A comparison of the use of Trachlight and Eschmann multiple-use introducer in simulated difficult intubation.

BACKGROUND AND OBJECTIVE: The Eschmann multiple-use introducer is widely used in the management of difficult intubations. Transillumination of the neck is less commonly used. We conducted a randomized crossover study comparing the Trachlight lightwand and Eschmann multiple-use introducer in simulated difficult intubation. METHODS: Sixty-four healthy patients were studied using a standard anaesthetic and full muscle relaxation assessed by train of four. A Macintosh laryngoscope was then inserted and then lowered to simulate a Grade 3 view. Tracheal placement was attempted with both Trachlight lightwand and Eschmann multiple-use introducer in a randomized order. Anaesthetists placing the devices had extensive experience with the Eschmann multiple-use introducer, but only 15 previous uses of the Trachlight. Success rates and time for tracheal placement were recorded. RESULTS: The Eschmann multiple-use introducer and Trachlight were successfully placed in 96.8% and 93.7%, respectively (n.s.). Mean (SD) time to intubation for Eschmann multiple-use introducer and Trachlight were 15(6) and *21(13), respectively (*P < 0.001). CONCLUSION: The Trachlight is a potentially useful alternative to the Eschmann multiple-use introducer in difficult intubation.

Female↗

A comparison of direct laryngoscopy and jaw thrust to aid fibreoptic intubation.

We compared two manoeuvres, jaw thrust and laryngoscopy, to open the airway during fibreoptic intubation in 50 patients after induction of anaesthesia in a crossover study. Patients were randomly allocated to receive either jaw thrust or conventional Macintosh laryngoscopy first. Airway clearance was assessed at both the soft palate and the epiglottis. Direct laryngoscopy provided significantly better airway clearance at the level of the soft palate than jaw thrust (44 (88%) vs 31 (62%), respectively; p = 0.002). At the level of the larynx, airway clearance was equally good in both groups (45 (90%) vs 46 (92%), respectively; p = 0.56). The times to view the larynx (median (interquartile range [range]) 4 (3-5 [2-35]) s vs 3 (3-4 [2-8]) s, respectively) and intubation time (20 (17-23 [11-83]) s vs 18 (15-20 [11-28]) s, respectively) were also similar.

Adult↗

Bougie-assisted difficult airway management in a manikin - the effect of position held on placement and force exerted by the tip.

In a randomised cross-over study, 50 anaesthetists attempted to place a multiple-use bougie in the trachea of a manikin, when holding it at either 20 cm or 30 cm from the tip. A grade 3 laryngoscopic view was simulated. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). The success rates when held at 20 and 30 cm distance from the tip were 68 and 62%, respectively (p = 0.55). In a separate experiment, multiple and single-use bougies were held at four different positions and pressed onto a disc attached to a force transducer. The peak force exerted by the single-use bougies was two to three times greater than that which could be exerted by the multiple-use bougies (p < 0.0001). Holding the bougie at either 20 or 30 cm distance from the tip is unlikely to influence bougie placement. The single-use bougie is much more likely to cause trauma to tissue during placement, particularly if held close to the tip.

Cross-Over Studies↗

Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer.

In a randomised cross-over study, 48 anaesthetists attempted to place a Frova single-use introducer, an Eschmann multiple-use introducer and a Portex single-use introducer in the trachea of a manikin set up to simulate a grade 3 laryngoscopic view. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). Successful placement (proportion, 95% confidence interval) of either the Frova introducer (65%, 50-77%) or the Eschmann introducer (60%, 46-73%) was significantly more likely than with the Portex introducer (8%, 3-20%). There were no significant differences between the success rates for the Frova and the Eschmann introducers. A separate experiment revealed that the peak force exerted by the Frova and Portex introducers was two to three times greater than that which could be exerted by the Eschmann introducer, p < 0.0001, indicating that the single-use introducers are more likely to cause tissue trauma during placement.

Analysis of Variance↗

Difficult Airway Society guidelines for management of the unanticipated difficult intubation.

UNLABELLED: Problems with tracheal intubation are infrequent but are the most common cause of anaesthetic death or brain damage. The clinical situation is not always managed well. The Difficult Airway Society (DAS) has developed guidelines for management of the unanticipated difficult tracheal intubation in the non-obstetric adult patient without upper airway obstruction. These guidelines have been developed by consensus and are based on evidence and experience. We have produced flow-charts for three scenarios: routine induction; rapid sequence induction; and failed intubation, increasing hypoxaemia and difficult ventilation in the paralysed, anaesthetised patient. The flow-charts are simple, clear and definitive. They can be fully implemented only when the necessary equipment and training are available. The guidelines received overwhelming support from the membership of the DAS. DISCLAIMER: It is not intended that these guidelines should constitute a minimum standard of practice, nor are they to be regarded as a substitute for good clinical judgement.

