Search PubMed⌕ Search

Biomedical subjects

Igor R Efimov

Publications and source records attributed to Igor R Efimov.

At least 19 recordsLinked to original sources

Differences between left and right ventricular chamber geometry affect cardiac vulnerability to electric shocks.

Although effects of shock strength and waveform on cardiac vulnerability to electric shocks have been extensively documented, the contribution of ventricular anatomy to shock-induced polarization and postshock propagation and thus, to shock outcome, has never been quantified; this is caused by lack of experimental methodology capable of mapping 3-D electrical activity. The goal of this study was to use optical imaging experiments and 3-D bidomain simulations to investigate the role of structural differences between left and right ventricles in vulnerability to electric shocks in rabbit hearts. The ventricles were paced apically, and uniform-field, truncated-exponential, monophasic shocks of reversed polarity were applied over a range of coupling intervals (CIs) in experiment and model. Experiments and simulations revealed that reversing the direction of externally-applied field (RV- or LV- shocks) alters the shape of the vulnerability area (VA), the 2-D grid encompassing episodes of arrhythmia induction. For RV- shocks, VA was nearly rectangular indicating little dependence of postshock arrhythmogenesis on CI. For LV- shocks, the probability of arrhythmia induction was higher for longer than for shorter CIs. The 3-D simulations demonstrated that these effects stem from the fact that reversal of field direction results in relocation of the main postshock excitable area from LV wall (RV- shocks) to septum (LV- shocks). Furthermore, the effect of septal (but not LV) excitable area in postshock propagation was found to strongly depend on preshock state. Knowledge regarding the location of the main postshock excitable area within the 3-D ventricular volume could be important for improving defibrillation efficacy.

Animals↗

Mechanisms of enhanced shock-induced arrhythmogenesis in the rabbit heart with healed myocardial infarction.

Shock-induced vulnerability and defibrillation have been mostly studied in structurally normal hearts. However, defibrillation therapy is normally applied to patients with diseased hearts, frequently those with prior myocardial infarction (MI). Shock-induced vulnerability and defibrillation have not been well studied under this condition. We sought to examine the mechanisms of shock-induced arrhythmogenesis and arrhythmia maintenance in a rabbit model of healed MI (4 wk or more postinfarction). Ligation of the lateral division or posterolateral division of the left coronary artery at a level of 40-70% from the apex was performed 53 +/- 21 days before acute experiments. Shock-induced vulnerability was assessed in infarcted (n = 8) and structurally normal (n = 8) hearts by delivering internal monophasic shocks at different shock strengths and delivery phases. Electrical activities from the anterior epicardium during shock application and during shock-induced arrhythmias were optically recorded and quantitatively analyzed. Ligation resulted in a transmural left ventricular free wall infarction mainly located at the apical region with a consistent endocardial border zone (BZ) as confirmed by histological studies. There were significant increases in the incidence, severity, and duration of shock-induced arrhythmias in the infarcted hearts versus controls due to 1) postshock break-excitation wavefronts that frequently originated near the infarction BZ and 2) the existence of an infarction BZ that created an anatomic reentry pathway and facilitated arrhythmia maintenance. In conclusion, the infarction BZ contributes to both increased shock-induced arrhythmogenesis and arrhythmia maintenance in the rabbit model of healed MI.

Animals↗

Mechanisms of superiority of ascending ramp waveforms: new insights into mechanisms of shock-induced vulnerability and defibrillation.

