Low energy partial ablation of the atrioventricular node junction in the dog using a suction-ablation catheter.

A suction electrode catheter was used for low energy, partial ablation of the atrioventricular (AV) node junction in 12 dogs. In 10 dogs, partial injury of the AV node was induced. In six dogs, delivered energy was measured precisely with use of a specially designed electronic circuit. The total energy required for partial ablation was 225 +/- 91 J. The increase in PR (p less than 0.0001) and AH (p less than 0.001) intervals was proportional to the energy delivered. After ablation, the PR interval increased from 98 +/- 10 to 154 +/- 33 ms (p less than 0.004) and the AH interval from 59 +/- 8 to 102 +/- 16 ms (p less than 0.004). There was no significant change in QRS, QTc, HV or RR intervals. AH and PR intervals were significantly prolonged at 3, 7 and 14 days after ablation (p less than 0.05). Anterograde conduction was significantly altered in 10 dogs. Anterograde AV node effective refractory period increased from 157 +/- 14 to 214 +/- 45 ms (p less than 0.005). Anterograde AV node Wenckebach cycle length increased from 196 +/- 30 to 244 +/- 44 ms (p less than 0.002). Retrograde conduction was assessed in three dogs. Retrograde AV node effective refractory period increased from 156 +/- 21 to 260 ms in two dogs, with complete retrograde block in the third. These changes persisted for up to 2 weeks. Pathologic changes were limited to the region of the AV node. In four dogs adherent thrombus without pulmonary emboli was noted. Partial focal injury to the AV node is feasible in the canine model.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Nonpharmacological therapy of supraventricular arrhythmias: surgery and catheter ablation techniques.

Treatment of supraventricular tachyarrhythmias has undergone substantial change and development over the past decade. Pharmacological approaches to management of supraventricular arrhythmias have been supplanted by nonpharmacological techniques. These nonpharmacological techniques are the subject of the present review. The first part of this review will concentrate on the nonpharmacological techniques available for the treatment of supraventricular tachycardia, excluding Wolff-Parkinson-White syndrome, whereas Part 2 will concentrate on the surgical and the ablative procedures for management of tachycardias associated with Wolff-Parkinson-White syndrome. Pacing techniques for termination of supraventricular tachycardias are beyond the scope of this article and will not be included in the discussion.

Animals

Treatment of malignant ventricular arrhythmias with the automatic implantable cardioverter defibrillator.

Twenty-eight patients with malignant ventricular arrhythmias were treated with the automatic implantable cardioverter-defibrillator (AICD) in a 14-month period. Thirteen patients were resuscitated from a ventricular fibrillation (VF) episode. Fifteen patients presented with ventricular tachycardia (VT) refractory to medical therapy. The etiology was coronary artery disease in 23 of 28 patients (82%), dilated cardiomyopathy in 2 of 28 patients (7%), sarcoidosis in 2 of 28 patients, and 1 patient in 28 had lupus erythmatosis. The mean left ventricular ejection fraction was 29%. A total of 27 of 28 patients (96%) patients had inducible ventricular tachycardia using programmed stimulation. The patients considered for AICD implant failed a mean of 3.6 antiarrhythmic drugs. Rate counting and defibrillating leads were inserted through a lateral thoracotomy in 17 patients and a mediansternotomy incision in 11 patients in conjunction with another cardiac procedure in 10 patients. The generators were positioned in a subcutaneous pocket beneath the left costal margin. There were no operative deaths. The mean follow-up was 6.7 months (range 1 to 14) with no VT/VF deaths in patients with defibrillators. The study demonstrated that AICD is an effective device for prevention of sudden cardiac death.

Adult

Initial clinical experience with a rate responsive pacemaker.

Prism-CLR is a new single chamber unipolar pace, bipolar or unipolar sense, rate responsive pacemaker that utilizes a closed-loop system based on the analysis of the evoked potential for rate adjustment. It also has an automatic output regulation feature for capture verification and threshold search. Five patients in whom this pacemaker was implanted exhibited an appropriate rate increase with exercise and psychological stress. Automatic output regulation functioned appropriately in three of five patients. Preliminary data suggest that Prism-ClR is an effective pacemaker for patients who may benefit from rate responsive pacing. The automatic output regulation recognition algorithm may need modification in some patients.

Aged

Alternating sequence of retrograde atrial activation in patients with dual AV nodal physiology.

Patients with dual AV nodal physiology have been demonstrated to have earliest retrograde activation sequence of the fast pathway in the lower septal right atrium and slow pathway in the proximal coronary sinus, and the posterior atrial septum. This case report describes a patient with dual AV nodal physiology demonstrating a dual sequence of retrograde activation with 2:1 block occurring in the fast pathway causing the conduction to proceed alternately via fast then slow pathway. This sequence was abolished by atropine allowing conduction to proceed via fast pathway. Surgical cure of patients with reentrant AV nodal tachycardia suggests the presence of two anatomically distinct AV nodal-like pathways. This case report confirms this observation and further suggests preferential autonomic modulation of the fast pathway.

Adult

Systolic expansion of the aortic root: an echocardiographic and angiographic sign of aortic composite graft dehiscence.

Precise diagnosis of aortic composite graft dehiscence may be difficult. We present a case illustrating this problem and its resolution. Two-dimensional echocardiography and contrast ventriculography revealed a space adjacent to the aortic valve conduit that demonstrated marked systolic expansion. The dynamic variation of this space was secondary to communication with the left ventricular cavity caused by disruption of the composite graft valve ring. Thus, systolic expansion of the aortic root is a useful echocardiographic and angiographic sign of composite graft dehiscence.

