Search PubMed⌕ Search

Biomedical subjects

I L Smith

Publications and source records attributed to I L Smith.

56 records · Page 4Linked to original sources

Pharmacokinetics and extravascular penetration of aztreonam in patients with abdominal sepsis.

Patients with abdominal sepsis were enrolled in a clinical trial of aztreonam vs. tobramycin. All were given clindamycin concomitantly. The pharmacokinetics of aztreonam in 21 patients randomly assigned to receive treatment with aztreonam are reported. The mean age of these patients was 68 years; most had underlying disorders such as malnutrition and cardiac or pulmonary disease. Creatinine clearance (Clcr) ranged from 11.2 to 133.1 ml/min. The usual dose of aztreonam was 2.0 g every 8-12 hr. A single pharmacokinetic study was performed over one dosing interval after steady-state conditions were achieved. In approximately one-half of the patients, peritoneal fluid was collected during the interval between doses. Penetration of aztreonam, as expressed as the ratio of concentration in the peritoneal fluid to that in serum, was higher for aztreonam (0.95:1) than for tobramycin (0.46:1). The ratio of the concentration in peritoneal fluid to the minimum inhibitory concentration (MIC) of the infecting bacteria was also higher for aztreonam. Serum pharmacokinetic data were analyzed by both two-compartment and moment analysis. For both the steady-state volume of distribution (Vdss) and total body clearance (TBC), the values determined by both methods were highly correlated (r = .96, .99, respectively). Average values for Vdss and TBC were 0.28 liters/kg and 80 ml/min. TBC for aztreonam correlated strongly with CLcr and was described by the regression equation TBC = 1.1 (Clcr) + 1.6, r = .87, P less than .01.

Abdomen↗

Evaluation of hemoglobin A2 quantitation assay and hemoglobin variant screening by capillary electrophoresis.

To critically assess the method of capillary electrophoresis, we examined 97 clinical samples submitted for hemoglobin electrophoresis by both conventional methods (electrophoresis on cellulose acetate and citrate agar for detection of abnormal variants, ion-exchange chromatography for quantification of HbA2, alkali denaturation for quantification of HbF, supravital stains for detection of HbH) and CE. CE was performed using a 72 cm (50 cm to detector) x 50 microns i.d. fused-silica capillary with detection of absorbance at 200 nm. Of the 97 samples examined, 34 contained a hemoglobin variant. Migration time, the difference of the variant peak to that of HbA, was used in an attempt to identify the hemoglobin variant by CE. We found the method to be suitable for the quantification of HbA2, useful as a screening technique for the presence of hemoglobin variants, but unsuitable for the quantification of HbF.

Child↗