Search PubMed⌕ Search

Biomedical subjects

I P Kay

Publications and source records attributed to I P Kay.

At least 37 records · Page 2Linked to original sources

Collateral recruitment and "warm-up" after first exercise in ischemic heart disease.

BACKGROUND: Proposed mechanisms for "warm-up" after angina on first exercise include ischemic preconditioning and collateral recruitment. The aim of this study was to determine whether patients with ischemic heart disease and well-developed coronary collateral vessels have a greater warm-up response than those with no visible collateral vessels. METHODS AND RESULTS: Fifteen patients with a total coronary occlusion and collateral vessels and 18 patients with a single coronary artery stenosis and no angiographically visible collateral vessels were studied. Warm-up was measured as the difference in ST depression on the second compared with the first of 2 sequential treadmill exercise tests separated by 10 minutes of rest. There was a trend for the duration of second exercise to increase more in patients with occlusion than in those with stenosis (+1.3 vs +0.54 minutes, respectively, P =.087). In both groups, ST depression was less on second exercise than on first exercise. The size of this decrease was greater in the occlusion group than in the stenosis group. ST depression at equivalent submaximal exercise decreased by 0.52 vs 0.19 mm, respectively (P =.049). The rate of increase in ST depression during exercise decreased by 1.08 versus 0. 55 mm/min, respectively (P =.034). These differences were less after adjustment for ST depression on first exercise (P =.11 and P =.063, respectively). CONCLUSIONS: The trend for a greater decrease in ST depression on second compared with first exercise in the patients with total coronary occlusion suggests that an increase in collateral flow is a mechanism for warm-up after first exercise in ischemic heart disease.

Aged↗

Evaluation of left ventricular volumes and ejection fraction with a nonfluoroscopic endoventricular three-dimensional mapping technique.

BACKGROUND: Recently, a novel nonfluoroscopic 3-dimensional electromechanical mapping technique was introduced in the clinical arena. Although initial in vitro and in vivo studies suggested the reliability of the system in volumetric and hemodynamic evaluation of the left ventricle, no validation in human beings has been performed. METHODS: A nonfluoroscopic electromechanical mapping (NOGA, Biosense-Webster) procedure was performed in 44 patients. All patients received a contrast left ventriculogram during the same session. Volumetric (end-diastolic [EDV] and end-systolic volumes [ESV]) and hemodynamic (left ventricular ejection fraction [LVEF] and stroke volume) parameters of both systems were compared. RESULTS: Two uncomplicated pericardial effusions occurred with the first-generation mapping catheters. No procedural complications were noted with the new-generation mapping catheters. Significant correlations were found between mapping-derived and ventriculography-based measurements for both ESV (r = 0.67, P <.001) and LVEF (r = 0.78, P <.001). Absolute volumes, however, were only comparable for ESV (46.6 +/- 25.3 mL vs 48.8 +/- 37.0 mL, respectively; P =.13) but differed greatly for LVEF (35% +/- 13% vs 65% +/- 19%, respectively; P <.001), EDV (69.1 +/- 28.6 mL vs 125.9 +/- 53.4 mL, respectively; P <.001) and stroke volume (22.4 +/- 9.9 mL vs 77.1 +/- 33.7 respirations; P <.001). Moreover, Bland-Altman analysis showed the clinical noninterchangeability between these techniques for the measurement of hemodynamic parameters. CONCLUSION: Measurement of hemodynamic parameters with nonfluoroscopic mapping of the left ventricle is feasible and safe. The system provides data that strongly correlate but that are in clinical disagreement with angiographic data. Therefore the interchangeability of these techniques may be questioned.

Algorithms↗

Improved coronary artery flow after coronary angioplasty in patients with unstable angina.