Monophasic ascending ramp (AR) and descending ramp (DR) waveforms are known to have significantly different defibrillation thresholds. We hypothesized that this difference arises due to differences in mechanisms of arrhythmia induction for the two waveforms. Rabbit hearts (n = 10) were Langendorff perfused, and AR and DR waveforms (7, 20, and 40 ms) were randomly delivered from two line electrodes placed 10 mm apart on the anterior ventricular epicardium. We optically mapped cellular responses to shocks of various strengths (5, 10, and 20 V/cm) and coupling intervals (CIs; 120, 180, and 300 ms). Optical mapping revealed that maximum virtual electrode polarization (VEP) was reached at significantly different times for AR and DR of the same duration (P < 0.05) for all tested CIs. As a result, VEP for AR were stronger than for DR at the end of the shock. Postshock break excitation resulting from AR generated faster propagation and typically could not form reentry. In contrast, partially dissipated VEP resulting from DR generated slower propagation; the wavefront was able to propagate into deexcited tissue and thus formed a shock-induced reentry circuit. Therefore, for the same delivered energy, AR was less proarrhythmic compared with DR. An active bidomain model was used to confirm the electrophysiological results. The VEP hypothesis explains differences in vulnerability associated with monophasic AR and DR waveforms and, by extension, the superior defibrillation efficacy of the AR waveform compared with the DR waveform.

Animals↗

Electroporation of the heart.

Defibrillation shocks are commonly used to terminate life-threatening arrhythmias. According to the excitation theory of defibrillation, such shocks are aimed at depolarizing the membranes of most cardiac cells resulting in resynchronization of electrical activity in the heart. If shock-induced changes in transmembrane potential are large enough, they can cause transient tissue damage due to electroporation. In this review evidence is presented that (a) electroporation of the heart tissue can occur during clinically relevant intensities of the external electrical field, and (b) electroporation can affect the outcome of defibrillation therapy; being both pro- and anti-arrhythmic.

Animals↗

The Gurvich waveform has lower defibrillation threshold than the rectilinear waveform and the truncated exponential waveform in the rabbit heart.

Implantable cardioverter defibrillator studies have established the superiority of biphasic waveforms over monophasic waveforms. However, external defibrillator studies of biphasic waveforms are not as widespread. Our objective was to compare the defibrillation efficacy of clinically used biphasic waveforms, i.e., truncated exponential, rectilinear, and quasi-sinusoidal (Gurvich) waveforms in a fibrillating heart model. Langendorff-perfused rabbit hearts (n = 10) were stained with a voltage-sensitive fluorescent dye, Di-4-ANEPPS. Transmembrane action potentials were optically mapped from the anterior epicardium. We found that the Gurvich waveform was significantly superior (p < 0.05) to the rectilinear and truncated exponential waveforms. The defibrillation thresholds (mean +/- SE) were as follows: Gurvich, 0.25 +/- 0.01 J; rectilinear-1, 0.34 +/- 0.01 J; rectilinear-2, 0.33 +/- 0.01 J; and truncated exponential, 0.32 +/- 0.02 J. Using optically recorded transmembrane responses, we determined the shock-response transfer function, which allowed us to predict the cellular response to waveforms at high accuracy. The passive parallel resistor-capacitor model (RC-model) predicted polarization superiority of the Gurvich waveform in the myocardium with a membrane time constant (taum) of less than 2 ms. The finding of a lower defibrillation threshold with the Gurvich waveform in an in vitro model of external defibrillation suggests that the Gurvich waveform may be important for future external defibrillator designs.

Action Potentials↗

Optical imaging of the heart.

Optical techniques have revolutionized the investigation of cardiac cellular physiology and advanced our understanding of basic mechanisms of electrical activity, calcium homeostasis, and metabolism. Although optical methods are widely accepted and have been at the forefront of scientific discoveries, they have been primarily applied at cellular and subcellular levels and considerably less to whole heart organ physiology. Numerous technical difficulties had to be overcome to dynamically map physiological processes in intact hearts by optical methods. Problems of contraction artifacts, cellular heterogeneities, spatial and temporal resolution, limitations of surface images, depth-of-field, and need for large fields of view (ranging from 2x2 mm2 to 3x3 cm2) have all led to the development of new devices and optical probes to monitor physiological parameters in intact hearts. This review aims to provide a critical overview of current approaches, their contributions to the field of cardiac electrophysiology, and future directions of various optical imaging modalities as applied to cardiac physiology at organ and tissue levels.

