Search PubMed⌕ Search

Biomedical subjects

I Vodyanoy

Publications and source records attributed to I Vodyanoy.

At least 19 recordsLinked to original sources

Genes encoding bile acid, phospholipid and anion transporters are expressed in a human fetal cardiomyocyte culture.

OBJECTIVES: To establish a human fetal cardiomyocyte culture and to investigate whether the genes that encode transporters that may influence influx or efflux of bile acids are expressed in human fetal cardiomyocytes. DESIGN: Laboratory study. SETTING: Imperial College London. SAMPLE: Six fetal hearts were obtained at the time of termination of pregnancy at 12-13 weeks of gestation and used to generate primary human cardiomyocyte cultures. METHODS: To confirm the presence of cardiomyocytes, the cells were incubated with monoclonal antibodies to sarcomeric alpha-actinin and anticardiac myosin heavy chain. Real-time reverse transcription polymerase chain reaction was used to establish whether transcripts of genes that may influence bile acid transport are present in the culture (NTCP, BSEP, MDR3, FIC1, MRP2, MRP3, OATP-A, OATP-C, OATP-D, OATP-E) and whether taurocholate administration alters messenger RNA (mRNA) expression. MAIN OUTCOME MEASURES: Relative mRNA expression of genes of interest. RESULTS: Real-time polymerase chain reaction demonstrated the presence of mRNA for BSEP, MDR3, FIC1, OATP-C, OATP-D and OATP-E in fetal heart. Four transcripts remained in the cardiomyocyte culture (BSEP, MDR3, FIC1 and OATP-D), and we demonstrated the influence of taurocholate on gene expression. CONCLUSIONS: We have developed an in vitro model of the fetal heart that may be used for studies of the cardiac effect of endobiotics, e.g. bile acids, or of specific agents that may be used to treat the mother or fetus in pregnancy.

Bile Acids and Salts↗

Cell volume measurement using scanning ion conductance microscopy.

We report a novel scanning ion conductance microscopy (SICM) technique for assessing the volume of living cells, which allows quantitative, high-resolution characterization of dynamic changes in cell volume while retaining the cell functionality. The technique can measure a wide range of volumes from 10(-19) to 10(-9) liter. The cell volume, as well as the volume of small cellular structures such as lamelopodia, dendrites, processes, or microvilli, can be measured with the 2.5 x 10(-20) liter resolution. The sample does not require any preliminary preparation before cell volume measurement. Both cell volume and surface characteristics can be simultaneously and continuously assessed during relatively long experiments. The SICM method can also be used for rapid estimation of the changes in cell volume. These are important when monitoring the cell responses to different physiological stimuli.

Animals↗

Functional localization of single active ion channels on the surface of a living cell.

The spatial distribution of ion channels in the cell plasma membrane has an important role in governing regional specialization, providing a precise and localized control over cell function. We report here a novel technique based on scanning ion conductance microscopy that allows, for the first time, mapping of single active ion channels in intact cell plasma membranes. We have mapped the distribution of ATP-regulated K+ channels (KATP channels) in cardiac myocytes. The channels are organized in small groups and anchored in the Z-grooves of the sarcolemma. The distinct pattern of distribution of these channels may have important functional implications.

Adenosine Triphosphate↗

Membrane surface-charge titration probed by gramicidin A channel conductance.

We manipulate lipid bilayer surface charge and gauge its influence on gramicidin A channel conductance by two strategies: titration of the lipid charge through bulk solution pH and dilution of a charged lipid by neutral. Using diphytanoyl phosphatidylserine (PS) bilayers with CsCl aqueous solutions, we show that the effects of lipid charge titration on channel conductance are masked 1) by conductance saturation with Cs+ ions in the neutral pH range and 2) by increased proton concentration when the bathing solution pH is less than 3. A smeared charge model permits us to separate different contributions to the channel conductance and to introduce a new method for "bilayer pKa" determination. We use the Gouy-Chapman expression for the charged surface potential to obtain equilibria of protons and cations with lipid charges. To calculate cation concentration at the channel mouth, we compare different models for the ion distribution, exact and linearized forms of the planar Poisson-Boltzmann equation, as well as the construction of a "Gibbs dividing surface" between salt bath and charged membrane. All approximations yield the intrinsic pKain of PS lipid in 0.1 M CsCl to be in the range 2.5-3.0. By diluting PS surface charge at a fixed pH with admixed neutral diphytanoyl phosphatidylcholine (PC), we obtain a conductance decrease in magnitude greater than expected from the electrostatic model. This observation is in accord with the different conductance saturation values for PS and PC lipids reported earlier (, Biochim. Biophys. Acta. 552:369-378) and verified in the present work for solvent-free membranes. In addition to electrostatic effects of surface charge, gramicidin A channel conductance is also influenced by lipid-dependent structural factors.

