Search PubMed⌕ Search

Biomedical subjects

I De Scheerder

Publications and source records attributed to I De Scheerder.

At least 37 records · Page 2Linked to original sources

The safety of intracoronary ultrasound. A multicenter survey of 2207 examinations.

BACKGROUND: Intracoronary ultrasound (ICUS) is increasingly used in clinical practice to study the natural history of coronary artery disease and to assess the effects of intracoronary, catheter-based interventions. However, the risk associated with the procedure is not well documented. METHODS AND RESULTS: ICUS studies performed in 28 centers were retrospectively included; these centers agreed to contribute to the study among a total of 60 centers initially invited. Among the 2207 ICUS studies, 505 (23%) were performed in heart transplant recipients and 1702 (77%) in nontransplant patients. Indication for ICUS was diagnostic imaging in 915 (41%), drug testing in 244 (11%), and guidance for intracoronary interventions in 1048 patients (47%). There were no complications in 2034 patients (92.2%). In 87 patients (3.9%), complications occurred but were judged to be "not related" to ICUS by the operator. In 63 patients (2.9%), spasm occurred during ICUS imaging. In 9 patients (0.4%), complications other than spasm were judged to have a "certain relation" to ICUS, including acute procedural events in 6 (3 acute occlusion, 1 embolism, 1 dissection, and 1 thrombus) and major events in 3 patients (2 occlusion and 1 dissection; all resulting in myocardial infarction). In 14 patients (0.6%), complications with "uncertain relation" to ICUS were recorded, including acute procedural events in 9 (5 acute occlusion, 3 dissection, and 1 arrhythmia) and major events in 5 patients (2 myocardial infarction and 3 emergency coronary artery bypass surgery). The incidence of acute procedural or major complications judged to be associated with ICUS (uncertain relation or certain relation to ICUS) was compared in different patient groups. The complication rate was higher in patients with unstable angina or acute myocardial infarction (2.1% events) as compared with patients with stable angina pectoris and asymptomatic patients (0.8% and 0.4%, respectively; chi 2 = 10.9, P < .01). These complications were also more frequent in patients undergoing interventions (1.9%) as compared with transplant and nontransplant patients undergoing diagnostic ICUS imaging (0% and 0.6%, respectively; chi 2 = 13.5, P < .001). Adverse events were few, and no association was detected between these events and the size or type of ICUS catheter used. CONCLUSIONS: ICUS is associated with (but not necessarily the direct cause of) a minor acute clinical risk. Vessel spasm is the most frequent event occurring during ICUS. Other complications predominantly occur in patients with acute coronary syndromes and during guidance for intervention.

Adult↗

In vivo comparison of different quantitative edge detection systems used for measuring coronary arterial diameters.

Three different systems for quantitative coronary analysis [Cardiovascular Measurement System (CMS); Polytron 1000; Angiographic Workstation (AWOS)] were compared in 109 patients before and after coronary angioplasty and at follow-up coronary angiography. Correlation coefficients were low and 95% limits of agreement were wide. In general, CMS exhibited a tendency to yield lower values for very small diameters and higher values for larger vessels. The acute gain in minimal luminal diameter was considerably smaller when assessed by AWOS as compared to Polytron (0.52 vs. 0.71 mm, P < .0001) and to CMS (0.52 vs. 0.75 mm, P < .0001). Long-term gain was much larger when assessed by Polytron as compared to AWOS (18.8 vs. 11.5%, P < .001) and it was almost double for CMS as compared to AWOS (20.7 vs. 11.5%, P < .0001). In conclusion, in the individual patient very different results can be obtained when different QCA systems are used, and systematic differences between the systems are encountered.

Algorithms↗

Limited value of exercise testing in the detection of silent restenosis after successful coronary angioplasty.

We studied the diagnostic value of exercise electrocardiographic (ECG) testing in 191 patients who were completely asymptomatic 6 months after a successful percutaneous transluminal coronary angioplasty procedure. With > 70%- and > 50%-diameter stenosis at follow-up as restenosis criteria, the sensitivities of exercise ECG testing were 29% and 21%; the specificities 89% and 91%; the positive predictive values 20% and 52%; the negative predictive values 93% and 70%; the accuracies 83% and 68%; and the risk ratios 2.8 and 1.7, for prevalences of 9% and 33%, respectively. There were no significant differences in the diagnostic value of exercise ECG testing between men and women, patients receiving or not receiving beta-blocking agents, and the presence or absence of pathologic Q waves. Significant differences in systolic blood pressure and the rate-pressure product at peak exercise were found between patients with and without restenosis. For individual patients, however, no practical conclusions can be drawn from these values. In conclusion, the diagnostic value of exercise ECG testing for silent restenosis is low, and supplementation with other techniques seems to be warranted.