Action Potentials↗

Virtual electrode theory explains pacing threshold increase caused by cardiac tissue damage.

The virtual electrode polarization (VEP) effect is believed to play a key role in electrical stimulation of heart muscle. However, under certain conditions, including clinically, its existence and importance remain unknown. We investigated the influence of acute tissue damage produced by continuous pacing with strong current (40-mA, 4-ms biphasic pulses with 4-Hz frequency for 5 min) on stimulus-generated VEPs and pacing thresholds. A fluorescent optical mapping technique was used to obtain stimulus-induced transmembrane potential distribution around a pacing electrode applied to the ventricular surface of a Langendorff-perfused rabbit heart (n = 5). Maps and pacing thresholds were recorded before and after tissue damage. Spatial extents of electroporation and cell uncoupling were assessed by propidium iodide (n = 2) and connexin43 (n = 3) antibody staining, respectively. On the basis of these data, passive and active three-dimensional bidomain models were built to determine VEP patterns and thresholds for different-sized areas of the damaged region. Electrophysiological results showed that acute tissue damage led to disappearance of the VEP with an associated significant increase in pacing thresholds. Damage was expressed in electroporation and cell uncoupling within an approximately 1.0-mm-diameter area around the tip of the electrode. According to computer simulations, cell uncoupling, rather than electroporation, might be the direct cause of VEP elimination and threshold increase, which was nonlinearly dependent on the size of the damaged region. Fiber rotation with depth did not substantially affect the numerical results. The study explains failure to stimulate damaged tissue within the concepts of the VEP theory.

Acute Disease↗

Functional imaging of the embryonic pacemaking and cardiac conduction system over the past 150 years: technologies to overcome the challenges.

Early analyses of cardiac pacemaking and conduction system (CPCS) development relied on classic histology and visual inspection of the beating heart. Current techniques that facilitate delineation of the CPCS include the use of specific antibody markers and transgenic mouse lines specifically expressing reporter genes. Assaying the function of tiny embryonic hearts required an increase in the level of spatial and temporal resolution. Current methods for such analyses include the use of intracellular and extracellular microelectrodes, echocardiography, rapid optical imaging using fluorescent dyes, and most recently optical coherence tomography. This review will focus on methods developed to investigate the functional emergence of the embryonic cardiac conduction system. Where appropriate, the methods used to delineate the anatomic pathways will also be discussed. The combination of techniques to capture both morphological and functional data from the CPCS will further improve with continued interdisciplinary collaboration. The Supplementary Material referred to in this article can be found at the Anatomical Record website (http://www.interscience.wiley.com/jpages/0003-276X/suppmat).

Action Potentials↗

Structure-function relationship in the AV junction.

In the normal heart, the atrioventricular node (AVN) is part of the sole pathway between the atria and ventricles. Under normal physiological conditions, the AVN controls appropriate frequency-dependent delay of contractions. The AVN also plays an important role in pathology: it protects ventricles during atrial tachyarrhythmia, and during sinoatrial node failure an AV junctional pacemaker can drive the heart. Finally, the AV junction provides an anatomical substrate for reentry. Using fluorescent imaging with voltage-sensitive dyes and immunohistochemistry, we have investigated the structure-function relationship of the AV junction during normal conduction, reentry, and junctional rhythm. We identified molecular and structural heterogeneity that provides a substrate for the dual-pathway AVN conduction. We observed heterogeneity of expression of three isoforms of connexins: Cx43, Cx45, and Cx40. We identified the site of origin of junctional rhythm at the posterior extension of the AV node in 79% (n = 14) of the studied hearts. This structure was similar to the compact AV node as determined by morphologic and molecular investigations. In particular, both the posterior extension and the compact node express the pacemaking channel HCN4 (responsible for the I(F) current) and neurofilament 160. In the rabbit heart, AV junction conduction, reentrant arrhythmia, and spontaneous rhythm are governed by heterogeneity of expression of several isoforms of gap junctions and ion channels. Uniform neurofilament expression suggests that AV nodal posterior extensions are an integral part of the cardiac pacemaking and conduction system. On the other hand, differential expression of Cx isoforms in this region provides an explanation of longitudinal dissociation, dual-pathway electrophysiology, and AV nodal reentrant arrhythmogenesis.

