Search PubMed⌕ Search

Biomedical subjects

Istvan Naday

Publications and source records attributed to Istvan Naday.

2 recordsLinked to original sources

The Structural Biology Center 19ID undulator beamline: facility specifications and protein crystallographic results.

The 19ID undulator beamline of the Structure Biology Center has been designed and built to take full advantage of the high flux, brilliance and quality of X-ray beams delivered by the Advanced Photon Source. The beamline optics are capable of delivering monochromatic X-rays with photon energies from 3.5 to 20 keV (3.5-0.6 A wavelength) with fluxes up to 8-18 x 10(12) photons s(-1) (depending on photon energy) onto cryogenically cooled crystal samples. The size of the beam (full width at half-maximum) at the sample position can be varied from 2.2 mm x 1.0 mm (horizontal x vertical, unfocused) to 0.083 mm x 0.020 mm in its fully focused configuration. Specimen-to-detector distances of between 100 mm and 1500 mm can be used. The high flexibility, inherent in the design of the optics, coupled with a kappa-geometry goniometer and beamline control software allows optimal strategies to be adopted in protein crystallographic experiments, thus maximizing the chances of their success. A large-area mosaic 3 x 3 CCD detector allows high-quality diffraction data to be measured rapidly to the crystal diffraction limits. The beamline layout and the X-ray optical and endstation components are described in detail, and the results of representative crystallographic experiments are presented.

Crystallography, X-Ray↗

High-sensitivity CCD-based X-ray detector.

The detector is designed for imaging measurements requiring relatively high sensitivity and high spatial resolution. The detector can discriminate single X-ray photons, yet has the wide dynamic range ( approximately 10000:1) associated with integrating detectors. A GdO2S2 phosphor screen converts the incoming X-ray image into an optical image. The optical image is coupled (without demagnification) to the CCD image sensor using a fiber optic faceplate. The CCD (Philips Semiconductors) has an area of 4.9 x 8.6 cm with 4000 x 7000 12 microm pixels. A single 12 keV X-ray photon produces a signal of 100 e-. With 2 x 2 pixel binning, the total noise per 24 microm pixel in a 100 s image is approximately 30 e- the detective quantum efficiency is >0.6 at 1 X-ray photon per pixel, and the full image can be read out in <4 s. The spatial resolution is 50 microm. The CCD readout system is fully computer-controlled, allowing flexible operation in time-resolved experiments. The detector has been characterized using visible-light images, X-ray images and time-resolved muscle diffraction measurements.

Actin Cytoskeleton↗