Noncontrast MR imaging and MR arthrography of the ulnar collateral ligament of the elbow: prospective evaluation of two-dimensional pulse sequences for detection of complete tears.

OBJECTIVE: To compare MR imaging techniques with differing contrast and spatial resolution for evaluation of complete disruption of the ulnar collateral ligament (UCL) anterior bundle in a cadaveric elbow model. DESIGN: Complete UCL tears were surgically created at the typical location for clinical tears in eight of 28 fresh frozen cadaveric elbow specimens. All specimens underwent 1.5 T MR imaging in the oblique coronal plane, using an extremity coil. The sequences employed were: T1-weighted spin echo (T1 SE), proton density-weighted (PD) fast spin echo (FSE), fat-suppressed T2-weighted FSE (T2 FSE), gradient recalled echo (GRE) with a high matrix, PD FSE with a high matrix (HRPD), and fat suppressed T1-weighted SE with intra-articular gadolinium (MRAr). Two radiologists independently graded the UCL with separate and side-by-side assessments. RESULTS: Sensitivity/specificity pairs were as follows for reader A and reader B, respectively: T1 SE: 0.25/0.95, 0.50/0.95; PD FSE: 0.38/1.00, 0.25/1.00; T2 FSE: 0.50/0.95, 0.63/0.95; GRE: 0.63/0.85, 0.63/0.60; MRAr: 0.88/1.00, 1.00/0.80; HRPD: 0.50/1.00, 0.88/0.80. Kappa statistics for measuring interobserver reliability for each sequence were poor under T1 SE (-0.13) and GRE (0.19), moderate under HRPD (0.41) and T2 FSE (0.44) and good under MRAr (0.62) and PD FSE (0.78). For both readers, the rating for overall image quality was highest for HRPD, and the rating for UCL lesion conspicuity was the highest for MRAr. CONCLUSIONS: Of the MR imaging pulse sequences tested, MRAr showed the greatest ability to identify complete ligamentous injuries with good agreement between readers and had the highest subjective preference for lesion conspicuity. However, HRPD had the least interobserver variability and the highest subjective preference for overall image quality.

Aged↗

Lateral ulnar collateral ligament of the elbow: optimization of evaluation with two-dimensional MR imaging.

PURPOSE: To compare, in a cadaveric model, magnetic resonance (MR) imaging techniques with differing contrast and spatial resolution properties in the evaluation of disruption of the lateral ulnar collateral ligament (LUCL) at the elbow. MATERIALS AND METHODS: LUCL tears were surgically created in eight of 28 cadaveric elbow specimens. All specimens underwent 1.5-T MR imaging with the following pulse sequences: T1-weighted spin echo (SE), intermediate-weighted fast SE, fat-suppressed T2-weighted fast SE, gradient-recalled echo (GRE) with high spatial resolution, intermediate-weighted fast SE with high spatial resolution, and fat-suppressed T1-weighted SE with intraarticular administration of gadopentetate dimeglumine (MR arthrography). All images were obtained in the oblique coronal plane. Two radiologists independently graded the LUCL with separate and side-by-side assessment. RESULTS: Areas under the receiver operating characteristic curve were as follows for readers A and B, respectively: T1-weighted SE imaging, 0.64 and 0.62; intermediate-weighted fast SE imaging, 0.87 and 0.67; T2-weighted fast SE imaging, 0.68 and 0.69; GRE imaging, 0.56 and 0.68; MR arthrography, 0.84 and 0.85; and intermediate-weighted imaging with high spatial resolution, 0.92 and 0.88. Interobserver reliability was poor with T1-weighted SE imaging (kappa = 0.13) and GRE imaging (kappa = 0.18), fair with T2-weighted fast SE imaging (kappa = 0.36), and moderate with MR arthrography (kappa = 0.46), intermediate-weighted fast SE imaging (kappa = 0.55), and intermediate-weighted imaging with high spatial resolution (kappa = 0.59). CONCLUSION: Intermediate-weighted imaging with high spatial resolution and MR arthrography showed the greatest overall ability to enable the diagnosis of LUCL tears.

Aged↗

Subtendinous bone marrow edema patterns on MR images of the ankle: association with symptoms and tendinopathy.

