective with an excellent early success rate comparable to that of published randomized trials and registries of carefully selected patients.

Adult↗

Results of percutaneous coronary angioplasty in patients <40 years of age.

This study examined factors influencing the outcome of percutaneous transluminal coronary angioplasty (PTCA) in patients <40 years of age. We followed 86 patients (mean age 37 years) treated from 1982 to 1994. The primary procedural success was 90%. At follow-up of 83 patients (97%) at a mean of 48 +/- 33 months (range 5 to 147), there had been 3 late deaths. Actuarial survival at 5 and 10 years was 95% and 91%, respectively. At review only 5% of patients had class III angina and no patient had class IV angina. Repeat revascularization (PTCA alone in 21 [25%], surgery in 8 [10%], or both in 10 [12%] patients) was performed for restenosis in 29 patients (35%) and for disease progression at other sites in 10 patients (12%). On multivariate analysis, a history of diabetes mellitus (p <0.02) was the only factor associated with death or a subsequent cardiovascular event (myocardial infarction, stroke, or hospital admission with unstable angina). At follow-up, 20 patients (24%) still smoked, 64 (77%) had a total cholesterol level > or = 200 mg/dl, 20 (24%) had a body mass index > or = 30, and 15 (18%) were not taking aspirin. In conclusion, PTCA in adults <40 years of age has excellent early results with a low morbidity and mortality. The medium-term prognosis and control of symptoms was good, although by 5 years, further revascularization was required in almost half of the patients.

Adult↗

Late regression of the dilated site after coronary angioplasty: a 5-year quantitative angiographic study.

BACKGROUND: Limited data are available on the changes that occur at the dilated site late after coronary angioplasty. The aim of this study was to evaluate with quantitative angiography the natural history of changes that occur in the dilated segment between "early" (approximately 6 months) and "late" (approximately 5 years) follow-up after angioplasty. METHODS AND RESULTS: Of 127 consecutive patients (174 lesions) with successful angioplasty, 125 underwent early angiography. Three patients subsequently died, and 24 underwent revascularization surgery or repeated angioplasty, giving a study-eligible population of 98 patients. Quantitative angiographic analysis was performed before and immediately after angioplasty and at early and late follow-up in the study population of 84 patients (115 lesions), which was 86% of study-eligible patients. Mean lesion diameter stenosis decreased from 36.3+/-14.2% at early to 29.6+/-13.5% at late follow-up (P<.0001). No lesion developed late restenosis by the 50% diameter loss criterion. Late regression was related to stenosis severity at early angiography (r=-.58, P<.001). Subgroups at early angiography of 40% to 49% stenosis and > or = 50% stenosis showed significant regression at late angiography. CONCLUSIONS: Lesion regression at the dilated site is common late after angioplasty. The more severe a stenosis is at early angiography, the more likely the chance that there will be late regression. A strategy of watchful waiting may be appropriate for patients with restenotic lesions of borderline severity.

Adult↗

Percutaneous rotational coronary atherectomy: initial Green Lane and Mercy hospitals' experience.

AIMS: Rotational atherectomy is a new interventional technique and can be used as an alternative percutaneous treatment for selected coronary atherosclerotic lesions. We report the initial Green Lane/Mercy hospitals experience with rotational atherectomy and review the published international experience with the device. METHODS: Patient case notes and prospectively recorded New Zealand national angioplasty data forms were reviewed for basic demographic data and angina symptoms, in-hospital complications and length of the hospital stay. Catheter laboratory worksheets were reviewed to obtain the duration of ablation, burr diameter and adjunctive PTCA balloon diameter. RESULTS: The main indications for rotational atherectomy were heavy lesion calcification, ostial location, or failure of an angioplasty balloon to cross or to dilate the lesion. Procedural success was achieved in 28 of 30 patients (93%). One patient suffered a Q wave myocardial infarction and in another the lesion could not be crossed with the guide wire. Two patients required repeat balloon angioplasty for early reocclusion without other sequelae and one patient had directional atherectomy 2 weeks later for ongoing sumptoms. CONCLUSION: Rotational atherectomy is a useful adjunct to the percutaneous devices available to treat coronary disease.

Adult↗

Enhanced manipulation of directional coronary atherectomy and coronary angioplasty guide catheters.

Manipulation of thin-walled coronary guiding catheters, especially directional coronary atherectomy guides, may sometimes be difficult. This is particularly so in patients with tortuous or ectatic aorto-iliac arterial systems. To improve torque transmission and eliminate kinking, the introducer catheter or a smaller caliber diagnostic catheter is advanced to within 1.5 cm of the distal guide tip. Connecting the rotating hemostatic valve to the introducer hub or diagnostic catheter proximally allows distal contrast injections and pressure monitoring via this inner catheter. Other methods of enhancing guide catheter manipulation are also discussed.

Atherectomy, Coronary↗

Simultaneous inflation of tandem (sequential) angioplasty balloons: a means of simultaneously treating multiple lesions in one coronary artery.

We report a novel approach to dilating multiple lesions in a coronary artery. Through the same guide and over different wires, a 3.5 mm diameter, 20 mm length, and a 3.0 mm diameter, 90 mm length balloon were simultaneously inflated in a right coronary artery. This approach, which simultaneously treats sequential (tandem) lesions of different diameter and length, allows reduction of both the total duration of ischemia and procedural time and may improve early angiographic outcome.

Angina Pectoris↗