Adult

Implanted automatic defibrillators: effects of drugs and pacemakers.

The automatic implantable cardioverter defibrillator is an effective device for prevention of sudden cardiac death. Patients who require the implantation of the device often require permanent pacing for symptomatic bradyarrhythmias and may require antiarrhythmic drug therapy. Antiarrhythmic drugs may alter the defibrillation thresholds, arrhythmia cycle length and frequency, pacing thresholds and postshock excitability. Interactions between the defibrillator and the pacemaker may result in sensing problems, leading to multiple counting and inappropriate shocks, or ventricular fibrillation nondetection, sensing or capture failure post defibrillation and pacemaker reprogramming induced by defibrillator discharge. The potential for interactions will increase as the new generation of programmable defibrillators become clinically available, combining features of permanent pacemakers, antitachycardia pacemakers and defibrillators.

Anti-Arrhythmia Agents

The automatic implantable cardioverter defibrillator: T wave sensing in the newest generation.

The AICD uses an automatic gain control amplifier for detecting the small electrograms during ventricular fibrillation. The latest generation of the AICD appears to have a more sensitive lock on gain amplifier, as 6 of 76 patients implanted with the new AICD had double counting of the QRS-T wave complex resulting in asymptomatic discharges. Solutions to the problem of limiting these asymptomatic discharges are difficult and include slowing of the heart rate with beta blockers, changing the lead system, or replacement of the device. One of the six patients was treated with beta blockers. Three patients had their device changed, two patients requested the inactivation of their device until a rate programmable unit was available. The potential for T wave sensing in a lock on gain amplifier represents the unique dilemma between detecting small electrograms of ventricular fibrillation, and detecting diastolic events which occur shortly after the QRS complex.

Adult

Infectious hepatitis in dialysis patients.

Infectious hepatitis is a major problem for patients with end-stage renal disease and for staff caring for these patients. Initially hepatitis B was the major cause of hepatitis in dialysis patients and staff. Patients had a tendency to develop chronic hepatitis or become chronic carriers of the virus while staff either developed typical acute hepatitis or a primary antibody response. The discovery of the hepatitis B surface antigen (HBsAg), the screening of transfused blood for HBsAg, and the institution of infection control measures including isolation techniques have resulted in a remarkable decrease in the incidence of this disease. Nonetheless, the problem of infectious hepatitis continues as non-A, non-B hepatitis has become more commonplace among dialysis patients. Unfortunately, no viral markers have been discovered, and blood products remain the major vehicle of transmission. The institution of infection control measures similar to those used to control hepatitis B has probably been effective in controlling the spread of this disease. It is hoped that the discovery of the etiologic agent(s), with the eventual goal of screening blood products and the development of a vaccine, will lead to full control of this disorder.

Dialysis

Pathologic findings related to the lead system and repeated defibrillations in patients with the automatic implantable cardioverter-defibrillator.

The purpose of the present study was to examine at autopsy the effect of multiple defibrillations on the myocardium and the pathologic consequences of short- and long-term placement of the intravascular and interpericardial leads of the automatic implantable cardioverter-defibrillator. Twenty-five patients were examined at autopsy; 8 of them underwent lead implantation only and 17 received both leads and the automatic implantable cardioverter-defibrillator. Twelve patients (48%) died of ventricular tachycardia or ventricular fibrillation; seven (28%) died of other causes. Acute pericarditis occurred in all patients, resulting in a localized, progressive fibrosis around the apical patch lead without giving rise to pericardial restriction. Thrombus formation was associated with the superior vena cava spring electrode in four patients (17%) and the right ventricular rate-sensing electrode in one patient (4%). Asymptomatic pulmonary emboli occurred in two patients (8%). In one patient who underwent defibrillation 59 times, superior vena cava changes consisted of vein wall destruction, fibrosis and thrombus formation. Pathologic changes under the apical patch related to defibrillation were observed in seven patients; two of these had fewer than 5 defibrillations, one had 8 defibrillations and four had 21 to 74 defibrillations. These changes consisted of contraction band necrosis in four patients, vacuolar cytoplasmic clearing and loss of myocytes confined to the myocardium under the patch electrode in five patients who had multiple defibrillations. The observed pathologic changes were estimated to affect less than 2% of the total myocardial mass. Thus, the automatic implantable cardioverter-defibrillator lead system and multiple defibrillations result in localized myocardial injury confined to the tissue under the patch electrode.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Acute renal failure in sickle-cell disease.

Two patients with reversible acute oligoanuric renal failure in the setting of sickle-cell crisis are presented. The renal failure could not be attributed to volume depletion, urinary tract obstruction, or exogenous nephrotoxins. There were several features in each case that suggested the presence of nontraumatic rhabdomyolysis. The possible role of pigmenturia in the pathogenesis of the reversible renal failure in sickle-cell crisis is discussed.

Acute Kidney Injury

Profound hyperkalemia without electrocardiographic manifestations.

Although the electrocardiogram (ECG) is not considered a reliable indicator of mild to moderate hyperkalemia, profound elevations of serum potassium concentration generally produce classic ECG manifestations. We report two cases of severe hyperkalemia (greater than 9.0 mEq/L) in which the ECGs did not reveal the expected manifestations of hyperkalemia. Thus, even with profound serum potassium elevations, the ECG cannot reliably be used to exclude the presence of hyperkalemia or to monitor therapy designed to lower the serum potassium concentration.

Aged