OBJECTIVE: We sought to describe a pattern of subtendinous bone marrow edema on MR images of the ankle and to determine if there is an association with location of symptoms and overlying tendinopathy. MATERIALS AND METHODS: At 1.5 T, 141 MR examinations of the ankle (116 clinical examinations of patients with chronic pain, 25 of asymptomatic control patients) were performed using T1-weighted, proton density-weighted fast spin-echo, and T2-weighted fat-suppressed fast spin-echo sequences. Images were retrospectively reviewed by two musculoskeletal radiologists for presence of bone marrow edema occurring in a subcortical location associated with the course of the medial or lateral tendon groups, as well as focal thickening or increased T2 signal within the tendons. These findings were correlated with clinical information regarding symptom location. The association of subtendinous marrow edema with tendinopathy and symptom location was statistically analyzed. RESULTS: Subtendinous bone marrow edema was present at 26 sites on 24 ankle MR examinations (17%) (at the medial malleolus [n = 17] associated with the posterior tibialis tendon, at the lateral malleolus [n = 6] and the calcaneus [n = 2] associated with the peroneus longus and brevis tendons, and at the cuboid [n = 1] associated with the peroneus longus tendon). These subtendinous bone marrow edema patterns were significantly associated with overlying tendon abnormality medially (p = 0.001) and laterally (p = 0.001), and with symptoms medially (p = 0.0016) but not laterally (p = 0.078). CONCLUSION: On MR images of the ankle, bone marrow edema localized in a subtendinous location is associated with overlying tendinopathy medially and laterally and with ankle pain medially.

Adult↗

Modality interfacing: the impact of a relay station.

We evaluated the effect of a deploying a relay station on demographic discrepancies, image segmentation for routing, quality control (QC), and technologist workflow in a distributed architecture type picture archiving and communication system (PACS) environment. A currently existing PACS environment for computed tomography (CT) was evaluated before and after the implementation of a relay station for demographic error-rate and correct study routing to the workstations. Assessment of the technologists' perceptions with respect to numerous workflow factors was performed with a questionnaire. Statistical analysis was performed using a chi-square test. The demographic error rate for CT examinations was nearly abolished with relay station deployment (14.0% pre-Relay v 0.55% post-Relay, P < .001, chi2). The technologists' perception was favorable, with a substantial majority indicating that a positive impact is made on correcting demographic errors (90%), facilitating QC (67%), and ensuring proper routing (77%). A majority also felt the user interface was intuitive (93.3%) and preferred relay (90%) over film handling but that training should be provided both by didactic sessions and "hands on" time with a trainer. The times to perform tasks were favorable for the relay station (1 to 5 minutes) versus film production and handling (2 to 15 minutes). In conclusion, the relay station prospectively eliminates demographic errors, effectively segments images from the same study routing them to different workstations, and can be seamlessly integrated into the technologists' current workflow. This can be scalable and a lower cost solution as opposed to deploying dedicated PACS QC workstations.

Academic Medical Centers↗

Pectoralis major muscle and tendon tears: diagnosis and grading using magnetic resonance imaging.

OBJECTIVE: To assess the accuracy and utility of magnetic resonance (MR) imaging in the detection and grading of pectoralis major muscle and tendon tears. DESIGN AND PATIENTS: A retrospective review was carried out of 10 patients referred for MR imaging for suspected pectoralis muscle injury and possible operative therapy. The pectoralis muscle and tendon were imaged using thin (3-4 mm) axial sections with a variety of sequences combined for anatomical delineation (T1-weighted SE or PD SE) and fluid detection (T2-weighted SE, T2-weighted FSE with fat suppression, or STIR). Surgical correlation was available in six patients. Clinical follow-up was available in four patients treated by nonoperative therapy. RESULTS: MR imaging identified five complete tears, four partial tears and one normal tendon. One complete and one partial tear were at the myotendinous junction. The remaining seven injuries were at the enthesis. Surgical correlation consisted of five complete tears and one partial tear. One complete and one partial tear were at the myotendinous junction with the remaining four complete tears at the enthesis. The MR interpretation and surgical findings were in agreement in all six cases. All four patients treated with nonoperative therapy demonstrated improvement at a clinical follow-up examination, with restoration of function and strength consistent with a healed prior partial injury. CONCLUSION: MR imaging is accurate and useful in detecting and grading tears involving the pectoralis major muscle and tendon, facilitating the identification of patients with complete tears who are candidates for operative therapy.

Adolescent↗

Direct MR arthrography of the shoulder: is exercise prior to imaging beneficial or detrimental?

PURPOSE: To define the beneficial and detrimental effects of adding exercise to direct magnetic resonance (MR) shoulder arthrography. MATERIALS AND METHODS: Direct, intraarticular, gadolinium arthrography of the shoulder was performed in 41 patients, who underwent 1.5-T MR imaging before and after 1 minute of arm swinging. Fourteen milliliters of dilute gadolinium solution was injected. Two readers blinded to exercise independently graded the randomly distributed images with a five-point scale for capsular contrast material resorption; extraarticular contrast material leakage; rotator cuff, glenoid labrum, and anterior capsule conspicuity; and partial-thickness or full-thickness rotator cuff tear and labral tear detectability. The sign test was performed to evaluate the significance of differences between preexercise and postexercise grading for each reader. A second review was performed, with direct side-by-side comparison of preexercise and postexercise images. RESULTS: There was evidence of increased capsular resorption after exercise but no alteration in the depiction of the rotator cuff tendons or glenoid labrum. There was no significant extraarticular contrast material leakage after exercise and no alteration in depiction of the anterior capsule. There was no difference in the detectability of rotator cuff or labral tears. CONCLUSION: Exercise with direct shoulder MR arthrography has no beneficial or detrimental effect on image quality or on the depiction of rotator cuff or labral tears.