Gramicidin↗

Lipid packing stress and polypeptide aggregation: alamethicin channel probed by proton titration of lipid charge.

Lipid membranes are not passive, neutral scaffolds to hold membrane proteins. In order to examine the influence of lipid packing energetics on ion channel expression, we study the relative probabilities of alamethicin channel formation in dioleoylphosphatidylserine (DOPS) bilayers as a function of pH. The rationale for this strategy is our earlier finding that the higher-conductance states, corresponding to larger polypeptide aggregates, are more likely to occur in the presence of lipids prone to hexagonal HII-phase formation (specifically DOPE), than in the presence of lamellar L alpha-forming lipids (DOPC). In low ionic strength NaCl solutions at neutral pH, the open channel in DOPS membranes spends most of its time in states of lower conductance and resembles alamethicin channels in DOPC; at lower pH, where the lipid polar groups are neutralized, the channel probability distribution resembles that in DOPE. X-Ray diffraction studies on DOPS show a progressive decrease in the intrinsic curvature of the constituent monolayers as well as a decreased probability of HII-phase formation when the charged lipid fraction is increased. We explore how proton titration of DOPS affects lipid packing energetics, and how these energetics couple titration to channel formation.

Diglycerides↗

Stochastic resonance in non-dynamical systems without response thresholds.

The addition of noise to a system can sometimes improve its ability to transfer information reliably. This phenomenon--known as stochastic resonance--was originally proposed to account for periodicity in the Earth's ice ages, but has now been shown to occur in many systems in physics and biology. Recent experimental and theoretical work has shown that the simplest system exhibiting 'stochastic resonance' consists of nothing more than signal and noise with a threshold-triggered device (when the signal plus noise exceeds the threshold, the system responds momentarily, then relaxes to equilibrium to await the next triggering event). Here we introduce a class of non-dynamical and threshold-free systems that also exhibit stochastic resonance. We present and analyse a general mathematical model for such systems, in which a sequence of pulses is generated randomly with a probability (per unit time) that depends exponentially on an input. When this input is a sine-wave masked by additive noise, we observe an increase in the output signal-to-noise ratio as the level of noise increases. This result shows that stochastic resonance can occur in a broad class of thermally driven physico-chemical systems, such as semiconductor p-n junctions, mesoscopic electronic devices and voltage-dependent ion channels, in which reaction rates are controlled by activation barriers.

Models, Theoretical↗

Scanning ion conductance microscopy of living cells.

Currently there is a great interest in using scanning probe microscopy to study living cells. However, in most cases the contact the probe makes with the soft surface of the cell deforms or damages it. Here we report a scanning ion conductance microscope specially developed for imaging living cells. A key feature of the instrument is its scanning algorithm, which maintains the working distance between the probe and the sample such that they do not make direct physical contact with each other. Numerical simulation of the probe/sample interaction, which closely matches the experimental observations, provides the optimum working distance. The microscope scans highly convoluted surface structures without damaging them and reveals the true topography of cell surfaces. The images resemble those produced by scanning electron microscopy, with the significant difference that the cells remain viable and active. The instrument can monitor small-scale dynamics of cell surfaces as well as whole-cell movement.

Animals↗

Signal transduction across alamethicin ion channels in the presence of noise.

We have studied voltage-dependent ion channels of alamethicin reconstituted into an artificial planar lipid bilayer membrane from the point of view of electric signal transduction. Signal transduction properties of these channels are highly sensitive to the external electric noise. Specifically, addition of bandwidth-restricted "white" noise of 10-20 mV (r.m.s.) to a small sine wave input signal increases the output signal by approximately 20-40 dB conserving, and even slightly increasing, the signal-to-noise ratio at the system output. We have developed a small-signal adiabatic theory of stochastic resonance for a threshold-free system of voltage-dependent ion channels. This theory describes our main experimental findings giving good qualitative understanding of the underlying mechanism. It predicts the right value of the output signal-to-noise ratio and provides a reliable estimate for the noise intensity corresponding to its maximum. Our results suggest that the alamethicin channel in a lipid bilayer is a good model system for studies of mechanisms of primary electrical signal processing in biology showing an important feature of signal transduction improvement by a fluctuating environment.

