S5FP: spectrally selective suppression with steady state free precession.

A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further excites the other, which is then suppressed by gradient crushing and RF spoiling. The Spectrally Selective Suppression with SSFP (S(5)FP) method is shown to provide significant attenuation of fat signals, while the water signals are essentially unaffected and provide the normal SSFP contrast. Fat suppression is achieved with relatively little temporal overhead (less than 10% reduction in temporal resolution). S(5)FP was validated using simulations, phantoms, and human studies.

Adipose Tissue↗

Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE.

Parallel imaging applied to first-pass, contrast-enhanced cardiac MR can yield greater spatial coverage for a fixed temporal resolution. The method combines rate R=2 acceleration using TSENSE with shot-to-shot interleaving of two slices. The square root R SNR loss is largely compensated for by a longer effective repetition time (TR) and increased flip angle associated with slice interleaving. In this manner, increased spatial coverage is achieved while comparable or better image quality is maintained. Single-heartbeat temporal resolution was accomplished with spatial coverage of eight slices at heart rates up to 71 bpm, six slices up to 95 bpm, and four slices up to 143 bpm. Experiments in normal subjects (N=6) were performed to assess signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values.

Artifacts↗

Intracranial arteriovenous malformations: real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography--initial assessment.

Auto-triggered elliptic centric-ordered three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography was compared with 3D multiple overlapping thin-slab acquisition time-of-flight (TOF) MR angiography in the evaluation of intracranial arteriovenous malformations (AVMs) in 10 patients. Intraarterial digital subtraction angiography (DSA) was the reference standard. Gadolinium-enhanced MR angiograms were found to be equivalent to DSA images in AVM component depiction in 70%--90% of cases and were consistently superior to TOF MR angiograms.

Adolescent↗

Prostate cancer: MR imaging and thermometry during microwave thermal ablation-initial experience.

Percutaneous interstitial microwave thermoablation of locally recurrent prostate carcinoma was continually guided with magnetic resonance (MR) imaging. Phase images and data were obtained with a rapid gradient-echo technique and were used to derive tissue temperature change on the basis of proton-resonance shift. Thermally devitalized regions correlated well with the phase image findings. MR imaging-derived temperatures were linearly related to the fluoroptic tissue temperatures. MR imaging can be used to guide thermoablation.

Aged↗

Virtual frequency encoding: achieving symmetry in k-space.

Chemical shift artifacts and other off-resonance spatial shifts in 2DFT MRI arise from the linear time dependence in the k-space data in the readout direction. Introduction of a view-dependent time shift of the readout window adds a time dependence to the phase-encoding direction and results in a virtual frequency-encoding direction that is a linear combination of the phase-encode and readout axes. By this method, the readout and phase-encode directions can be made identical in their sensitivity to off-resonance effects and can be arbitrarily swapped with no change in chemical shift or inhomogeneity effects, improving previously reported methods that swap these axes for signal averaging or reduction of motion artifacts.

Artifacts↗

3D autocorrelation for the determination of large pore sizes.

A data analysis methodology is used to process 3D NMR image data acquired for porous systems. The method extracts the mean size of those repeating elements in the image data which are largely compared with the image voxel dimensions. In this work we extend the two-dimensional (2D) image analysis method described by others to three spatial dimensions (3D). 3D image data were acquired at a magnetic field strength of 7 T using NMR microscopy hardware. The 3D autocorrelation function obtained from the data reveals a characteristic pore size in each dimension.

Image Processing, Computer-Assisted↗

Dynamic scan-plane tracking using MR position monitoring.

An MR-based method for tracking subject motion is presented. The technique identifies subject motion from the three-dimensional positions of three small samples attached to the subject in a fixed, triangular configuration. The updated positions of these samples relative to their initial positions determine a rigid body transformation. Applied to the MRI scan prescription via adaptive feedback controls, this transformation yields an updated MRI scan plane that tracks the prescribed imaging section as the subject moves. The scan-plane tracking procedure is demonstrated experimentally for two-dimensional imaging of a standard imaging phantom and the head of a human subject. Sets of images were acquired sequentially, with motion (translations and/or rotations) introduced between image frames. The scan-plane tracking system provides well registered image slices of the same section, adaptively compensating for the subject motion.

Artifacts↗