Adult↗

Prehospital airway management in Ambulance Services in the United Kingdom.

A postal survey of the 38 Ambulance Services in the United Kingdom was undertaken to find out what equipment is provided for paramedic crews to aid tracheal intubation and to confirm tracheal placement. The response rate to our survey was 100%. Fourteen (37%) ambulance services provided neither stylet nor bougie to facilitate difficult intubation. The laryngeal mask airway was available to 15 (40%) ambulance services. Seventeen (45%) ambulance services had use of a needle cricothyroidotomy set. Twenty-nine (76%) ambulance services had no type of device other than a stethoscope to confirm tracheal tube placement. This survey showed wide variations in the equipment for airway management available to paramedic crews in the United Kingdom. We recommend provision of a standard set of airway management equipment to all paramedic crews in the United Kingdom together with introduction of appropriate training programmes.

Emergency Medical Services↗

Changes in cerebral oxygenation during cold (28 degrees C) and warm (34 degrees C) cardiopulmonary bypass using different blood gas strategies (alpha-stat and pH-stat) in patients undergoing coronary artery bypass graft surgery.

BACKGROUND: Impaired cerebral oxygenation, which is reflected by measuring jugular bulb oxygenation, is thought to play an important role in the development of neurological injury after cardiac operations with cardiopulmonary bypass (CPB). The effects of cardiopulmonary temperature and blood gas strategy on cerebral oxygenation are not fully appreciated. METHODS: Sixty patients were randomly allocated into four equal groups (cold alpha-stat, cold pH-stat, warm alpha-stat and warm pH-stat) to compare the effect of these perfusion strategies on cerebral oxygenation monitored by jugular bulb oximetry [jugular bulb oxygen saturation (SjO(2)) and arterial-jugular bulb oxygen content difference (AjDO(2))]. Jugular bulb oxygen saturation and AjDO(2) were measured before CPB, after 5, 20, 40 min on CPB, at start and end of rewarming, 5 min before the end of CPB and 10 min after CPB. Two-way analysis of variance was used to model the lowest SjO(2) and highest AjDO(2) during CPB, with CPB temperature and blood gas management as contributing factors. RESULTS: Significant changes in SjO(2) were only related to the type of blood gas management, with no significant difference between warm and cold CPB patients. In addition, during rewarming, desaturation (SjO(2) </= 50%) occurred in seven patients of 30 in the alpha-stat groups and in one patient of 30 in the pH-stat groups (P = 0.021), and in five patients of 30 in the cold groups vs. three of 30 in the warm groups (P = 0.434). However, no significant changes were found in the highest AjDO(2) between the four groups. CONCLUSION: Cold CPB failed to offer any further brain protection in terms of better preservation of cerebral oxygenation than warm CPB. Therefore, warm CPB (34 degrees C) with different blood gas strategies appears to be a satisfactory alternative to cold CPB (28 degrees C).

Aged↗

A comparison of simulated difficult intubation with multiple-use and single-use bougies in a manikin.

In a randomised cross-over study, 20 anaesthetists attempted to place a multiple- or single-use bougie in the trachea of a manikin, in which a grade 3 Cormack and Lehane laryngoscopic view was simulated. The anaesthetists made two attempts at placement with each bougie and were blinded to success (tracheal placement) or failure (oesophageal placement). The success rates for the first attempts with the multiple- and single-use bougies were 85 and 15%, respectively [mean (95% CI) difference between the two bougies 70% (40-84%); p < 0.001]. The success rates for the second attempts were similar to those for the first attempts with both bougies. There is an increased risk of failure to intubate the trachea when using a single-use bougie, and this must be weighed against the unquantified risk of cross-infection from prions when using a multiple-use bougie.

Clinical Competence↗

Prevalence of a training module for difficult airway management: a comparison between Japan and the United Kingdom.

To examine the education of trainees with regard to difficult airway management, we sent a questionnaire to all 89 Japanese University Departments of Anaesthesia (to be answered by a person who was responsible for teaching trainees) and all 280 Royal College of Anaesthetists' Tutors in the UK. The presence or absence of a formal training module for difficult airway management, timing and methods of training, types of airway devices that should be taught, and tutors' expertise with various techniques and devices were surveyed. Sixty-seven of the 89 Japanese tutors (75%) and 167 of 280 UK tutors (60%) replied to the questionnaire. Only 19 of 67 (28%) Japanese anaesthetists and 33 of 167 (20%) UK anaesthetists who replied, indicated that they had a difficult airway training module. In six Japanese departments (9%) and 115 (69%) UK departments, equipment for percutaneous transtracheal ventilation was readily available. Airway devices and techniques that tutors considered necessary to be mastered in the first 2 years of training, differed considerably between Japan and the UK, with notable differences in the use of gum elastic bougies and awake intubation. A training module for difficult airway management is often not provided and equipment for emergency transtracheal ventilation is often unavailable in both countries.

