Search PubMed⌕ Search

Biomedical subjects

I Karube

Publications and source records attributed to I Karube.

At least 91 records · Page 5Linked to original sources

Amplification immunoassay for the determination of hepatitis B surface antigen.

A sensitive sandwich immunoassay for the determination of Hepatitis B surface antigen (HBs) was developed, using a cascade system of Limulus amebocyte lysate as a signal amplification system. Lipopolysaccharide (LPS) was conjugated to anti-HBs antibody. Anti-HBs antibody was adsorbed to polystyrene beads. First, HBs were reacted to solid phase anti-HBs antibody (a-HBs). After the reaction, the beads were rinsed, and were then reacted with a-HBs-LPS. Then, LPS activity specifically bound to the beads was measured. HBs could be measured in the range of 10(-10)-10(-12) g/mL.

Hepatitis B Antibodies↗

A quartz crystal viscosity sensor for monitoring coagulation reaction and its application to a multichannel coagulation detector.

A quartz crystal viscosity sensor was applied to a coagulation reaction monitoring system. The system consists of 16 oscillating circuits, a channel selector, a frequency counter, a temperature controller and a microcomputer. The system is named the Quartz Chemical Analyzer (QCA). AT-cut quartz crystals (9 MHz) were used as viscosity detectors and were attached to a cell in order to expose only one side of the quartz plate. The system was applied to the detection of the blood coagulation factors VIII (F VIII) and IX (F IX). The activity of these factors was assayed by a single-stage method. A linear relationship was obtained in a double-logarithmic diagram of concentration versus coagulation time with respect to F VIII and F IX in the range 0.05-0.4 unit cm-3 and 0.025-0.2 unit cm-3, respectively.

Biosensing Techniques↗

Fluorescence polarization immunoassay employing immobilized antibody.

The use of an antibody immobilized on latex or silver colloid in fluorescence polarization immunoassay (FPI) is assessed. In FPI it is possible to detect antigens of high molecular weight because the molecular weight of the antibody is effectively increased. In the assay for rabbit immunoglobulin G a limit of detection lower by two orders of magnitude and an assay range wider by one order of magnitude can be obtained in comparison with conventional FPI. The detection limit is 10(-10) mol l-1 and the total assay time for one sample is 8 min. This assay combines a low detection limit with a short assay time.

Animals↗

Development of acetylcholine sensor using carbon fiber (amperometric determination).

An enzyme sensor is developed using carbon fiber to measure acetylcholine concentration. The mechanism is based on the detection of H2O2 which is a product of the sequential enzyme reactions of acetylcholinesterase and choline oxidase. The fabrication of the electrode is described. The sensor is polarized at 1.2 V. Enzymes are co-immobilized in polyvinyl alcohol containing styryl pyrydinium (photo-crosslinkable polymer). A fast response time of 0.8 min is obtained. A linear correlation is observed between 0.2 and 1.0 mM. Other optimal operational conditions with respect to pH, temperature and stability are discussed. The use of carbon fiber containing co-immobilized enzymes could offer several novel advantages especially in neuroscience research. In conclusion, the aims of the present work are centered on carbon fiber electrode fabrication, immobilization and electrochemical measurements.

Acetylcholine↗

[Biosensors and clinical analysis].

The determination of organic compounds in blood is important in clinical analysis. Most analysis of organic compounds are based on spectrometric methods. However, these methods involve complicated procedures and require a long time for the reaction to occur. Bioelectrochemical sensors employing immobilized biocatalysts have definite advantages. For medical purposes, miniaturization of enzyme sensors is essential. Miniaturized and highly selective enzyme sensors have been developed by combining enzyme immobilization techniques with silicon technologies. Glucose measurement in blood is the most important and essential assay in the clinical field. For this purpose, we have developed various micro biosensors for glucose measurements. Generally, enzymatic determination of glucose is based on the following reaction (s); (formula; see text) According to the above equation, 4 different micro-glucose sensors were developed; 1) a sensor based on the measurement of produced hydrogen peroxide, 2) a sensor based on the measurement of consumed oxygen, 3) a sensor based on the measurement of enthalpy change during the enzymatic reaction, 4) a sensor based on the measurement of the amount of proton produced, and 5) a sensor based on the measurement of the light emission during enzymatic reaction. For these purposes, various kinds of transducers were used. A micro-hydrogen peroxide electrode, a micro-oxygen electrode, a thermistor, an ISFET (ion selective field effect transistor), and a photon counter. The determination of antibodies, or antigens is also very important in clinical analysis. Several types of immuno-sensors have been developed for these purposes. Considering the integration of immuno-sensors, the miniaturization of immuno-sensors is also required. This review deals with our current study on micro-biosensors for clinical analysis.

