A bacteriologically occlusive clothing system for use in the operating room.

A comparison was made in a laminar-flow operating room between total-body exhaust gowns and a clothing system made from Fabric 450. This disposable clothing was found to be much more comfortable and convenient than the total-body exhaust gowns. The average airborne bacterial counts obtained during total hip replacement operations from each of the clothing systems were identical when the downflow method of ventilation was used (0.7 per cubic metre) and no significant difference could be demonstrated when the crossflow system was used (2.2 per cubic metre with the total-body exhaust gowns and 3.1 per cubic metre with the disposable clothing). Tests in a dispersal chamber were carried out to find the effectiveness of each item of the disposable clothing in reducing bacterial dispersion. These tests demonstrated the relative ineffectiveness of wearing a surgical gown as compared with wearing the complete system. It was confirmed bacteriologically that the downflow system of ventilation was more efficient than the crossflow type; the importance of this observation with respect to clothing and sepsis is discussed in this paper.

Air Microbiology↗

Biomechanical assessment of patients treated by joint surgery.

Surgical replacement of lower limb joints has been practised for twenty years although there is little quantitative information on loads transmitted either by implants or by other related joints. The results of tests are presented which evaluate the variation in external forces developed between the ground and foot during walking, together with the configuration of the lower limbs and the moments acting about the hips and knees. Two groups of patients were investigated; patients who were assessed prior to joint replacement and at intervals thereafter, and patients for whom the Girdlestone procedure was performed following a failed implant. The results area compared with those from similar tests on clinically normal subjects. There is a significant improvement post-operatively in the mechanical aspects of hip function for the replacement patients. The improvement continues after the first six months post-operatively and may result in abnormally high loading at other joints. At twelve months the performance of the patients with joint replacement differs significantly from the normal subjects and is generally better than the Girdlestone patients.

Biomechanical Phenomena↗