BACKGROUND: Coronary artery flow is impaired after myocardial infarction but there is limited information regarding coronary flow in unstable angina. AIM: To assess baseline coronary artery flow and the effects of coronary angioplasty on coronary flow in patients with unstable angina. METHODS: Twenty-one patients with unstable angina with a culprit lesion suitable for coronary angioplasty were enrolled in the study. Coronary flow was assessed with the Thrombolysis In Myocardial Infarction (TIMI) grade and the Corrected TIMI Frame Count (CTFC) pre and post angioplasty. RESULTS: Baseline flow was impaired in the culprit artery compared to the non culprit artery (42.0+/-28.1 vs 25.3+/-7.0 frames, p<0.02). Pre angioplasty coronary flow was TIMI grade 2 in 52% and TIMI grade 3 in 48% of patients. Post angioplasty flow improved with TIMI grade 2 flow in 5% and TIMI grade 3 in 95%. After angioplasty coronary flow improved from 42.0+/-28.1 frames to 21.6+/-16.3 (p=0.0001). The culprit coronary stenosis decreased from 74+/-9% pre angioplasty to 28+/-12% after intervention (p=0.0001). CONCLUSIONS: Angioplasty and stenting of the culprit vessel restores normal coronary flow in most patients with unstable angina. This suggests that impaired flow in unstable angina is predominantly related to the culprit lesion residual stenosis.

Adult↗

Outcome from balloon induced coronary artery dissection after intracoronary beta radiation.

OBJECTIVE: To evaluate the healing of balloon induced coronary artery dissection in individuals who have received beta radiation treatment and to propose a new intravascular ultrasound (IVUS) dissection score to facilitate the comparison of dissection through time. DESIGN: Retrospective study. SETTING: Tertiary referral centre. PATIENTS: 31 patients with stable angina pectoris, enrolled in the beta energy restenosis trial (BERT-1.5), were included. After excluding those who underwent stent implantation, the evaluable population was 22 patients. INTERVENTIONS: Balloon angioplasty and intracoronary radiation followed by quantitative coronary angiography (QCA) and IVUS. Repeat QCA and IVUS were performed at six month follow up. MAIN OUTCOME MEASURES: QCA and IVUS evidence of healing of dissection. Dissection classification for angiography was by the National Heart Lung Blood Institute scale. IVUS proven dissection was defined as partial or complete. The following IVUS defined characteristics of dissection were described in the affected coronary segments: length, depth, arc circumference, presence of flap, and dissection score. Dissection was defined as healed when all features of dissection had resolved. The calculated dose of radiation received by the dissected area in those with healed versus non-healed dissection was also compared. RESULTS: Angiography (type A = 5, B = 7, C = 4) and IVUS proven (partial = 12, complete = 4) dissections were seen in 16 patients following intervention. At six month follow up, six and eight unhealed dissections were seen by angiography (A = 2, B = 4) and IVUS (partial = 7, complete = 1), respectively. The mean IVUS dissection score was 5.2 (range 3-8) following the procedure, and 4.6 (range 3-7) at follow up. No correlation was found between the dose prescribed in the treated area and the presence of unhealed dissection. No change in anginal status was seen despite the presence of unhealed dissection. CONCLUSION: beta radiation appears to alter the normal healing process, resulting in unhealed dissection in certain individuals. In view of the delayed and abnormal healing observed, long term follow up is indicated given the possible late adverse effects of radiation. Although in this cohort no increase in cardiac events following coronary dissections was seen, larger populations are needed to confirm this phenomenon. Stenting of all coronary dissections may be warranted in patients scheduled for brachytherapy after balloon angioplasty.

Angina Pectoris↗

The effect of 32P beta-radiotherapy on both vessel remodeling and neointimal hyperplasia after coronary balloon angioplasty and stenting: a three-dimensional intravascular ultrasound investigation.