Animals↗

Dynamics of virtual electrode-induced scroll-wave reentry in a 3D bidomain model.

Functional reentry in the heart can be caused by a wave front of excitation rotating around its edge. Previous simulations on the basis of monodomain cable equations predicted the existence of self-sustained, vortex-like wave fronts (scroll waves) rotating around a filament in three dimensions. In our simulations, we used the more accurate bidomain model with modified Beeler-Reuter ionic kinetics to study the dynamics of scroll-wave filaments in a 16 x 8 x 1.5-mm slab of ventricular tissue with straight fibers. Wave fronts were identified as the areas with inward current. Their edges represented the filaments. Both transmural and intramural reentries with I- and U-shaped filaments, respectively, were obtained by the S1-S2 point stimulation protocol through the virtual electrode-induced phase singularity mechanism. The filaments meandered along elongated trajectories and tended to attach to the tissue boundaries exposed to air (no current flow) rather than to the bath (zero extracellular potential). They completely detached from electroporated (zero transmembrane potential) boundaries. In our simulations, the presence of the bath led to generation of only U-shaped filaments, which survived for the 1.5-mm-thick slab but not for the slabs of 0.5- or 3-mm thicknesses. Thus boundary conditions may be another determinant of the type and dynamics of reentry.

Action Potentials↗

Site of origin and molecular substrate of atrioventricular junctional rhythm in the rabbit heart.

During failure of the sinoatrial node, the heart can be driven by an atrioventricular (AV) junctional pacemaker. The position of the leading pacemaker site during AV junctional rhythm is debated. In this study, we present evidence from high-resolution fluorescent imaging of electrical activity in rabbit isolated atrioventricular node (AVN) preparations that, in the majority of cases (11 out of 14), the AV junctional rhythm originates in the region extending from the AVN toward the coronary sinus along the tricuspid valve (posterior nodal extension, PNE). Histological and immunohistochemical investigation showed that the PNE has the same morphology and unique pattern of expression of neurofilament160 (NF160) and connexins (Cx40, Cx43, and Cx45) as the AVN itself. Block of the pacemaker current, If, by 2 mmol/L Cs+ increased the AV junctional rhythm cycle length from 611+/-84 to 949+/-120 ms (mean+/-SD, n=6, P<0.001). Immunohistochemical investigation showed that the principal If channel protein, HCN4, is abundant in the PNE. As well as the AV junctional rhythm, the PNE described in this study may also be involved in the slow pathway of conduction into the AVN as well as AVN reentry, and the predominant lack of expression of Cx43 as well as the presence of Cx45 in the PNE shown could help explain its slow conduction.

Animals↗

Shock-induced arrhythmogenesis is enhanced by 2,3-butanedione monoxime compared with cytochalasin D.