Alamethicin↗

Specialized scanning ion-conductance microscope for imaging of living cells.

A specialized scanning ion conductance microscope (SICM) for imaging living cells has been developed from a conventional patch-clamp apparatus, which uses a glass micropipette as the sensitive probe. In contrast with other types of scanning probe microscope, the SICM probe has significant advantages for imaging living cells: it is most suitable for imaging samples immersed in water solutions; and since the probe senses ion current and does not need physical contact with the sample during the scan, any preliminary preparation of cells (fixation or adherence to a substrate) is unnecessary. We have successfully imaged murine melanocytes in growth medium. The microscope images the highly convoluted surface structures without damaging or deforming them, and reveals the true, three-dimensional relief of the cells. This instrument has considerable ability to operate, potentially simultaneously, in applications as diverse as real-time microscopy, electrophysiology, micromanipulation and drug delivery.

Animals↗

Noise-induced enhancement of signal transduction across voltage-dependent ion channels.

The presence of noise in a signal transduction system usually interferes with its ability to transfer information reliably. But many nonlinear systems can use noise to enhance performance, and this phenomenon, called stochastic resonance, may underlie the extraordinary ability of some biological systems to detect and amplify small signals in noisy environments. Previous work has demonstrated the occurrence of stochastic resonance in a complex system of biological transducers and neural signal pathways, but the possibility that it could occur at the sub-cellular level has remained open. Here we report the observation of stochastic resonance in a system of voltage-dependent ion channels formed by the peptide alamethicin. A hundred-fold increase in signal transduction induced by external noise is accompanied by a growth in the output signal-to-noise ratio. The system of ion channels considered here represents the simplest biological system yet known to exhibit stochastic resonance.

Alamethicin↗

Watching small molecules move: interrogating ionic channels using neutral solutes.

Whether they are small enough to wriggle through the current-carrying part of an ionic channel or big enough to be kept outside and thus able to exert an osmotic stress on the channel space, polymers interact with channels in several instructive ways. The osmotic stress of excluded polymers allows one to measure the number of water molecules that come out of the channel in transitions between various "open" to "closed" states. The loss of osmotic activity, due to the partial or completely unrestricted admission of small polymers becomes a measure of the transfer probabilities of polymers from solution to small cavities; it provides an opportunity to study polymer conformation in a perfectly sieved preparation. Current fluctuations due to the partial blockage by a transient polymer are converted into estimates of times of passage and diffusion constants of polymers in channels. These estimates show how a channel whose functional states last for milliseconds is able to average over the interactions with polymers, interactions that last only microseconds. One sees clearly that in this averaging, the macromolecular channel is large enough to react like a macroscopic object to the chemical potentials of the species that modulate its activity.

Electric Conductivity↗

Counting polymers moving through a single ion channel.

The change in conductance of a small electrolyte-filled capillary owing to the passage of sub-micrometre-sized particles has long been used for particle counting and sizing. A commercial device for such measurements, the Coulter counter, is able to detect particles of sizes down to several tenths of a micrometre. Nuclepore technology (in which pores are etched particle tracks) has extended the lower limit of size detection to 60-nm particles by using a capillary of diameter 0.45 micron (ref. 4). Here we show that natural channel-forming peptides incorporated into a bilayer lipid membrane can be used to detect the passage of single molecules with gyration radii as small as 5-15 A. From our experiments with alamethicin pores we infer both the average number and the diffusion coefficients of poly(ethylene glycol) molecules in the pore. Our approach provides a means of observing the statistics and mechanics of flexible polymers moving within the confines of precisely defined single-molecule structures.

Alamethicin↗

Enhancement of gustatory nerve fibers to NaCl and formation of ion channels by commercial novobiocin.

