Search PubMed⌕ Search

Biomedical subjects

J A D'Andrea

Publications and source records attributed to J A D'Andrea.

18 recordsLinked to original sources

Radio frequency radiation of millimeter wave length: potential occupational safety issues relating to surface heating.

Currently, technology is being developed that makes use of the millimeter wave (MMW) range (30-300 GHz) of the radio frequency region of the electromagnetic spectrum. As more and more systems come on line and are used in everyday applications, the possibility of inadvertent exposure of personnel to MMWs increases. To date, there has been no published discussion regarding the health effects of MMWs; this review attempts to fill that void. Because of the shallow depth of penetration, the energy and, therefore, heat associated with MMWs will be deposited within the first 1-2 mm of human skin. MMWs have been used in states of the former Soviet Union to provide therapeutic benefit in a number of diverse disease states, including skin disorders, gastric ulcers, heart disease and cancer. Conversely, the possibility exists that hazards might be associated with accidental overexposure to MMWs. This review attempts to critically analyze the likelihood of such acute effects as burn and eye damage, as well as potential long-term effects, including cancer.

Accidents, Occupational↗

Effects of high peak power microwaves on the retina of the rhesus monkey.

We studied the retinal effects of 1.25 GHz high peak power microwaves in Rhesus monkeys. Preexposure fundus photographs, retinal angiograms, and electroretinograms (ERG) were obtained to screen for normal ocular structure and function and, after exposure, as endpoints of the study. Histopathology of the retina was an additional endpoint. Seventeen monkeys were randomly assigned to receive sham exposure or pulsed microwave exposures. Microwaves were delivered anteriorly to the face at 0, 4.3, 8.4, or 20.2 W/kg spatially and temporally averaged retinal specific absorption rates (R-SAR). The pulse characteristics were 1.04 MW ( approximately 1.30 MW/kg temporal peak R-SAR), 5.59 micros pulse length at 0, 0.59, 1. 18, and 2.79 Hz pulse repetition rates. Exposure was 4 h per day and 3 days per week for 3 weeks, for a total of nine exposures. The preexposure and postexposure fundus pictures and angiograms were all within normal limits. The response of cone photoreceptors to light flash was enhanced in monkeys exposed at 8.4 or 20.2 W/kg R-SAR, but not in monkeys exposed at 4.3 W/kg R-SAR. Scotopic (rod) response, maximum (combined cone and rod) response, and Naka-Rushton R(max) and log K of scotopic b-waves were all within normal range. Retinal histopathology revealed the presence of enhanced glycogen storage in photoreceptors among sham (2/5), 8.4 W/kg (3/3), and 20.2 W/kg (2/5) exposed monkeys, while enhanced glycogen storage was not observed in the 4.3 W/kg (0/4) exposed group. Supranormal cone photoreceptor b-wave was R-SAR dependent and may be an early indicator of mild injury. However no evidence of degenerative changes and ERG depression was seen. We concluded that retinal injury is very unlikely at 4 W/kg. Functional changes that occur at higher R-SAR are probably reversible since we saw no evidence of histopathologic correlation with ERG changes. Bioelectromagnetics 21:439-454, 2000. Published 2000 Wiley-Liss, Inc.

Absorption↗

Behavioral evaluation of microwave irradiation.

Establishing safe exposure levels for microwave irradiation is important since new, more powerful emitters are developed and the potential for accidental exposure is increasing. Analysis of the behavior of exposed laboratory animals has proven to be an accurate and repeatable metric for assessing the effects of microwave irradiation. Determining the specific absorption rate (SAR) at which an animal will cease an ongoing behavior has proven useful in the development of safe exposure levels for humans. Behaviors that have been used are simple tasks, and the point at which behavior changes significantly or ceases has often been referred to as "work stoppage." The tasks have been used to evaluate the overwhelming effects of heating produced by microwave irradiation. Both whole-body exposures and partial-body exposures with hotspots have been evaluated. Recent studies have suggested that microwave effects on specific cognitive aspects of behavior such as attention, learning, memory, discrimination, and time perception may occur at SAR levels far below the SARs needed to cause work stoppage. New research studies are underway to evaluate microwave-induced cognitive effects.

Absorption↗

Massachusetts Risk Management Survey (MaRMS) of teaching hospital physicians.