Investigation of the mechanisms of arrhythmia genesis and maintenance has benefited from the use of optical mapping techniques that employ excitation-contraction uncouplers. We investigated the effects of the excitation-contraction uncouplers 2,3-butanedione monoxime (BDM) and cytochalasin D (Cyto D) on the induction and maintenance of arrhythmia by electric shocks. Electrical activity was optically mapped from anterior epicardium of rabbit hearts (n = 9) during shocks (-100 V, 8 ms) applied from a ventricular lead at various phases of action potential duration (APD). Restitution curves were obtained using S1-S2 protocol and measurement of APD values at 70% of repolarization. Compared with Cyto D, BDM significantly shortened APD at 90% of repolarization, although no significant difference in dispersion of repolarization was observed. Wavelength was also shortened with BDM. In general, shock-induced arrhythmias with BDM and Cyto D were ventricular tachycardic in nature. With respect to shock-induced sustained arrhythmias, the vulnerable window was wider and the incidence was higher with BDM than with Cyto D. There was also a difference in the morphology of ventricular tachycardia (VT) between the two agents. The arrhythmias with BDM usually resembled monomorphic VT, especially those that lasted >30 s. In contrast, arrhythmias with Cyto D more resembled polymorphic VT. However, the average number of phase singularities increased under Cyto D vs. BDM, whereas no significant difference in the dominant frequency of shock-induced sustained arrhythmia was observed. BDM reduced the slope of the restitution curve compared with Cyto D, but duration of arrhythmia under BDM was significantly increased compared with Cyto D. In conclusion, BDM increased arrhythmia genesis and maintenance relative to Cyto D.

Action Potentials↗

Cx43 and dual-pathway electrophysiology of the atrioventricular node and atrioventricular nodal reentry.

Fluorescent imaging has revealed that posterior nodal extensions provide the anatomical substrate for the dual-pathway electrophysiology of the atrioventricular (AV) node during normal conduction and reentry. The reentry can be intranodal, or as well as the posterior nodal extensions, it can involve an endocardial layer of atrial/atrial-nodal (A/AN) cells as part of the AV nodal reentry (AVNR) circuit. Using fluorescent imaging with a voltage-sensitive dye and immunolabeling of Cx43, we mapped the electrical activity and structural substrate in 3 types of AVNR induced by premature atrial stimulation in 8 rabbit hearts. In 6 cases, the AVNR pathway involved (1) a fast pathway (FP), (2) the A/AN layer, and (3) a slow pathway (SP). In 4 cases, reentry took the path (1) SP, (2) A/AN layer, and (3) FP. In 2 cases, reentry was intranodal, propagating between the 2 posterior nodal extensions. Immunolabeling revealed that the FP and SP are formed by Cx43-expressing bundles surrounded by tissue without Cx43. Cx43-expressing posterior nodal extensions are the substrate of AVNR during both intranodal and extranodal reentry.

Animals↗

Optical mapping technique applied to biventricular pacing: potential mechanisms of ventricular arrhythmias occurrence.

Although it has been suggested that multisite ventricular pacing alleviates heart failure by restoring ventricular electrical synchronization, the respective roles of voltage output, interventricular delay, and pacing sites in the development of ventricular arrhythmias occurrence have not been studied during biventricular pacing or LV pacing. Voltage-sensitive dye was used in eight ischemic Langerdorff-perfused guinea pig hearts to measure ventricular activation times and examine conduction patterns during multisite pacing from three RV and four LV sites. The hearts were stained with di-4-ANEPPS and mapped with a 16 x 16 photodiode array at a resolution of 625 microns per diode. Isochronal maps of RV and LV activation were plotted. Ischemia was produced by gradually halving the perfusion output over 5 minutes. Pacing the RV apex and the base of the LV anterior wall was associated with the most homogeneous and rapid activation pattern (28 +/- 9 vs 41 +/- 12 ms with the other configurations, P < 0.01), and no inducible arrhythmia. In six hearts, ventricular tachycardia could be induced when pacing from the right and left free walls with 20 ms of interventricular delay, at six times the pacing threshold output. In four hearts, simultaneous RV and LV pacing at high voltage output induced ventricular fibrillation with complex three-dimensional propagation patterns, independently of the pacing sites. During biventricular pacing with ischemia, pacing at high voltage output with a long interventricular delay is likely to induce ventricular arrhythmias, particularly when left and right pacing results in a conduction pattern orthogonal to the ventricular myocardial fibers orientation.

Animals↗