Intracoronary radiation is a promising therapy to decrease restenosis after percutaneous intervention. The aim of this pilot study was to determine the mechanism of intracoronary beta-radiation after balloon angioplasty and stenting in a double-blind placebo-controlled randomized fashion. Twenty-six patients were randomized to either placebo (n = 6) or 3 doses (28, 35 and 42 Gy) of beta-radiation (n = 20) using the Guidant brachytherapy system (27 mm long 32P source wire). Of these, 21 patients underwent post-procedure and 6-month follow-up three-dimensional intravascular ultrasound (IVUS) assessment. Volumetric quantification was performed by means of a semi-automated contour detection system after an ECG-gated motorized pullback IVUS imaging and three-dimensional reconstruction. We compared the volumetric changes (Delta) of total vessel volume (TVV), plaque volume (PV) and lumen volume (LV) after 6 months between placebo (dummy wire) and irradiated patients. In addition, the volume of neointimal hyperplasia was quantified within the stented segments. There was an opposite behavior of TVV and LV change between placebo (DeltaTVV = -24 mm3 and DeltaLV = -42 mm3) and irradiated (DeltaTVV = +18 mm3 and (DeltaLV = +5 mm3) patients. The mean neointimal formation within the stented segment in the irradiated patients (n = 7) was 1.9 mm3 (1.5%). Our results suggest that beta-radiation affects vessel remodeling after percutaneous intervention and inhibit neointimal formation in stented patients.

Aged↗

beta-Particle-emitting radioactive stent implantation. A safety and feasibility study.

BACKGROUND: This study represents the Heart Center Rotterdam's contribution to the Isostents for Restenosis Intervention Study, a nonrandomized multicenter trial evaluating the safety and feasibility of the radioactive Isostent in patients with single coronary artery disease. Restenosis after stent implantation is primarily caused by neointimal hyperplasia. In animal studies, beta-particle-emitting radioactive stents decrease neointimal hyperplasia by inhibiting smooth muscle cell proliferation. METHODS AND RESULTS: The radioisotope (32)P, a beta-particle emitter with a half-life of 14.3 days, was directly embedded into the Isostent. The calculated range of radioactivity was 0.75 to 1.5 microCi. Quantitative coronary angiography measurements were performed before and after the procedure and at 6-month follow-up. A total of 31 radioactive stents were used in 26 patients; 30 (97%) were successfully implanted, and 1 was embolized. Treated lesions were in the left anterior descending coronary artery (n=12), the right coronary artery (n=8), or the left circumflex coronary artery (n=6). Five patients received additional, nonradioactive stents. Treated lesion lengths were 13+/-4 mm, with a reference diameter of 2.93+/-0. 47 mm. Minimum lumen diameter increased from 0.87+/-0.28 mm preprocedure to 2.84+/-0.35 mm postprocedure. No in-hospital adverse cardiac events occurred. All patients received aspirin indefinitely and ticlopidine for 4 weeks. Twenty-three patients (88%) returned for 6-month angiographic follow-up; 17% of them had in-stent restenosis, and 13% had repeat revascularization. No restenosis was observed at the stent edges. Minimum lumen diameter at follow-up averaged 1.85+/-0.69 mm, which resulted in a late loss of 0.99+/-0. 59 mm and a late loss index of 0.53+/-0.35. No other major cardiac events occurred during the 6-month follow-up. CONCLUSIONS: The use of radioactive stents with an activity of 0.75 to 1.5 microCi is safe and feasible.

Adult↗

Preserved endothelium-dependent vasodilation in coronary segments previously treated with balloon angioplasty and intracoronary irradiation.

BACKGROUND: Abnormal endothelium-dependent coronary vasomotion has been reported after balloon angioplasty (BA), as well as after intracoronary radiation. However, the long-term effect on coronary vasomotion is not known. The aim of this study was to evaluate the long-term vasomotion of coronary segments treated with BA and brachytherapy. METHODS AND RESULTS: Patients with single de novo lesions treated either with BA followed by intracoronary beta-irradiation (according to the Beta Energy Restenosis Trial-1.5) or with BA alone were eligible. Of these groups, those patients in stable condition who returned for 6-month angiographic follow-up formed the study population (n=19, irradiated group and n=11, control group). Endothelium-dependent coronary vasomotion was assessed by selective infusion of serial doses of acetylcholine (ACh) proximally to the treated area. Mean luminal diameter was calculated by quantitative coronary angiography both in the treated area and in distal segments. Endothelial dysfunction was defined as a vasoconstriction after the maximal dose of ACh (10(-6) mol/L). Seventeen irradiated segments (89.5%) demonstrated normal endothelial function. In contrast, 10 distal nonirradiated segments (53%) and 5 control segments (45%) demonstrated endothelium-dependent vasoconstriction (-19+/-17% and -9.0+/-5%, respectively). Mean percentage of change in mean luminal diameter after ACh was significantly higher in irradiated segments (P=0.01). CONCLUSIONS: Endothelium-dependent vasomotion of coronary segments treated with BA followed by beta-radiation is restored in the majority of stable patients at 6-month follow-up. This functional response appeared to be better than those documented both in the distal segments and in segments treated with BA alone.

