150 records · Page 9Linked to original sources

Development of a tracking method for image analysis of time-lapse deformation of trabecular structure in a human bone.

A new method to track the deformation of the trabecular structure in a human bone, which determines the dynamic characteristics of bone, was developed using elastic matching. This is a kind of image analysis. By comparing two 3-D images of the same bone taken at different times, this method computes displacement of any points in the bone during the period. This method makes it possible to demonstrate the behavior of the trabecular structure to mechanical loads and to estimate changes in the strength of a bone.

Bone Diseases↗

Development of a membrane oxygenator for ECMO using a novel fine silicone hollow fiber.

One of the limitations of conventional silicone hollow fiber oxygenators compared with microporous membrane oxygenators is poor gas permeability. However, the silicone hollow fiber is free from plasma leakage, which is the major life limiting factor of the microporous membrane oxygenator. It has been difficult to fabricate a fine, thin hollow fiber for reduction of resistance to gas permeability because of the poor mechanical strength of conventional silicone materials. The authors developed a novel silicone material with sufficient mechanical strength, and a fine silicone hollow fiber with a diameter of 30 microns and wall thickness of 50 microns, which is approximately half that of a conventional silicone hollow fiber. Using this newly developed silicone hollow fiber, the authors developed a compact extracapillary flow membrane oxygenator. The oxygenator consists of fine silicone hollow fibers inserted in a housing made of polycarbonate. The housing is a cylindrical case, 20 cm long and 55 mm in inside diameter. The hollow fibers are cross-wound. The surface area of the membrane is 2.0 m2, and priming volume is 230 ml. Gas transfer performance of the newly developed oxygenator was evaluated by in vitro experiments. Oxygen and carbon dioxide transfer rates were 195 ml/min and 165 ml/min, at a blood flow rate 3 L/min. The novel silicone membrane oxygenator developed in this study can be used for extended duration in such applications as extracorporeal membrane oxygenation.

Biocompatible Materials↗

Relaxation in different-sized rat blood vessels mediated by endothelium-derived hyperpolarizing factor: importance of processes mediating precontractions.

To clarify the mechanisms involved in relaxations mediated by endothelium-derived hyperpolarizing factor (EDHF), acetylcholine (ACh)-induced endothelium-dependent relaxations and hyperpolarizations were examined in the rat aorta, the main branch of the mesenteric artery (MBMA) and the first branch of the mesenteric aftery (FBMA). In the presence of 100 microM N(G)-nitro-L-arginine (L-NNA) and 10 microM indomethacin, ACh (1 nM to 100 microM) produced no relaxation in the phenylephrine-precontracted aorta. The L-NNA-resistant relaxations by ACh in MBMA precontracted with phenylephrine were eliminated in the presence of 1 microM nifedipine where contractions were independent of L-type Ca(2+) channel activation. In FBMA precontracted with phenylephrine, the L-NNA-resistant relaxations were only partially inhibited by nifedipine. When vessels had been contracted with 300 nM phorbol-12,13-dibutyrate in the presence of nifedipine, ACh-induced L-NNA-resistant relaxations were observed in FBMA only. Pinacidil produced relaxations in all different-sized blood vessels, although sensitivity was inversely related to vessel size. The extent of the ACh hyperpolarizing responses was much smaller than that by pinacidil in the aorta. The membrane potential changes by ACh and pinacidil were almost the same in FBMA. These results indicate that the contribution of EDHF to endothelium-dependent relaxations increases as the vessel size decreases. This may be partly explained by precontractile processes dependent on Ca(2+) entry through L-type Ca(2+) channels, because Ca(2+) channel deactivation seems to be involved as a major mechanism of EDHF-mediated vasorelaxations. However, EDHF may also generate vasorelaxations by an additional mechanism, probably a reduced Ca(2+) sensitivity of contractile elements, as proposed for ATP-sensitive K(+) channel openers.

Analysis of Variance↗

A unique, efficient, implantable, electromechanical, total artificial heart.

A completely implantable, one piece electromechanical total artificial heart (TAH) intended for permanent human use was developed. It consisted of left and right conically shaped pusher-plate blood pumps sandwiching a thin centerpiece with a compact, efficient electromechanical actuator. The actuator consisted of a direct current brushless motor; a planetary roller screw fit the space between the two conically shaped pusher-plates. The rotational motion of the motor was converted to the rectilinear motion of the rollerscrew to displace the left and right pusher-plates in the left master alternate mode. The diameter of the assembled TAH was 97 mm, with a central thickness of 82 mm. The overall weight was 620 g, with a displaced volume of 510 ml. The pump provided flows of 3-8 L/min with a preload of 1-15 mmHg against an afterload of 100 mmHg. The net efficiency ranged from 15% to 18%. This model showed good fit in the pericardial space of heart transplant recipients (body weight, 77 kg).

Cardiac Output↗

A biolized, compact, low noise, high performance implantable electromechanical ventricular assist system.

An implantable electromechanical ventricular assist system (VAS) intended for permanent human use was developed. It consisted of a conically shaped pumping chamber, a polyolefin (Hexsyn) rubber diaphragm attached to a pusher-plate, and a compact actuator with a direct current brushless motor and a planetary rollerscrew. The outer diameter was 97 mm, and the total thickness was 70 mm. This design was chosen to give a stroke volume of 63 ml. The device weighs 620 g, with a total volume of 360 ml. The pump can provide 8 L/min flow against 120 mmHg afterload with a preload of 10 mmHg. The inner surface of the device, including the pumping chamber and diaphragm, was made biocompatible with a dry gelatin coating. To date, two subacute (2 and 6 day) calf studies have been conducted. The pump showed reasonable anatomic fit inside the left thorax, and the entire system functioned satisfactorily in both the fill-empty mode using the Hall effect sensor signals and the conventional fixed rate mode. There were no thromboembolic complications despite no anticoagulation therapy. The system now is being endurance tested greater than 10 weeks (9 million cycles). This VAS is compact, low noise, easy to control, and has excellent biocompatibility.

Animals↗

Flow visualization evaluation of secondary flow in a centrifugal blood pump.

To design a less hemolytic and more antithrombogenic centrifugal blood pump, secondary flow, i.e., vortex and turbulent flow, must be properly controlled. An irregular stream pattern is a cause of hemolysis, and good wash-out around the shaft minimizes thrombus formation. In this study, flow visualization methods were applied to evaluate secondary flow in a centrifugal blood pump. Correlation with results of in vitro hemolysis tests was investigated. Separation of the stream lines from the vanes and patterns implying the existence of vortices were observed in the impeller that showed high hemolysis. By adjustment of vane angles, these irregular patterns could be minimized, and hemolysis decreased as well. Using a similar technique, the flow pattern at the back of the impeller could be visualized, which enabled further investigation of the effects of secondary flow on thrombus formation. This flow visualization was effective in examining secondary flow patterns.

Animals↗