Search PubMed⌕ Search

Biomedical subjects

Ivan Maynart Tavares

Publications and source records attributed to Ivan Maynart Tavares.

2 recordsLinked to original sources

[Normal tension glaucoma].

Normal tension glaucoma is an optic neuropathy in which the retinal nerve fiber layer thickness is reduced, the optic nerve is pathologically excavated, and the visual field is disturbed, although intraocular pressure is classified as normal. Patients with normal tension glaucoma are a heterogeneous group in which many systemic pathologic conditions may be present, and presenting ocular clinical signs that are difficult to be identified in the early stages of the disease. Treatment is more challenging than in hypertensive glaucomas. The authors sought to review the pathophysiology and differential diagnosis of this condition assessing vascular, rheumatic, neurological and genetic aspects that should be studied, as well as its treatment. The sources of references are PubMed (MEDLINE), LILACS and Cochrane Library (CENTRAL) databases.

Diagnosis, Differential↗

No changes in anatomical and functional glaucoma evaluation after trabeculectomy.

PURPOSE: To assess the influence of glaucoma filtration surgery on anatomical and functional tests for glaucoma evaluation. METHODS: Twenty-five eyes (25 patients) with primary open-angle glaucoma were evaluated, prospectively. Data were collected on vision acuity, intraocular pressure, standard automated perimetry, frequency doubling technology perimetry, scanning laser polarimetry (GDx) and confocal scanning laser ophthalmoscopy (HRT II) before and 3-6 months after surgery. RESULTS: Mean (+/-SD) pre- and postoperative visual acuities (logMAR) were 0.28 (+/-0.18) and 0.30 (+/-0.17), respectively (P=0.346). In a mean time of 4.5 (+/-1.1) months after surgery, the mean preoperative intraocular pressure of 20.7 (+/-5.4) mmHg decreased to 11.04 (+/-2.52) mmHg (P<0.001). The results of the standard automated perimetry, frequency doubling technology perimetry, scanning laser polarimetry and confocal scanning laser ophthalmoscopy diagnostic methods revealed no significant difference (P>0.162) between pre and postoperative values and no significant correlation (P>0.296) between intraocular pressure reduction and value changes. CONCLUSION: No significant change on any test variable was detected after glaucoma filtration surgery. Trabeculectomy does not appear to influence standard automated perimetry, frequency doubling technology perimetry, scanning laser polarimetry and confocal scanning laser ophthalmoscopy (HRT II) results after a 4.5-month period of surgery in early to moderate glaucoma.

Female↗