Adult↗

The impact of balloon material and lesion characteristics on the incidence of angiographic and clinical complications of coronary angioplasty.

To assess the importance of balloon material used for percutaneous transluminal coronary angioplasty (PTCA), we compared the complication rates observed with low complaint plastomer (PM 300), intermediately compliant polyethylene (PE 600), and highly compliant polyolefin copolymer (POC) balloons. In a total of 1,650 procedures, one of these balloon materials was used to dilate 2,040 lesions. The dissection rate tended to be slightly lower with the use of more compliant balloon material. The total clinical complication rate (death, emergency coronary surgery, myocardial infarction, need for bail-out stenting or for prolonged heparin treatment, abrupt out-of-laboratory vessel closure) was 8.1%, 7.4%, and 4.2% in the procedures exclusively performed with PM 300 (N = 653), PE 600 (N = 543) and POC (N = 454) balloons, respectively (P = 0.03). In multivariate analysis, the use of less compliant balloon material emerged as an independent correlate of clinical complications (P = 0.007). However, the predictive power of the lesion complexity (B2, C versus A, B1) was four times stronger. In contrast to current concerns, the use of compliant balloon material seems at least as safe as the use of less compliant material.

Aged↗

Intravascular ultrasound versus angiography for measurement of luminal diameters in normal and diseased coronary arteries.

Quantitation of coronary luminal diameter with a 20 MHz mechanically rotating intravascular ultrasound (IVUS) catheter was compared with orthogonal-view cineangiography by use of a semiautomated edge-detection algorithm in 48 patients undergoing coronary angioplasty. Quantitative comparison of 196 matched segments was attempted, but in only 174 (88.8%) was a direct comparison of the two techniques possible. In angiographically normal coronary arteries (46 segments) the correlation between the values obtained by quantitative coronary angiography (QCA) and those achieved by IVUS was excellent (r = 0.92, p < 0.0001). For mild stenoses (80 segments) the correlation coefficient was only fair (r = 0.467, p < 0.001). After percutaneous transluminal coronary angioplasty the correlation coefficient between IVUS and QCA data (48 segments) was very weak (r = 0.282, p < 0.05). In conclusion, coronary IVUS is feasible and safe and even for a limited range of coronary arterial narrowing, significant correlations between IVUS and QCA measurements of minimal lumen diameter were found. They were excellent in normal coronary arteries, moderate in mildly diseased arteries, and weak after balloon angioplasty.

Angioplasty, Balloon, Coronary↗

Angiotensin-converting enzyme inhibition with fosinopril sodium in the prevention of restenosis after coronary angioplasty.

BACKGROUND: Several angiotensin-converting enzyme inhibitors have antiproliferative effects in a rat model after carotid artery balloon injury. METHODS AND RESULTS: We conducted a randomized, double-blind, placebo-controlled trial to assess the effect of fosinopril, a novel angiotensin-converting enzyme inhibitor, in restenosis prevention after percutaneous transluminal coronary angioplasty (PTCA). Patients received fosinopril or matched placebo 10 mg at least 18 hours before PTCA, 20 mg at least 4 hours before PTCA, and 40 mg daily for 6 months. In addition, all patients received aspirin. Coronary angiograms before PTCA and immediately after PTCA as well as at 6-month follow-up were quantitatively analyzed. A total of 509 patients were recruited. The final per-protocol population consisted of 153 fosinopril-treated and 151 placebo-treated patients. Restenosis rates according to the National Heart, Lung, and Blood Institute criterion 4 (loss of > or = 50% of the initial gain [primary end point]) were 45.7% and 40.7% in the fosinopril and control groups, respectively (not significant). The respective mean differences in minimal coronary luminal diameter between post-PTCA and follow-up angiograms were -0.59 +/- 0.71 mm and -0.51 +/- 0.67 mm (not significant). Clinical events during the 6-month follow-up period, analyzed on an on-treatment basis, were ranked according to the most serious event. The respective numbers in the fosinopril and the control groups were for death, 0 and 0; myocardial infarction, 0 and 0; coronary artery bypass graft surgery, 1 and 3; repeat PTCA, 35 and 35; recurrent signs of ischemia necessitating early repeat coronary angiography and managed medically, 6 and 7; and none of the above, 111 and 106. All these differences were significant. CONCLUSIONS: Administration of fosinopril in a dose of 40 mg daily during 6 months after PTCA does not prevent restenosis and has no effect on overall clinical outcome.

Angioplasty, Balloon, Coronary↗

Role of intravascular ultrasound in coronary artery disease: a new gold standard? An overview.