Biosensing Techniques↗

Identification of proteins encoded in Escherichia coli hydA, hydB and analysis of the hydA locus.

The hydB gene of Escherichia coli, which is related with the expression of hydrogenase activity, was cloned into the plasmid (pES1). Using the maxicell protein-labeling method, the molecular weight of hydB gene product was estimated. Comparing between the gene products from the mutant strains and that of the hydB genes cloned strains, the molecular weight of the gene product was 35,000 Mr. Similarly, the molecular weight of the gene product of hydA, which had been previously cloned, was determined by maxicell analysis. The molecular weight of hydA gene product was estimated to be 80,000 Mr. Using deletion analysis and Tn1000 insertional inactivation of hydA's function, the hydA coding region was estimated between 2.2 kb and 2.8 kb in a 3.1 kb EcoRI-MluI fragment on the recombinant plasmid pEH3.

Bacterial Proteins↗

Facile isolation of endo-pectate lyase from Erwinia carotovora based on electrostatic interaction.

Endo-pectate lyase (PATE) from Erwinia carotovora was selectively cosedimented with extracellularly produced lipopolysaccharide-lipid complex (LPSLC) through dialysis of the cell free culture broth. The selective isolation of PATE was confirmed by sodium dodecyl sulfate polyacrylamide gel electrophoresis. The cosedimentation of the PATE with LPSLC was initiated by decreasing conductivity of the solution and terminated at approx 1 m siemens (mScm-1). As much as 62% of PATE activity in the culture broth was removed by precipitation. PATE was isolated from the precipitate by gel chromatography. The cosedimentation of PATE with LPSLC was remarkably affected by pH or ionic strength. The addition of polycationic peptide polymyxin B sulfate or a metal chloride affected the interaction. The cosedimentation was diminished by acetylation of the free amino groups of PATE. From these results, it was confirmed that the cosedimentation was induced by electrostatic interaction.

Acetylation↗

Microbial sensor.

Explore the source record for details and available documents.

Acetates↗

Microbiosensors.

Explore the source record for details and available documents.

Biosensing Techniques↗

Microbial sensor for preliminary screening of mutagens utilizing a phage induction test.

For the preliminary screening of mutagens, a novel microbial sensor system was developed utilizing a phage induction test. Escherichia coli lysogenic strain GY5027 and nonlysogenic strain GY5026 were used in this study. The number of living cells was determined by measuring the respiration of cells immobilized onto an oxygen electrode. The injection of a mutagen, such as AF-2 and MNNG, caused the phage induction in the lysogenic strain, resulting in the decreased respiration of only the lysogenic strain immobilized onto the oxygen electrode but not of nonlysogenic strain. The rate of current increase correlated well with the concentration of mutagens. The sensor responses to the antibiotics and bactericides were definitely different from those of mutagens. Therefore, utilization of this microbial sensor system makes possible the estimation of a substrate's mutagenicity.

Bacteriophages↗

Ferrocene modified polypyrrole with immobilised glucose oxidase and its application in amperometric glucose microbiosensors.

Gold microelectrodes were modified with electropolymerised polypyrrole in both organic and aqueous electrolytes. Cyclic voltammetry studies confirmed that electron conduction through the films in aqueous electrolytes is greatly reduced and is inefficient at mediating the oxidation/reduction of solution redox species. Films formed in aqueous electrolyte were also found to be more heterogenous in structure compared to those formed in acetonitrile. Aqueous polymerised films were used as an immobilisation matrix for glucose oxidase, and modified gold micro electrodes were used in the analysis of glucose using hydrogen peroxide detection. It was found that glucose oxidase was strongly absorbed into the films and that the sensors remained stable for several weeks. An improved linear range and oxygen insensitivity was achieved by incorporating the "water-insoluble" electron transfer mediator, dimethyl ferrocene, into the polypyrrole films by absorption. Good currents and response times to glucose addition were obtained from these electrodes, however, the electrodes possessed poor stability caused by the apparent loss of mediator from the films. Greater operational stability was achieved by covalently functionalising the films with the ferrocene derivative, ferrocenecarbonyl chloride. Covalently bound ferrocence was found to be an efficient oxidant of reduced glucose oxidase. Electrodes constructed in this manner possessed a good linear range, oxygen insensitivity and better stability. Electron transfer mechanisms are discussed.

Biosensing Techniques↗

DNA cleavage based on high voltage electric pulse.

A high voltage electric pulse was applied to DNA cleavage. The DNA cleavage reaction was dependent on the voltage amplitude, pulse number and pulse width. Radical scavengers and ESR data indicated the possibility that active species such as OH radical were strongly related to DNA cleavage.

DNA↗

Microenzyme sensors.

Explore the source record for details and available documents.

Enzymes, Immobilized↗