OBJECTIVE: To assess and compare the risk management knowledge of physicians from Massachusetts teaching hospitals. DESIGN: A survey. SETTING: Participating Massachusetts teaching hospitals. PARTICIPANTS: 639 of some 2,000 staff physicians of participant hospitals who were sent surveys. An additional 174 postgraduate year 1 (PGY1) and PGY3 house officers also completed the survey. MAIN OUTCOME MEASURES: Percent of questions answered correctly, and comparisons between staff physicians and house officers. RESULTS: Staff physicians scored higher (87%) than PGY1s and PGY3s combined (81%), P<0.001. Scores among staff physicians did not differ according to field of medicine, age, proportion of time spent in clinical practice, or years in practice. PGY3s did not score significantly higher than PGY1s (82% vs. 80%). Some 40% of physicians said they ordered more tests than necessary because of malpractice worries; they indicated 72% of their colleagues do so as well. Physicians in obstetrics-gynecology and emergency medicine were more likely to respond yes to this question than physicians in other fields of medicine (P<0.001), as were physicians who had been defendants in a malpractice suit (88 P=0.013). CONCLUSIONS: Surveyed staff physicians have an adequate risk management knowledge. Training directors should encourage house officers to attend risk management programs to improve their knowledge. Physicians might overestimate the amount spent on defense medicine based on their perceptions of other physicians.

Adult↗

Rhesus monkey behavior during exposure to high-peak-power 5.62-GHz microwave pulses.

Limits on the exposure to high-peak-power, short-duration microwave pulses have only recently been adopted. Additional data, however, are needed to understand the effects that may be produced by exposure to high-peak-power pulsed microwaves. Four male rhesus monkeys (Macaca mulatta) were trained on an operant task for food pellet reward to investigate the behavioral effects of very high-peak-power 5.62 GHz microwaves. The operant task required monkeys to pull one plastic lever on a variable interval schedule (VI-25 s) and then respond to color signals and pull a second lever to obtain food. The monkeys were conditioned to perform a color discrimination task using one of three colors displayed by a fiber-optic cable. A red signal was the discriminative stimulus for responding on the first lever. A response on the second lever when a green signal was presented (1 s duration) delivered a food pellet. If a response on the second lever was made in the presence of a white signal, a 30-s timeout occurred. While performing the behavioral task, the monkeys were exposed to microwave pulses produced by either a military radar (FPS-26A) operating at 5.62 GHz or the same radar coupled to a Stanford linear energy doubler (SLED) pulse-forming device (ITT-2972) that enhanced peak power by a factor of nine by adding a high power pulse to the radar pulse. The effects of both types of pulses were compared to sham exposure. Peak field power densities tested were 518, 1270, and 2520 W/cm2 for SLED pulses and 56, 128, and 277 W/cm2 for the radar pulses. The microwave pulses (radar or SLED) were delivered at 100 pps (2.8 microseconds radar pulse duration; approximately 50 ns SLED pulse duration) for 20 min and produced averaged whole-body SARs of 2, 4, or 6 W/kg. Compared to sham exposures, significant alterations of lever responding, reaction time, and earned food pellets occurred during microwave exposure at 4 and 6 W/kg but not at 2 W/kg. There were no differences between radar or SLED pulses in producing behavioral effects.

Analysis of Variance↗

Microwave radiation absorption: behavioral effects.

The literature contains much evidence that absorption of microwave energy will lead to behavioral changes in man and laboratory animals. The changes include simple perturbations or outright stoppage of ongoing behavior. On one extreme, intense microwave absorption can result in seizures followed by death. On the other extreme, man and animals can hear microwave pulses at very low rates of absorption. Under certain conditions of exposure, animals will avoid microwaves, while under other conditions, they will actively work to obtain warmth produced by microwaves. Some research has shown behavioral effects during chronic exposure to low-level microwaves. The specific absorption rates that produce behavioral effects seem to depend on microwave frequency, but controversy exists over thresholds and mechanism of action. In all cases, however, the behavioral disruptions cease when chronic microwave exposure is terminated. Thermal changes in man and animals during microwave exposure appear to account for all reported behavioral effects.

Animals↗

Lack of behavioral effects in the rhesus monkey: high peak microwave pulses at 1.3 GHz.

The current safety standards for radiofrequency and microwave exposure do not limit the peak power of microwave pulses for general or occupational exposures. While some biological effects, primarily the auditory effect, depend on pulsed microwaves, hazards associated with very high peak-power microwave pulses in the absence of whole-body heating are unknown. Five rhesus monkeys, Macaca mulatta, were exposed to peak-power densities of 131.8 W/cm2 (RMS) while performing a time-related behavioral task. The task was composed of a multiple schedule of reinforcement consisting of three distinct behavioral components: inter-response time, time discrimination, and fixed interval. Trained monkeys performed the multiple schedule during exposure to 1.3-GHz pulses at low pulse-repetition rates (2-32 Hz). No significant change was observed in any behavior during irradiation as compared to sham-irradiation sessions. Generalization of these findings to experimental results with higher peak-power densities, other pulse rates, different carrier frequencies, or other behaviors is limited.

Animals↗

Reduced exposure to microwave radiation by rats: frequency specific effects.