Although selective contrast coronary arteriography has been the gold standard approach for coronary imaging since more than 30 years, new coronary imaging techniques are currently under development. Intravascular ultrasound (IVUS) is perhaps the most promising of these additional techniques. IVUS makes use of miniaturised crystals incorporated at catheter tips and provides real time, cross-sectional and longitudinal, high resolution images of the arterial wall with three-dimensional reconstruction capabilities (Pandian, 1989; Coy et al., 1991; Liebsen & Klein, 1992). Different devices have been constructed. Actually two types are being used: mechanical (hand-rotated or motor-driven) systems and phased array systems using high-frequency (20-30 MHz) transducers (Bom et al., 1989). Coronary ultrasound imaging performed during catheterization is feasible and safe as demonstrated in several studies examining normal and pathologic coronary arteries (De Scheerder et al., in press).

Coronary Disease↗

Echocardiographic detection of acute myocardial ischemia during percutaneous transluminal coronary angioplasty.

The usefulness of echocardiography and Doppler for the detection of acute myocardial ischemia was evaluated during right coronary artery occlusion in 20 patients. The echocardiographic findings were compared with the occurrence of chest pain, and to electrocardiographic and hemodynamic changes obtained during percutaneous transluminal coronary angioplasty. Our results confirm that, even in the case of small segmental myocardial ischemia, two-dimensional echocardiography is superior to all other measured parameters. In contrast, Doppler examination of transmitral flow is not sensitive enough for the detection of such small segmental myocardial ischemia induced by right coronary artery occlusion.

Adult↗

The use of intracoronary ultrasound for quantitative assessment of coronary artery lumen diameter and for on-line evaluation of angioplasty results.

UNLABELLED: The value of intracoronary ultrasound for quantitative assessment of minimal coronary arterial diameter and for on-line evaluation of balloon angioplasty result was studied in 42 patients undergoing single vessel coronary angioplasty. Measurement of minimal luminal diameter of 75 matched coronary arterial segments showed a significant correlation between both the ultrasound and angiographic method (r: 0.759; p < 0.001). Furthermore using intravascular ultrasound it was possible to classify the obtained coronary balloon angioplasty results. A preliminary correlation between ultrasound classification and the in-hospital acute rethrombosis as well as late restenosis was attempted in individual patients. CONCLUSIONS: 1) Clinical use of coronary ultrasound is feasible and safe in selected cases. 2) A significant correlation between intracoronary ultrasound and quantitative coronary angiography is demonstrated. 3) Using intracoronary ultrasound seems promising for evaluation of the postangioplasty result, and may finally lead to improved selection of the interventional strategy.

Angioplasty, Balloon, Coronary↗

Immediate and follow-up results of the conservative coronary angioplasty strategy for unstable angina pectoris.

To assess the results of a conservative coronary angioplasty strategy in unstable angina pectoris, the records of 1,421 consecutive patients without previous myocardial infarction undergoing a first percutaneous transluminal coronary angioplasty (PTCA) between 1986 and 1990 were reviewed. Of these patients, 631 had unstable and 790 had stable angina pectoris. Only after an intense effort to medically control symptoms, the unstable patients underwent PTCA at an average of 15.4 days (range 1 to 76) after hospital admission. Primary clinical success was achieved in 91.7% of patients with unstable and in 94.4% of those with stable angina pectoris (p = not significant). In-hospital mortality rates were 0.3 and 0.1%, respectively (p = not significant). Nonfatal in-hospital event rates for acute myocardial infarction, cerebrovascular accident and coronary bypass surgery were only slightly higher in patients with unstable angina pectoris; however, the difference from the stable group was significant when all events were combined (9 vs 5.9%; p less than 0.04). During 6-month follow-up, no significant difference in adverse events was found between the groups. The respective rates for the unstable and stable groups were 0.4 and 0.2% for death, 5.5 and 5.1% for major nonfatal events, and 17.7 and 20.1% for repeat PTCA. These results suggest that use of a conservative PTCA strategy in the treatment of patients with unstable angina pectoris results in favorable and similar immediate and 6-month outcomes compared with those in patients with stable angina pectoris.

Angina Pectoris↗

Plasma and erythrocyte lipids in two families with heterozygous hypobetalipoproteinemia.

Erythrocyte morphology, kinematic viscosity, and membrane lipid composition have not been well documented in heterozygous hypobetalipoproteinemia (HBL). In our study of nine subjects with HBL from two kindreds, three presented with schistocytes (3-6%) while two of them also showed acanthocytosis (25-35%) on their peripheral blood films. The other affected family members had a normal RBC morphology despite a decreased kinematic viscosity of RBC suspension at 37 degrees C (log eta = 0.20 +/- 0.02 vs. log eta = 0.26 +/- 0.02) in all nine subjects; erythrocyte osmotic fragility however was normal. Although some subjects showed acanthocytosis total cholesterol (0.63 +/- 0.05 mol x 10(-6)/mg membrane protein) and sphingomyelin/lecithin ratio (0.905 +/- 0.042) of RBC membranes were normal while plasma from the subject with schistocytosis had a significantly decreased sphingomyelin/lecithin ratio in plasma (17.2 +/- 2.4 vs. 29.1 +/- 3.3) suggesting that sphingomyelin and lecithin are not freely exchangeable between plasma and the outer surface of RBC membranes.