Single fibers of the rat chorda tympani nerve were used to study the mechanism of action of the antibiotic novobiocin on salt taste transduction. In the rat, novobiocin selectively enhanced the responses of sodium-specific and amiloride-sensitive chorda tympani nerve fibers (N type) without affecting more broadly responsive cation-sensitive and amiloride-insensitive fibers (E type). In the presence of amiloride, novobiocin was ineffective at enhancing the response of N-type fibers toward sodium chloride. Novobiocin also increased the conductance of bilayers formed from neutral lipids by forming nonrectifying ion channels with low conductance (approximately 7 pS in 110 mM NaCl), long open times (several seconds and longer), and high cation selectivity. Amiloride did not alter either the conductance or kinetics of these novobiocin channels. These observations suggest that even though novobiocin is able to form cation channels in lipid bilayers, and possibly in cell membranes as well, its action on the salt-taste response is through modulation of existing amiloride-sensitive sodium channels.

Amiloride↗

Probability of alamethicin conductance states varies with nonlamellar tendency of bilayer phospholipids.

With few exceptions, membrane lipids are usually regarded as a kind of filler or passive solvent for membrane proteins. Yet, cells exquisitely control membrane composition. Many phospholipids found in plasma membrane bilayers favor packing into inverted hexagonal bulk phases. It was suggested that the strain of forcing such lipids into a bilayer may affect membrane protein function, such as the operation of transmembrane channels. To investigate this, we have inserted the peptide alamethicin into bilayer membranes composed of lipids of empirically determined inverted hexagonal phase "spontaneous radii" Ro, which will have expectably different degrees of strain when forced into bilayer form. We observe a correlation between measured Ro and the relative probabilities of different conductance states. States of higher conductance are more probable in dioleoylphosphatidylethanolamine, the lipid of highest curvature, 1/Ro, than in dioleoylphosphatidylcholine, the lipid of lowest curvature.

Alamethicin↗

Probing alamethicin channels with water-soluble polymers. Size-modulated osmotic action.

Contrary to expectations based on heightened solution viscosity, alamethicin channels appear to speed up in the presence of water soluble polyethylene glycols (PEGs) and dextrans. Specifically, added polymers reduce the probabilities of transition to higher-conductance states but do not change channel lifetimes. They thereby shorten the duration of current "bursts." These modified probabilities and kinetics reveal the action of polymer osmotic stress to suppress channel formation. The osmotic action of large, fully excluded polymers shows that some 3,000 A3 of water are taken up by the channel from the solution upon each transition to an adjacent higher-conductance state. The partial osmotic action of incompletely excluded polymers reveals the extent of exclusion for different-size polymers. The partial exclusion thus measured agrees remarkably well with estimates using data on reduction of single-channel conductance by current-impeding polymers. One can relate the degree of each polymer's exclusion to its size and to the radius of the channel pore.

Alamethicin↗

Probing alamethicin channels with water-soluble polymers. Effect on conductance of channel states.

Channel access resistance has been measured to estimate the characteristic size of a single ion channel. We compare channel conductance in the presence of nonpenetrating water-soluble polymers with that obtained for polymer-free electrolyte solution. The contribution of the access resistance to the total alamethicin channel resistance is approximately 10% for first three open channel levels. The open alamethicin channel radii inferred for these first three levels from the access resistance are 6.3, 10.3, and 11.4 A. The dependence of channel conductance on polymer molecular weight also allows evaluation of the channel dimensions from polymer exclusion. Despite varying conductance, it was shown that steric radii of the alamethicin channel at different conductance levels remain approximately unchanged. These results support a model of the alamethicin channel as an array of closely packed parallel pores of nearly uniform diameter.

Alamethicin↗

Alamethicin adsorption to a planar lipid bilayer.

The effect of alamethicin and its derivatives on the voltage-dependent capacitance of phosphatidylethanolamine (squalane) membranes was measured using two different methods: lock-in detection and voltage pulse. Alamethicin and its derivatives modulate the voltage-dependent capacitance at voltages lower than the voltage at which alamethicin-induced conductance is detected. The magnitude and sign of this alamethicin-induced capacitance change depends on the aqueous alamethicin concentration and the kind of alamethicin used. Our experimental data can be interpreted as a potential-dependent pseudocapacitance associated with adsorbed alamethicin. Pseudocapacitance is expressed as a function of alamethicin charge, its concentration in the bathing solution and the applied electric field. The theory describes the dependence of the capacitance on applied voltage and alamethicin concentration. When alamethicin is neutral the theory predicts no change of the voltage-dependent capacitance with either sign of applied voltage. Experimental data are consistent with the model in which alamethicin molecules interact with each other while being adsorbed to the membrane surface. The energy of this interaction depends on the alamethicin concentration.

Alamethicin↗