Search PubMed⌕ Search

Biomedical subjects

I Pieper

Publications and source records attributed to I Pieper.

4 recordsLinked to original sources

[Congenital syphilis despite prenatal screening? An evaluation of 14 cases].

BACKGROUND: Congenital syphilis (CS) can be effectively avoided by adequate treatment of the mother during pregnancy. Nevertheless, in recent years, the Robert Koch Institute has reported 6-8 of CS cases per year. The aim of this study was to investigate cases of CS with regard to obstetrical history and results of maternal syphilis serology during pregnancy and postpartum. PATIENTS AND METHODS: Between 1997 and 2001, a total of 14 cases of CS were diagnosed after birth in the Stuttgart laboratory. Information on clinical and serological data obtained during prenatal care and at birth had been provided by the treating gynaecologists and paediatricians. Furthermore, serum samples from 11 of the 14 mothers were investigated at the Stuttgart laboratory after birth and also retrospectively at the Herford laboratory. RESULTS: All mothers presented without clinical signs of syphilis. Delayed prenatal care was observed in 6 out of 14 cases. Eleven of the 14 mothers had a positive treponemal screening test. Treatment was initiated only in two of them. During pregnancy treponemal IgM and cardiolipin antibodies were detected in none of 9 and in 5 of 8 sera of untreated mothers, respectively. In contrast, maternal serum samples investigated after birth were all positive for cardiolipin antibodies and 7 of 10 serum samples were positive for TP IgM antibodies. CONCLUSIONS: Delayed or absent prenatal care and misinterpretation of syphilis serology (or laboratory failures) in the presence of latent syphilis are mostly responsible for the inadequate management of syphilis during pregnancy and thus the occurrence of CS.

Adolescent↗

Iris angiography and aqueous photofluorometry in normal subjects.

Iris angiography and photofluorometry of the aqueous were performed on 44 normal subjects equally distributed between 15 and 65 years of age. Hemoglobin AIc determinations were performed in 20 of these persons. Leakage from the pupillary margin was present in 20% of the eyes studied. In all cases of leakage, the dye faded quickly after the initial peak concentration. No leakage was observed from radial iris vessels. Photofluorometric readings of the aqueous 60 minutes after injection increased significantly with age. Hemoglobin AIc measurements were observed to correlate significantly with aqueous fluorescein concentration. Both these observations may reflect an altered permeability of biologic membranes associated with aging.

Adolescent↗

Photogrammetry experiments with a model eye.

Digital photogrammetry was performed on stereophotographs of the optic nerve head of a modified Zeiss model eye in which optic cups of varying depths could be simulated. Experiments were undertaken to determine the impact of both photographic and ocular variables on the photogrammetric measurements of cup depth. The photogrammetric procedure tolerates refocusing, repositioning, and realignment as well as small variations in the geometric position of the camera. Progressive underestimation of cup depth was observed with increasing myopia, while progressive overestimation was noted with increasing hyperopia. High cylindrical errors at axis 90 degrees led to significant errors in cup depth estimates, while high cylindrical errors at axis 180 degrees did not materially affect the accuracy of the analysis. Finally, cup depths were seriously underestimated when the pupil diameter was less than 5.0 mm.

Astigmatism↗