Adolescent↗

Process reengineering: the role of a planning methodology and picture archiving and communications system team building.

The acquisition of a picture archiving and communications system (PACS) is an opportunity to reengineer business practices and should optimally consider the entire process from image acquisition to communication of results. The purpose of this presentation is to describe the PACS planning methodology used by the Department of Defense (DOD) Joint Imaging Technology Project Office (JITPO), outline the critical procedures for each phase, and review the military experience using this model. The methodology is segmented into four phases: strategic planning, clinical scenario planning, installation planning, and implementation planning. Each is further subdivided based on the specific tasks that need to be accomplished within that phase. By using this method, an institution will have clearly defined program goals, objectives, and PACS requirements before vendors are contacted. The development of an institution-specific PACS requirement should direct the process of proposal comparisons to be based on functionality and exclude unnecessary equipment. This PACS planning methodology is being used at more than eight DOD medical treatment facilities. When properly executed, this methodology facilitates a seamless transition to the electronic environment and contributes to the successful integration of the healthcare enterprise. A crucial component of this methodology is the development of a local PACS planning team to manage all aspects of the process. A plan formulated by the local team is based on input from each department that will be integrating with the PACS. Involving all users in the planning process is paramount for successful implementation.

Computer Systems↗

Extraskeletal osteochondroma of the foot.

A case of pathologically proven extraskeletal osteochondroma is presented with magnetic resonance imaging (MRI), computed tomography (CT), bone scan and radiographic findings. The diagnosis of extraskeletal osteochondroma should be considered when a discrete, ossified mass is localized in the soft tissues of the distal extremities. Nomenclature surrounding this entity is controversial and is discussed.

Adolescent↗

Large-scale PACS implementation.

The transition to filmless radiology is a much more formidable task than making the request for proposal to purchase a (Picture Archiving and Communications System) PACS. The Department of Defense and the Veterans Administration have been pioneers in the transformation of medical diagnostic imaging to the electronic environment. Many civilian sites are expected to implement large-scale PACS in the next five to ten years. This presentation will related the empirical insights gleaned at our institution from a large-scale PACS implementation. Our PACS integration was introduced into a fully operational department (not a new hospital) in which work flow had to continue with minimal impact. Impediments to user acceptance will be addressed. The critical components of this enormous task will be discussed. The topics covered during this session will include issues such as phased implementation, DICOM (digital imaging and communications in medicine) standard-based interaction of devices, hospital information system (HIS)/radiology information system (RIS) interface, user approval, networking, workstation deployment and backup procedures. The presentation will make specific suggestions regarding the implementation team, operating instructions, quality control (QC), training and education. The concept of identifying key functional areas is relevant to transitioning the facility to be entirely on line. Special attention must be paid to specific functional areas such as the operating rooms and trauma rooms where the clinical requirements may not match the PACS capabilities. The printing of films may be necessary for certain circumstances. The integration of teleradiology and remote clinics into a PACS is a salient topic with respect to the overall role of the radiologists providing rapid consultation. A Web-based server allows a clinician to review images and reports on a desk-top (personal) computer and thus reduce the number of dedicated PACS review workstations. This session will focus on effective strategies for a seamless transition. Critical issues involve maintaining a good working relationship with the vendor, cultivating personnel readiness and instituting well-defined support systems. Success depends on the ability to integrate the institutional directives, user expectations and available technologies. A team approach is mandatory for success.

Computer Communication Networks↗

Rotator cuff: evaluation with fast spin-echo versus conventional spin-echo MR imaging.

PURPOSE: To determine if fast spin-echo (SE) magnetic resonance (MR) imaging can provide similar information to that of conventional SE imaging for evaluation of the rotator cuff. MATERIALS AND METHODS: One hundred twenty-six patients underwent MR imaging with conventional SE and non-fat-suppressed fast SE sequences (65 patients) or conventional SE and fat-suppressed fast SE sequences (61 patients). Two radiologists independently graded the rotator cuff with separate and side-by-side assessment of the fast SE and conventional SE images. RESULTS: For detection of full-thickness tears, agreement between non-fat-suppressed fast SE and conventional SE images was 93.8% (kappa = 0.78 [good]) and 95.4% (kappa = 0.82 [very good]) for the two readers, respectively, and agreement between fat-suppressed fast SE and conventional SE images was 98.4% (kappa = 0.96 [very good]) and 91.8% (kappa = 0.73 [good]) for the two readers, respectively. Rotator cuff grading was similar for fast SE and conventional SE: weighted kappa = 0.77 (good) and 0.68 (good) for non-fat-suppressed and weighted kappa = 0.83 (very good) and 0.67 (good) for fat-suppressed fast SE images for the two readers, respectively. CONCLUSION: Fast SE sequences yield similar interpretations as those obtained with a conventional SE sequence for evaluation of the rotator cuff.

Adolescent↗