Adult↗

Creatine determinations as an early marker for the diagnosis of acute myocardial infarction.

In the acute phase of acute myocardial infarction (3-8 h after onset of symptoms) an early transient increase in the creatine concentration of serum, saliva, and especially of urine can be observed. Due to the renal threshold, urine values give a much better discrimination between infarction patients and controls than do serum determination. In some patients secondary peaks of serum and urine creatine concentrations can be seen about 24-36 h after hospital admission. Intramuscular injections of 5.0 mL of a saline solution and muscular trauma interfere with the test, but with angina pectoris interference is absent or limited. Creatine leakage from myocardium is insufficient to explain the observed creatinuria in infarctions, and intact extra-cardiac tissues are believed to be involved in creatine release.

Adolescent↗

Measurement of activation energy of gamma-glutamyltransferase as a marker for enzyme heterogeneity.

In order to detect differences between various multiple forms of gamma-glutamyltransferase, the activation energy was measured. In the serum of patients with liver diseases, activation energy was measured. In the serum of patients with liver diseases, activation energy of the serum enzyme is higher than in normal individuals (41.9 +/- 1.2 vs. 38.9 +/- 1.5 kJ/mol, p less than 0.05). Neuraminidase treatment resulted in a reduction of activation energy. Various multiple forms of serum gamma-glutamyltransferase, as prepared by lectin affinity chromatography (concanavalin A, Ricinus communis I and II, wheat germ agglutinin) showed activation energy differences between binding and nonbinding fractions. Similar results were observed in seminal plasma gamma-glutamyltransferase, when patients with accessory gland infection were compared with a reference population. Our results suggest that the activation energy depends upon differences in the carbohydrate part of the enzyme. The low gamma-glutamyltransferase activation energy of tissue extracts increased significantly after butanol extraction and was then comparable with serum activation energy values, which suggests that lipid-binding is a factor in activation energy variation. In most cases, gamma-glutamyltransferase activities measured at a certain temperature can be easily converted to a corresponding activity at another temperature, but in severe liver disease significant errors may be introduced when simple temperature conversion factors are used.

Chromatography, Affinity↗

Primary cardiac tumors: retrospective evaluation of 15 consecutive patients.

During a decade (1975-1985) 15 patients have been treated for a primary cardiac tumor at the University Hospital of Ghent. Histological examination revealed both benign (n = 12) (myxoma, pseudomyxoma, myxoid degeneration) and malignant (n = 3) (angiosarcoma) tumors. Tumor diagnosis generally was made by echocardiographic and/or angiocardiographic examination of patients presenting with various constitutional and/or cardiac symptoms. In two patients however diagnosis became obvious by histological examination of the material removed during acute embolectomy. All tumors were surgically resected with the aid of extracorporeal circulation. Benign tumors have generally good prognoses, although rhythm or conduction disturbances, complete obstruction or embolization can entertain malignant consequences. Three of our patients died of such a complication. Therefore all cardiac tumors should be resected as soon as possible after diagnosis. One patient showed evidence of recurrence of the tumor. Malignant heart tumors have bad prognoses: all three of our patients died within two years.

Adult↗

A six years review on 53 cases of infective endocarditis: clinical, microbiological and therapeutical features.

Microbiological features, diagnostic investigations, treatment, and complication rate in 53 cases of infective endocarditis were reviewed in this study. Infection occurred both on prosthetic (47%) and native valves (38%), while in 15% of the cases no prior valvular disease was known. Streptococcal (38%) and staphylococcal (30%) infections were predominant. In 17% of the cases apparent negative blood cultures were obtained. The most frequent portal of entry was dental infection or manipulation (45%), however in 28% of the patients etiology remained obscure. Major clinical signs and symptoms included heart murmurs (96%), fever (91%), dyspnoea (32%), and splenomegaly (30%). Echocardiography revealed vegetations in 78%, aortic and mitral valve being nearly equally affected. All patients were medically treated and 53% received antibiotics prior to blood cultures. Associations of ampicillin or penicillin with an aminoglycoside (43%) and penicillinase-resistant antibiotics (30%) were most frequently administered. In 28% of the patients, it was necessary to insert a prosthetic (aortic or mitral) valve. During follow-up, heart failure (28%), embolization (11%), and infections (11%) were the major complications.

Adult↗