Search PubMedSearch

Biomedical subjects

I D Zinner

Publications and source records attributed to I D Zinner.

13 recordsLinked to original sources

Clinical management of abutments with intracoronal attachments.

A method of preparing teeth to accommodate intracoronal attachments is presented. The resulting prosthesis incorporates a fixed partial denture with physiologically contoured crowns and a removable partial denture with a precisely determined path of insertion. These techniques stress the importance of surveyed diagnostic casts and coordinated tooth preparations for artificial crowns to facilitate treating complex cases.

Crowns

A modification of the Thompson dowel rest for distal-extension removable partial dentures.

A prefabricated Thompson dowel rest semiprecision attachment system for distal-extension removable partial dentures deserves consideration in the treatment planning of periodontally involved dentitions. It is a system that provides for rotation and therefore stress-breaking with controlled movement. Many other stress-breaking systems provide for rotation without specific control. In addition, the Thompson dowel rest system is the only stress-breaker that is intracoronal not extracoronal. This prefabricated system offers facilitation of laboratory procedures, eliminates the need for utilization of gold for dowels, reduces the size of the rest seats, and aids in the preservation of the integrity of the hard and soft supporting tissues.

Denture Design

Provisional restorations in fixed partial prosthodontics.

Concepts and techniques for fabrication of various types of provisional fixed restorations have been described. The problems created by less than optimal construction are presented. The clinician must decide which type of fixed provisional appliance is desirable or required in various situations. The same fixed provisional restoration cannot be suitable in every situation. The dentist must be able to evaluate and select which type of interim fixed prosthesis should be constructed for the various cases that present in their offices.

Denture Design

Provisional prosthodontic appliances in the combination fixed-removable reconstruction.

Various combination fixed-removable prostheses have been presented. The construction of the combined provisional prostheses permits the clinician to establish the desired occlusal harmony, esthetics, and jaw relationships, as well as optimal management of the patient. The provisional template allows the clinician to determine patient reaction and response prior to construction of the definitive prostheses. This leads to better clinician-patient rapport and patient satisfaction. Also, it minimizes postinsertion adjustments.

Consumer Behavior

Presurgical prosthetics and surgical templates.

An overview has been presented of the prosthodontic procedures used prior to the first stage of implant surgery, the procedures used between the first and second stages of surgery, and the prosthetic appliances fabricated prior to insertion of the definitive implant prosthesis. In addition, the need for suggestions to the surgeon for optimal implant fixture placement using surgical templates has been discussed. The design and fabrication of a preferred mandibular surgical template has been presented. In addition, it has been recommended that the surgeon and restorative dentist should employ a team approach to implantology for the best results.

Dental Implantation, Endosseous

Precision attachments.

This article presents an overview of the techniques and rationale of the various impression procedures employed in the fabrication of the removable portion of a combination fixed and removable reconstruction.

Dental Abutments

Locking types of semiprecision attachments.

An overview of the various locking types of semiprecision rests was presented along with several methods for their use in partial denture construction. By using the attachments selectively, the dentist should be able to direct the technician in their construction. All the types and systems presented serve the functions of retention, bracing, and support, which are the requirements for any removable partial denture retainer system.

Dental Abutments

Nonlocking types of semiprecision attachments.

The history of the nonlocking type of intracoronal semiprecision rest has been traced from its origins with Neurohr in 1930, up to its present use as the Thompson dowel rest. The advantages of the use of this deep rest design and the clasp arm design for primary retention have been discussed. The Blatterfein modification of the lingual clasp arm has been introduced to overcome the problems of breakage and lack of stabilization that are present with the Thompson, Van Dam, and Wands designs. Several clinical situations have been illustrated demonstrating the variety of applications of the Thompson dowel rest type of semiprecision prostheses.

Dental Abutments

Semiprecision rest system for distal-extension removable partial dentures.

The history of the nonlocking type of intracoronal semiprecision rest has been traced from its origins with Neurohr in 1930, up to its present use as the Thompson dowel rest. The advantages of the use of this deep rest design and the clasp arm design for primary retention have been discussed. The Blatterfein modification of the lingual clasp arm has been introduced to overcome the problems of breakage and lack of stabilization which are present with the Thompson, Van Dam, and Wands designs.

Dental Abutments

Prefabricated metal intracoronal semiprecision attachments for removable partial dentures.

The inaccuracies of the casting and fitting processes associated with semiprecision intracoronal attachment systems may compromise the fit of the completed prosthesis. The objective of using metal prefabricated intracoronal semiprecision attachments is to improve the adaptation between the matching attachment surfaces used in the fabrication of removable partial dentures. In milled dovetail or waxed dowel rests, the attachment of one side is completed and the other is cast to match. The prefabricated attachment system presented uses a matching component cast directly against the precast metal rest-mandrel. This reduces the inaccuracies resulting from waxing, investing, and casting.

Denture Design