Search PubMed⌕ Search

Biomedical subjects

J A Loo

Publications and source records attributed to J A Loo.

45 records · Page 3Linked to original sources

Capillary isotachophoresis with UV and tandem mass spectrometric detection for peptides and proteins.

The application of capillary isotachophoresis (CITP) and combined CITP-mass spectrometry (MS) for peptides and proteins is demonstrated. Separation of simple peptide mixtures, as well as enzymatic digets of proteins, is also reported using CITP with UV detection. The potential utility of CITP for proteins is demonstrated. Initial studies of combined CITP-MS of enzymatic digests is also demonstrated, showing the potential for rapid sequence determination.

Amino Acid Sequence↗

Capillary zone electrophoresis and isotachophoresis-mass spectrometry of polypeptides and proteins based upon an electrospray ionization interface.

The special capabilities of the capillary electrophoresis electrospray ionization-mass spectrometer interface for the analysis of peptides and proteins with molecular weights extending to in excess of 100,000 are reviewed. The dynamic combinations of both capillary zone electrophoresis and capillary isotachophoresis with electrospray ionization are illustrated for mixtures of peptides and proteins. Myoglobin and cytochrome c detection limits were ca. 100 fmol. The potential extension of these methods for determination of the primary structure (sequence) of polypeptides using tandem mass spectrometry is shown to be facilitated by the high charge state of ions produced by the electrospray interface. The relevance of these results for advances in analytical biochemistry are discussed.

Animals↗

Peptide and protein analysis by electrospray ionization-mass spectrometry and capillary electrophoresis-mass spectrometry.

The extension of mass spectrometry to high molecular weight biopolymers based upon electrospray ionization and the on-line combination with capillary electrophoresis is described. Electrospray ionization produces gas-phase intact multiply charged molecular ions of biomolecules from highly charged liquid droplets by a high electric field. For high molecular weight substances electrospray ionization results in a characteristic bell-shaped distribution of multiply charged ions, with each adjacent major peak in the spectrum differing by one charge. Multiply charged molecular ions of proteins with molecular weights greater than 130,000 have been observed with a quadrupole mass spectrometer of limited mass-to-charge range (m/z 1700). Molecular weights can be readily determined for large proteins with accuracies in the range of +/- 0.01 to 0.05%; at least an order of magnitude further improvement appears feasible with improved techniques and instrumentation. The electrospray ionization method is sensitive, presently requiring samples in the 100 fmol to 10 pmol range for proteins. Initial results combining rapid separations by capillary zone electrophoresis with on-line mass spectrometric detection via the electrospray ionization source are demonstrated for myoglobin and other proteins and polypeptides. The potential for extension of these methods to molecular weights on the order of 10(6) is discussed.

Animals↗

Studying noncovalent protein complexes by electrospray ionization mass spectrometry.

Electrospray ionization mass spectrometry has been used to study protein interactions driven by noncovalent forces. The gentleness of the electrospray ionization process allows intact protein complexes to be directly detected by mass spectrometry. Evidence from the growing body of literature suggests that the ESI-MS observations for these weakly bound systems reflect, to some extent, the nature of the interaction found in the condensed phase. Stoichiometry of the complex can be easily obtained from the resulting mass spectrum because the molecular weight of the complex is directly measured. For the study of protein interactions, ESI-MS is complementary to other biophysical methods, such as NMR and analytical ultracentrifugation. However, mass spectrometry offers advantages in speed and sensitivity. The experimental variables that play a role in the outcome of ESI-MS studies of noncovalently bound complexes are reviewed. Several applications of ESI-MS are discussed, including protein interactions with metal ions and nucleic acids and subunit protein structures (quaternary structure).

Ions↗

High sensitivity mass spectrometric methods for obtaining intact molecular weights from gel-separated proteins.

The molecular weight measurement of intact Escherichia coli proteins separated by isoelectric focusing-immobilized pH gradient (IEF-IPG) gels and analyzed by mass spectrometry is presented. Two methods are discussed: (i) electrospray ionization (ESI) mass spectrometry (MS) of extracted proteins, and (ii) matrix-assisted laser desorption/ionization (MALDI)-MS analysis directly from IEF-IPG gels. Both ESI and MALDI methods yield sub-picomole sensitivity and good mass measurement accuracy. The use of an array detector for ESI-MS was essential to discriminate against contaminating background ions and to selectively detect high mass protein ions. MALDI-MS offers high-throughput analysis of one- and potentially two-dimensional (2-D) gels. The "virtual 2-D" gel method with first-dimensional IEF separation and the second dimension as molecular mass determination by MS, is a particularly promising method for protein analysis due to its ultra high sensitivity and correspondence to classical 2-D gels. Further sensitivity enhancements for the MALDI-MS method are provided by post acceleration detection optimized for high mass time-of-flight analysis.

Bacterial Proteins↗

Sensitivity and mass accuracy for proteins analyzed directly from polyacrylamide gels: implications for proteome mapping.

Matrix-assisted laser desorption ionization (MALDI) mass spectra have been obtained directly from thin-layer isoelectric focusing (IEF) gels with as little as 700 femtomoles of alpha- and beta-chain bovine hemoglobin and bovine carbonic anhydrase, and 2 picomoles of bovine trypsinogen, soybean trypsin inhibitor, and bovine serum albumin all loaded onto a single lane. By soaking the gel in a matrix solution, matrix was deposited over the entire gel surface, allowing MALDI scanning down complete lanes of the one-dimensional gel. As long as matrix crystals were deposited finely on the surface of the gel, time-lag focusing techniques were capable of ameliorating some of the mass accuracy limitations inherent in desorbing from uneven insulator surfaces with external calibration. Eleven measurements on the 5 kDa alpha-subunit proteins of lentil lectin measured over the course of 1 h and referenced to a single calibration yielded a standard deviation of 0.025%. Colloidal gold staining was found to be compatible with desorption directly from IEF and sodium dodecyl sulfate (SDS)-polyacrylamide gels. This direct approach simplifies the interface between gel electrophoresis and mass spectrometry dramatically, making the process more amenable to automation.

Acrylic Resins↗