Acetylcholine↗

Geometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study.

BACKGROUND: Endovascular radiation appears to inhibit intimal thickening after overstretching balloon injury in animal models. The effect of brachytherapy on vascular remodeling is unknown. The aim of the study was to determine the evolution of coronary vessel dimensions after intracoronary irradiation after successful balloon angioplasty in humans. METHODS AND RESULTS: Twenty-one consecutive patients treated with balloon angioplasty and beta-radiation according to the Beta Energy Restenosis Trial-1.5 were included in the study. Volumetric assessment of the irradiated segment and both edges was performed after brachytherapy and at 6-month follow-up. Intravascular ultrasound images were acquired by means of ECG-triggered pullback, and 3-D reconstruction was performed by automated edge detection, allowing the calculation of lumen, plaque, and external elastic membrane (EEM) volumes. In the irradiated segments, mean EEM and plaque volumes increased significantly (451+/-128 to 490.9+/-159 mm(3) and 201.2+/-59 to 241.7+/-74 mm(3); P=0.01 and P=0.001, respectively), whereas luminal volume remained unchanged (250.8+/-91 to 249.2+/-102 mm(3); P=NS). The edges demonstrated an increase in mean plaque volume (26.8+/-12 to 32. 6+/-10 mm(3), P=0.0001) and no net change in mean EEM volume (71. 4+/-24 to 70.9+/-24 mm(3), P=NS), resulting in a decrease in mean luminal volume (44.6+/-16 to 38.3+/-16 mm(3), P=0.01). CONCLUSIONS: A different pattern of remodeling is observed in coronary segments treated with beta-radiation after successful balloon angioplasty. In the irradiated segments, the adaptive increase of EEM volume appears to be the major contributor to the luminal volume at follow-up. Conversely, both edges showed an increase in plaque volume without a net change in EEM volume.

Angioplasty, Balloon↗

Late coronary occlusion after intracoronary brachytherapy.

BACKGROUND: Intracoronary brachytherapy appears to be a promising technology to prevent restenosis. Presently, limited data are available regarding the late safety of this therapeutic modality. The aim of the study was to determine the incidence of late (>1 month) thrombosis after PTCA and radiotherapy. METHODS AND RESULTS: From April 1997 to March 1999, we successfully treated 108 patients with PTCA followed by intracoronary beta-radiation. Ninety-one patients have completed at least 2 months of clinical follow-up. Of these patients, 6.6% (6 patients) presented with sudden thrombotic events confirmed by angiography 2 to 15 months after intervention (2 balloon angioplasty and 4 stent). Some factors (overlapping stents, unhealed dissection) may have triggered the thrombosis process, but the timing of the event is extremely unusual. Therefore, the effect of radiation on delaying the healing process and maintaining a thrombogenic coronary surface is proposed as the most plausible mechanism to explain such late events. CONCLUSIONS: Late and sudden thrombosis after PTCA followed by intracoronary radiotherapy is a new phenomenon in interventional cardiology.

Aged↗

Remodeling of atherosclerotic coronary arteries varies in relation to location and composition of plaque.

