Search PubMed⌕ Search

Biomedical subjects

I Gath

Publications and source records attributed to I Gath.

At least 55 records · Page 3Linked to original sources

On the prediction of epileptic seizures.

In 12 epileptic patients suffering from "absences" 8-channel EEG was recorded by telemetry. The autoregressive model was applied to the signal and the prediction coefficients being the basis for calculation of the poles of the predictor. The location of the poles in the z- and s-planes was described as a function of time for 0.1 s steps along the pre-seizure EEG. In 10 of the 12 patients, and in 25 of the 28 recorded seizures this presentation of the poles of the predictor showed specific pattern linked with the occurrence of the seizure. The trajectory of the "most mobile pole" during the pre-seizure period could aid in the prediction of the seizure by several seconds.

Adolescent↗

Computerized analysis of sleep recordings applied to drug evaluation: midazolam in normal subjects.

Computerized analysis of polygraphic sleep recordings was carried out for the evaluation of midazolam, a benzodiazepine hypnotic. The analysis was carried out in real time on a small laboratory computer, and the output included the hypnogram and relative power profiles for the main electroencephalogram activities. Analysis showed a slight "intranight rapid eye movement rebound" during medication and reduction of sleep stage IV after withdrawal. The relative power of the delta frequency band did not change during medication or withdrawal.

Adult↗

Computerized method for scoring of polygraphic sleep recordings.

A new method for automatic analysis of polygraphic sleep recordings is described. The analysis is to be carried out on a small laboratory computer in two phases. The first phase is a real-time signal processing during which the EEG signal is being divided into quasi-stationary segments of uneven length and homogeneous in their spectral content, ands the EOG and EMG signal analysed. The second phase is a very short off-line operation, comprised of sequential clustering of the segments, using fuzzy subset theory, and optimal fuzzy partition. The output available is the hypnogram, describing the sequence of sleep stages during the night, graphs describing the relative power changes of the main EEG activities (delta, theta, alpha and sigma), and 3-dimensional plots of the spectral changes during the night. In addition, a few quantitative measures related to the relative amount of the various sleep stages and to the number of rapid eye movements are calculated.

Computers↗

An iterative algorithm for the separation of action potential sequences.

Various iterative algorithms for separation of superimposed event sequences were designed, and their efficiency examined through simulation studies. It has been found that a double parallel-serial algorithm improved markedly the efficiency of the filtration process. For the same probability of detection of the event series to be extracted, the probability of 'impurity' events dropped by roughly 0.10, as compared to the non-iterative fixed window width algorithm. Conclusions are drawn regarding separation of motor unit action potential sequences from the total electromyogram.

Action Potentials↗

Time and frequency analysis of simultaneously recorded corneal and non-corneal electroretinogram.

Electroretinograms (ERGs) were simultaneously recorded with corneal and non-corneal (lower or upper eye lid) electrodes in four healthy subjects. 64 traces of the non-corneal ERG were averaged. The two signals were compared in both time and frequency domains. The power spectrum of both signals was computed by the fast Fourier (FFT) and linear prediction (LP) algorithms. Except for amplitude differences, the two signals had almost identical time domain (a- and b-wave latencies) and frequency domain (dominant power spectrum peaks) parameters. It is concluded that non-corneal ERG does not differ significantly from corneal ERG, and that its clinical interpretation can be based on existing corneal ERG data.

Adult↗

Screening of patients with Huntington's chorea by pneumoencephalography: criteria for decision and probability of error.

The problem of making a decision in case of two clinical hypotheses is treated by the application of the Neyman-Pearson criterion. As an example, a pneumoencephalographic index (frontal horn width divided by septum-caudate distance) of two different diseases, Huntington's chorea and Parkinsonism, is analyzed. As the aim of the investigator is to detect the maximum number of cases of Huntington's chorea, an appropriately high alpha, (the probability of "false alarm") should be chosen, and maximization of 1-beta (the probability of detection of Huntington's chorea) carried out.

Humans↗

The calculated radial decline of the extracellular action potential compared with in situ measurements in the human brachial biceps.

Action potentials from 16 single muscle fibres were recorded with a multi-electrode from the human brachial biceps. Propagation velocity was calculated for 10 of the fibres, and the volume conduction at distances of 79, 152 and 251 micrometer, was measured for 6 of these fibres. The radial decline of the action potentials was calculated from the Fourier transform of the action potential at the origin, simulating the low-pass filter characteristics of the muscle tissue by sections of RC elements. A good agreement was found between the calculated data and the experimental data on the radial decline of the action potentials. The 90% attenuation radius of the action potential recorded with a 25 micrometer electrode, calculated for 16 action potentials, was derived from the volume conduction calculations. The average value found was 191 +/- 20 micrometer. A linear correlation was found between this radius and the peak spectral amplitude of the action potentials. Likewise, a linear correlation between the 90% attenuation radius and the propagation velocity of the fibres was confirmed.