Previous research has shown that SAR "hotspots" are induced within the laboratory rat and that the resulting thermal hotspots are not entirely dissipated by bloodflow. Two experiments were conducted to determine if hotspot formation in the body and tail of the rat, which is radiation frequency specific, would have behavioral consequences. In the first experiment rats were placed in a plexiglas cage one side of which, when occupied by the rat, commenced microwave radiation exposure; occupancy of the other side terminated exposure. Groups of rats were tested during a baseline period to determine the naturally preferred side of the cage. Subsequent exposure to 360-MHz, 700-MHz or 2450-MHz microwave radiation was made contingent on preferred-side occupancy. A significant reduction in occupancy of the preferred side of the cage, and hence, microwaves subsequently occurred. Reduced exposure to 360-MHz and 2450-MHz microwaves at 1, 2, 6 and 10 W/kg were significantly different from 700-MHz microwaves. In the second experiment semichronic exposures revealed the threshold for reduced exposure of 2450-MHz microwaves to be located between whole-body SAR's of 2.1 and 2.8 W/kg.

Animals↗

Behavioral effects of chronic exposure to 0.5 mW/cm2 of 2,450-MHz microwaves.

Adult male, Long-Evans rats were exposed 7 h a day for 90 days to continuous wave (CW) 2,450-MHz microwaves at an average power density of 0.5 mW/cm2. Exposures were in a monopole-above-ground radiation chamber with rats in Plexiglas cages. The resulting specific absorption rate (SAR) was 0.14 W/kg (+/- 0.01 SEM). Additional rats served as sham-exposed and home-caged controls. All were evaluated daily for body mass and food and water intakes. Once each 30 days, throughout baseline and exposure phases of the experiment, rats in the sham- and microwave-exposed groups were tested for their sensitivity to footshock. After 90-days of exposure, the rats were evaluated an open field, an active avoidance task and an operant task for food reinforcement. Performance of sham- and microwave-irradiated rats was reliably different on only one measure, the lever-pressing task. The general conclusion reached was that exposure to CW 2,450-MHz microwave radiation at 0.5 mW/cm2 was below the threshold for behavioral effects over a wide range of variables, but did have an effect on a time-related operant task, although the direction of the effect was unpredictable.

Animals↗

Absorption of microwave radiation by the anesthetized rat: electromagnetic and thermal hotspots in body and tail.

Anatomic variability in the deposition of radiofrequency electromagnetic energy in mammals has been well documented. A recent study [D'Andrea et al., 1985] reported specific absorption rate (SAR) hotspots in the brain, rectum and tail of rat carcasses exposed to 360- and to 2,450-MHz microwave radiation. Regions of intense energy absorption are generally thought to be of little consequence when predicting thermal effects of microwave irradiation because it is presumed that heat transfer via the circulatory system promptly redistributes localized heat to equilibrate tissue temperature within the body. Experiments on anesthetized, male Long-Evans rats (200-260 g) irradiated for 10 or 16 min with 2,450, 700, or 360 MHz radiation at SARs of 2 W/kg, 6 W/kg, or 10 W/kg indicated that postirradiation localized temperatures in regions previously shown to exhibit high SARs were appreciably above temperatures at body sites with lower SARs. The postirradiation temperatures in the rectum and tail were significantly higher in rats irradiated at 360 MHz and higher in the tail at 2,450 MHz than temperatures resulting from exposure to 700 MHz. This effect was found for whole-body-averaged SARs as low as 6 W/kg at 360 MHz and 10 W/kg at 2,450 MHz. In contrast, brain temperatures in the anesthetized rats were not different from those measured in the rest of the body following microwave exposure.

Animals↗

Behavioral and physiological effects of chronic 2,450-MHz microwave irradiation of the rat at 0.5 mW/cm2.

Adult male Long-Evans rats were intermittently exposed to 2450 MHz CW microwaves at an average power density of 0.5 mW/cm2 for 90 days. The resulting SAR was 0.14 W/kg (range 0.11 to 0.18 W/kg). The animals were exposed 7 h/day, 7 days/wk, for a total of 630 h in a monopole-above-ground radiation chamber while housed in Plexiglas holding cages. Daily measures of body mass and food and water intake indicated no statistically significant effects of microwave exposure. Monthly assessment of reactivity to electric footshock, levels of cholinesterase and sulfhydryl groups in blood, and 17-ketosteroids in urine revealed no reliable differences between 14 sham-exposed and 14 microwave-exposed rats. After the 90 days of exposure, seven rats, randomly chosen from each group, were assessed for open-field behavior, shuttlebox performance, and schedule-controlled (IRT schedule) lever pressing for food pellets. Statistically significant differences between microwave-exposed and sham-exposed rats were observed in shuttlebox performances and lever pressing. Post mortem measures of mass of several organs and microscopic examination of adrenal tissue revealed no differences between the two groups of animals.

17-Ketosteroids↗

Intermittent exposure of rats to 2450 MHz microwaves at 2.5 mW cm2: behavioral and physiological effects.