Anesthesiology↗

The rigid nasendoscope as a tool for difficult tracheal intubation: a manikin study.

We examined the use of the 30 degrees rigid nasendoscope in aiding difficult tracheal intubations. A Cormack and Lehane grade 4 difficult intubation (no view of glottis or epiglottis) was set up on a manikin. After 10 s of tuition, 40 anaesthetists attempted to pass a standard gum elastic bougie between the cords, with and without the nasendoscope, in randomised order. A bougie curved to an 'optimal curve' was also tested. Using the standard bougie 13/40 (33%) passed the bougie between the cords without the nasendoscope, compared with 31/40 (78%) when using the nasendoscope (p < 0.001). The 'optimal curve' bougie resulted in 29/40 (73%) and 39/40 (98%) success rates without and with the nasendoscope, respectively (p = 0.004). The nasendoscope is a simple and easy to use tool in grade 4 intubation, and results are improved further by the use of an 'optimal curve' bougie.

Attitude of Health Personnel↗

To shape or not to shape...simulated bougie-assisted difficult intubation in a manikin.

Thirty anaesthetists attempted to place a derived 'optimal' curve bougie or a straight bougie in the trachea of a manikin, in a randomised cross-over study. A Grade 3 Cormack and Lehane laryngoscopic view was simulated. The anaesthetists were blinded to success (tracheal placement) or failure (oesophageal placement). The success rates with the curved and straight bougies were 83 and 7%, respectively, giving a difference (95% confidence interval) of 77% (54-87%) between the two bougies (p < 0.0001). On a separate occasion, under identical laboratory conditions, 30 anaesthetists attempted to place a straight coudé (angled)-tipped bougie or a straight straight-tipped bougie in the trachea of a manikin. The success rates with the coudé- and straight-tipped bougies were 43 and 0%, respectively, giving a difference (95% confidence interval) of 43% (21-61%) between the two bougies (p < 0.001). These results suggest that bougies used to facilitate difficult intubation should be curved and have a coudé tip.

Clinical Competence↗

Survey of the use of the gum elastic bougie in clinical practice.

Data were collected prospectively on the use of the gum elastic bougie in 200 patients. The bougie was successfully inserted into the trachea and tracheal intubation was accomplished in 199 cases. The bougie was inserted into the trachea at the first attempt in 178 cases. In nine cases (4.5%) a second, more experienced, clinician was required. In 173 cases, the grades of view were recorded before and after the application of laryngeal pressure; pressure improved the view in 80 cases (46%), had no effect in 89 (51%) and worsened the view in four cases (2%). Various recommendations for optimal external laryngeal pressure and use of the bougie were not followed on 15-64% of occasions. There is a need for better education in these techniques.

Adolescent↗

Changes in serum S100beta protein and Mini-Mental State Examination after cold (28 degrees C) and warm (34 degrees C) cardiopulmonary bypass using different blood gas strategies (alpha-stat and pH-stat).

BACKGROUND: The effect of cardiopulmonary bypass temperature and blood gas management on the brain is still controversial. This study was designed to compare the changes in S100beta protein concentration and Mini-Mental State Examination in patients undergoing cold (28 degrees C) vs. warm (34 degrees C) cardiopulmonary bypass using different blood gas strategies (alpha-stat and pH-stat). METHODS: Sixty patients were randomly allocated to one of four equal groups (cold alpha-stat, cold pH-stat, warm alpha-stat, warm pH-stat). Serum S100beta concentrations were measured before CPB, directly after CPB, at 4.5 h and at 24 h after CPB. Mini-Mental State Examination was performed one day before surgery and on day five after the operation. Antegrade warm blood cardioplegia (37 degrees C) was used in all patients. RESULTS: There was no significant difference in postoperative S100beta protein levels between the four groups. Also, there was no interaction between bypass temperature and type of blood gas strategy on S100beta levels after bypass (directly after bypass, 4.5 h and 24 h after bypass). Mini-Mental State Examination score was not affected by blood gas strategy but it was significantly lower in patients undergoing cold cardiopulmonary bypass surgery: median (range), 26 (12-29) vs. 27 (23-30) in warm patients, P = 0.014. There was no significant correlation between Mini-Mental State Examination score 5 days after CPB and S100beta levels at any of the studied time-points after CPB. CONCLUSION: These results support the use of warm CPB (34 degrees C) in patients undergoing coronary artery bypass surgery regardless of the type of blood gas strategy.

Carbon Dioxide↗