Action Potentials↗

On the volume conduction in human skeletal muscle: in situ measurements.

Volume conduction was studied in situ in human skeletal muscle, using a "single fibre multielectrode". The multielectrode was inserted perpendicular to the fibre axis, and the same single fibre action potential was recorded consecutively from 4 neighbouring leading-off surfaces. The transfer functions of 10 sections of muscle tissue lying between pairs of neighbouring electrodes were calculated from the Fourier transform of the input and output, i.e. the action potential recorded by the two neighbouring leading-off surfaces. The transfer function had one dominant pole, and was therefore modelled by a section of lumped RC elements The average gain factor and average time constant calculated from the transfer function for a muscle tissue section of 76 mu length were 0.55 and 69 musec, respectively. The radial attenuation of the different sinusoidal components of the extracellular action potential was calculated, and was found to be greater than previously reported in the literature, particularly for the slow frequency components. As an explanation of these findings, the possibility of a greater anisotropy of the muscle tissue than previously reported is discussed.

Action Potentials↗

Penumoencephalographic findings in parkinsonism.

Pneumoencephalograms of 19 patients with unilateral parkinsonism, and of 26 patients with symptoms of generalized parkinsonism were studied. Cortical atrophy was found in 46.7% (21), while central (ventricular) atrophy occurred in 77.8% (35) of the patients. The percentage of patients with cortical atrophy, or with enlargement of ventricular body span (VBS) and septum-caudate distance (S-C), was smaller in the hemiparkinsonism group. No substantial correlation was found between enlargement of frontal horn width (FH), S-C and third ventricle width (3V), and the duration of illness. Likewise, no noteworthy correlation could be seen between the degree of central atrophy and the severity of the clinical symptoms. The FH/S-C ratio of the group of unilateral parkinsonism patients was higher than in the generalized parkinsonism group. The FH/S-C ratios in parkinsonism and in Huntington chorea patients varied. A ratio of greater than 1.40 was found in 73.3% of the patients with parkinsonism, and in an earlier study, it was found that 96.4% of the patients with Huntington chorea had a ratio less than 1.40. It is suggested that a FH/S-C ratio less than or equal to 1.40 is compatible with the diagnosis of Huntington chorea, although 26.7% (12) patients with parkinsonism have a ratio less than or equal to 1.40.

Adult↗

On the separation of semiperiodic superimposed point processes: application to electromyographic signals.

A method for the separation of semiperiodic (Gaussian probability distribution of intervals with moderate coefficient of variation) superimposed point processes, to be implemented on a digital computer is described. The efficiency of the filter used for the extraction of the underlying event sequences from the pooled array has been investigated by simulation. Approximately 80 percent of the events belonging to the underlying sequence to be extracted were recovered (with the addition of "impurity events"), still preserving the mean rate and coefficient of variation of the original indicidual sequence concerned. The program was used on an example of an actual electromyographic recording (comprised of a number of motor units discharging simultaneously), resolving the number of motor units involved, their mean rates, and the coefficient of variation of the individual action potential sequences.

Action Potentials↗

Frequency and time domain characteristics of single muscle fibre action potentials.

Action potentials of single muscle fibers (brachial biceps) were recorded with a multi-electrode, ensuring a minimum fibre-electrode recording distance. Propagation velocity was measured in 15 fibres and the power spectral density of the action potentials was computed through a FFT algorithm. Linear correlation was found between action potential amplitude (peak to peak) and propagation velocity, as well as between maximum-minimum amplitude time (defined as the time interval between the positive and negative peaks) and propagation velocity. Assuming al linear dependence between propagation velocity and muscle fibre diameter, a linear relation between the fibre thickness and the extra-cellular action potential was derived from the action potential amplitude/propagation velocity curve. The action potential power spectrum had a band pass form, with peak magnitude of 1.61+/-0.03 kc/sec, and -3 dB points at 0.98+/-0.19 kc/sec and at 2.41+/-0.53 kc/sec. A linear relation was found between the spectral peak magnitude and propagation velocity, and between the ban width and the propagation velocity, as predicted by a mathematical model describing the power spectrum of single fibre action potentials.

Action Potentials↗