Long-Evans male adult rats were intermittently exposed for 14 weeks to continuous wave (CW) 2450-MHz microwaves at an average power density of 2.5 mW/cm2. The mean specific absorption rate was 0.70 W/kg (+/- 0.02 SEM). The rats were exposed 7 h/day, 7 days/week in a radiation chamber with a monopole above ground, while housed in Plexiglas cages. Weekly measures of body mass and food intake did not indicate statistically significant effects of microwave irradiation. Assessments of threshold for electric-footshock detection revealed a significant difference between microwave and sham-exposed animals. Assessments of cholinesterase and sulfhydryl groups in blood and 17-ketosteroids in urine did not distinguish the two groups of rats. Behavioral measures made at the end of the 14-week exposure included an open-field test, shuttlebox avoidance performance, and schedule-controlled lever-pressing for food pellets. Statistically significant differences between microwave- and sham-exposed rats were observed for these measures. Examination of adrenal tissue, plasma electrolytes, and organ masses after 14 weeks of exposure revealed no difference between the two groups of rats.

17-Ketosteroids↗

Microwave radiation absorption in the rat: frequency-dependent SAR distribution in body and tail.

Experiments were conducted using twin-well calorimetry to determine the averaged whole-body specific absorption rate (SAR) for rat carcasses exposed to 360, 700, 915, and 2,450 MHz CW radiation in an anechoic chamber. All exposures were done with the long axis of the rat in an E-polarization. Additional experiments were conducted using a fiber optical temperature probe to determine local SAR in the brain, esophagus, colon, rectum, and tail during microwave exposure. The whole-body averaged SAR for the radiation frequencies examined follows a nonmonotonic function with 700 MHz as the resonant frequency. This result agrees with previous analytical estimates. Local SARs within the body and tail are nonuniform with significant frequency-specific hotspots in the colon, rectum, and tail.

Animals↗

Physiological and behavioral effects of prolonged exposure to 915 MHz microwaves.

Long-Evans male adult rats were exposed for 16 weeks to 915-MHz CW microwaves at an average power density of 5 mW/cm2. The resulting dose rate was 2.46 (+/- 0.29 SEM) mW/g. The animals were exposed eight hours a day, five days a week, for a total of 640 h in a monopole-above ground radiation chamber while housed in Plexiglas cages. Daily measures of body mass and of food and water intake indicated no statistically significant effects of microwave irradiation. Measures by activity wheels and stabilimetric platforms of spontaneous locomotion indicate than mean activity levels increased about 25% after microwave exposure, but the findings are doubtful statistical significance (Ps < .10 but > .05). Studies of blood sampled after 2, 6, 10, and 14 weeks of exposure revealed alterations of free sulfhydryls. Measures of levels of urinary 17-ketosteroids at weeks 1, 5, 9, and 12 of exposure, and measures of brain hypothalamic tissue, and of mass of adrenals, heart, and liver at the end of the 16-week period, revealed no significant differences between irradiated and control animals. Cortical EEGs sampled after conclusion of microwave exposures also revealed no significant differences.

17-Ketosteroids↗

Behavioral effects of strong 60-Hz electric fields in rats.

Eight individually housed male Long Evans rats were raised, beginning at age 30 days, for six weeks in an electric field exposure apparatus. During five of the six weeks, the animals were exposed to a 25 kV/m, 60-Hz electric field. A similar population of rats housed in an identical environment, except for the absence of the high voltage field, were used as control animals. Differences between the two groups in body mass, food and water intake, and exploratory activity were studied. Statistical analysis shows the high voltage fields to have no significant effects on the above parameters.

Animals↗

Physiological and behavioral effects of chronic exposure to 2450-MHz microwaves.

Long-Evans male adult rats were exposed for sixteen weeks to 2450-MHz CW microwaves at an average power density of mW/cm2. The resulting dose rate was 1.23 (+/- 0.25SEM) mW/g. The animals were exposed eight hours a day, five days a week, for a total of 640 h in a monopole-above-ground radiation chamber while housed in Plexiglas holding cages. Daily measures of body mass and of food and water intakes indicated no statistically significant effects of microwave irradiation. Biweekly stabilimetric tests immediately after exposure revealed a significant depression of behavioral activity by 15 microwave-exposed rats as compared with 15 sham-exposed animals. Measures of locomotor activity based on revolutions of a running wheel, which were obtained during 12-h periods between each 8-h exposure, showed no significant effect of irradiation. Blood sampled after 2, 6, 10, and 14 weeks of exposure indicated slight alterations of sulfhydryl groups, and of red and white blood-cell counts. Measures of levels of 17-ketosteroids in urine at weeks 1, 5, 9, and 12 of exposure, and mass of adrenals, heart, and liver at the end of the sixteen-week period of exposure, revealed no indications of stress.

Animals↗