The aim of this study was to determine the contribution of morphologic characteristics and location of plaque in remodeling of atherosclerotic coronary arteries. Consecutive intravascular ultrasound studies performed in native coronary arteries before an intervention were included in the study. Total vessel, lumen and plaque + media areas were measured at target lesion, and distal and proximal references. Remodeling index was calculated as target total vessel area/proximal reference total vessel area, and categorized into 3 groups based on relative total vessel-area ratio: (1) > 1.1 (group A, adequate remodeling); (2) 0.9 to 1.1 (group B, failure of compensatory enlargement); and (3) <0.9 (group C, coronary shrinkage). Eighty-nine narrowings were assessed in 80 intravascular ultrasound studies. Thirty-eight lesions (43%) were defined as soft and 51 (57%) as hard. Soft plaques were more prevalent in group A than in groups B and C (p = 0.001). Conversely, the arc of calcium was larger in group C lesions (p = 0.005). At distal segments, group A lesions were more prevalent than those in groups B and C, whereas at proximal segments group C lesions were more prevalent (p = 0.007). Multivariate analysis identified the arc of calcium and the location of plaque at distal segments as independent predictors of compensatory enlargement (odds ratio 0.94, 95% confidence interval 0.90 to 0.99; odds ratio 4.6; 95% confidence interval 1.4 to 15.7, respectively), whereas hard plaques were an independent predictor of coronary shrinkage (odds ratio 4.6; 95% confidence interval 1.7 to 12.5). In conclusion, composition and location of plaque appeared to be major determinants of vessel remodeling during the process of atherosclerosis.

Analysis of Variance↗

Quantitative measurements of in-stent restenosis: A comparison between quantitative coronary ultrasound and quantitative coronary angiography.

While quantitative coronary angiography (QCA) remains the standard used to assess new interventional therapies, intracoronary ultrasound (ICUS) is gaining interest. The aim of the study was to determine the relationship between QCA and quantitative coronary ultrasound (QCU) measurements after stenting. Sixty-two consecutive patients with both QCA and QCU analysis after stent implantation were included in the study. The mean luminal diameter (QCU vs. QCA) were 2.74 +/- 0.46 mm and 2.41 +/- 0.49 mm (P < 0.0001), the minimal luminal diameter (MLD) 2.08 +/- 0.44 mm and 1.62 +/- 0.42 mm (P < 0. 0001), and the projected QCU MLD 1.90 +/- 0.42 mm (P < 0.0001 with respect to QCA). Percentage obstruction diameter (QCU vs. QCA) were 41.53% +/- 10.78% and 43.15% +/- 12.72% (P = NS). The stent diameter (QCU vs. QCA) were 3.54 +/- 0.65 mm and 3.80 +/- 0.37 mm (P = 0. 0004). Stent length measured by QCU were longer at 31.11 +/- 13.54 mm against 28.63 +/- 12.75 mm, P < 0.0001 with respect to QCA. In conclusion, while QCA and QCU appear to be comparable tools for measuring corrected stent diameters and stent lengths, smaller luminal diameters were found using QCA. This is of particular relevance to quantitative studies addressing absolute changes in vascular or luminal diameters. Cathet. Cardiovasc. Intervent. 48:133-142, 1999.

Aged↗

Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months: results of a meta-analysis of the BElgian NEtherlands Stent study (BENESTENT) I, BENESTENT II Pilot, BENESTENT II and MUSIC trials. Multicenter Ultrasound Stent In Coronaries.

