Search PubMed⌕ Search

Biomedical subjects

I P Jones

Publications and source records attributed to I P Jones.

4 recordsLinked to original sources

Diffusing acoustic wave spectroscopy.

We have developed a technique in ultrasonic correlation spectroscopy called diffusing acoustic wave spectroscopy (DAWS). In this technique, the motion of the scatterers (e.g., particles or inclusions) is determined from the temporal fluctuations of multiply scattered sound. In DAWS, the propagation of multiply scattered sound is described using the diffusion approximation, which allows the autocorrelation function of the temporal field fluctuations to be related to the dynamics of the multiply scattering medium. The expressions relating the temporal field autocorrelation function to the motion of the scatterers are derived, focusing on the types of correlated motions that are most likely to be encountered in acoustic measurements. The power of this technique is illustrated with ultrasonic data on fluidized suspensions of particles, where DAWS provides a sensitive measure of the local relative velocity and strain rate of the suspended particles over a wide range of time and length scales. In addition, when combined with the measurements of the rms velocity of the particles using dynamic sound scattering, we show that DAWS can be used to determine the spatial extent of the correlations in the particle velocities, thus indirectly measuring the particle velocity correlation function. Potential applications of diffusing acoustic wave spectroscopy are quite far reaching, ranging from the ultrasonic nondestructive evaluation of the dynamics of inhomogeneous materials to geophysical studies of mesoscopic phenomena in seismology.

Journal Article↗

Wave transport in random media: the ballistic to diffusive transition.

The character of wave transport through a strongly scattering medium, excited by a pulsed plane-wave source, is investigated as a function of sample thickness over the range from about one to 13 mean free paths. To examine the behavior theoretically, we perform a first-principles calculation of both the frequency correlation function of the transmitted field and the time-domain profile of the transmitted intensity. These quantities are investigated experimentally using an ultrasonic technique, which allows us to separate the ballistic and scattered components of the total transmitted field, and hence to measure the scattered component unambiguously in thin samples. For sample thicknesses greater than about four mean free paths, we find good agreement between our theory, the diffusion approximation, and our experimental data for both the frequency correlation function and the intensity time profile. In thinner samples, there are systematic differences between theory and experiment. To characterize the transition from ballistic to diffusive behavior in thin samples, we focus on the arrival time of the peak in the scattered component of the transmitted intensity; unexpectedly we find that the scattered peak arrival time exhibits an abrupt crossover between ballistic and diffusive behavior when the ratio of sample thickness to mean free path, L/l, is approximately equal to 3. Excellent agreement is obtained between our theory and experiment for this crossover behavior over the entire range of sample thicknesses investigated.

Journal Article↗

Electron microscopy of materials at the University of Birmingham.

The School of Metallurgy and Materials has traditionally put transmission electron microscopy (TEM) in the forefront of its research interests and, through support from SERC and from the university, has always had the facility to carry out state of the art electron microscopy of materials. In this brief review some of the topics where TEM has played a central role in recent work in Birmingham will be described so that it will be seen just how central to the work in Birmingham TEM has been.

Alloys↗

Fluid-solid interaction: benchmarking of an external coupling of ANSYS with CFX for cardiovascular applications.

Fluid-solid interaction is a primary feature of cardiovascular flows. There is increasing interest in the numerical solution of these systems as the extensive computational resource required for such studies becomes available. One form of coupling is an external weak coupling of separate solid and fluid mechanics codes. Information about the stress tensor and displacement vector at the wetted boundary is passed between the codes, and an iterative scheme is employed to move towards convergence of these parameters at each time step. This approach has the attraction that separate codes with the most extensive functionality for each of the separate phases can be selected, which might be important in the context of the complex rheology and contact mechanics that often feature in cardiovascular systems. Penrose and Staples describe a weak coupling of CFX for computational fluid mechanics to ANSYS for solid mechanics, based on a simple Jacobi iteration scheme. It is important to validate the coupled numerical solutions. An extensive analytical study of flow in elastic-walled tubes was carried out by Womersley in the late 1950s. This paper describes the performance of the coupling software for the straight elastic-walled tube, and compares the results with Womersley's analytical solutions. It also presents preliminary results demonstrating the application of the coupled software in the context of a stented vessel.

Arteries↗