OBJECTIVES: We aimed to identify periprocedural quantitative coronary angiographic (QCA) variables that have predictive value on long-term angiographic results and to construct multivariate models using these variables for postprocedural prognosis. BACKGROUND: Coronary stent implantation has reduced the restenosis rate significantly as compared with balloon angioplasty in short de novo lesions in coronary arteries >3 mm in size. Although the postprocedural minimal luminal diameter (MLD) is known to have significant bearing on long-term angiographic results, no practically useful model exists for prediction of angiographic outcome based on the periprocedural QCA variables. METHODS: The QCA data from patients who underwent Palmaz-Schatz stent implantation for short (<15 mm) de novo lesions in coronary arteries >3 mm and completed six months of angiographic follow-up in the four prospective clinical trials (BENESTENT I, BENESTENT II pilot, BENESTENT II and MUSIC) were pooled. Multiple models were constructed using multivariate analysis. The Hosmer-Lemeshow goodness-of-fit test was used to identify the model of best fit, and this model was used to construct a reference chart for prediction of angiographic outcome on the basis of periprocedural QCA variables. RESULTS: Univariate analysis performed using QCA variables revealed that vessel size, MLD before and after the procedure, reference area before and after the procedure, minimal luminal cross-sectional area before and after the procedure, diameter stenosis after the procedure, area of plaque after the procedure and area stenosis after the procedure were significant predictors of angiographic outcome. Using multivariate analysis, the Hosmer-Lemeshow goodness-of-fit test showed that the model containing percent diameter stenosis after the procedure and vessel size best fit the data. A reference chart was then developed to calculate the expected restenosis rate. CONCLUSIONS: Restenosis rate after stent implantation for short lesions can be predicted using the variables percent diameter stenosis after the procedure and vessel size. This meta-analysis indicates that the concept of "the bigger the better" holds true for coronary stent implantation. Applicability of the model beyond short lesions should be tested.

Adult↗

Elective Wiktor GX stenting for symptomatic stenosis in old aortocoronary saphenous vein bypass grafts: the Antwerp experience.

PURPOSE: We compared initial outcome, peri-procedural complications and long-term clinical follow-up of elective Wiktor GX stent implantation in severely narrowed vein grafts to a historic register of elective angioplasties in saphenous vein grafts in the same center. METHODS: Eighty-one consecutive patients with angina and a history of coronary artery bypass grafting (CABG), all received elective angioplasty (PTCA) of the diseased graft; we described them as group P. The next 38 consecutive patients were treated with elective angioplasty and Wiktor Stent implantation, followed by one month ticlopidine; they were called group S. CONCLUSION: This retrospective study suggests that elective Wiktor stenting in old saphenous vein graft stenosis, in combination with one month ticlopidine, leads to: 1) a better angiographic result, with reduction of peri-procedural complications; and 2) a lower incidence of recurrent angina, need for invasive or surgical re-intervention, myocardial infarction and death during follow-up.

Aged↗

Compassionate use of intracoronary beta-irradiation for treatment of recurrent in-stent restenosis.

Recurrent in-stent restenosis after balloon angioplasty poses a serious management problem. Previously g-radiation has been shown to be effective in patients with in-stent restenosis. The aim of the study was to determine the feasibility and safety of b-radiation in patients with recurrent in-stent restenosis. From May 1997 to December 1998, 18 patients were treated with balloon angioplasty (n = 8) or laser (n = 10), followed by intracoronary b-radiation at a prescribed dose of 16 Gray at 2 mm from the source, for reference diameters by quantitative coronary angiography < 3.25 mm or 20 Gray for reference diameters > or =3.25 mm. Vessels treated were as follows: left anterior descending: (n = 5); circumflex: (n = 4); right coronary artery: (n = 6); saphenous vein graft: (n = 3). Average recurrence rate was 2.4 +/- 0.7 and the restenotic length was 16 +/- 7 mm. b-radiation was successfully delivered in all patients. Two patients presented complications related to laser debulking: a non-Q wave myocardial infarction in one and a re-angioplasty due to uncovered distal dissection in another. Geographical miss, defined as an area which has been injured but not covered by the radiation source, was demonstrated in 8 patients. Seventeen patients (94%) completed the 6-month angiographic follow-up. Restenosis (> 50% Diameter Stenosis) was observed in 9 patients (53%), leading to target lesion revascularization in 8 patients (47%). Six of the 9 restenoses were located in areas with geographical miss. Intracoronary b-radiation for recurrent in-stent restenosis appears to be a safe and feasible management strategy. However, the mismatch between injured and irradiated area may lead to failure of this therapy.

Aged↗